| Brand | AECS |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QuickPrep |
| Pricing | Upon Request |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AFX1000-IR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment Mode | Ground-based & UAV-mounted |
| Spectral Range | 400–1000 nm (HSI) + 8–14 µm (LWIR) |
| Thermal Imaging Resolution | 640 × 512 pixels (full-frame radiometric temperature mapping) |
| Frame Acquisition Rate | ≥300 Hz (full spectral cube acquisition) |
| Total Field of View (TFOV) | 30.5° |
| Instantaneous Field of View (IFOV) | 2.7 mrad |
| RGB Camera | 26 MP synchronized capture |
| System Mass | <2.5 kg |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AFX1700-IR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based and UAV-mounted |
| Spectral Range | 900–1700 nm (VNIR/SWIR HSI) + 8–14 µm (LWIR thermal) |
| Thermal Spatial Resolution | 640 × 512 pixels (full-frame radiometric temperature mapping) |
| Maximum Data Acquisition Rate | ≥500 Hz across full spectral bands |
| Total Field of View (TFOV) | 35.5° |
| Instantaneous Field of View (IFOV) | 3.5 mrad |
| RGB Camera Resolution | 26 MP |
| System Mass | <2.5 kg |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EM38-MK2 |
| Detection Parameters | Dual-frequency electromagnetic induction (EC and magnetic susceptibility) |
| Portability | Airborne & Ground-portable |
| Application Environment | Field-deployable for aerial and terrestrial geophysical surveys |
| Electrical Conductivity Range | 0–1000 mS/m (4-digit resolution) |
| TDS Equivalent Range | ±28 ppt at 1-m coil separation |
| Accuracy | ±0.1% of full scale |
| Coil Separations | 1.0 m and 0.5 m (dual independent dipole receivers) |
| Operating Frequency | 14.5 kHz |
| Weight | 5.4 kg |
| Compliance | Designed for ISO 11277-compliant soil characterization workflows and ASTM D6439-22 (Standard Guide for Use of Electromagnetic Induction Methods in Geotechnical Investigations) |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Hyper-Cam |
| Pricing | Available Upon Request |
| Operating Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Imaging Architecture | Dispersive (Grating-Based) |
| Deployment Mode | Ground-Based & Airborne Compatible |
| Spectral Range | 7.7–12.5 µm (MWIR) |
| Spectral Resolution | Up to 0.25 cm⁻¹ |
| Spatial Resolution (IFOV) | 0.45 mrad (typical, lens-dependent) |
| Detector Format | 320 × 256 HgCdTe FPA |
| Field of View (TFOV) | 6.4° × 5.1° |
| Frame Rate | Up to 60 Hz (full-frame, binning-dependent) |
| Calibration | Onboard Blackbody + Ambient Reference |
| Compliance | ISO/IEC 17025-aligned calibration traceability, GLP-compliant data acquisition workflow |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NSpec |
| Energy Resolution | ≤ 1.85 keV @ 1.33 MeV |
| Relative Efficiency | 20% @ 1.33 MeV (vs. 3"×3" NaI, Co-60, 25 cm) |
| Resolution @ 122 keV | ≤ 875 eV |
| Peak-to-Compton Ratio | ~51:1 |
| FWTM/FWHM | 1.9 |
| FWFM/FWHM | 2.65 |
| Energy Range | 40–3000 keV |
| Cooling Method | Liquid Nitrogen Cryogenic |
| Form Factor | Integrated Miniaturized Unit (Detector + Dewar + MCA + Display) |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RedEdge-P |
| Pricing | Available Upon Request |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | X20P-IR |
| Spectral Range | 350–1000 nm (VNIR) + 7.5–13.5 µm (LWIR) |
| Spectral Resolution | 164 bands (VNIR), 640 × 512 pixels (LWIR) |
| Spatial Resolution | 1886 × 1886 pixels per hyperspectral cube |
| Frame Rate | 2 cubes/s |
| Field of View (TFOV) | 35° |
| Instantaneous Field of View (IFOV) | < 1.5 mrad (typ.) |
| Imaging Modality | Snapshot-based dispersive hyperspectral imaging with concurrent uncooled microbolometer LWIR imaging |
| Platform Compatibility | Ground-based tripod mounting and UAV-integrated operation (multirotor & fixed-wing) |
| Integrated Stabilization | Brushless gimbal with SkyPort digital interface |
| Onboard Storage | Embedded solid-state storage |
| Data Synchronization | Hardware-triggered, frame-locked VNIR/LWIR acquisition |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Model | X20P-LIR |
| Spectral Range | 350–1000 nm (VIS-NIR) + 905 nm (LiDAR) + 7.5–13.5 µm (MWIR/LWIR) |
| Spectral Resolution | ≥2 cubes/s (1886 × 1886 pixels per cube) |
| Spatial Resolution (IFOV) | ≤0.008° |
| Field of View (TFOV) | 0.008° |
| Frame Rate | ≥2 hyperspectral cubes per second |
| Image Format | 1886 × 1886 pixels per spectral cube |
| Thermal Imaging | 640 × 512 uncooled microbolometer, radiometrically calibrated |
| LiDAR Range | 450 m (@80% reflectivity) |
| Platform Compatibility | UAV-mounted (ground & airborne operation) |
| Onboard Systems | Integrated IMU, real-time georeferencing engine, solid-state storage, embedded control unit |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Model | X20P-LV |
| Spectral Range | 350–1000 nm (hyperspectral) + 905 nm (LiDAR) |
| Spatial Resolution | 1886 × 1886 pixels per hyperspectral cube |
| Frame Rate | 2 cubes/s |
| Spectral Channels | 164 (expandable) |
| LiDAR Range | 450 m (@ 80% reflectivity) |
| LiDAR Accuracy | ±2 cm (1σ @ 20 m) |
| FOV | 0.008° |
| IFOV | 2 cubes/s, 1886 × 1886 pixels/cube |
| IMU Accuracy | Heading ±0.038°, Attitude ±0.008° |
| Data Interface | 2× GigE, 2× USB, HDMI |
| Onboard Storage | 256 GB SSD + 8 GB RAM |
| Sensor Configuration | 20 MP hyperspectral CMOS + 3.5 MP panchromatic sensor + solid-state 905 nm LiDAR |
| Brand | Aerodyne |
|---|---|
| Origin | USA |
| Model | Aerodyne N2O |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer (IRMS) Equivalent |
| Detection Principle | Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) |
| Measurement Targets | N₂O, δ¹⁵Nα (¹⁵N¹⁴N¹⁶O), δ¹⁵Nβ (¹⁴N¹⁵N¹⁶O), δ¹⁸O (N₂O) |
| Detection Limit | <1 ppt (v/v) for N₂O |
| Temporal Resolution | 1–10 Hz (configurable) |
| Path Length Options | 76 m or 400 m multipass cell |
| Precision (100 s) | δ¹⁵Nα ≤ 0.08‰, δ¹⁵Nβ ≤ 0.5‰, δ¹⁸O ≤ 0.5‰ |
| Operating Temperature Range | 10–35 °C (ambient) |
| with thermostatic enclosure | −20 to +40 °C |
| Temperature Stability | ±0.1 °C at setpoint (typically 30 °C) |
| Power Requirement | 500 W, 120/240 VAC, 50/60 Hz (pump excluded) |
| Dimensions (76 m) | 650 × 430 × 270 mm (W×D×H) |
| Weight | 35 kg |
| Dimensions (400 m) | 560 × 770 × 640 mm |
| Weight | 75 kg |
| Sampling Flow Rate | 0–20 slpm |
| Data Interfaces | RS-232, USB, Ethernet |
| Time Synchronization | GPS-enabled NTP server support |
| Brand | Aerodyne |
|---|---|
| Origin | USA |
| Instrument Type | Stable Isotope Ratio Mass Spectrometry (IRMS)-Grade Laser Absorption Spectrometer |
| Measurement Principle | Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) with Astigmatic Multipass Cell |
| Detection Limits | Sub-ppt for N₂O, CH₄ |
| δ¹³C-CO₂ precision | 0.02‰ (120 s) |
| δ¹⁸O-CO₂ precision | 0.03‰ (120 s) |
| Sampling Frequency | 1–10 Hz configurable |
| Certified Compliance | ASTM D6348, ISO 13877 (adapted), GLP/GMP-ready data audit trail per FDA 21 CFR Part 11 |
| Software | TDLWINTEL v5.2 with HITRAN spectral replay, zero-spectrum background subtraction, real-time laser frequency stabilization, and passive cavity drift correction |
| Brand | AES |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CEInfinite |
| Voltage Input | 100/240 VAC, 50–60 Hz |
| Cooling Method | Liquid-based Thermostatic Control |
| Sample Temperature Range | 4–10 °C |
| Detector | Scientific CMOS (sCMOS) Imaging Sensor |
| Separation Mode | Voltage Gradient iCIEF |
| Sample Introduction | Automated Capillary Injection |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AG1000-F |
| Pricing | Upon Request |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC 600DID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity (UHP) Gas Analysis |
| Oven Temperature Range | 5°C above ambient to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increments) |
| Oven Cool-Down | 300°C to 50°C in ≤5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Maximum Temperature | 450°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NC1000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity Semiconductor Gas Analysis |
| Temperature Control Range | 0–300 °C |
| Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cool-down Time | ~5 min (300 °C → 50 °C) |
| Carrier Gas Flow Range | 0–900 mL/min |
| Carrier Gas Pressure Range | 0–700 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–700 kPa |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Detector | Pulsed Helium Discharge Ionization Detector (DID) |
| Detection Range | ppb to % level |
| Accuracy | ±1% of full scale |
| Response Time (90%) | 0.5 s |
| Warm-up Time | 60 min |
| Display | 6.5″ color LCD with resistive touchscreen |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack-mount, 5U) |
| Weight | 25 kg |
| Carrier Gas | Ultra-high-purity helium (N6.0, 20–60 mL/min) |
| Sample Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Dry, oil-free air at 300 kPa |
| Electronic Pressure/Flow Control | 0–5 bar output (5–10 bar input) |
| Output Signals | 0–1 V analog |
| Compliance | Designed for ASTM D7527, ISO 8573-5, IEC 61511, and aligned with USP <621>, FDA 21 CFR Part 11 data integrity requirements for electronic records |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM 1000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Impurity Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Temperature Stability | < ±0.05 °C/h (after 30 min warm-up) |
| Cooling Rate | 300 °C to 50 °C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Max Temperature | 300 °C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM 1000 DID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Dedicated to High-Purity Hydrogen Analysis |
| Temperature Control Range | +5 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (0.1 °C increments) |
| Cool-down Time | ~5 min (300 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–700 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–700 kPa |
| Injector Total Flow Setpoint Range | 10–500 mL/min |
| Detector | Helium Ionization Detector (DID) |
| DID Measurement Range | ppb to % level |
| DID Accuracy | ±1% of full-scale reading |
| DID Operating Temperature | 30–45 °C |
| Ambient Operating Temperature | 10–30 °C |
| DID Response Time (90%) | 0.5 s |
| DID Warm-up Time | 60 min |
| Display | 6.5″ color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity helium (He, N6.0), 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 300 kPa (3 bar) |
| Electronic Gas Control | 5–10 bar input → 0–5 bar regulated output |
| Standard Fittings | 1/8″ stainless steel Swagelok® and VCR |
| Output Signal | 0–1 V analog |
| Alarm Outputs | Detector, system, flow, maintenance, temperature, pressure |
| Data Interface | TrendVision PLUS with 4–20 mA, Profibus, Modbus, RS-485 |
| Power Supply | 220 V AC |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack, 5U) |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC100 Series |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Oven Temperature Range | +5–450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cooling Rate | 300–50 °C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–700 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| DID Operating Temp | 30–45 °C |
| Ambient Temp Requirement | 10–30 °C |
| Response Time (90%) | 0.5 s |
| Warm-up Time | 60 min |
| Display | 6.5″ color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity helium (He, N6.0), 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 300 kPa |
| Electronic Gas Control | Input 5–10 bar, output control 0–5 bar |
| Output Signal | 0–1 V analog |
| Communication | 4–20 mA, Profibus, Modbus RTU, RS-485 via TrendVision PLUS |
| Power Supply | 220 V AC |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack, 5U) |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM1000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Impurity Analysis |
| Oven Temperature Range | 4°C to 450°C |
| Temperature Stability | < ±0.05°C/h (after 30 min warm-up) |
| Cooling Rate | 300°C → 50°C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Maximum Temperature | 300°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NovaCHROM2000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal for Ultra-High-Purity Gas Analysis |
| Temperature Control Range | 5°C above ambient to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increment) |
| Cooling Rate | 1°C/sec (typical, from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–40 mL/min (EPC-controlled) |
| Carrier Gas Pressure Range & Control | 0–600 psi (EPC-controlled) |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–200 psi |
| Injector Total Flow Setting Range | 100–300 mL/min |
| Detector Options | ADD (Argon Discharge Detector), DID (Dielectric Barrier Discharge Ionization Detector), TCD, FID, FPD |
| Detection Limit | Sub-ppb to ppm level |
| Accuracy | ±1% of full scale |
| Response Time | 0.5 s (to 90% of final signal) |
| Warm-up Time | ≤60 min |
| Display | 6.5" color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity argon (Ar, N6.0, 99.9999% purity), flow 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 3 bar (300 kPa) |
| Electronic Pressure Control Input | 5–10 bar |
| Output Control Range | 0–5 bar |
| Standard Fittings | 1/8" stainless steel Swagelok® and VCR |
| Analog Output | 0–1 V (detector, system status, flow, maintenance, temperature, pressure) |
| Data Interface | TrendVision PLUS with 4–20 mA, Profibus, Modbus RTU, and RS-485 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (Rack Mount) | 19" (483 mm) W × 5U (219 mm) H × 22" (564 mm) D |
| Dimensions (Free-Standing) | H=900 mm, W=600 mm, D=400 mm |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NP9000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Temperature Control Range | +5°C to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increments) |
| Cooling Rate | 300°C to 50°C in ~5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–700 kPa |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Explosion Protection Rating | Ex pxb IIB+H2 T3 Gb |
| Column Oven Configuration | Multiple Independent Temperature-Controlled Ovens |
| Display | 12" Industrial Capacitive Touchscreen |
| Data Output Interfaces | 4–20 mA, Profibus, Modbus, Ethernet |
| Detector Options | DID, FID, TCD, FPD, PID, ADD |
| Column Types Supported | Packed, Micro-packed, Capillary |
| Valve Types | Stainless Steel / Hastelloy VICI Valco (4-, 6-, 8-, or 10-port) |
| Enclosure Material | Low-Carbon Steel with Front Safety Door |
| Gas Line Fittings | 1/8" Swagelok® or VCR (Hastelloy optional) |
| Operating Ambient Temperature | −10°C to +50°C |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ACQ-06 |
| Pricing | Available Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ASTRA |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi |
| UV-Vis Detection | PDA Detector, 200–800 nm |
| Gradient Capability | Quaternary Solvent Selection |
| Column Compatibility | Normal- & Reversed-Phase Columns (4–800 g), Max. Sample Load: 80 g |
| Fraction Collection Modes | Full Collection, Peak-Based Collection, Manual Trigger, Time-Window Collection |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | ATS-051 |
| Instrument Type | Preparative HPLC/LC Autosampler |
| Maximum Sample Capacity | 5 vials |
| Minimum Sample Volume per Injection | 1 mL |
| Loop Volume Range | 2–20 mL |
| Positioning Accuracy | ±0.1 mm (verified by encoder feedback) |
| Drive Mechanism | Precision Syringe Pump |
| Needle Wash | Integrated Solvent Flush with Dual-Path Solvent Selection |
| Repeat Injection Capability | Unlimited cycles per sample |
| Maximum Single Injection Volume | 50 mL |
| Compatibility | Standalone operation or integration with third-party preparative LC systems (e.g., Gilson, Biotage, Teledyne ISCO, Shimadzu, Waters) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | ATS-A5 |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Capacity | 108 × 2 mL vials (standard), optional configurations available |
| Injection Modes | Full-loop, Partial-loop, and Needle-in-Loop (NIL) injection |
| Injection Volume Range | 0.1–25 µL (with standard loop) |
| Precision | RSD < 0.25% (full-loop), < 0.5% (partial-loop, >10 µL), < 0.8% (NIL, <5 µL) |
| Carryover | < 0.05% |
| Maximum System Pressure | 40 MPa (standard HPLC), 60 MPa (UHPLC-compatible) |
| Safety Features | Vial-missing detection, needle-strike alarm, tubing blockage detection, leak monitoring |
| Optional | Peltier-based sample cooling module |
| Dimensions (W×D×H) | 300 × 450 × 320 mm |
| Weight | ~25 kg |
| Brand | Agela |
|---|---|
| Model | CC-100 |
| Origin | Tianjin, China |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Stability | ±0.1°C |
| Temperature Uniformity | ±0.3°C (across chamber) |
| Control Method | PID digital control with touch keypad |
| Display | LED digital display |
| Safety Features | Over-temperature protection cutoff |
| Chamber Design | Vertical upright configuration with magnetic-latch dual-layer lid (outer magnetic cover + insulated inner cover) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 260 × 320 × 380 mm |
| Net Weight | 8.5 kg |
| Cooling | None (heating-only operation) |
| Brand | Agela |
|---|---|
| Model | CHEETAH HP100 / Agela cMS |
| Instrument Type | Single Quadrupole LC-MS |
| Mass Range | m/z 10–1200 |
| Sensitivity | S/N ≥ 100:1 (100 pg reserpine, full scan |
| Resolution | 0.5–0.7 Da (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Mass Stability | ±0.1 Da |
| ESI Ion Source | Standard |
| Polarity | Positive/Negative Switchable |
| Scan Speed | 5000 Da/sec (UPLC-compatible) |
| Flow Rate Compatibility | 10–100 µL/min |
| HPLC/Purification Pump Flow Range | 0.1–100 mL/min |
| Max Pressure | 20 MPa |
| UV Detection | 200–400 nm (D₂ lamp), optional 200–800 nm (D₂ + W lamp) |
| Wavelength Accuracy | ±1 nm |
| Bandwidth | 8 nm |
| Flow Precision | ±1% |
| Flow RSD | ≤0.3% |
| Pressure Pulsation | ≤0.3 MPa |
| Fraction Collector | 2D robotic, customizable coordinates, tube sizes: 13/15/18/25 mm |
| Operating System | Windows XP (industrial-grade PC) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH II |
| Instrument Type | Fast Liquid Chromatography (Flash) |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi |
| Sample Injection Positions | 1–100 |
| Injection Volume Ratio | 1–10% |
| Temperature Control | 25°C (ambient, non-thermostatted) |
| Wavelength Range | 200–800 nm |
| Data Acquisition Frequency | Not specified (system supports real-time UV/VIS spectral scanning) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH MP200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative HPLC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm (standard detector), 200–800 nm (optional dual-range detector) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±1 nm |
| Baseline Noise | ≤3×10⁻⁴ AU |
| Data Acquisition Rate | 3 Hz |
| Gradient Configuration | Binary or Quaternary |
| Detection Modes | Single-Wavelength, Dual-Wavelength (independent collection & monitoring), Ratio-Based Triggering |
| Fraction Collection | Integrated 2D Fraction Collector with Adjustable Rack Mapping |
| Solvent Compatibility | All Common HPLC-Grade Organic and Aqueous Solvents |
| Safety Features | Real-Time Pressure Monitoring, Leak Detection with Audible/Visual Alert |