Chromatographic Detector
Filter
Showing 1–30 of 99 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 201/525 |
| Instrument Type | Ultraviolet-Visible (UV-Vis) Detector |
| Noise | < ±1.0 × 10⁻⁵ AU @ 254 nm |
| Wavelength Range | 190–800 nm |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Precision | ±1.0 nm |
| Optical Design | Single-Wavelength (201) / Dual-Wavelength (525) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 502 |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation/Emission Wavelengths | Dual-Programmable |
| Spectral Range | Broad (Typical UV-Vis, e.g., 200–700 nm) |
| Bandwidth Options | Multiple Fixed and Variable Slit Widths |
| Sensitivity | High (Sub-picomolar Detection Limit for Standard Fluorophores) |
| Noise Level | Ultra-Low (RMS < 0.5 mV at 1 s time constant) |
| Scan Mode | Point-Scan Fluorescence Acquisition |
| Spectral Storage Capacity | ≥64 Predefined Method-Linked Spectral Profiles |
| Dynamic Range | >4 Orders of Magnitude (Linear Response from 10⁻¹² to 10⁻⁸ M for quinine sulfate equivalent) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 6000 |
| Instrument Type | Ultraviolet-Visible (UV-Vis) Diode Array Detector |
| Detection Limit | 0.1 µg/L (typical, based on caffeine in methanol/water, 254 nm) |
| Precision | ≤0.2% RSD (retention time and peak area, n=6) |
| Flow Rate Compatibility | 1 µL/min to 20 mL/min |
| Optical Path Length | 50 mm LightPipe flow cell (patented) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Instrument Type | Refractive Index Detector (RID) |
| Flow Rate Range | 1–50 mL/min |
| Flow Cell Volume | 7 µL |
| Temperature Control Range | 35–55 °C (adjustable in 1 °C increments |
| Flow Cell Pressure Rating | 6 kg/cm² |
| Internal Cell Dead Volume | 88 µL or 353 µL (selectable) |
| Linear Range | 0–2000 µRIU |
| Noise Level | ≤10 × 10⁻⁸ RIU |
| Drift (Full-Scale) | <1 mV/hour with 1 mL/min H₂O flow |
| Auto-Zero Function | Yes |
| Integrated Flush Valve | Yes |
| Digital Interface | RS-232 (bidirectional parameter transmission) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Diode Array Detector WR |
| Instrument Type | Diode Array Detector (DAD) |
| Wavelength Range | 190–950 nm |
| Short-Term Noise | < ±7 µAU (ASTM compliant) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III ELSD |
| Detection Principle | Evaporative Light Scattering Detection |
| Compatible Systems | Agilent 1260 Infinity III LC, Other HPLC/UHPLC Platforms via Analog/Digital I/O |
| Operating Temperature Range | Up to 120 °C |
| Carrier Gas | Nitrogen or Compressed Air |
| Detection Sensitivity | Sub-nanogram (ng) Level for Non-Volatile and Semi-Volatile Analytes |
| Baseline Stability | Minimal Drift (<0.5 mV/h after equilibration) |
| Data Acquisition Rate | Up to 100 Hz |
| Reproducibility | RSD < 2% (n = 6, repeated injections) |
| Solvent Compatibility | Fully compatible with DMSO, THF, DMF, chlorinated solvents, and high-boiling-point mobile phases |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity III FLD |
| Detection Principle | Dual-wavelength Programmable Fluorescence Detection |
| Compatible Systems | Agilent InfinityLab LC Systems & Third-party HPLC Platforms |
| Detection Limit | Raman S/N > 3000 (measured against dark signal noise reference) |
| Data Acquisition Rate | Up to 74 Hz |
| Detector Type | Fluorescence Detector (FD) |
| Flow Cell Interface | Cartridge-style flow cell with auto-identification |
| Regulatory Compliance Support | GLP-compliant parameter logging, audit-ready metadata capture |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Fluorescence Detector with Full-Spectrum Acquisition |
| Instrument Type | Fluorescence Detector (FD) |
| Detection Limit | Raman Signal-to-Noise Ratio > 3000 (measured against dark signal noise reference) |
| Data Acquisition Rate | Up to 148 Hz |
| Compatibility | Fully compatible with Agilent InfinityLab LC systems and third-party HPLC platforms |
| Flow Cell | Bio-inert, optimized for biomolecular applications |
| Light Source | Long-life pulsed xenon lamp (> 4000 h), integrated lamp reference system |
| Optical Design | Simplified optical path for superior baseline stability |
| Spectral Capability | Real-time full-spectrum acquisition synchronized with chromatographic elution |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III High-Sensitivity Diode Array Detector (HS) |
| Detection Principle | UV-Vis Absorption Spectrophotometry via Fixed-Slit DAD Architecture |
| Noise Level | < ±3 µAU (typical baseline noise, 1 s bandwidth, 254 nm, 10 mm pathlength cell) |
| Signal Channels | Up to 8 simultaneous wavelength-specific absorbance signals |
| Data Acquisition Rate | Up to 120 Hz (full-spectrum acquisition) |
| Flow Cell | Agilent Max-Light Cartridge Flow Cell with Optical Waveguide, 10 mm pathlength (standard), 60 mm pathlength option available (< ±0.6 µAU/cm noise) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Multi-Wavelength Detector |
| Compatible System | HPLC |
| Detector Type | Diode Array Detector (DAD) |
| Wavelength Range | 190–950 nm |
| Short-Term Noise | < ±7 µAU (ASTM E1657-05) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1260 Infinity III RID |
| Detection Principle | Differential Refractometry |
| Compatible Systems | Agilent 1200/1260/1290 Series HPLC & UHPLC Platforms |
| Detection Mode | Dual-Flow, Solvent-Compensated RI |
| Data Acquisition Rate | 74 Hz |
| Baseline Noise | < 2.5 nRIU (typical, 1 sec time constant) |
| Temperature Control | Electronic Thermal Control (ETC), 5–55 °C, ±0.01 °C stability |
| Flow Cell Volume | 8 µL |
| Lamp Type | Tungsten-Halogen, Lifetime > 2000 h |
| Auto-Compensation | Dynamic light intensity adjustment for lamp aging and flow cell fouling |
| Maintenance Access | Front-panel serviceable fluidic path and valves |
| EMF Monitoring | Real-time tracking of purge duration, lamp operating hours, and system diagnostics |
| Software Integration | Fully compatible with OpenLab CDS (ChemStation Edition), compliant with FDA 21 CFR Part 11 audit trail requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Variable Wavelength Detector |
| Compatible System | High-Performance Liquid Chromatography (HPLC) |
| Detector Type | UV-Vis Absorbance Detector |
| Data Acquisition Rate | Up to 120 Hz |
| Dual-Wavelength Mode | Yes |
| Baseline Noise | < ±0.25 × 10⁻⁵ AU |
| Drift | < 0.5 × 10⁻⁴ AU/h |
| Linear Range | > 2.5 AU |
| Wavelength Accuracy | ±1 nm (verified via built-in holmium oxide filter) |
| Temperature Control | Electronic Temperature Control (ETC) with active stabilization |
| Flow Cell Options | 8 interchangeable analytical and preparative flow cells (including 10 mm, 60 mm pathlengths |
| RFID Integration | Yes (for cell/lamp identification and usage traceability) |
| EMF Support | Yes (lamp hours, maintenance alerts, user-defined thresholds) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Diode Array Detector |
| Instrument Type | Diode Array Detector (DAD) |
| Noise Level | < ±3 µAU (10 mm flow cell, 1 s response time) |
| Signal Channels | Up to 8 simultaneous wavelength channels |
| Spectral Acquisition Rate | Up to 240 Hz |
| Optical Path Length Options | 10 mm (standard), 60 mm (high-sensitivity flow cell) |
| Baseline Drift | < ±0.6 µAU/cm (60 mm flow cell) |
| Linear Dynamic Range | Up to 2.5 AU (standard) |
| Slit Width Programmability | 1–8 nm |
| Temperature Control | Electronic Temperature Control (ETC) with RFID-tracked flow cell and lamp modules |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1290 Infinity III Diode Array Detector FS |
| Detection Principle | UV-Vis Absorbance Spectroscopy via Photodiode Array |
| Instrument Type | Diode Array Detector (DAD) |
| Noise Level | ±0.6 µAU/cm (with 60 mm pathlength flow cell) |
| Signal Channels | Up to 8 simultaneous wavelength-specific signals |
| Sampling Rate | Up to 240 Hz |
| Flow Cell Options | MaxLight™ cartridge flow cells (10 mm and 60 mm pathlengths) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1290 Infinity III ELSD |
| Detection Principle | Evaporative Light Scattering Detection |
| Compatibility | Integrated with Agilent 1290 Infinity III LC Systems and Third-Party HPLC Platforms |
| Sensitivity | Sub-nanogram detection capability for non-UV-absorbing analytes |
| Temperature Control Range | Peltier-cooled evaporator, 10–80 °C |
| Dynamic Range | Four decades (10⁴) |
| Reproducibility | RSD < 2% (n ≥ 6 injections, standard test conditions) |
| Response Time | < 0.1 s |
| Data Acquisition Rate | Up to 100 Hz |
| Gas Flow Control | Programmable, real-time nitrogen or air flow (0–3.0 L/min) |
| Solvent Compatibility | Fully compatible with gradient elution using volatile and semi-volatile mobile phases including acetonitrile, methanol, THF, and aqueous buffers — DMSO-free operation enabled |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1290 Infinity III RID |
| Instrument Type | Refractive Index Detector (RID) |
| Compatible System | Ultra-High Performance Liquid Chromatography (UHPLC) |
| Flow Cell Design | Ultra-Low Dispersion Micro-Flow Cell |
| Data Acquisition Rate | 148 Hz |
| Detection Principle | Differential Refractometry |
| Compliance | Designed for GLP/GMP environments with support for FDA 21 CFR Part 11–compliant software workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1290 Infinity III Variable Wavelength Detector |
| Compatible System | High-Performance Liquid Chromatography (HPLC) and Ultra-High-Performance Liquid Chromatography (UHPLC) |
| Detector Type | UV-Vis Absorbance Detector |
| Data Acquisition Rate | Up to 240 Hz |
| Baseline Noise | < ±0.25 × 10⁻⁵ AU |
| Drift | < 0.5 × 10⁻⁴ AU/h |
| Linear Dynamic Range | > 2.5 AU |
| Wavelength Range | 190–950 nm |
| Wavelength Accuracy | ±0.1 nm (verified via built-in holmium oxide filter) |
| Temperature Control | Electronic Temperature Control (ETC) with ±0.05 °C stability |
| Flow Cell Identification | RFID-enabled stainless steel or fused silica flow cells |
| Lamp Life Monitoring | Real-time EMF tracking with user-defined thresholds |
| Software Integration | Fully compatible with OpenLab CDS, MassHunter, and compliant with FDA 21 CFR Part 11 audit trail requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Wide Dynamic Range DAD |
| Instrument Type | Diode Array Detector (DAD) |
| Compatible System | Agilent InfinityLab LC Systems |
| Data Acquisition Rate | Up to 120 Hz (DAD FS variant) |
| Linear UV Dynamic Range Extension | 30× vs. conventional DAD |
| Temperature Control | Second-Generation Electronic Temperature Control (ETC) |
| Cell & Lamp Identification | RFID-enabled for audit-trail compliance |
| Flow Cell Pathlengths | Dual-path, optimized for high- and low-concentration analytes |
| Regulatory Support | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | 8255 NCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Selective Nitrogen-Specific Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 8355 SCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Elemental-Specific Chromatographic Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Flame Ionization Detector |
| Compatible Instruments | Agilent Intuvo 9000, 8890, 8860, and 7890 Series Gas Chromatographs |
| Detection Limit (n-tridecane) | ≤1.2 pg C/s (8890 GC), ≤1.4 pg C/s (Intuvo 9000 & 7890B GC), ≤3 pg C/s (8860 GC) |
| Linear Dynamic Range | >10⁷ (±10%) |
| Data Acquisition Rate | Up to 1000 Hz (Intuvo 9000 & 8890 GC) |
| Maximum Operating Temperature | 450 °C (8890/7890B/Intuvo 9000), 425 °C (8860) |
| Column Compatibility | Capillary-optimized or universal (capillary & packed column) variants available |
| Mounting Flexibility | Optional third-detector position on 8890 GC left side |
| Ignition Control | Auto-ignition and flame-out detection with recovery |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | micro-ECD |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Electron Capture Detector (ECD) |
| Detection Principle | Radioisotope-based electron capture |
| Minimum Detectable Level (MDL) for Lindane | 3.8 fg/mL |
| Linear Dynamic Range | 5 × 10⁴ (fg/mL to ng/mL) |
| Sampling Rate | 5–500 Hz |
| Compliance | U.S. EPA Contract Laboratory Program (CLP) Method 8081B/8270 for pesticide analysis |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Agilent Technologies (Shanghai) Co., Ltd. |
| Type | Nitrogen-Phosphorus Detector (NPD) |
| Compatible Instrument | Gas Chromatograph (GC) |
| Bead Material | High-Performance Glass-Based Blos Rubidium Bead |
| Lifetime | ≥2× that of conventional ceramic rubidium beads |
| N-Compound Sensitivity | Comparable to ceramic beads |
| P-Compound Sensitivity | Enhanced vs. ceramic beads |
| Environmental Tolerance | High resistance to ambient humidity and moisture exposure |
| Regulatory Compliance | Designed for use in GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TCD for GC Systems |
| Compatible Instruments | Agilent Intuvo 9000, 8890, 8860, and 7890 Gas Chromatographs |
| Detector Type | Universal Thermal Conductivity Detector |
| Baseline Drift | Ultra-low drift enabled by proprietary fluid-switching architecture with rapid post-startup stabilization |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE Elite |
| Detector Type | Electrochemical Detector (ECD) |
| Compatible Systems | HPLC, UHPLC, EC-MS Coupling |
| Operating Modes | DC, Pulsed, Scanning |
| Signal Processing | Advanced Digital Filter (ADF) |
| Flow Cell Volume Range | 0–300 nL (continuously adjustable) |
| Cell Design | Central Jet-Wall Electrode Configuration |
| Temperature Control | Integrated Faraday-Shielded Thermostatic Chamber |
| Compliance | Designed for GLP/GMP environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DECADE II |
| Pricing | Upon Request |
| Detector Type | Electrochemical Detector (ED) |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE II |
| Detector Type | Electrochemical Detector (ECD) |
| Operating Modes | DC, Pulse, and Scan |
| Digital Filter Range | 0.5–0.001 Hz (1–2–5 decade steps) |
| Potential Range | ±2.00 V |
| Faraday Column Oven Dimensions | H 37 cm |
| Temperature Range | Ambient +7 °C to 45 °C |
| Temp. Stability | ±0.1 °C |
| Flow Cell Types | Central Jet Wall-Flow Cell & Conventional Thin-Layer Cell |
| Electrode Configurations | SCC, DCC, TCC, QCC |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE II SDC |
| Detector Type | Electrochemical Detector (ECD) |
| Operating Modes | DC Amperometry with Advanced Digital Filtering (ADF) |
| Filter Frequency Range | 0.5–0.001 Hz (decade steps: 1, 2, 5) |
| Potential Range | ±2.00 V |
| Faraday Column Oven Dimensions | Height 37 cm |
| Temperature Range | Ambient +7 °C to 45 °C |
| Temperature Stability | ±0.1 °C |
| Flow Cell Types | Central-jet wall-type electrode (compatible with standard & capillary HPLC columns) and conventional thin-layer electrode |
| Electrode Configurability | Interchangeable working and reference electrodes (e.g., glassy carbon, gold, platinum, Ag/AgCl) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FEPID |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Photoionization Detector (PID) |
| Wavelength Range | 100–900 nm |
| Detection Principle | Emission-based Photoionization |
| UV Source | Dielectric Barrier Discharge (DBD) Ultraviolet Lamp |
| Noise Level | <1% RMS |
| Detection Limit | 1 ppb (for benzene-equivalent VOCs) |
| Baseline Drift | <1% over 24 h |
| Signal Channels | 4 independent analog/digital outputs |
| Calibration Accuracy & Repeatability | ±0.1% of full scale |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | SePdd |
| Quotation | Upon Request |
| Compatible Instrument | Gas Chromatograph |
| Instrument Type | Specialized Chromatographic Detector |
| Wavelength Range | 100 nm – 900 nm |
| Detection Mode | Emission |
| Light Source | Plasma Discharge |
| Noise | <1% |
| Detection Limit | 1 ppb |
| Baseline Drift | <1% |
| Signal Channels | 4 |
| Adjustment Accuracy / Repeatability | ±1% |