Chip System/Accessories
Filter
Showing 31–46 of 46 results
| Brand | Microdrop |
|---|---|
| Origin | Germany |
| Model | Autodrop Gantry ECO |
| Spotting Type | Non-contact piezoelectric inkjet |
| Minimum Spot Size | <5 µm |
| Spotting Throughput | 2000 spots/sec |
| Substrate Capacity | Up to 384-well microplates or standard microscope slides |
| Repeatability & Positioning Accuracy | ±5 µm |
| Compatible Fluid Viscosity Range | 20–10,000 mPa·s (heated operation supported) |
| Drive Technology | Piezoelectric actuation with inert fluidic path (glass/PTFE/PEEK) |
| System Architecture | Modular gantry-based platform with integrated liquid handling and real-time motion compensation |
| Brand | Microfluidic ChipShop (MCS) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Sample Preparation Chip |
| Instrument Type | Microfluidic Chip System |
| Membrane Configuration | Crossflow Filtration Architecture |
| Interface Standard | Luer & Mini-Luer |
| Compatible Sample Volume Range | 25–100 µL Whole Blood |
| Plasma/Serum Yield | 12–35 µL per chip unit |
| Membrane Diameter Options | 10 mm (Fluidic 168/200/1113), Dual-Geometry (Fluidic 783), On-Chip Detection-Optimized (Fluidic 973), Open-Access (Fluidic 234/235), Transwell-Compatible (Fluidic 219) |
| Customization | Membrane Material & Pore Size Available on Request |
| Brand | Microfluidic ChipShop (MCS) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Straight-Channel Chip |
| Instrument Category | Microfluidic Chip System |
| Form Factor | Microscope Slide Format (75.5 × 25.5 × 1.5 mm) & SBS-Compatible Microtiter Plate Format (85.48 × 127.76 mm) |
| Channel Configurations | 4–96 parallel straight channels |
| Interface Options | Through-Hole, Mini Luer, Luer, Olive |
| Channel Dimensions | Widths from 100 µm to 2 mm |
| Material Options | Polycarbonate (PC), Polystyrene (PS), Polymethylmethacrylate (PMMA), Cyclic Olefin Polymer (COP/Zeonor) |
| Surface Functionalization Compatibility | DNA probe spotting, poly-L-lysine, collagen coating, etc. |
| Compliance | Designed for ISO 8601-compliant lab automation workflows |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Model | Mitos Dropix |
| Type | Microfluidic Droplet Coalescence Platform |
| Application Domain | Life Sciences, Synthetic Biology, High-Throughput Screening |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Model | Mitos Dropix |
| Type | Microfluidic Droplet Coalescence Platform |
| Application Domain | Life Sciences, Synthetic Biology, High-Throughput Screening |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GenePix 4000B |
| Instrument Type | Microarray Scanning System |
| Laser Configuration | Dual-laser (635 nm & 532 nm), Simultaneous Excitation and Detection |
| Resolution Range | 5–100 µm adjustable |
| Scan Speed | ~6.5 min per slide at 10 µm resolution (dual-channel) |
| Optical Path | Non-confocal epifluorescence |
| PMT Auto-balancing | Yes, real-time channel normalization |
| Focus Adjustment | Motorized Z-axis with manual override |
| Laser Power Control | Digitally tunable per channel |
| Calibration | Built-in NIST-traceable performance verification protocol |
| Software Integration | Native compatibility with GenePix Pro 7.x and Acuity 5.x |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Microfluidic Chip System |
| Model | MPI-M |
| Pricing | Upon Request |
| Key Specifications | Dynamic Range > 5 decades |
| Emission Wavelength Detection Range | 300–650 nm |
| Photometric Sensitivity | SP > 1000 A/lm |
| High-Voltage Power Supply | 4-channel, 0–2000 V per channel, 0–2 mA per channel, 10-step programmable sequencing, selectable output modes (output / disconnect / ground), current-limiting protection |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MPI-P |
| Instrument Category | Microfluidic Chip System |
| Electrochemical Analyzer Specifications | Potential Range: ±10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | 10¹² Ω |
| Sensitivity | 1×10⁻¹² A to 0.1 A (16 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 1×10⁻⁴ to 200 V/s |
| Supported Techniques | Cyclic Voltammetry (CV), Linear Sweep Voltammetry (LSV), Chronoamperometry (CA), Chronocoulometry (CC), Bulk Electrolysis (BE), Open Circuit Potential vs. Time (OCPT) |
| High-Voltage Power Supply | 4 Channels, 0–2000 V per channel, 0–2 mA per channel, Programmable Output Mode (Output/Disconnect/Ground), Current-Limit Protection (0–2 mA), 10-Step Program Sequence |
| Brand | Okmetic |
|---|---|
| Origin | Finland |
| Wafer Type | SOI (Silicon-on-Insulator) |
| Substrate Material | Single-Crystal Silicon |
| Structural Configuration | Handle Layer / Buried Oxide (BOX) / Device Layer |
| Available Formats | Prime, Double-Side Polished (DSP), Patterned Device Layer Options |
| Process Compatibility | MEMS, Deep Reactive Ion Etching (DRIE), Anodic Bonding, Wafer-Level Sealing |
| Resistivity Range | 0.001–10,000 Ω·cm |
| Device Layer Thickness | 1–50 µm (customizable) |
| BOX Thickness | 0.1–4 µm (customizable) |
| Diameter Options | 100 mm, 150 mm, 200 mm |
| Surface Roughness (Ra) | <0.2 nm (prime/DSP) |
| Brand | Randox Toxicology |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MultiSTAT |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SI500 ICP-RIE Plasma Etching System |
| Price Range | USD 68,000 – 136,000 (FOB Hamburg) |
| Temperature Control Range | −120 °C to +150 °C |
| Plasma Source | Inductively Coupled Plasma (ICP) with Separate Bias RF (13.56 MHz) |
| Etch Chemistry Compatibility | Fluorine-based (SF₆, CF₄, CHF₃), Chlorine-based (Cl₂, BCl₃), Oxygen, Argon, and mixed gas chemistries |
| Chamber Material | Anodized aluminum with quartz or ceramic liner options |
| Maximum Wafer Size | 200 mm (8-inch) |
| Vacuum System | Turbo-molecular pump with backing pump (base pressure <5×10⁻⁷ mbar) |
| Process Control | Fully computerized via SENTECH EtchControl™ v4.x with recipe management, real-time parameter logging, and audit trail support |
| Brand | UNITMA |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Quick-ray UT-06 |
| Spotting Method | Contact-based Manual Punching |
| Array Density | 1–300 cores per recipient block |
| Core Volume Capacity | 1–300 tissue cores |
| Spotting Time | 1–3 seconds per core |
| Slide/Plate Capacity | 120 / 90 / 60 / 30 / 20 positions (adjustable cassette trays) |
| Repeatability Accuracy | ±1 mm |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | URE-2000 Series |
| Price Range | USD 42,000 – 70,000 |
| Scanning Throughput | 2 µm feature resolution |
| Resolution | 0.8 µm (with 2 µm positive photoresist) |
| Detection System Type | UV Optical Detection |
| Excitation Wavelength | 365 nm (i-line) |
| Emission Wavelength | 365 nm |
| Exposure Area | Up to 200 mm × 200 mm (URE-2000/A8) |
| Exposure Time Range | 0.1 s – 9999.9 s (programmable timer) |
| Mercury Lamp Power | 1000 W (DC, Osram Ultra-High-Pressure Hg Lamp) |
| Illumination Uniformity | ≤2.5% (Ø100 mm), ≤5% (Ø200 mm) |
| Alignment Accuracy | ±0.8 µm (single-side), ±2 µm (double-side, 0.8 mm wafer thickness) |
| Maximum Resist Thickness | 500 µm (SU-8, user-provided conditions) |
| Brand | Bo-Semitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JX-8B |
| Price | USD 42,000 (FOB) |
| Brand | AZENTA (formerly Anserad) |
|---|---|
| Origin | United Kingdom |
| Device Type | Handheld 2D/1D Barcode Reader for Sample Tube Tracking |
| Dimensions | 155 × 65 × 38 mm (L×W×D) |
| Weight | 150 g |
| Power Input (Charger) | 100–240 VAC, 50/60 Hz, 260 mA |
| Output (Charger) | 5 VDC, 2.4 A |
| Battery Life | Up to 8 hours per charge |
| Onboard Storage Capacity | Up to 60,000 barcode records |
| Communication | USB-Cable or Bluetooth v4.2+ |
| Operating Temperature Range (with optional Cryo-Protection Module) | −20 °C to +40 °C |
| Compliance | CE, RoHS, FCC Class B |
| Brand | AZENTA (formerly Ziath) |
|---|---|
| Origin | Germany |
| Model | Mirage Connect |
| Dimensions | 208 × 135 × 80 mm |
| Weight | 1.35 kg |
| Power Input | 100–240 VAC, USB-C powered |
| Power Consumption | ≤10 W |
| Camera | 16 MP autofocus imaging system |
| Decoding Time | <2 seconds per plate |
| Compatible Formats | ISO/IEC 16022 DataMatrix (2D), optional barcode module for 1D symbologies |
| Supported Storage Formats | 24-, 48-, 96-, 138HD-, 240-, and 384-well cryoboxes |
| Operating Temperature | 5–35 °C |
| Compliance | GxP, FDA 21 CFR Part 11 (with DP5 software audit trail), IVDR, ISO 20387 (Biobanking) |
| Connectivity | Dual-mode RJ45 Ethernet (HTTP/HTTPS REST API) and USB-C interface |
| Software Platform | DP5 v5.x with LIMS integration, mobile app control, and centralized fleet management via LAN/WAN |
| Warranty | 2 years |