Chromatography Instruments
Filter
Showing 331–360 of 701 results
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | EasyPrep Eco |
| Price | Upon Request |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.1–150 mL/min |
| Maximum Operating Pressure | 1.0 MPa |
| UV-Vis Wavelength Selection | 254–800 nm (discrete wavelength options) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EasyPrep HP |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Solvent Delivery | Binary Gradient |
| Flow Rate Range | Up to 100 mL/min |
| Maximum Pressure | 3000 psi (20.7 MPa) |
| UV Detection Wavelength Options | 200–400 nm or 200–800 nm |
| Column ID Compatibility | 10–50 mm |
| Collection Modes | Full Fraction, Peak-Based, Time-Based |
| Dimensions (L×D×H) | 587 × 400 × 565 mm |
| Safety Features | Leak Detection, Over-Pressure Alarm |
| Software | Real-Time Gradient Editing, Drag-and-Drop Gradient Curve Adjustment, On-the-Fly Flow Rate Modification |
| Tube Rack Recognition | Supported |
| Regulatory Compliance Support | GLP-compliant audit trail logging (software-configurable), FDA 21 CFR Part 11 readiness (user authentication & electronic signature modules available) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China-Made) |
| Model | INNOTEG EasyPrep MP |
| Instrument Type | Medium- to Low-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ≤ ±2% |
| Maximum Operating Pressure | 200 psi |
| UV Detection Wavelength Range | 200–400 nm |
| Baseline Noise | 1 × 10⁻⁴ AU (at 254 nm, water) |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CombiFlash EZ Prep |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–200 mL/min |
| Flow Rate Precision | RSD ≤ 1% |
| Maximum Operating Pressure | 3500 psi (240 bar) |
| Wavelength Range | 200–400 nm (UV), 200–800 nm (UV-VIS) |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | 1 × 10⁻⁵ AU |
| Data Acquisition Rate | 200 Hz |
| Column Compatibility | Up to 50 mm ID, down to 5 µm particle size packing |
| Solvent Switching | Fully Automated, User-Initiated or Method-Triggered (Normal-Phase to Reversed-Phase) |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CombiFlash NextGen |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 1–300 mL/min |
| Flow Accuracy | RSD ≤ 0.01% |
| Flow Precision | RSD ≤ 0.1% |
| Maximum Operating Pressure | 300 psi (20 bar) |
| Wavelength Range | 190–800 nm (UV-Vis) |
| Wavelength Reproducibility | ±1 nm |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Detection Options | UV, UV-Vis, ELSD, Mass Spectrometry (MS)-compatible interface |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CombiFlash Torrent |
| Application Level | Industrial-Scale Preparation |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 1 L/min |
| Flow Accuracy | <1% |
| Flow RSD | <1% |
| Maximum Operating Pressure | 100 psi |
| Wavelength Range | 190–800 nm (UV-Vis) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | ±1 nm |
| Sample Capacity | Up to 600 g per run |
| Column Compatibility | RediSep® (80 g – 3 kg), glass columns, third-party cartridges |
| Software | PeakTrak™ v5.0 with real-time gradient editing, method scaling, and RFID-enabled column recognition |
| Detection | Dual-wavelength UV/Vis detector with auto-zero baseline correction |
| Fraction Collection | Foxy R2 fraction collector or motorized 6-port switching valve |
| Safety Systems | Integrated pressure transducer, solvent vapor sensor, automatic shutdown on fault |
| Fluidic Architecture | Fully grounded stainless-steel and PEEK tubing, large-bore flow path |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Isolera™ One |
| Price Range | USD 42,000–56,000 (est.) |
| Application Level | Laboratory-Scale Purification |
| Instrument Type | Medium-Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi (13.8 bar) |
| UV Detection Wavelength Range | 200–400 nm |
| Gradient Capability | Binary with Optional Tertiary Solvent Addition (Constant-Ratio Modifier Injection) |
| Column Compatibility | Biotage SNAP, SNAP Ultra, ZIP, and ZIP Sphere columns (5 g to 750 g) |
| Brand | JKRD |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SP7800 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Warranty & Service | On-site Installation, Commissioning, and Comprehensive After-Sales Support |
| Brand | KA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | hytrace Integrated Analyzer |
| Instrument Type | Portable Gas Chromatograph |
| Application Scope | General-purpose, Hydrogen Purity Monitoring |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Ramp Rate | Up to 75 °C/min |
| Cool-down Time | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Control Range | 30–100 mL/min |
| Carrier Gas Pressure Control Range | 90–100 psig |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Domain | Food Safety & Agricultural Residue Testing |
| Oven Temperature Range | +5 °C to 400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Time (from 400 °C to 50 °C) | ≤4 min |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Temperature Range | +5 °C to 400 °C |
| Injector Pressure Setting Range | 0–0.04 MPa |
| Total Injector Flow Setting Range | 0–1000 mL/min |
| Column Oven Dimensions | 280 × 280 × 180 mm |
| Weight | 56 kg |
| Power Consumption | 2000 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Anters-1500G |
| Instrument Type | Ambient-Temperature GPC System |
| Pump Flow Range | 0.001–10 mL/min |
| Pump Pressure Range | 0–40 MPa |
| Refractive Index Detector Drift | <1×10⁻⁷ RIU/h |
| RI Detector Cell Volume | 9 µL |
| UV Detector Wavelength Range | 100–200 nm |
| UV Detector Noise | <0.25×10⁻⁵ AU |
| Column Oven Temperature Range | 4 °C to 40 °C above ambient |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Anters-1500G (with Column Kit) |
| Instrument Type | High-Temperature GPC System |
| Key Specifications | Pump Flow Range: 0.001–10 mL/min |
| Max Pressure | 40 MPa |
| Flow Precision | <0.3% RSD |
| Flow Accuracy | <0.06% |
| Autosampler Capacity | 144 × 2 mL vials (standard) |
| Injection Volume | 0.1–100 µL |
| Injection Precision | <0.3% RSD |
| Carryover | <0.1% |
| Column Oven Temp Range | 4–100 °C |
| Temp Stability | ±0.15 °C |
| RI Detector Range | 1.00–1.75 RIU |
| Noise | ≤5×10⁻⁷ RIU |
| Drift | ≤5×10⁻⁶ RIU/30 min |
| Flow Cell Volume | 8 µL |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GoodLook-1000 |
| Instrument Type | TLC Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White light (400–700 nm) |
| Sample Stage Capacity | Accommodates 200 mm × 200 mm TLC plates |
| Maximum Scanning Speed | 100 mm/s |
| Camera Resolution | 12 MP |
| Exposure Time Range | 0–10 s |
| Gain Adjustment | 0–100% |
| Imaging Modalities | Visible, UV, Fluorescence, Chemiluminescence |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GoodLook-2000 |
| Instrument Type | TLC Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White light (400–700 nm) |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC plates |
| Scanning Speed | Max 100 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GoodSee-20E |
| Instrument Type | TLC Imaging System |
| Imaging Wavelengths | 254 nm UV, 365 nm UV, Visible Light |
| Maximum Imaging Area | 200 × 200 mm |
| Camera Resolution | ≥12 MP |
| Power Supply | 220 V, 50 Hz, 90 W |
| Light Source Power | 30 W per channel |
| Scanning Speed | Up to 100 mm/s |
| Interface | USB |
| Software Platform | Windows 7 / 10 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | TLC Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Optional Nitrogen Purge |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Maximum Scanning Speed | 100 mm/s |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-3500Plus II |
| Instrument Type | TLC Densitometer & Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence, Chemiluminescence |
| Wavelength Range | 190–1000 nm |
| Light Sources | Tungsten-Halogen Lamp, Deuterium Lamp, Mercury Lamp (Auto-Switching) |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Option |
| Spectral Bandwidth | 5 nm / 10 nm / 20 nm (Selectable |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | <0.1 nm |
| Minimum Spatial Resolution | 10–25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light (Fully Automated Control) |
| Sample Stage Capacity | 200 mm × 200 mm TLC Plate (Customizable to 300 mm × 200 mm) |
| Scan Speed | 0–120 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PrepChromaster-7000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–250 mL/min (single pump), 0–500 mL/min (dual pump) |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.5% |
| Maximum Operating Pressure | 200 bar (standard), upgradable to 300 bar |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | PrepChromaster-8000 |
| Flow Rate Range | 0–200 mL/min (single pump), 0–400 mL/min (dual pump) |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 1% |
| Maximum Pressure | 15 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Brand | KEZHE / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | PuriMaster-2000 |
| Application Level | Laboratory-Scale R&D |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–100 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 1.0% |
| Maximum Pressure | 4000 PSI (27.6 MPa) |
| Wavelength Range | 190–850 nm (dual-wavelength simultaneous detection) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±3×10⁻⁵ AU (254 nm) |
| Data Acquisition Rate | 5 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PuriMaster-3000A |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0–250 mL/min (single pump), 0–500 mL/min (dual pump) |
| Flow Accuracy | RSD = 0.5% |
| Flow Precision | RSD = 1.0% |
| Maximum Pressure | 50 bar (standard) |
| Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection) |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Brand | KEZHE / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | PuriMaster-5000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0–100 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.5% |
| Maximum Pressure | 4000 PSI (27.6 MPa) |
| Wavelength Range | 190–850 nm (simultaneous quad-wavelength detection) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PuriMaster-7000 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–100 mL/min (customizable up to 200 mL/min) |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 1.0% |
| Maximum Pressure | 4000 psi (27.6 MPa) |
| Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.4 nm |
| Baseline Noise | ≤3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Autosampler Capacity | 42 or 144 positions |
| Fraction Collector Capacity | 160 × 15 × 150 mm test tubes |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PuriSmart-100 |
| Application Level | Laboratory-Scale R&D |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0–50.00 mL/min (per pump) |
| Maximum Operating Pressure | 30 MPa |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | ±0.1 mAU (at 254 nm) |
| Baseline Drift | 0.2 mAU/h (at 254 nm) |
| Detection Modes | Dual-Wavelength UV-VIS, Online UV-VIS Spectral Scanning |
| Gradient Capability | Binary, Low-Delay Mixing |
| Fraction Collection | X-Y Robotic Fraction Collector |
| Software Compliance | Audit Trail, User Management, Data Integrity per FDA 21 CFR Part 11 & GLP Principles |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PuriSmart-200 |
| Application Level | Laboratory-Scale R&D |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0–100 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Range | 0–30 MPa |
| Pressure Pulsation | < ±0.2 MPa |
| Wavelength Range | 190–850 nm (dual-wavelength simultaneous detection) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ±0.1 mAU at 254 nm |
| Baseline Drift | 0.2 mAU/30 min at 254 nm |
| Sample Injection Volume | 5 mL (standard), customizable |
| Detector Light Source | Deuterium–Tungsten dual-lamp assembly |
| Monochromator | 1200-line/mm holographic grating |
| Fraction Collection | X-Y matrix-type collector |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ScalePuri-100 |
| Application Level | Laboratory & Pilot-Scale |
| Instrument Type | Medium-to-High Pressure Preparative LC |
| Flow Rate Range | 0–100 mL/min (pump), up to 800 mL/min (gradient mixing) |
| Flow Accuracy | RSD = 0.5% |
| Flow Precision | RSD = 1% |
| Max Operating Pressure | 150 bar |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Detection Mode | UV-VIS with Quad-Wavelength Real-Time Monitoring |
| Column Compatibility | Axial Compression Columns, 50–100 mm ID |
| Prep Capacity | Gram-scale (up to 100 g per run) |
| System Control | Fully Software-Driven with Audit Trail, User Management, and Electronic Signature Support |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ScalePuri-150 |
| Application Level | Laboratory & Pilot-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–1000 mL/min |
| Flow Accuracy | ±2.0% |
| Flow Precision | ±1.5% (injector pump) |
| Maximum Pressure | 10 MPa (100 bar) |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | ±0.1 mAU @ 254 nm |
| Baseline Drift | 0.2 mAU/30 min @ 254 nm |
| Data Acquisition Rate | Not specified |
| [Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200E |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Capacity | 144 × 2 mL vials |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | 10–80 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz] |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200F1 |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Tray Capacity | 144 positions (2 mL vials) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20–100 °C |
| Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200F2 |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Capacity | 144 positions (2 mL vials) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20–100 °C |
| Wavelength Range (Fluorescence Detector) | 190–900 nm |
| Data Acquisition Rate | 100 Hz |