Chromatographic Detector
Filter
Showing 31–60 of 101 results
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | GC-EPD |
| Compatible Instrument | Gas Chromatograph |
| Detector Type | Plasma-Based Universal Detector |
| Wavelength Range | 100 nm – 900 nm |
| Detection Mode | Emission |
| Excitation Source | Radio-Frequency Plasma |
| Noise Level | 0.1 mV (RMS, 1 Hz bandwidth) |
| Detection Limit | 0.5 ppb (for halogenated compounds) |
| Baseline Drift | ≤1% over 24 h |
| Signal Channels | 4 independent analog inputs |
| Calibration Accuracy & Reproducibility | ±1% (full-scale) |
| Brand | Bettersize |
|---|---|
| Model | BeSEC |
| Type | Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC) Light Scattering Detector |
| Laser | 640 nm semiconductor laser, 10 mW output |
| Detection angles | 7° and 90° |
| Flow cell volume | 18 µL |
| Sampling rate | 5 Hz |
| Molecular weight range | 1,000 Da – 2 × 10⁷ Da (LS1), 1,000 Da – 2 × 10⁹ Da (LS2) |
| Radius of gyration (Rg) detection limit | >12 nm |
| Supported detection modes | Homopolymer mode, protein mode |
| Output parameters | Mn, Mw, Mz, Mp, polydispersity (PD), molecular weight distribution, concentration, dn/dc, Rg |
| Input interfaces | RI detector input, UV detector input, trigger signal input |
| Power supply | 100–240 VAC, 50/60 Hz, 4 A |
| Dimensions (L×W×H) | 450 × 325 × 157 mm |
| Weight | 11 kg |
| PC requirements | Windows 10/11 (64-bit) |
| Software language | English & Chinese |
| Compliance | Designed for GLP/GMP-aligned laboratory workflows |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | DDL301 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 190–900 nm |
| Detection Method | Photomultiplier Tube (PMT) |
| Light Source | High-Intensity Halogen Lamp |
| Evaporation Principle | Low-Temperature Nebulization & Drift Tube Evaporation |
| Compatibility | HPLC, UHPLC, and LC-MS Coupling |
| Detection Sensitivity | Mass-sensitive, independent of chromophore, fluorophore, or electrochemical activity |
| Gradient Compatibility | Fully compatible with gradient elution |
| Baseline Stability | High resistance to flow rate and temperature fluctuations |
| Physical Footprint | Compact benchtop design (W × D × H: 240 × 450 × 320 mm) |
| Brand | Chunhua |
|---|---|
| Origin | Shanghai, China |
| Model | ELSD-5000KS |
| Detection Principle | Evaporative Light Scattering (ELSD) + Diode Array Detection (DAD) |
| Gas Flow Range | 0–5 L/min |
| Nebulizer Pressure | 0–150 psi |
| Drift Tube Temperature | Ambient to 200 °C (±1 °C control accuracy) |
| Mobile Phase Flow Rate Compatibility | 0–200 mL/min |
| Light Source | Standard 650 nm laser + D₂/W lamp combination |
| Spectral Range | 200–800 nm (standard), optional 200–400 nm or 200–1100 nm |
| Wavelength Modes | Full-spectrum, multi-wavelength, dual-wavelength, single-wavelength |
| Fraction Capacity | 160 positions |
| Collection Mechanism | X-Y-Z three-axis robotic arm |
| Gas Supply | Compressed air or nitrogen |
| Software | ELSD-5000KS Preparative Chromatography Workstation |
| Compliance | Designed for GLP-compliant environments |
| Brand | CoMetro |
|---|---|
| Model | RI-2000 |
| Detector Type | Refractive Index Detector (RID) |
| Compatible System | Liquid Chromatography (HPLC/UHPLC) |
| Refractive Index Range | 1.00–1.75 |
| Flow Rate Range | 0.2–3.0 mL/min |
| Linear Range | 80 × 10⁻⁵ RIU |
| Noise Level | 5 × 10⁻¹⁰ RIU |
| Auto-Zero Range | 40 × 10⁻⁵ RIU |
| Auto-Zero Resolution | 5 × 10⁻¹⁰ RIU |
| Integrator Output | ±1 V |
| Recorder Output | ±10 V |
| Analog Input/Output | ±5 VDC (TTL/12 VDC compatible) |
| Cell Volume | 9 µL |
| Maximum Cell Pressure | 6 kg/cm² (≈0.6 MPa) |
| Temperature Control Options | Ambient, 35°C, or 55°C (microprocessor-controlled) |
| Dimensions | 58.4 × 45.7 × 21.3 cm (W × D × H) |
| Weight | 16 kg |
| Power Supply | 220 V, 50/60 Hz, 80 VA |
| Brand | CoMetro |
|---|---|
| Model | RI2000 |
| Detection Principle | Differential Refractometry |
| Refractive Index Range | 1.00–1.75 |
| Flow Rate Range | 0.2–3.0 mL/min |
| Linear Range | 0–1000 µRIU (80 × 10⁻⁵ RIU) |
| Noise Level | 5 × 10⁻¹⁰ RIU (typical) |
| Auto-Zero Range | ±40 × 10⁻⁵ RIU |
| Auto-Zero Resolution | 5 × 10⁻¹⁰ RIU |
| Cell Volume | 9 µL |
| Maximum Cell Pressure | 6 kg/cm² (≈0.6 MPa) |
| Temperature Control | Ambient, 35 °C or 55 °C (microprocessor-regulated) |
| Analog Outputs | ±1 V (integrator), ±10 V (recorder) |
| selectable gains | 10 mV, 100 mV, 1 V |
| Digital I/O | TTL-compatible inputs/outputs (5 Vdc or 12 Vdc) for marker, polarity, wash, auto-zero, temperature, solvent recirculator |
| Power Supply | 220 V AC, 50/60 Hz, 80 VA |
| Dimensions | 58.4 cm (W) × ? cm (D) × ? cm (H) |
| Weight | 16 kg (35 lbs) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Diode Array Detector (DAD) |
| Model | ICS-PDA |
| Wavelength Range | 190–800 nm |
| Detector Array | 1024-element photodiode array |
| Light Sources | Deuterium and tungsten lamps |
| Interface | USB + 4 analog outputs |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation in Chromeleon™ CDS |
| Baseline Drift | Low, enabling high reproducibility in quantitative UV-Vis chromatographic analysis |
| Brand | Elite |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Chromachem® |
| Detection Principle | Evaporative Light Scattering Detection (ELSD) |
| Compatible Systems | Liquid Chromatography (HPLC/UHPLC) |
| Light Source | High-Intensity Halogen Lamp |
| Photomultiplier Tube (PMT) | High-Sensitivity Detector |
| Evaporator Temperature Range | 20–100 °C |
| Nebulizer Temperature Range | 20–70 °C |
| Power Supply | AC 110/240 V, 50/60 Hz, 350 W |
| Dimensions (L×W×H) | 480 × 240 × 460 mm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | D1100 |
| Price Range | USD 2,800–7,000 (FOB) |
| Compatible Instrument | HPLC Systems |
| Detector Type | Ultraviolet-Visible (UV-Vis) Detector |
| Wavelength Range | 190–700 nm |
| Detection Mode | Absorbance (UV-Vis) |
| Light Source | Deuterium Lamp |
| Linear Range | 1.8 AU |
| Baseline Noise | ≤ ±1.0 × 10⁻⁵ AU |
| Baseline Drift | ≤ 2.0 × 10⁻⁴ AU/h |
| Power Supply | AC 220 V ±10%, 50 Hz / 100 W |
| Dimensions (L×W×H) | 420 × 260 × 160 mm |
| Weight | 12 kg |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | D3200 |
| Price Range | USD 7,000–14,000 (FOB) |
| Compatible Instrument | HPLC Systems |
| Detector Type | Ultraviolet-Visible (UV-Vis) Detector |
| Wavelength Range | 235–254 nm |
| Detection Method | Dual-Beam Optical Path |
| Light Sources | Deuterium Lamp & Tungsten-Halogen Lamp |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | D3270 |
| Price Range | USD 14,000–28,000 (FOB) |
| Compatible Systems | HPLC, UHPLC |
| Detector Type | Evaporative Light Scattering Detector (ELSD) |
| Operating Frequencies | 10 Hz / 20 Hz / 50 Hz / 100 Hz |
| Detection Principle | High-Sensitivity Photomultiplier Tube (PMT) |
| Light Source | 650 nm, 30 mW Stable Laser Diode |
| Baseline Noise | < 0.01 mV (RMS, 1 s bandwidth) |
| Baseline Drift | < 0.05 mV / 30 min |
| Signal Interfaces | RS-232, RS-485, USB 2.0, Ethernet (UDP protocol) |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DAD3100 |
| Instrument Type | Diode Array Detector (DAD) |
| Wavelength Range | 190–800 nm |
| Detection Method | Diode Array |
| Light Source | Tungsten-Halogen & Deuterium Lamps |
| Baseline Noise | ≤ ±1.0 × 10⁻⁵ AU |
| Baseline Drift | ≤ 2.0 × 10⁻⁴ AU/h |
| Dimensions | 500 × 300 × 175 mm (L×W×H) |
| Weight | 18 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 80 W |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | MFD3100 |
| Price Range | USD 7,000–14,000 (FOB) |
| Compatible Instrument | HPLC Systems |
| Detector Type | Fluorescence Detector (FD) |
| Excitation Wavelength Ranges | 324–350 nm |
| Detection Method | Confocal Optical Path System |
| Light Source | Triple High-Stability LED Array with Motorized Auto-Switching Mechanism |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | RI-201H |
| Price Range | USD 7,000–14,000 (FOB) |
| Compatible Instrument | HPLC Systems |
| Detector Type | Differential Refractive Index Detector |
| Noise | ≤2.5×10⁻⁹ RIU (Standard Response Time) |
| Refractive Index Range | 1.00–1.75 |
| Detection Range | 0.25–512×10⁻⁶ RIU |
| Linearity Range | 6×10⁻⁴ RIU |
| Auto-Zero Function | Optical & Electronic |
| Drift | ≤2.0×10⁻⁷ RIU/h (deionized water, 1 mL/min, purge off) |
| Response Times | 0.1, 0.25, 0.5, 1.0, 1.5, 2.0, 3.0, 6.0 s |
| Temperature Control | Off / 30–50 °C (1 °C increments) |
| Heater Element Max Temp | 77 °C |
| Flow Cell Volume | 8 μL |
| Max Flow Rate | 10 mL/min (water mobile phase) |
| Max Pressure Rating | 0.05 MPa |
| Wetted Materials | SUS316 Stainless Steel, PTFE (Teflon), Fused Silica |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz, ≤150 VA |
| Dimensions (L×W×H) | 400×260×150 mm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UV3100 |
| Compatible Instrument | HPLC Systems |
| Detector Type | UV-Vis Absorbance Detector |
| Wavelength Range | 190–700 nm |
| Detection Principle | UV-Vis Absorption Spectrophotometry |
| Light Source | Deuterium Lamp |
| Baseline Noise | ≤ ±0.5 × 10⁻⁵ AU |
| Baseline Drift | ≤ 1.0 × 10⁻⁴ AU/h |
| Linear Dynamic Range | 2.0 AU |
| Flow Cell Options | Analytical Cell (10 mm pathlength, 11 µL volume) |
| Power Supply | AC 220 V ±10%, 50 Hz / 100 W |
| Dimensions (L×W×H) | 420 × 300 × 175 mm |
| Weight | 16 kg |
| Analog Output | Optional DA output interface |
| Brand | Dongxi Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | EL-100 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 450 nm (blue LED) |
| Detection Method | Photomultiplier Tube (PMT) |
| Light Source | High-Stability Blue LED |
| Evaporation Zone Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Solvent Flow Rate Compatibility | 10 µL/min – 3 mL/min |
| Nebulizing Gas Flow Rate | 300 mL/min – 1.5 L/min |
| Nebulizing Gas Pressure | 0.2–0.5 MPa |
| Detection Limit | <1 ng (glucose, direct injection) |
| Baseline Noise | <0.1 mV (at 1 mL/min mobile phase flow) |
| Dimensions (W×D×H) | 165 × 470 × 580 mm |
| Brand | Instrumax |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CADetector a1 |
| Price Range | USD 42,000 – 49,000 (FOB Tianjin) |
| Compatible Systems | HPLC, UPLC, SFC |
| Detector Type | Charged Aerosol Detector (CAD), classified as a universal mass-sensitive detector distinct from ELSD |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ELSD-2000KS |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Method | Dual-beam |
| Light Source | Xenon lamp |
| Laser Wavelength (Standard) | 650 nm |
| Gas Flow Range | 0–5 L/min |
| Nebulization Pressure | 0–100 psi |
| Temperature Control Range | Ambient to 150 °C (±1 °C resolution) |
| Mobile Phase Flow Rate Compatibility | 0–5 mL/min |
| Detector | Imported large-area silicon photodiode |
| Power Supply | 220 V AC |
| Compatible Carrier Gases | Compressed air or nitrogen |
| Core Components | Stainless-steel evaporation tube, maintenance-free stainless-steel nozzle, laser source, photodetector, dedicated ELSD-2000KS chromatography workstation |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ELSD-3000KS |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Method | Dual-beam |
| Light Source | Xenon Lamp |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Gas Flow Range | 0–5 L/min |
| Nebulizer Pressure | 0–100 psi |
| Temperature Control Range | Ambient to 150 °C (±1 °C resolution) |
| Mobile Phase Flow Rate Compatibility | 0–0.5 mL/min |
| Light Source (Standard) | 650 nm Laser |
| Detector | Imported Photomultiplier Tube (PMT) |
| Power Supply | 220 V AC |
| Compatible Carrier Gases | Compressed Air or Nitrogen |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 195–650 nm (Excitation), 200–800 nm (Emission) |
| Measurement Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Flow Rate Range | 0–10 mL/min |
| Flow Accuracy | ±0.3% |
| Flow Precision (RSD) | ≤0.1% |
| Injection Valve Pressure Rating | 35.0 MPa (5000 psi) |
| Spectral Bandwidth | 10 nm / 20 nm |
| AD Resolution | 24-bit |
| Software Platform | FStar-2000 Chromatography Data System (CDS) for Windows 7/8/10 |
| Compliance | Fully aligned with Chinese Pharmacopoeia (2015 Edition), GLP/GMP principles, and FDA 21 CFR Part 11 audit trail requirements |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KH-FL20E |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation Wavelength Range | 190–800 nm |
| Emission Wavelength Range | 190–800 nm |
| Spectral Bandwidth Options | 2 / 5 / 10 / 20 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Light Source | Solid-State Discharge Lamp |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range (Flow Cell) | Ambient to 50 °C |
| Compliance | Meets GMP/GLP requirements |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-FL30E |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 190–900 nm (Excitation & Emission) |
| Measurement Mode | Dual-Beam |
| Light Source | 150 W DC Xenon Lamp |
| Spectral Bandwidth | 10 nm / 15 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range (Flow Cell) | Ambient to 50 °C |
| Software | FM-2000 Chromatography Workstation |
| Compliance | Chinese Pharmacopoeia (2010 & 2015 Editions), GLP/GMP-ready, LIMS-compatible, FDA 21 CFR Part 11 support (audit trail & electronic signature enabled) |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KH-FL30Plus |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 190–900 nm (Excitation & Emission) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Spectral Bandwidth | 10 nm / 15 nm |
| Light Source | 150 W DC Xenon Lamp |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range | Ambient to 50 °C (Optional) |
| Compliance | Chinese Pharmacopoeia 2010/2015 Edition, GLP/GMP-Ready, LIMS-Compatible |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | KH-FL50E |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation/Emission Wavelength Range | 190–900 nm |
| Detection Modes | Fluorescence, Phosphorescence, Chemiluminescence |
| Light Source | 150 W DC Xenon Lamp or 5 W Pulsed Xenon Lamp |
| Monochromator | 1200-line Holographic Grating |
| Spectral Bandwidth (Excitation & Emission) | 5/10/15/20 nm selectable |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| AD/DA Resolution | 24-bit |
| Flow Cell Temperature Control | 5–50 °C |
| Detector Options | Single-Photon Counting Module (SPCM) or Variable-Voltage High-Sensitivity PMT |
| Compliance | Chinese Pharmacopoeia 2010/2015, GLP/GMP-ready, LIMS-compatible |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Model | ELSD-5000KS |
| Wavelength Range | 200–800 nm (standard), optional 200–400 nm or 200–1100 nm |
| Detection Mode | Dual-beam |
| Light Source | Standard 650 nm laser + D₂/W lamp combination |
| Nebulizer Gas Flow | 0–5 L/min |
| Nebulizer Pressure | 0–150 psi |
| Drift Tube Temperature | Ambient to 200 °C (1 °C resolution) |
| Mobile Phase Flow Rate | 0–200 mL/min |
| Fraction Capacity | 160 positions |
| Collection Mechanism | X-Y-Z three-axis robotic arm |
| Gas Supply | Compressed air or nitrogen |
| Software | ELSD-5000KS Preparative Chromatography Workstation |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | UV+2000 |
| Instrument Type | Fluorescence Detector (FD) Compatible Derivatization Device |
| Wavelength Range | 195–600 nm |
| Measurement Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Maximum Flow Rate | 2 mL/min (customizable) |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-ZY10E |
| Instrument Type | Fluorescence Detector-Compatible Post-Column Derivatization System |
| Temperature Range | Ambient to 150 °C |
| Temperature Accuracy | ±0.25 °C |
| Temperature Resolution | ±0.1 °C |
| Derivatization Pump Flow Rate | 0–10 mL/min |
| Flow Repeatability | ±0.1% |
| Reaction Coil Length | 10 m |
| Reactor Configuration | Modular, Single or Dual Cartridge Options |
| Mixing Architecture | Sealed Continuous-Loop Multi-Directional Flow Reactor |
| Peak Broadening Reduction | Optimized via Low-Dispersion Reaction Core Design |
| Brand | LABA (Tianjin) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 2000 |
| Instrument Type | UV-Vis Absorbance Detector |
| Wavelength Range | 190–900 nm |
| Optical Design | Dual-Beam |
| Light Source | Deuterium Lamp |
| Spectral Scanning Capability | Yes |
| Flow Cell Options | Stainless Steel & Kel-F (Chemically Inert, Biocompatible) |
| Programmable Peak Detection | Yes |
| Baseline Correction Algorithm | Adaptive |
| Lamp Access | Side-Mounted for Quick Replacement |
| Flow Cell Access | Side-Mounted for Tool-Free Exchange |
| Brand | Labman (formerly LABA Tianjin) |
|---|---|
| Model | LB8120 |
| Detector Type | Ultraviolet-Visible Absorbance Detector |
| Wavelength Range | 190–900 nm |
| Optical Design | Dual-Beam with Shielded Optics |
| Light Source | Deuterium Lamp |
| Grating Type | Holographic Concave Grating |
| Detection Mode | Programmable Dual-Wavelength Simultaneous Monitoring |
| Spectral Acquisition | Continuous Rapid Scanning |
| Lamp Control | Fully Automated Start/Stop with Warm-up Optimization |
| Origin | USA-assembled with global supply chain integration |
| Compliance | Designed to support GLP/GMP workflows and ASTM E260, ISO 17025-aligned operation |