Chemical Analysis Instruments
Filter
Showing 1051–1080 of 4337 results
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MPG-2XX |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±40 A |
| Current Accuracy | ±20 nA on 10 μA |
| Potential Accuracy | <5 mV on ±2.5 V |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz – 1 MHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MPG2 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±10 A (per channel with optional high-current modules) |
| Current Resolution | 760 pA |
| Potential Accuracy | ±5 µV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 20 kHz |
| Data Acquisition Rate | 200,000 points/s |
| Channels | 16 independent, fully isolated |
| Voltage Resolution | 300 µV (dynamic range adjustable down to 5 µV) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | SFM-100+MOS-LED |
| Instrument Architecture | Single-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 180–820 nm |
| Wavelength Accuracy | ±0.1 nm |
| Spectral Bandwidth | 0–16 nm (adjustable) |
| Stray Light | ≤2 ppm |
| Dead Time | 5 ms (motor-driven), 8 ms (manual) |
| Sample Consumption per Experiment | 30 µL |
| Mixing Chamber Dead Volume | 20 µL |
| Mixing Ratio | Variable |
| Control Interface | USB |
| Detection Modes | Standard Absorbance (default), optional Fluorescence and Dual-Absorbance modes |
| Software | Spec-Lab v5.x |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SFM-3000 |
| Number of Syringes | 3 |
| Drive Mechanism | Stepper Motor per Syringe |
| Minimum Dead Time | 0.25 ms (microcell) / 0.6 ms (FC-08 cell) |
| Flow Rate Range | 0.01–10 mL/s |
| Mixing Ratio Range | 1:1 to 1:100 (continuously adjustable) |
| Temperature Control | Jacketed Cell with External Circulator |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-150e |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | Dual-Channel |
| Current Range | ±1 A |
| Current Resolution | 760 pA (optional 76 fA) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Voltage Resolution | 300 μV (dynamically adjustable down to 5 μV) |
| Data Acquisition Rate | 200,000 points/s |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-200 |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±500 mA |
| Current Resolution | 76 aA |
| Potential Accuracy | ±0.1% of full scale |
| Potentiostatic Range | ±12 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Voltage Resolution | 1 µV (dynamic range adjustable down to 1 µV) |
| Data Acquisition Rate | 1,000,000 points/second |
| Optional ULC Module | 100 pA (down to 1 pA) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-300 |
| Channel Count | Dual-channel |
| Current Range | ±500 mA |
| Current Resolution | 76 aA |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±48 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Data Acquisition Rate | 1,000,000 pts/s |
| Voltage Resolution | 1 µV (dynamic range adjustable) |
| Optional Modules | ULC (1 pA), High-Current (4 A/14 V), High-Voltage (1 A/48 V) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-50e |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±20 nA (on 10 μA range) |
| Potential Accuracy | <5 mV (on ±2.5 V range) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Current Resolution | 760 pA |
| Voltage Resolution | Adjustable from 300 μV down to 5 μV |
| Data Acquisition Rate | 200,000 points/s |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Uniscan M370 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±1 A |
| Current Accuracy | ±0.1% of reading |
| Potential Accuracy | ±10 mV |
| Potentiostatic Range | ±20 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VMP-300 |
| Number of Channels | 16 |
| Current Range | ±500 mA |
| Current Accuracy | ±0.1% |
| Potential Accuracy | ±0.1% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Voltage Compliance | ±12 V |
| Control Voltage Range | ±10 V |
| Current Resolution (standard board) | 760 fA |
| Floating Mode | Yes |
| Analog Filtering | Built-in |
| Calibration Board | Integrated |
| Control Stability | Digital PID with adaptive tuning |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VMP-3e |
| Channel Count | 16 independent channels |
| Current Range | 76 fA to 100 A (with external amplifiers) |
| Current Accuracy | ±0.1% |
| Potential Range | ±10 V (DC), 0–20 V (galvanostatic mode) |
| Potentiostatic Range | ±20 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Data Acquisition Rate | 200,000 points/sec |
| Potential Resolution | 300 µV (dynamic range adjustable down to 5 µV) |
| Switching Time (Potentiostatic ↔ Galvanostatic) | <10 µs |
| Input Impedance | >10^14 Ω |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP |
| Channel Count | 5 independent channels |
| Current Range | 1 nA to 100 A (with external amplifier) |
| Current Resolution | 76 fA |
| Potential Accuracy | ±5 µV |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±4 A (built-in), up to ±100 A (with external current booster) |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Data Acquisition Rate | 200,000 points/s |
| Voltage Resolution | 300 µV (dynamic adjustment down to 5 µV) |
| Supported Techniques | CV, LSV, CA, CP, EIS (potentiostatic/galvanostatic/step-mode), DPV, SWV, NPV, Mott-Schottky, ZRA/ZVC, corrosion polarization, GITT, PITT, constant-power discharge, potentiometric titration, and multi-step sequence protocols |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP-300 |
| Channel Count | 6 |
| Current Range | ±500 mA |
| Current Resolution | down to 76 aA (with ULC option) |
| Current Accuracy | ±20 nA on 10 µA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±1 A (extendable to ±20 A) |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Sampling Rate | up to 1 µs |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Software | EC-Lab® v12+ with FDA 21 CFR Part 11-compliant audit trail option |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP-3e |
| Channel Count | 8 |
| Current Range | ±1 pA to ±1 A |
| Current Accuracy | ±0.0033% of reading |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±10 V (adjustable up to ±20 V) |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Voltage Resolution | 5 µV (within ±200 mV range) |
| Current Resolution | 0.76 nA |
| Minimum Sampling Interval | 200 µs |
| Control Bandwidth | 7 adjustable bandwidths |
| Connectivity | Ethernet (LAN), USB, optional EIS module |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | BioLogic DuoFlow System |
| Maximum Pressure | 3500 psi (23 MPa) |
| Flow Rate Range | 0.01–80 mL/min (configurable via pump head selection) |
| UV Detection Wavelengths | Fixed 254/280 nm |
| Conductivity Range | 1–500 mS/cm |
| UV Sensitivity | 0.0001–2.0 OD |
| Fraction Collection Modes | Time-based (0.03–999 min), Drop-based (0–9999 drops), Volume-based, Large-volume (20 positions, up to 500 mL each) |
| Temperature-Controlled Operation | Compatible with chromatography cold cabinets (4–10 °C) |
| System Biocompatibility | Fully bio-inert fluidic path (PEEK, titanium, sapphire, fused silica) |
| Software Platform | BioLogic System Controller v5.x (Windows-based, FDA 21 CFR Part 11 compliant audit trail option) |
| Brand | Biochrom |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biochrom 30+ |
| Price Range | USD 92,000 – 132,000 (based on exchange rate and configuration) |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0–130 mL/hr |
| Maximum Pump Pressure | 45 MPa |
| Autosampler Injection Volume | 1–5000 µL |
| Autosampler Temperature Control | 4 °C to ambient, continuously adjustable |
| Post-Column Reactor Temperature Range | 40–145 °C |
| Detection Wavelengths | 570 nm and 440 nm (dual-wavelength, self-calibrating, parallel signal output with summation capability) |
| Flow Cell Volume | 8 µL |
| Brand | BioLight |
|---|---|
| Model | Lux-T020 |
| Origin | Guangdong, China |
| Detector Type | Electrochemiluminescence & Bioluminescence Luminometer |
| Photomultiplier Tube (PMT) | Single-Photon Counting PMT |
| Max Count Rate | >100 million pulses/sec |
| Detection Sensitivity | ≤10 amol ATP or 20 zmol firefly luciferase |
| Dynamic Range | 7 decades (linear) |
| Sample Format | 12 × 55 mm test tubes or standard 0.5–2.0 mL microcentrifuge tubes |
| Interface | Touchscreen GUI with USB data export |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Biopharma |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Lyotherm3 |
| Pricing | Available Upon Request |
| Brand | Biopharma |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Micropress |
| Pricing | Available Upon Request |
| Brand | Bioseps |
|---|---|
| Origin | Tianjin, China |
| Model | DAC100/150 (Single-Column Configuration) |
| Instrument Type | Dynamic Axial Compression (DAC) System |
| Sealing Technology | High-Pressure Spring-Energized PTFE-Coated O-Ring Seal |
| Column Connection | C-Clamp Quick-Release Bottom Endcap |
| Pressure Actuation | Hydraulic Jack with Pneumatic Control Option for Hazardous Environments |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | AS30 |
| Instrument Type | Thin-Layer Chromatography (TLC) Sample Spotter |
| Spotting Method | Non-contact spray spotting with programmable overlap capability |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | <0.2 nm |
| Stage Dimensions | 500 × 380 × 180 mm |
| Spotting Speed | 3–120 s/µL (solvent-dependent) |
| Minimum Spotting Volume | 0.1 µL |
| Volume Range Options | 0.1–10 µL and 0.1–100 µL |
| Spotting Precision | ±0.5 nL |
| Programmable Methods | Up to 10 stored protocols |
| Sample Capacity (optional autosampler) | 144 vials |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | CD60 |
| Instrument Type | HPTLC Densitometer |
| Operation Mode | Fully Automated |
| Detection Modes | Absorption, Reflection, Fluorescence, Transmission |
| Wavelength Range | 190–900 nm |
| Light Sources | Deuterium Lamp, Tungsten-Halogen Lamp, Mercury Lamp |
| Monochromator | Stepper Motor-Driven Holographic Grating (1200 lines/mm) |
| Spectral Bandwidth | 5–260 nm |
| Wavelength Accuracy | < ±0.1 nm |
| Wavelength Repeatability | < ±0.2 nm |
| Minimum Spatial Resolution | 0.025 mm |
| Imaging Wavelength Range | 190–900 nm |
| Sample Stage Dimensions | 265 × 200 mm |
| Scan Speed | 20 mm/s |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | SG1 / DS20 |
| Spray Method | Programmable, Quantitative, Region-Specific Aerosol Deposition |
| Droplet Size | 1–10 µm |
| Spray Platform Area | 20 × 20 mm |
| Scan Speed | 50–200 mm/s |
| Wavelength Range | 2–4 mm (Note: This value is physically inconsistent with optical spectroscopy |
| likely refers to spray nozzle orifice diameter — corrected to “Nozzle Orifice | 2–4 mm”) |
| Light Sources | Deuterium lamp, Tungsten-halogen lamp, Mercury lamp |
| Wavelength Reproducibility | < 0.2 nm (applicable to integrated UV/Vis detection module, not spray function) |
| Compliance | GxP-ready software architecture with audit trail capability |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | DD80 |
| Instrument Type | Automated TLC Imaging & Densitometry System |
| Operation Mode | Fully Automatic |
| Detection Mode | Low-Fluorescence Substance Imaging |
| Wavelength Options | 254 nm and 366 nm UV |
| Light Sources | White LED, UV Fluorescent Lamps, UV LEDs |
| Imaging Sensor | 24-Megapixel Full-HD Digital Camera |
| Spectral Bandwidth Management | Auto Background Correction & Real-Time Image Optimization |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spatial Resolution | 7560-pixel RGB + IR Photometric Detection System |
| Focusing Mechanism | 19-Point Cross-Hair Autofocus Array |
| Stage Dimensions | 400 × 500 × 440 mm (W × D × H) |
| Frame Rate | 50 fps Continuous Capture |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera Dalton 2000 |
| Application Level | Laboratory |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.2% |
| Maximum Operating Pressure | 145 psi |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ≤ 2 × 10⁻⁵ AU (peak-to-peak, methanol, 1 mL/min, 254 nm, 20 °C) |
| Data Acquisition Rate | 10 Hz |
| Mass Range | m/z 80–2000 |
| Ionization Modes | Simultaneous Positive/Negative APCI (ESI optional) |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera LS |
| Application Level | Laboratory-scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 50–500 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.2% |
| Maximum Operating Pressure | 145 psi (10 bar) |
| Wavelength Range | 200–400 nm (standard UV), optional 200–800 nm (UV-Vis) |
| Wavelength Reproducibility | ±0.1 nm |
| Baseline Noise | ≤2×10⁻⁵ AU (peak-to-peak, methanol, 1 mL/min, 254 nm, 20 °C) |
| Data Acquisition Rate | 10 Hz |
| Brand | BioTools |
|---|---|
| Origin | USA |
| Model | ChiralIR-2X |
| Instrument Type | Vibrational Circular Dichroism (VCD) Spectrometer |
| Spectral Range | 4000–850 cm⁻¹ (standard), optional extension to 10,000 cm⁻¹ (NIR) |
| Baseline Drift | < 2 × 10⁻⁵ AU |
| Signal-to-Noise Ratio | >3.6× improvement over single-source systems |
| Detector Continuous Operation | 30–48 hours |
| Optical Path | Fully automated alignment and calibration |
| Data Acquisition | Digital signal processing (no lock-in amplifiers or analog filtering required) |
| Sample Stage | SyncRoCell™ rotating sample cell platform |
| DualPEM™ capability | Optional upgrade for solid-sample VCD correction |