Chemical Analysis Instruments
Filter
Showing 10471–10500 of 10547 results
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Omni-λ300i |
| Application System | Universal |
| Grating Capacity | Triple-Grating Turret |
| Focal Length | 320 mm |
| Optical Design | Czerny-Turner with Toroidal Imaging Correction |
| Stray Light Rejection | 1×10⁻⁵ |
| Grating Size | 68×68 mm (or 68×84 mm optional) |
| Entrance/Exit Options | Side or Dual Input/Output Configurable |
| Slit | Manual (0.01–3 mm width, 2/4/14 mm height), Motorized Slit Optional |
| Detector Interface | Dual CCD Output Standard |
| Control Interface | USB 2.0 (RS-232 Optional) |
| Wavelength Accuracy | ±0.1–±3.2 nm (dependent on grating) |
| Wavelength Reproducibility | 0.015–0.8 nm |
| Spectral Resolution (PMT) | 0.04–1.28 nm |
| Spectral Resolution (15 µm-pixel CCD) | 0.069–3.05 nm |
| Linear Dispersion (@435.83 nm) | 0.91–40.43 nm/mm |
| Scan Range | 0–19,200 nm (grating-dependent) |
| Scan Step | 0.0025–0.08 nm |
| F/# | f/4.2 |
| Image Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Dimensions | 420 × 295 × 232 mm |
| Weight | 16 kg |
| Max Power Consumption | 100 W @ 24 V DC |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Omni-λ500i |
| Application System | Universal |
| Number of Gratings | Triple-grating turret |
| Focal Length | 500 mm |
| Optical Design | Czerny-Turner with toroidal imaging correction |
| Stray Light Level | 1×10⁻⁵ |
| Grating Size | 68×68 mm (or 68×84 mm optional) |
| Entrance/Exit Configuration | Side entrance, dual出口 (CCD + slit), configurable multi-port options |
| Slit Width Range | 0.01–3 mm (manual standard |
| Slit Height Options | 2 mm, 4 mm, or 14 mm |
| Focal Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Weight | 22 kg |
| Power Consumption | ≤100 W @ 24 V DC |
| Communication Interface | USB 2.0 (standard), RS-232 (optional) |
| Control Architecture | DSP-based motorized turret & port selection |
| Wavelength Accuracy | ±0.1 nm to ±3.2 nm (dependent on grating) |
| Wavelength Repeatability | 0.015–0.8 nm (grating-dependent) |
| Spectral Resolution (with point detector) | 0.03–0.8 nm |
| Spectral Resolution (with 15 µm-pixel CCD) | 0.045–1.97 nm |
| Linear Dispersion (@435.83 nm) | 0.6–26.05 nm/mm |
| Mechanical Scan Range | 0–19,200 nm (grating-dependent) |
| Minimum Step Size | 0.0025–0.08 nm (grating-dependent) |
| CCD Single-Capture Spectral Range (@30 mm sensor) | 18–781.5 nm (grating-dependent) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-λ750i |
| Application System | Universal |
| Number of Gratings | Triple-grating turret |
| F/# | F/9.7 |
| Focal Length | 750 mm |
| Optical Design | Czerny-Turner with toroidal imaging correction |
| Stray Light Rejection | 1×10⁻⁵ |
| Grating Size | 68×68 mm (optional 68×84 mm) |
| Slit Width Range | 0.01–3 mm (manual standard |
| Slit Height Options | 2 mm, 4 mm, or 14 mm |
| Entrance/Exit Configuration | Side entrance |
| Wavelength Accuracy | ±0.1–±3.2 nm (dependent on grating) |
| Wavelength Reproducibility | 0.015–0.8 nm |
| Spectral Resolution (PMT) | 0.02–0.36 nm |
| Spectral Resolution (15 µm-pixel CCD) | 0.033–1.329 nm |
| Linear Dispersion (@435.83 nm) | 0.43–17.58 nm/mm |
| Mechanical Scan Range | 0–19,200 nm (grating-dependent) |
| Minimum Step Size | 0.0025 nm |
| CCD Single-Capture Span (@30 mm sensor) | 12.9–527.4 nm |
| Interface | USB 2.0 (standard), RS-232 (optional) |
| Control Architecture | Embedded DSP-based motion and port logic |
| Coating Options | Standard Al+MgF₂ (UV-VIS), gold (IR >1 µm), enhanced UV (e.g., MgF₂ overcoat) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-λ750S |
| Application System | Universal |
| Grating Capacity | Triple-grating turret |
| Focal Length | 750 mm |
| Optical Design | Czerny-Turner with toroidal image correction |
| Stray Light Rejection | 1×10⁻⁵ |
| Entrance/Exit Options | Dual entrance, dual exit |
| Standard Interface | USB 2.0 |
| Grating Size | 68×68 mm (optional 68×84 mm) |
| Slit Width Range | 0.01–3 mm (manual), motorized slit optional |
| Slit Height Options | 2 mm / 4 mm / 14 mm |
| Focal Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Relative Aperture | f/9.7 |
| Minimum Scan Step | 0.0025 nm (with 2400 g/mm grating) |
| Wavelength Accuracy | ±0.1 nm (at 435.83 nm, 2400 g/mm) |
| Wavelength Repeatability | ±0.015 nm (at 435.83 nm, 2400 g/mm) |
| CCD Spectral Resolution (15 µm pixel) | 0.026 nm (2400 g/mm) |
| Single-shot CCD Spectral Coverage | 12.9 nm (30 mm CCD, 2400 g/mm, 435.83 nm center) |
| Infrared Optimization | Gold-coated optics for >1 µm operation |
| UV Optimization | Optional UV-enhanced coatings |
| Power Supply | 24 V DC, peak 100 W |
| Dimensions (L×W×H) | 800 × 338 × 230 mm |
| Weight | 40 kg |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | Omni-λXi |
| Application Systems | Transmission/Reflection Spectroscopy |
| Grating Configuration | Triple-Grating Turret |
| Spectral Resolution | 0.35 nm (@1200 g/mm) |
| Linear Dispersion | 3.68 nm/mm |
| Wavelength Range | 400–1000 nm |
| F-number | f/1 |
| Wavelength Accuracy | ±0.25 nm (@1200 g/mm) |
| Stray Light | ≤0.1% (1×10⁻³) |
| Brand | ZOLIX |
|---|---|
| Model | Omni-λxxxD Series |
| Type | Dual-stage grating monochromator |
| Focal Length Options | 300 mm, 500 mm, or 750 mm per stage |
| Configuration Modes | Additive dispersion (high-resolution) and subtractive dispersion (low-stray-light) |
| Grating | 1200 g/mm standard |
| Slit Width | 0.01–3 mm (manual), motorized slit optional |
| Slit Height | 2 / 4 / 10 / 14 mm selectable |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Relative Aperture | F/3.9 (300 mm), F/6.5 (500 mm), F/9.7 (750 mm) |
| Linear Dispersion (1200 g/mm) | 1.35 / 2.7 nm/mm (Omni-λ300D, additive/subtractive) |
| Resolution (1200 g/mm) | 0.05 / 0.1 nm (Omni-λ300D, additive/subtractive) |
| Interface | USB 2.0 standard, RS-232 optional |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | OmniEvo |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OmniFluo |
| Price Range | USD 28,000–42,500 (FOB) |
| Dispersive Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm |
| Spectral Resolution | ±0.05 nm |
| Sensitivity | >3000:1 (Water Raman S/N ≥1000:1) |
| Wavelength Accuracy | ±0.15 nm |
| Spectral Range | 200–2500 nm |
| Excitation Sources | 150 W / 500 W Xenon Arc Lamp with Monochromator (Bandwidth 0.1–30 nm) |
| Optional Lasers | 266, 325, 375, 405, 442, 532, 785, 1064 nm |
| Detector Options | Cooled CCD (2000×256, 200–1000 nm), Cooled InGaAs Array (512×1, 800–2200 nm), PMT (200–870 nm), Cooled Single-Element InGaAs (800–2500 nm) |
| Signal Processing | Photon Counting or Lock-in Amplification |
| Optional Modules | Quantum Yield Measurement, Electroluminescence (EL), Cryogenic Sample Stage (≤10 K) |
| Emission Spectrum Correction | Built-in Absolute Intensity Calibration Function |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | OmniFluo Series |
| Price Range | USD 28,000 – 43,000 (FOB) |
| Dispersive Element | Holographic Grating & Interference Filters |
| Slit Width (Spectral Bandpass) | Adjustable, 0.1–5.0 mm |
| Spectral Resolution | 0.1 nm (FWHM @ 546.1 nm) |
| Sensitivity | 3000:1 (Signal-to-Noise Ratio, RMS, water Raman peak at 350 nm excitation, 5 nm bandwidth, 1 s integration) |
| Wavelength Accuracy | ±0.2 nm (Emission), ±0.25 nm (Excitation) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OmniFluo-FLIM Series |
| Dispersion Element | Grating |
| Instrument Type | Steady-State/Time-Resolved Fluorescence Spectrometer |
| Spatial Resolution | ≤1 µm @ 100× Objective @ 405 nm Picosecond Pulsed Laser |
| Spectral Range | 200–900 nm |
| Minimum Time Resolution | 16 ps |
| Fluorescence Lifetime Range | 500 ps – 1 µs |
| Instrument Response Function (IRF) | ≤2 ns |
| Excitation Sources | 375–670 nm Picosecond Pulsed Lasers (50 MHz Repetition Rate, Pulse Widths: 25–75 ps) |
| Microscope | Upright Research-Grade with Brightfield/Darkfield Illumination, 5-Position Objective Turret (10×/50×/100×), High-Definition CMOS Monitoring Camera |
| XY Stage | Motorized, 75 × 50 mm Travel, 50 nm Minimum Step, <1 µm Repeatability |
| Spectrograph | 320 mm Focal Length, Imaging-Corrected Monochromator, Triple 68 × 68 mm Gratings, Wavelength Accuracy: ±0.1 nm, Repeatability: ±0.01 nm, Slit Width: 0.01–3 mm Motorized |
| Detector Options | UV-Vis PMT (185–900 nm), Back-Illuminated Deep-Depletion CCD (2000 × 256 pixels, 15 µm × 15 µm, -60 °C Cooling) |
| TCSPC Module | Time Bins Down to 16 ps, Dead Time <10 ns, Up to 65,535 Histogram Channels, Instantaneous Saturation Count Rate: 100 Mcps |
| Software | OmniFluo-FM FLIM Acquisition & Analysis Suite (Multi-Exponential Fitting ≤4 Components, IRF-Free Fitting Modes, Pseudocolor Mapping, 3D Visualization, Line/Cross-Section/Histogram/Contour Tools) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | OmniFluo960 |
| Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm (excitation), 0.023–7 mm (emission) |
| Spectral Resolution | ≤ 0.08 nm |
| Sensitivity | Water Raman Signal-to-Noise Ratio ≥ 10,000:1 (at 350 nm excitation, 370–450 nm scan, 5 nm slit, 1 s integration) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Focal Length | 320 mm |
| Stray Light | ≤ 1×10⁻⁵ |
| Detector Options | CR131 (cooled red-sensitive PMT, 185–900 nm), R928, R13456, H10330C-75, R5509-73 |
| Standard Sample Chamber | SAC-FLS with cuvette, powder & solid sample holders |
| Automated Light Shield | Yes |
| Dark Count | ≤ 100 CPS (at –10°C) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Model | OmniFluo990 |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm (excitation), 0.023–7 mm (emission) |
| Spectral Resolution | 0.08 nm |
| Sensitivity | Water Raman Signal-to-Noise Ratio ≥ 10,000:1 |
| Wavelength Accuracy | ±0.2 nm |
| Lifetime Range | 500 ps – 10 s |
| Excitation Source | Gloria75X 75 W Xenon Arc Lamp |
| Emission Monochromator | Omni-λ3027i (f = 320 mm) |
| Stray Light | < 1×10⁻⁵ |
| Grating Options | 1200 g/mm BLZ@500 nm, 600 g/mm BLZ@750 nm, 300 g/mm BLZ@1250 nm |
| Detector | Cooled Red-Sensitive PMT CR131 (185–900 nm), Dark Count ≤ 100 CPS at –10 °C |
| Data Acquisition | DCS900PC TCSPC Module (Timing Resolution: 16 ps – 33.55 µs |
| Max Count Rate | 100 Mcps) |
| Software | ZolixScan v4.x (Steady-State Scanning, Time-Resolved Kinetics, TRES, QY Calculation, Spectral Correction, GLP-Compliant Audit Trail) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | OmniPL Series |
| Price Range | USD 28,000 – 42,500 |
| Dispersive Elements | Holographic Grating & Bandpass Filters |
| Slit Width (Spectral Bandpass) | Adjustable, 10–2000 µm |
| Spectral Resolution | < 0.2 nm (@ 1200 g/mm grating) |
| Signal-to-Noise Ratio | 3000:1 |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Excitation Source | HeCd Laser (325 nm, 20 mW) |
| Rayleigh Cutoff Filter | OD > 6 |
| Spectral Detection Range | 300–850 nm (expandable to 2500 nm) |
| Detector | Scientific-grade, thermoelectrically cooled back-illuminated CCD (300–1000 nm) |
| Optional Cryogenic Stage | Closed-cycle cryostat, 2 K minimum operating temperature |
| Software | Fully programmable acquisition protocol engine with spectral arithmetic, batch processing, and audit-trail logging |
| Brand | ZOLIX |
|---|---|
| Model | OmniPL-LF325 |
| Excitation Source | HeCd Laser (325 nm, 20 mW) |
| Rayleigh Cutoff Filter | OD > 6 |
| Spectral Range | 300–850 nm (extendable to 2500 nm) |
| Spectral Resolution | < 0.2 nm (@1200 g/mm grating) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Detector | Scientific-Grade Cooled Back-Illuminated CCD (300–1000 nm) |
| Cryogenic Compatibility | Optional Closed-Cycle Cryostat (down to 2 K) |
| Software | Customizable Acquisition Protocol, Spectral Arithmetic, Batch Processing, and GLP-Compliant Data Archiving |
| Brand | ZOLIX |
|---|---|
| Model | OmniPL-MicroS |
| Origin | Beijing, China |
| Manufacturer | ZOLIX Optics Co., Ltd. |
| Type | Integrated Micro-PL Spectrometer |
| Spectral Range | 200–1600 nm |
| Excitation Wavelengths (Optional) | 325, 405, 442, 473, 532, 633, 785 nm |
| Mapping Area | 50 mm × 50 mm (customizable) |
| Cryogenic Compatibility | Down to 10 K (with optional cryostat) |
| Software Features | Emission Spectrum Correction, Auto-Mapping, EL & Raman Expansion Modules |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | OmniPL-MicroS-A (Vertical-Path Configuration) |
| Price Range | USD 14,000 – 28,000 |
| Dispersive Element | Filter-Based Spectral Selection |
| Spectral Bandpass (Slit) | 200–1600 nm |
| Spectral Resolution | 0.1 nm |
| Sensitivity | >100:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.2 nm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | OmniRS-New |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–2500 nm |
| Spectral Resolution | 200–4000 cm⁻¹ (typical) |
| Spectral Bandwidth (FWHM) | ≤5 cm⁻¹ |
| Minimum Wavenumber Shift | 5 cm⁻¹ |
| Wavenumber Repeatability | < ±0.1 cm⁻¹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | PMEye-3000 |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Model | PMEye-3000 Series |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (Producer) |
| Laser Options | 266 nm, 405 nm, 442 nm, 532 nm, 785 nm (internal) |
| Mapping Speed | >20 points/sec |
| Spatial Resolution | 10 µm (objective mode), 50 µm (lens mode) |
| Spectral Resolution | 0.1 nm @ 1200 grooves/mm |
| Max Sample Size | 8-inch wafer |
| Spectrometer | 500 mm focal length, triple-grating DSP-scanning monochromator |
| Detector Options | Si photodiode (200–1100 nm), R1527 PMT (200–680 nm), CR131 PMT (200–900 nm), DSi300 Si detector (200–1100 nm), DInGaAs1700 RT InGaAs (800–1700 nm), DInGaAs1900 cooled InGaAs (800–1900 nm), DInGaAs2200 cooled InGaAs (800–2200 nm), DInGaAs2600 cooled InGaAs (800–2600 nm) |
| Wavelength Accuracy | ±0.2 nm (@ 300 nm, 1200 g/mm), ±0.6 nm (@ 500 nm, 600 g/mm), ±0.8 nm (@ 1250 nm, 300 g/mm) |
| XY Stage | 200 × 200 mm travel, <3 µm repeatability |
| Minimum Step Size | 1 µm |
| Data Acquisition | DCS300PA digitizer with preamplifier |
| Brand | ZOLIX |
|---|---|
| Model | PMTH Series |
| Cooling Type | Thermoelectric (TE) |
| Detector Type | Side-Window Photomultiplier Tube (PMT) |
| Compatible PMT Models | CR131, R928 |
| Spectral Range | 185–900 nm |
| Peak Wavelength | 400 ± 30 nm |
| Cathode Sensitivity (peak) | 74 mA/W |
| Peak Quantum Efficiency | 25.4% @ 260 nm |
| Gain | 1.0 × 10⁷ |
| Cathode Active Area | 8 × 24 mm |
| Cathode Luminous Sensitivity | 140–250 µA/lm |
| Anode Luminous Sensitivity | 1000–2500 A/lm |
| Typical Anode Dark Current | 3 nA |
| Max Anode Dark Current | 50 nA |
| Photocathode Material | Multi-alkali (S-20) |
| Dynode Structure | Box-and-Grid (9-stage) |
| Window Material | UV-Transmitting Glass |
| Anode Rise Time | 2.2 ns |
| Electron Transit Time | 22 ns |
| Cathode-to-Anode Voltage | 1250 V |
| Cathode-to-Last-Dynode Voltage | 250 V |
| Operating Ambient Temperature | −80 to +50 °C |
| Achievable Cooling Temperature | −10 °C (at 20–25 °C ambient) |
| Dark Count Rate (1 s integration, −10 °C) | 150–250 cps |
| HV Power Supply | Integrated, Low-Ripple, Adjustable Output |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PMTH-S1-(x) |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 100–4000 cm⁻¹ (laser-dependent) |
| Spectral Resolution | <2 cm⁻¹ (with 1800 gr/mm grating) |
| Spatial Resolution | ~100 µm (at 100 µm core fiber) |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | <±0.1 cm⁻¹ over 8-hour operation |
| Excitation Wavelengths | 405, 514, 532, 633, 670, 671, 785, 808 nm |
| Detector Options | ICCD (gate width <2 ns) or back-illuminated deep-depletion CCD |
| Collection Optics | Cassegrain telescope (f = 1000 mm, optional), Raman fiber probe (NA = 0.22), or custom long-working-distance optics |
| Laser Options | CW diode lasers (e.g., 785 nm, 100 mW) or Q-switched pulsed lasers (e.g., 532 nm, 290 mJ, 10 Hz) |
| Compliance | ASTM E1840, ISO/IEC 17025–compliant system architecture, FDA 21 CFR Part 11–ready data acquisition framework |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Remote Raman System |
| Pricing | Upon Request |
| Excitation Wavelengths | 405, 514, 532, 633, 670, 671, 785, 808 nm |
| Spectral Range | 100–4000 cm⁻¹ (laser-dependent) |
| Focal Length Options | 20–100 mm (probe), 1000 mm (telescope) |
| Spot Size | ~100 µm @ 100 µm core fiber |
| Working Distance | 20–100 mm (probe) |
| Numerical Aperture | 0.22 @ 40 mm focal length |
| Probe Dimensions | 2.25" L × 0.96" W × 0.58" H |
| Probe Housing Material | Hard-anodized aluminum or 316 stainless steel |
| Telescope Interface | FC/APC (laser), SMA (spectrometer) |
| Spectrometer Types | Czerny-Turner imaging-corrected (320 mm focal length, F/4.2) or VPH grating-based (85 mm focal length, F/1.8) |
| Spectral Resolution | <2 cm⁻¹ @ 1800 l/mm (CT), ~5 cm⁻¹ @ 1800 l/mm (VPH) |
| Detector Options | ICCD (1024×1024, 13 µm pixels, <2 ns gate width, 280–810 nm) or back-illuminated deep-depletion CCD (2000×256, 15 µm pixels, 200–1100 nm) |
| Laser Options | Pulsed Nd:YAG (532 nm, 290 mJ, 10 Hz) or CW diode (532/785 nm, 100 mW) |
| Optical Density of Notch Filters | OD >6 |
| Operating Temperature | 0–85 °C |
| Max Pressure Rating | 15 psi |
| Fiber Core | 100/100 µm standard (FC or SMA interface) |
| Brand | ZOLIX |
|---|---|
| Model | RTS Ultra |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Resolution | <0.65 cm⁻¹ @ 750 mm focal length spectrometer with 1800 grooves/mm grating |
| Spatial Resolution | ≤500 nm @ 532 nm laser excitation |
| Minimum Wavenumber | ≤10 cm⁻¹ (enabled by reflective volume holographic grating technology) |
| Excitation Wavelengths | 488 nm, 514 nm, 532 nm, 633 nm, 785 nm (wavelength-specific optical configurations required) |
| Detector Options | Back-illuminated deep-depletion CCD (−60 °C cooling), EMCCD, ICCD |
| Imaging Modes | Galvo-scanning and high-precision motorized stage scanning |
| Auto-focusing | Real-time hardware-synchronized focus tracking during spectral acquisition |
| Maximum Mapping Area | 80 mm × 60 mm with automated mosaic stitching and post-hoc ROI selection |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Model | RTS-II |
| Spectral Range | 300–1100 nm |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | Lateral 1 µm, Axial 2 µm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Integrated Lasers | 532 nm, 638 nm, 785 nm (fixed alignment, fiber-coupled) |
| Detector | Deep-cooled Raman-optimized CCD (QE >90% peak), expandable to EMCCD, ICCD, sCMOS, InGaAs array, or PMT |
| Optional Upgrades | Tunable CW laser (275–1100 nm), triple-stage spectrometer, TCSPC, fast-gating ICCD (25 kfps, ~40 µs time resolution), dark-field scattering, micro-transmission/reflection, FLIM |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | RTS-LIBS |
| Pricing | Upon Request |
| Spectral Range | 200–850 nm (customizable bands available) |
| Spectral Resolution | <0.05 nm @ 1200 g/mm grating |
| Spatial Resolution | Lateral: <500 nm @ 532 nm excitation laser |
| Axial | <2 µm @ 50 µm pinhole, 532 nm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RTS-LTRS |
| Spectral Resolution | <2 cm⁻¹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | RTS-SEMR |
| Quotation | Upon Request |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution | Lateral: <500 nm @ 532 nm laser |
| Axial | <2 µm @ 50 µm pinhole, 532 nm laser |
| Brand | ZOLIX |
|---|---|
| Model | RTS2 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 300–1100 nm |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | Lateral ≤1 µm, Axial ≤2 µm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Repeatability | ±0.1 cm⁻¹ |
| Laser Options | Integrated 532 nm DPSS (TEM₀₀, 100 mW), 638 nm & 785 nm diode lasers |
| Spectrometer | 328 mm focal length, four-grating turret (1800, 600, 150 l/mm + optional fourth grating) |
| Detector | 2000 × 256-pixel deep-cooled Raman-optimized CCD (QE >90% at peak), EMCCD/PMT upgradeable |
| Confocal Modes | Slit-CCD confocal and fiber-pinhole confocal (switchable) |
| Mapping Capability | Motorized XY stage with 2D Raman mapping (1 µm step resolution) |
| SNR | >20:1 (Si third-order peak) |
| Optional Accessories | Ultra-low wavenumber module (10 cm⁻¹), dark-field scattering spectroscopy, in-situ 2D photoluminescence (PL) and Raman co-mapping |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | RTS2 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 80–9000 cm⁻¹ (532 nm excitation), 80–6000 cm⁻¹ (638 nm excitation), 80–3500 cm⁻¹ (785 nm excitation) [typical] |
| Spectral Resolution | <1.5 cm⁻¹ FWHM @ 585 nm (1800 l/mm grating) |
| Spatial Resolution | <1 μm (XY), <2 μm (Z) |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |