| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer | Yes |
| Type | Bulk Density Tester |
| Design | Portable |
| Sample Form | Dry Solid Powders & Granules |
| Standard Compliance | GB/T 16913–2008 (Natural Pile Method) |
| Funnel Orifice Diameter | 12.7 mm |
| Cylinder Volume | 100 mL |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Cone Angle | 60° |
| Cylinder Material | AISI 304 Stainless Steel |
| Scraper & Plug Rod | AISI 304 Stainless Steel, 25 mm Width |
| Dimensions | ≈ 160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required Balance | 1 kg capacity, 0.02 g readability |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-1206B |
| Price Range | USD 5,600 – 7,000 (est.) |
| Application Field | General-purpose true density analysis |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — correction per technical specs) |
| Sample Type | Solid materials (powders, granules, monoliths, foams, slurries, filters) |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium displacement, based on ideal gas law) |
| Volume Range | 0.01–100 cm³ |
| Temperature Operating Range | 5–35 °C |
| Density Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL (with interchangeable sample cups: 10 mL, 30 mL, 60 mL) |
| Pressure Control | Absolute pressure mode (vacuum-based), 0–130 kPa absolute |
| Test Gas | 99.99% purity N₂ or He (user-supplied) |
| Data Interface | RS232 or USB |
| Software Platform | Windows 7 or later |
| Power Supply | AC 220 V ±10%, 50 Hz, <200 W (vacuum mode) |
| Dimensions | 485 × 350 × 220 mm |
| Weight | 14 kg |
| Compliance | GB/T 24586–2009, ISO 12154:2014 (gas pycnometry), ASTM D5550–22 |
| Brand | Jingxin (Chengdu) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-A303 |
| Instrument Type | Hall Flowmeter & Apparent Density Tester |
| Form Factor | Benchtop (Non-Portable) |
| Sample Type | Free-Flowing Solid Powders |
| Primary Applications | Metal Powders, Additive Manufacturing Feedstocks, Battery Cathode/Anode Materials, Ceramic Precursors, and Industrial Powder QC |
| Standards Compliance | GB/T 1482–2010 (Hall Flow), GB/T 1479.1–2011 (Apparent Density), ASTM B213 (Standard Test Methods for Flow Rate of Metal Powders), ISO 4490:2018 (Metallic powders — Determination of flow rate) |
| Key Dimensions | 230 × 170 × 300 mm (W × D × H) |
| Net Weight | 3.7 kg |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm (interchangeable) |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Funnel Angle | 60° |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel 304, 25 mm width |
| Stopper Rod | Stainless steel 304 |
| Timing Resolution | 0.01 s (external stopwatch required) |
| Recommended Balance | 1000 g capacity, 0.02 g readability (user-supplied) |
| Brand | Jingxin (Chengdu) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-A303 |
| Instrument Type | Bulk Density & Flow Tester |
| Design | Benchtop (Non-Portable) |
| Measurement Principle | Standard Funnel Flow Method (Hall Flowmeter) & Gravimetric Bulk Density Determination |
| Applicable Standards | GB/T 1482–2010, GB/T 1479.1–2011 |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Funnel Cone Angle | 60° |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel 304, 25 mm wide |
| Stopper Rod | Stainless steel 304 |
| Dimensions | 230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Timer Resolution | 0.01 s |
| Required Ancillary Equipment | Analytical balance (max 1000 g, readability 0.02 g) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-A302 |
| Instrument Type | Bulk Density Tester |
| Instrument Class | Portable |
| Measurement Target | Solid Powders & Granules |
| Application Scope | General-purpose bulk density determination of free-flowing and cohesive powders |
| Standard Compliance | GB/T 16913–2008 (Dust Physical Property Testing – Natural Packing Method) |
| Funnel Orifice Diameter | 12.7 mm |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Cone Angle | 60° |
| Cylinder Volume | 100 mL |
| Cylinder & Funnel Material | ASTM A240 Grade 304 Stainless Steel |
| Scraper Blade Width | 25 mm |
| Overall Dimensions | ~160 × 160 × 300 mm |
| Net Weight | 3.7 kg |
| Required External Balance | Capacity ≥ 1000 g, Readability ≤ 0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JZ-10 Series |
| Instrument Type | Tap Density Tester |
| Density Measurement Range | 0–10 g/cm³ |
| Sample Form | Powders & Granules |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Tap Count Range | 1–9999 adjustable |
| Repeatability | ≤ ±1% |
| Operating Voltage | AC 220 V |
| Power Consumption | 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Weight | ~15 kg |
| Test Capacity | ≤500 g per cylinder |
| Cylinder Compatibility | Removable borosilicate glass cylinders (25 mL and 100 mL) |
| Software Output Formats | Word, PDF, Excel |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 <0993> |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JZ-10C |
| Instrument Type | Tap Density Tester |
| Instrument Class | Benchtop (Not Portable — corrected per technical specification: fixed installation, 15 kg, 455×280×125 mm) |
| Sample Form | Powders & Granules |
| Measurement Principle | Mechanical Tapping (Rotational + Vertical Oscillation) |
| Density Range | 0–10 g/cm³ |
| Density Accuracy | ±1% repeatability (per GB/T 5162–2021 & USP <616>) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Tapping Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Tapping Count Range | 1–9999 cycles (user-defined) |
| Sample Vessels | Three removable 25 mL and three 100 mL borosilicate glass cylinders |
| Data Output Formats | PDF, Word, Excel |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 General Chapter 0993, USP <616> |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Brand | Jingxin (Chengdu) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | A302-2 |
| Instrument Type | Bulk Density Tester |
| Instrument Class | Portable |
| Sample Form | Solid Powders & Granules |
| Application Scope | General-purpose bulk density measurement of free-flowing powders |
| Standard Compliance | GB/T 16913–2008 (Natural Pile Method) |
| Funnel Orifice Diameter | 12.7 mm |
| Cylinder Volume | 100 mL |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Cone Angle | 60° |
| Cylinder Material | Stainless Steel 304 |
| Scraper Blade | Stainless Steel, 25 mm wide |
| Plug Rod | Stainless Steel 304 |
| Overall Dimensions | ≈ 160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required External Balance | Capacity ≥ 1000 g, Readability ≤ 0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | JL-A303 |
| Instrument Type | Bulk Density & Flow Rate Tester |
| Form Factor | Benchtop (Portable Design) |
| Sample Type | Free-Flowing Solid Powders |
| Primary Applications | Metal Powders, Additive Manufacturing Feedstocks, Battery Cathode/Anode Materials, Ceramic Precursors, and Advanced Powder Metallurgy |
| Standards Compliance | GB/T 1482–2010 (Hall Flow Test), GB/T 1479.1–2011 (Apparent Density by Funnel Method) |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Funnel Included Angle | 60° |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel, 25 mm width |
| Stopper Rod | Stainless steel 304 |
| Dimensions | Approx. 230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Timing Resolution | 0.01 s (external stopwatch required) |
| Recommended Balance | 1 kg capacity, 0.02 g readability (user-supplied) |
| Brand | Chengdu JinXin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Bulk Density & Flow Tester |
| Design | Portable Benchtop Unit |
| Measurement Principle | Standard Funnel Flow (Hall Flowmeter) & Gravimetric Bulk Density |
| Applicable Standards | GB/T 1482–2010, GB/T 1479.1–2011 |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Funnel Angle | 60° |
| Cylinder Volume | 25 mL (stainless steel 304) |
| 刮刀 (Steel Ruler) | 25 mm wide, stainless steel 304 |
| Stopper Rod | Stainless steel 304 |
| Dimensions | ≈ 230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Required Ancillaries | Analytical balance (max 1 kg, d = 0.02 g), stopwatch (0.01 s resolution) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JZ-7 |
| Price Range | USD 920–1,120 (FOB) |
| Application Field | General-purpose density testing |
| Instrument Type | Bulk Density Tester |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Solid Powders |
| Measurement Scope | Tap Density & Bulk Density |
| Repeatability | ≤ ±1% |
| Vibration Amplitude | 3.0 mm ± 0.2 mm |
| Accuracy Error | ≤ ±1% |
| Number of Stations | 2 Active + 2 Waiting Positions |
| Sample Mass Capacity | ≤ 500.00 g |
| Vibration Frequency Options | 100, 200, 250, or 300 taps/min (adjustable via rotary selector) |
| Tap Count Range | 1–9999 (user-programmable) |
| Standard Compliance | GB/T 5162–2021 |
| Dimensions (W×D×H) | 450 × 280 × 180 mm |
| Net Weight | ~13 kg |
| Power Supply | AC 220 V, 50/60 Hz, 110 W |
| Included Cylinders | 25 mL, 50 mL, and 100 mL (ISO/USP-compliant borosilicate glass) |
| Data Output | PDF, Word, Excel export via proprietary software with audit trail logging |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China-made) |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — corrected per technical specification: 14 kg, fixed installation) |
| Sample Type | Solids (powders, granules, bulk solids, foams, filter media, slurries) |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium Displacement, ASTM D5550 / ISO 12154 compliant) |
| Density Range | 0.01–100 g/cm³ |
| Temperature Control Range | 15–39 °C |
| Repeatability | ±0.02% RSD |
| Resolution | 0.00001 g/cm³ |
| Sample Volume Capacity | 0.01–100 cm³ (with interchangeable sample chambers: 10 mL, 30 mL, 60 mL, and fixed 100 mL reference chamber) |
| Test Duration | ~3 min per analysis (fully automated) |
| Pressure Mode | Absolute pressure vacuum system (0–130 kPa absolute), integrated vacuum pump |
| Calibration Standard | Certified stainless steel sphere (included) |
| Software Interface | Windows 7 or later, RS232/USB |
| Compliance | GB/T 24586–2009, ASTM D5550–22, ISO 12154:2014, USP <699> (for density determination in pharmaceutical excipients) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer | Yes |
| Type | Bulk Density Tester |
| Model | JL-A302 |
| Design | Portable Benchtop Unit |
| Measurement Principle | Free-Fall Natural Packing Method per GB/T 16913-2008 |
| Funnel Orifice Diameter | 12.7 mm |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Angle | 60° |
| Cylinder Volume | 100 mL (AISI 304 Stainless Steel) |
| Scraper Blade | AISI 304, 25 mm wide |
| Stopper Rod | AISI 304 Stainless Steel |
| Overall Dimensions | ~160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required External Balance | Capacity ≥1000 g, Readability ≤0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Bulk Density Tester |
| Design | Portable Benchtop Unit |
| Sample Form | Dry Solid Powders and Granules |
| Compliance Standard | GB/T 16913–2008 (Natural Pile Method) |
| Funnel Orifice Diameter | 12.7 mm |
| Cylinder Volume | 100 mL |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Cone Angle | 60° |
| Cylinder Material | AISI 304 Stainless Steel |
| Scraper & Plug Rod | AISI 304 Stainless Steel |
| Dimensions | ≈ 160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required External Balance | Capacity ≥ 1000 g, Readability ≤ 0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | JZ-10 |
| Instrument Category | Tap Density Tester |
| Form Factor | Benchtop (Not Portable — corrected per ISO/USP design standard) |
| Sample Type | Dry Powders & Granules |
| Density Measurement Range | 0–10 g/cm³ |
| Density Accuracy | ±1% repeatability (per GB/T 5162–2021 & USP <616>) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Modes | Vertical oscillation + synchronized 360° rotational motion |
| Vibration Frequency Options | 100 / 200 / 250 / 300 cycles/min |
| Programmable Taps | 1–9999 taps per cycle |
| Test Vessels | Removable borosilicate glass cylinders (25 mL and 100 mL, quantity varies by submodel: JZ-10A/B/C) |
| Power Supply | AC 220 V, 50 Hz, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 <0993>, USP <616> |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | JZ-10C |
| Price Range | USD 920–1,120 (FOB) |
| Application Field | General-purpose density tester |
| Instrument Type | Tap density tester |
| Instrument Form Factor | Benchtop (not portable — corrected per ISO/USP design norms) |
| Measurement Type | Solid powder/granule density |
| Density Range | 0–10 g/cm³ |
| Primary Function | Tap density and bulk density determination of powders and granules |
| Density Accuracy | ±1% repeatability (per GB/T 5162–2021 & USP <616>) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Modes | Vertical oscillation + synchronized 360° rotational motion |
| Vibration Cycles | 1–9999 (user-programmable) |
| Vibration Frequencies | 100, 200, 250, or 300 taps/min (4-step selector switch) |
| Sample Vessels | Three removable calibrated glass cylinders (25 mL and 100 mL ×3 each) |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Power Supply | AC 220 V, 50/60 Hz, 110 W |
| Compliance | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 <0993>, USP <616> |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JZ-10-C |
| Instrument Type | Tap Density Tester |
| Category | Portable Solid Density Analyzer |
| Measurement Range | 0–10 g/cm³ |
| Primary Application | Tap density and bulk density measurement of powders and granular solids |
| Repeatability Error | ≤ ±1% |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Adjustable Tapping Cycles | 1–9999 |
| Selectable Vibration Frequencies | 100 / 200 / 250 / 300 taps/min |
| Dual Motion Mechanism | Vertical tapping + horizontal rotation |
| Sample Container Options | Three 25 mL and three 100 mL borosilicate glass cylinders (removable) |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Weight | ~15 kg |
| Software Output Formats | Word, PDF, Excel |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, Chinese Pharmacopoeia 2020 Edition <993>, USP <616> |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JZ-10B |
| Instrument Category | Tap Density Tester |
| Density Measurement Range | 0–10 g/cm³ |
| Measurement Accuracy | ±1% repeatability (per GB/T 5162–2021) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Programmable Taps | 1–9999 cycles |
| Sample Capacity | ≤500 g (per cylinder) |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Cylinder Configuration | Two stations, each with one 25 mL and one 100 mL borosilicate glass cylinder |
| Compliance | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 General Chapter 0993 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JZ-1 |
| Instrument Type | Tapped Density Analyzer |
| Application | Tapped density measurement of metal powders and battery materials |
| Compliance | GB/T 5162–2021, YS/T 677–2008 |
| Vibration Amplitude | 50 mm ± 0.2 mm |
| Vibration Frequency | 60 taps/min |
| Tap Count Range | 1–9999 (user-configurable) |
| Sample Positions | 3 independent stations |
| Standard Cylinders | 3 × stainless steel cylinders (ID 16.25 mm, height 80 mm, volume 16.6 mL) |
| Measurement Accuracy | ±1.5% |
| Power Supply | AC 220 V ± 22 V, 150 W |
| Dimensions | 400 × 280 × 270 mm |
| Weight | ~13 kg |
| Construction | 304 stainless steel frame and components |
| Software | Included PC-based data acquisition and reporting software (tapped density calculation, report generation, CSV export) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JZ-10A |
| Price Range | USD 920–1,120 (FOB) |
| Application Field | General-purpose powder density testing |
| Instrument Type | Tap density tester |
| Form Factor | Benchtop (not portable |
| Sample Type | Solid powders and granules |
| Density Measurement Range | 0–10 g/cm³ |
| Primary Function | Tap density and bulk density determination of free-flowing and cohesive powders |
| Repeatability | ≤ ±1% |
| Stroke Amplitude | 3.0 ± 0.2 mm |
| Tap Count Range | 1–9999 cycles (user-programmable) |
| Tap Frequency Options | 100, 200, 250, or 300 taps/min |
| Standard Vessel | Two 100 mL borosilicate glass cylinders |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Weight | ~15 kg |
| Power Supply | AC 220 V, 50/60 Hz, 110 W |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Category | Domestic (China) |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — corrected per technical specification: 14 kg, fixed installation required) |
| Sample Type | Solid powders, granules, bulk solids, foams, slurries, and filtration media |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium Displacement, ISO 12154:2014 compliant) |
| Volume Range | 0.01–100 cm³ |
| Temperature Range | 5–35 °C |
| Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL |
| Optional Sample Cups | 10 mL, 30 mL, 60 mL |
| Pressure Control | Absolute pressure mode (0–130 kPa), vacuum-assisted degassing |
| Test Gas | 99.99% N₂ or He (user-supplied) |
| Software Interface | Windows 7 or later |
| Communication | RS-232 or USB |
| Power | AC 220 V ±22 V, 50 Hz |
| Dimensions | 485 × 350 × 220 mm (L×W×H) |
| Weight | 14 kg |
| Compliance | GB/T 24586–2009, ISO 12154:2014, ASTM D5550–22 |
| Key | Brand: Chengdu Jingxin (CDJX) |
|---|---|
| Model | JZ-7, JZ-10A / JZ-10B / JZ-10C |
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Tap Density Tester |
| Instrument Category | Benchtop Laboratory Densimeter |
| Sample Form | Solid Powders |
| Primary Measurement | Tap Density & Bulk Density |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Tapping Count Range | 0–9999 cycles (user-programmable) |
| Repeatability | ≤ ±1% RSD |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Weight | ~15 kg |
| Compliance | GB/T 5162–2021, USP <616> |
| Software | Integrated tap density calculation module with PDF/Excel export capability |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JZ-10B |
| Instrument Type | Tap Density Tester |
| Instrument Class | Benchtop (Not Portable — corrected per ISO 14857 & USP <616>) |
| Measurement Type | Solid Powder Bulk & Tap Density |
| Density Range | 0–10 g/cm³ |
| Density Accuracy | ±1% RSD (per GB/T 5162–2021 & USP <616>) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Modes | Vertical oscillation + synchronized 360° rotational motion |
| Adjustable Tap Counts | 1–9999 cycles |
| Selectable Tap Frequencies | 100, 200, 250, or 300 taps/min |
| Test Stations | Dual independent stations |
| Standard Vials | Two 25 mL and two 100 mL borosilicate glass graduated cylinders |
| Repeatability | ≤ ±1% (n = 10, certified reference powder) |
| Power Supply | AC 220 V, 50 Hz, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Compliance | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 General Chapter 0993, USP <616> |
| Brand | CDJX |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JZ-10C |
| Instrument Type | Tap Density Tester |
| Density Measurement Range | 0–10 g/cm³ |
| Measurement Accuracy | ±1% RSD (Repeatability) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Programmable Tap Count | 1–9999 |
| Sample Capacity | ≤500 g (per 250 mL cylinder) |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Software Output Formats | PDF, Word, Excel |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 <0993>, USP <616> |