BrandAliben
OriginSichuan, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelUVP-TOF MS 2000 LITE
Detection PrincipleVacuum Ultraviolet Photoionization (VUV-PI) coupled with Time-of-Flight Mass Spectrometry
Instrument TypeOnline Analyzer
ConfigurationMulti-Component VOC & Inorganic Gas Monitor
Detection Range0–1 ppbv (extendable to % v/v)
Mass Resolution (FWHM)>2000
AccuracyRSD <3%
Response Time<1 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAliben
OriginSichuan, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryDomestic
ModelUVP-TOF MS 2000 PLUS
Detection PrincipleVacuum Ultraviolet Photoionization + Time-of-Flight Mass Spectrometry
Instrument TypeOnline Analyzer
ConfigurationMulti-Component VOC Monitor
Sampling MethodDirect Gas Inlet
Detection Range100 pptv – 1 ppmv
Mass Resolution (FWHM)>2500
Accuracy (RSD)<3%
Response Time<0.5 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAliben
OriginSichuan, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic Instrument
ModelPTR-TOF MS 6000
Detection PrincipleProton Transfer Reaction (H₃O⁺-based soft ionization)
Instrument TypeOnline Real-time Analyzer
ConfigurationIntegrated VOCs Monitoring System
Mass Resolution (m/Δm)≥ 6,000 (FWHM at m/z 100)
Mass Rangem/z 10–500
Detection Limit< 10 pptv (for common VOCs, 1-s integration)
Response Time< 100 ms
Vacuum SystemMulti-stage differential pumping with turbomolecular pumps
Ion SourceRadiofrequency-guided H₃O⁺ primary ion source
AnalyzerOrthogonal acceleration reflectron TOF mass analyzer
Data Acquisition RateUp to 10 spectra per second
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAliben
OriginSichuan, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic Instrument
ModelPTR-TOF MS 8000
Detection PrincipleProton Transfer Reaction (H₃O⁺-based soft ionization)
Instrument TypeOnline Real-Time Analyzer
ConfigurationIntegrated VOCs Monitoring System
Mass Resolution (m/Δm)≥ 8,000 (FWHM at m/z 100)
Mass Rangem/z 10–500
Detection Limit< 10 pptv (for common VOCs, 1-s integration)
Data Acquisition RateUp to 10 Hz full-spectrum acquisition
Vacuum SystemMulti-stage differential pumping with turbomolecular pumps
Ion SourceRF-driven hollow cathode H₃O⁺ generator
Mass AnalyzerOrthogonal acceleration reflectron TOF
Software PlatformALIBEN Acquire v3.2 with real-time spectral deconvolution and compound identification engine
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAliben
OriginSichuan, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic Instrument
ModelPTR-TOF MS 2500
Detection PrincipleProton Transfer Reaction (H₃O⁺-based soft ionization)
Instrument TypeOnline Real-Time Analyzer
ConfigurationIntegrated VOC Monitoring System
Mass Resolution (m/Δm)≥ 6,000 (FWHM at m/z 100)
Mass Rangem/z 10–300
Detection Limit< 10 pptv (for formaldehyde, 1 s integration)
Data Acquisition RateUp to 10 Hz full-spectrum
Vacuum SystemMulti-stage differential pumping with turbomolecular pumps
Ion SourceRF-driven hollow cathode H₃O⁺ generator
Mass AnalyzerOrthogonal acceleration reflectron TOF
Software PlatformALIBEN Control Suite v4.2 (GLP-compliant audit trail, 21 CFR Part 11 ready)