Empowering Scientific Discovery

Chengdu Ampnovo Biotechnology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
ModelAPN-II
OriginSichuan, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
Wavelength Range185–950 nm
Spectral Bandwidth4 nm
Wavelength Accuracy±0.1 nm
Wavelength Repeatability≤±0.05 nm
DetectorCCD Array
Optical SystemDual-Wavelength Scanning with Hybrid Diffraction Grating
Automation LevelFully Automatic Wavelength Selection & Sample Handling
Sample ThroughputUp to 12 Cuvettes (11 Simultaneous Samples + Reference)
Display10.1-inch Capacitive Touch LCD with VGA/HDMI Output
Computing PlatformEmbedded Industrial PC (Quad-Core CPU, 4 GB RAM, Windows OS)
Data Storage500 GB SSD
ConnectivityDual USB 2.0, RS232, Ethernet, Wi-Fi, VGA, Audio Out
ComplianceDesigned for GLP-compliant food safety laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeManufacturer
Product OriginDomestic (China)
ModelSKJ-IA
PricingUpon Request
Function TypeMulti-analyte Quantitative Detection Platform
Sample ApplicabilityUniversal for Grains, Feed, Fruits, Vegetables, Tea, Dairy Products
Optical Detection Wavelength410 nm
Assay Time per Sample15–30 minutes
Coefficient of Variation (CV)≤0.2%
Detection Channels6 independent optical channels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Region ClassificationDomestic (China)
ModelAPN-R
Detection TargetsLead (Pb), Chromium (Cr), and Multi-analyte Screening in Milk & Dairy Products
Automation LevelSemi-automatic
Throughput60 Samples/Hour
Detection Range (Pb)0–1 ppm (mg/kg)
Detection Range (Cr)0–5 ppm (mg/kg)
Repeatability (CV)<3%
Accuracy>80%
Onboard Storage2 GB
LOD (Pb in raw/pasteurized/UHT milk)0.001 ppm
LOD (Pb in other dairy matrices)0.01 ppm
LOD (Cr)0.1 ppm
Assay Time6 min per test
Reaction Temperature37 °C
CalibrationPre-loaded multi-point standard curves for Pb, Cr, and 12+ additional analytes (e.g., Aflatoxin M1, Chloramphenicol, Melamine)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelSKJ-IA-Z
Instrument CategoryAflatoxin Analyzer
Detection PrincipleImmunochromatographic Colloidal Gold Assay
Display7-inch Capacitive Touchscreen
Test FormatSingle-use, individually packaged lateral flow test strips
Storage ConditionAmbient Temperature
Detection Time≤8 min per assay
LOD1 ppb
Quantitative Range2–150 ppb for AFB₁ and Total Aflatoxins (B₁+B₂+G₁+G₂)
Regulatory AlignmentCompliant with 2015 Edition of Chinese Pharmacopoeia (ChP), Section on Aflatoxin Testing for 19 TCM materials
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeManufacturer
Regional CategoryDomestic (China)
ModelSKJ-IA-III
Function TypeMulti-Analyte (Heavy Metals, Mycotoxins, Pesticides)
Sample CompatibilityUniversal (Grains, Feed, Fruits, Vegetables, Dairy, Tea)
Optical Detection Wavelength410 nm
Assay Time per Sample≤18 minutes
Coefficient of Variation (CV)≤0.2%
Detection Channels6 parallel optical channels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelSKJ-IA
Price RangeUSD 7,000 – 14,000
Function TypeMulti-analyte Quantitative Detection
Sample VersatilityUniversal for Solid & Liquid Food Matrices
Optical Detection Wavelength410 nm
Assay Time per Sample≤25 min
Coefficient of Variation (CV)≤0.2%
Detection Channels6 simultaneous independent channels
Detection Range (Cd & Pb)0–1 ppm
Regulatory AlignmentDesigned to support ISO 17025-compliant workflows and GLP-aligned food safety testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeManufacturer
ModelSKJ-IIA
Price¥80,000
Function TypeMulti-analyte (200+ targets)
Sample ApplicabilityUniversal for food, agricultural, aquatic, livestock, and feed samples
Wavelengths410 nm, 538 nm, 590 nm
Detection Time<15 min per sample
Repeatability≤0.2% CV
Detection Architecture3 independent assay zones, 20-channel parallel optical readout
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelSKJ-IA/03
Price RangeUSD 8,500 – 11,500
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Region of ManufactureDomestic (China)
ModelAPN-C
PriceUSD 8,400 (approx. based on ¥59,800 at 1 USD = ¥7.1)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelNJ-IA
Detection MethodEnzyme Inhibition Assay
Measurement Range0–100% Inhibition Rate
Number of Detection Channels20
Measurement Error< 0.01 Absorbance Units
LOD (Dichlorvos)≤ 0.2 mg/L
Additional LODsParathion ≤ 0.8 mg/L, Chlorpyrifos ≤ 0.16 mg/L, Phoxim ≤ 0.2 mg/L, Methamidophos ≤ 1.2 mg/L, Carbaryl ≤ 0.24 mg/L, Malathion ≤ 1.5 mg/L, Carbofuran ≤ 0.04 mg/L, Methomyl ≤ 0.1 mg/L, Isoprocarb ≤ 0.28 mg/L, Omethoate ≤ 0.44 mg/L, Dichlorvos ≤ 0.1 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelSKJ-IIIA
PriceUSD 11,200 (approx.)
Function TypeMulti-analyte Detection Platform
Sample CompatibilityUniversal for Solid, Liquid, and Semi-solid Food Matrices
Optical Wavelengths410 nm, 538 nm, 630 nm
Detection Time per Assay≤ 30 min
Photometric Repeatability (CV)≤ 1%
Detection Channels10 independent optical channels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelSKJ-IA-05
Function TypeMulti-analyte Quantitative Detection
Sample VersatilityUniversal for Herbal Materials, Decoction Pieces, Animal-derived Herbs
Optical Wavelength410 nm
Detection Time per Sample≤25 minutes
Repeatability (RSD)≤0.2%
Detection Channels6-channel simultaneous measurement
Detection RangeCd 0.1–5 mg/kg, Pb 0.2–10 mg/kg, Cu 2–50 mg/kg
AccuracyCd ≥80%, Pb ≥80%, Cu ≥75%
Compliance ReferenceChinese Pharmacopoeia (2020 Ed., Vol. IV, General Chapter 0412 & 2341)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
ManufacturerANPRO Biotechnology Co., Ltd.
TypeDomestic
ModelAPN-P
PriceUSD 8,300 (approx.)
Detection PrincipleColloidal Gold Immunochromatographic Assay (Quantitative Lateral Flow)
Detection TargetLead (Pb) in Edible Oils
LOD0.02 ppm
Quantitative Range0–1 ppm
DisplayColor Resistive Touchscreen
Data OutputBuilt-in Thermal Printer
Test Card StorageAmbient Temperature (15–30 °C)
Regulatory AlignmentCompliant with GB 2762–2022 (National Food Contaminant Limits), aligned with ISO/IEC 17025 validation practices for rapid screening methods
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelSKJ-IA/01
Instrument CategoryMulti-Mycotoxin Immunoassay Analyzer
Detection PrincipleLateral Flow Immunoassay with Colloidal Gold Quantification
Sample Throughput6 samples per run
Assay Time8–10 min per test
Display7-inch capacitive touchscreen
Integrated Thermal PrinterYes
Data ConnectivityUSB, Wi-Fi, Ethernet
Regulatory ValidationVerified by National Grain Administration Quality Inspection Center (China) for AFB1, DON, ZEN, OTA
StorageAmbient (no refrigeration required for test strips)
Test Strip FormatIndividually sealed single-use cassettes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelSKJ-IA-01
Instrument ClassMulti-Mycotoxin Immunoassay Analyzer
Detection PrincipleColloidal Gold-Based Lateral Flow Immunoassay (Quantitative)
Throughput6 samples per run
Assay Time per Sample≤10 min
Display7-inch capacitive touchscreen
Integrated Thermal PrinterYes
Data ConnectivityWi-Fi / USB / Optional 4G module
Regulatory ValidationOfficial evaluation reports issued by the State Grain Administration (China) for AFB1, DON, ZEN, and OTA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnpro
ModelEV-X
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryAutomated Immunoassay Analyzer for Mycotoxins, Heavy Metals & Pesticide Residues
ComplianceGB 2761–2017, GB 2762–2022, LST 6111–2015 to LST 6114–2015, LST 6144–2023, LST 6145–2023
Throughput≥20 samples/hour (40 test results/hour)
Sample Capacity10 independent reaction channels
Detection PrincipleQuantitative Enzyme-Linked Immunosorbent Assay (ELISA) with photometric readout
Sample TypesCereals, oilseeds, feedstuffs, edible oils, dairy products, traditional Chinese medicinal materials
Key AnalytesAflatoxin B₁, Aflatoxin M₁, Total Aflatoxins, Deoxynivalenol (DON), Zearalenone (ZEN), Fumonisins, Ochratoxin A, T-2 Toxin, Pb, Cd, Cr, Cu, Acetamiprid, Emamectin benzoate, Isoprocarb, Carbaryl, Parathion-methyl, Lambda-cyhalothrin
LOD Range0.01–10 ppb (mycotoxins), 0.01–0.1 ppm (pesticides), 0.02–0.1 ppm (heavy metals)
Liquid Handling Accuracy≤1% CV
Automation ScopeFull unattended workflow — sample loading, extraction, dilution, reagent preheating, cartridge preheating, incubation, optical detection, and data upload
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Regional CategoryDomestic (China)
ModelSKJ-IA/04
Instrument CategoryMulti-Mycotoxin Immunoassay Analyzer
Detection PrincipleLateral Flow Immunoassay with Colloidal Gold-Based Quantitative Signal Readout
Display7-inch Capacitive Touchscreen
Data ConnectivityWi-Fi / USB / Optional Cloud API Integration
Sample ThroughputUp to 6 samples per run
Assay Time≤10 min per test
Storage Condition for Test StripsAmbient (15–30 °C), Individually Sealed
Regulatory ValidationCertified by National Grain Quality Inspection Center (China) per GB/T 28717–2012 and relevant grain safety standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeManufacturer
Regional CategoryDomestic (China)
ModelAPN-I
PriceUSD 1,400 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Region ClassificationDomestic (China)
ModelSKJ-IA-C
PriceUSD 7,000 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelSKJ-IA-04
Price RangeUSD 7,000 – 14,000
FunctionalityMulti-analyte (Cd, Pb, Cu, Cr)
Sample VersatilityUniversal for solid and liquid food matrices
Optical Detection Wavelength410 nm
Assay Time per Sample≤25 minutes
Coefficient of Variation (CV)≤0.2%
Detection Channels6 parallel optical channels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelSKJ-IA/I
PricingUpon Request
Function TypeMulti-analyte Quantitative Detection
Sample ApplicabilityUniversal for Cereals, Feed, Fruits, Vegetables, Tea, Dairy
Wavelength410 nm
Assay Time25 minutes per sample
Coefficient of Variation (CV)≤0.2%
Detection Channels6 independent optical channels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
ModelAPN-M
Detection PrincipleColloidal Gold Immunochromatographic Quantitative Assay
Target AnalyteLead (Pb)
Detection Limit0.02 ppm
Quantitative Range0–1 ppm
Sample TypePreserved mustard greens and other food matrices
DisplayColor resistive touchscreen
Data OutputBuilt-in thermal printer
Reagent StorageAmbient-temperature stable test strips
Regulatory AlignmentCompliant with GB 5009.12–2023 (China National Food Safety Standard for Determination of Lead in Foods), supports GLP-aligned documentation workflows
OriginSichuan, China
ManufacturerANPRO Biotechnology Co., Ltd.
CategoryFood-Specific Heavy Metal Rapid Detector
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelSKJ-IA/02
Instrument CategoryAflatoxin B1 Analyzer
Detection PrincipleImmunochromatographic Colloidal Gold Quantification
Sample Throughput6 samples per run
Detection Time per Sample≤10 min
Display7-inch capacitive touchscreen
Integrated Thermal PrinterYes
Test Strip FormatIndividually packaged lateral flow strips, ambient storage stable
Regulatory ValidationCertified by the National Grain and Oils Quality Inspection Center (China) for AFB1, DON, ZEN, OTA, FB1, and T-2 toxin
Data ConnectivityCloud-ready
Quantitation Range (AFB1)0–150 ppb
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANPRO
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (PRC)
ModelSKJ-IA-03
Price RangeUSD 7,000 – 14,000
Detection PrincipleCompetitive Enzyme-Linked Immunosorbent Assay (ELISA) with Quantitative Lateral Flow Readout
Sample Throughput6 samples per run
Analysis Time≤10 minutes per sample
Target AnalytesCd, Pb, Cu, Hg
Detection RangesCd: 0–1 ppm
Pb0–1 ppm
Cu0–20 ppm
Hg0–0.3 ppm
Sample TypesRaw grains (rice, wheat, corn, barley), milled grain products, animal feed, feed ingredients, botanical herbal materials
DisplayColor resistive touchscreen (≥7″)
Data OutputOnboard thermal printer, GPS-tagged CSV export via Wi-Fi/4G, API-compatible JSON upload to LIMS or cloud platforms
Regulatory AlignmentCompliant with GB 5009.15–2014 (Cd), GB 5009.12–2023 (Pb), and aligned with AOAC Official Method 2019.02 for immunoassay-based heavy metal screening in cereals
Show next