Chromatography Instruments
Filter
Showing 301–330 of 1564 results
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | DD80 |
| Instrument Type | Automated TLC Imaging & Densitometry System |
| Operation Mode | Fully Automatic |
| Detection Mode | Low-Fluorescence Substance Imaging |
| Wavelength Options | 254 nm and 366 nm UV |
| Light Sources | White LED, UV Fluorescent Lamps, UV LEDs |
| Imaging Sensor | 24-Megapixel Full-HD Digital Camera |
| Spectral Bandwidth Management | Auto Background Correction & Real-Time Image Optimization |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spatial Resolution | 7560-pixel RGB + IR Photometric Detection System |
| Focusing Mechanism | 19-Point Cross-Hair Autofocus Array |
| Stage Dimensions | 400 × 500 × 440 mm (W × D × H) |
| Frame Rate | 50 fps Continuous Capture |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera |
| Instrument Type | Medium- to Low-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–200 mL/min |
| Maximum Pressure | 145 psi (10 bar) |
| Detection Wavelengths | 254 nm, 200–400 nm, 200–800 nm (optional) |
| UV Flow Cell Path Length | 0.3 mm |
| Fraction Collection Tube Diameters | 13, 16, 18, or 25 mm |
| Solvent Channels | 2 or 4 (configurable) |
| Sample Loading Capacity | mg to 75 g |
| Application Level | Laboratory-Scale Purification |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera Dalton 2000 |
| Application Level | Laboratory |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.2% |
| Maximum Operating Pressure | 145 psi |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ≤ 2 × 10⁻⁵ AU (peak-to-peak, methanol, 1 mL/min, 254 nm, 20 °C) |
| Data Acquisition Rate | 10 Hz |
| Mass Range | m/z 80–2000 |
| Ionization Modes | Simultaneous Positive/Negative APCI (ESI optional) |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera LS |
| Application Level | Laboratory-scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 50–500 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.2% |
| Maximum Operating Pressure | 145 psi (10 bar) |
| Wavelength Range | 200–400 nm (standard UV), optional 200–800 nm (UV-Vis) |
| Wavelength Reproducibility | ±0.1 nm |
| Baseline Noise | ≤2×10⁻⁵ AU (peak-to-peak, methanol, 1 mL/min, 254 nm, 20 °C) |
| Data Acquisition Rate | 10 Hz |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | H5220(C) |
| Detection Limit | <1 µg/m³ (for benzene) |
| Repeatability | 1% |
| Linear Range | 10⁵ |
| Column Oven Temperature Range | Ambient to 200 °C (programmable) |
| Zero Drift | ≤1% FS/month |
| Span Drift | <1% FS/24 h |
| Power Supply | Internal Li-ion battery (6 h operation) |
| Operating Environment | −20 °C to +45 °C, 20–90% RH |
| Gas Inlet | 1/8″ stainless steel Swagelok fitting |
| Detector | Photoionization Detector (PID) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~10 min (400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–10,000 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | Pure C-815 / Pure C-810 |
| Application Level | Laboratory Grade |
| Instrument Category | Low-to-Medium Pressure Preparative LC |
| Flow Rate Range | 1–250 mL/min |
| Flow Accuracy | ±3% RSD |
| Flow Precision | ±0.5% RSD |
| Maximum Operating Pressure | 50 bar |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.4 nm |
| Baseline Noise | 5 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | Pure C-835 / Pure C-830 |
| Application Level | Laboratory Grade |
| Instrument Category | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–100 mL/min |
| Flow Accuracy | ±3% RSD |
| Flow Precision | ±0.5% RSD |
| Maximum Pressure | 300 bar |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.4 nm |
| Baseline Noise | 5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | Pure C-850 |
| Application Level | Laboratory Grade |
| Instrument Category | High-Pressure Preparative LC System |
| Flow Rate Range | 1–250 mL/min |
| Flow Accuracy | RSD < 3% |
| Flow Precision | RSD < 0.5% |
| Maximum Pressure | 300 bar |
| Wavelength Range | ±2 nm (200–800 nm) |
| Wavelength Repeatability | 0.4 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | Pure Essential System |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0–300 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision | ±1% at 5–250 mL/min |
| Maximum Pressure | 50 bar |
| UV Wavelength Options | Fixed wavelengths at 254, 275, 325, and 365 nm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Model | Sepacore |
| Pressure Range | Up to 50 bar (725 psi) |
| Flow Rate | 2.5–250 mL/min |
| Column ID Range | 15–100 mm |
| Max Sample Load | 100 g (glass columns) |
| Detector Wavelength | 190–745 nm |
| Gradient Capability | Binary to Quaternary, 0–100% B, linearity ±2% |
| Software | SepacoreControl (PC-based, optional 21 CFR Part 11 compliance) |
| Pump Type | Tri-piston, pulse-free, solvent-compatible with acids/bases/organics |
| Column Options | Glass (coated), polypropylene flash columns, cartridge-based packing systems |
| Fraction Collection Modes | Time-, volume-, or UV peak-triggered |
| Safety Features | Grounded metal fraction collector arm, transparent pressure-rated glass columns, integrated pressure sensors and level monitoring |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Preparative SFC System |
| Model | SFC-250 |
| Flow Rate Range | 0–250 mL/min (including up to 40% modifier) |
| Maximum Operating Pressure | 400 bar (CO₂ and modifier pumps) |
| Detector Options | Diode Array Detector (DAD), Mass Spectrometer (MS), Evaporative Light Scattering Detector (ELSD) |
| Modifier Channels | 4 |
| Injection Loop Volume | 2.5 mL |
| Column Capacity | Up to 10 columns (2 mounted simultaneously) |
| Column Dimensions | ID 15–30 mm, max. length 250 mm |
| Column Oven Temperature Range | Ambient to 70 °C |
| Gradient Capability | Isocratic, binary linear, or step gradients |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Preparative SFC System |
| Model | SFC-50 |
| Flow Rate Range | 1–50 mL/min (including up to 40% modifier) |
| Maximum Pressure | 400 bar |
| Detector Options | DAD, ELSD, Mass Spectrometer (MS) |
| Column Capacity | Up to 10 columns (2 mounted simultaneously) |
| Column Dimensions | ID 4–16 mm, max. length 250 mm |
| Column Oven Temperature Range | Ambient to 70 °C |
| UV Wavelength Range (DAD) | 190–720 nm |
| Power Supply | 230 V ±10%, 50/60 Hz |
| Operating Environment | 15–25 °C, 45–75% RH |
| Dimensions (W×D×H) | 560 × 600 × 880 mm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SFC-660 |
| Instrument Type | Preparative |
| Flow Rate Range | 0–660 mL/min (including up to 40% modifier) |
| Maximum Operating Pressure | 400 bar |
| Detector Options | Diode Array Detector (DAD), Electrospray Light Scattering Detector (ELSD), Mass Spectrometer (MS) |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | ADC 3 |
| Instrument Type | Automatic Thin-Layer Chromatography (TLC) Development System |
| Operation Mode | Fully Automated |
| Sample Format | HPTLC plates up to 20 × 10 cm |
| Chamber Configuration | Dual-saturation chambers with integrated RH control |
| Compliance | cGMP/GLP, FDA 21 CFR Part 11 compliant |
| Software Control | visionCATS v3.x or later |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | AMD 2 |
| Instrument Type | Thin-Layer Chromatography (TLC) Multiple Development System |
| Compliance | GLP/GMP-Compliant |
| Control | Programmable, CCD-Monitored |
| Solvent Capacity | Up to 5 solvents |
| Development Stages | Multi-step, Gradient Elution Capable |
| Max. Separation Density | ~40 components within 80 mm |
| Automation Level | Fully Automated Pre-saturation, Development, Drying |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | ATS 4 |
| Instrument Type | Automatic Thin-Layer Chromatography Sampler |
| Sampling Modes | Contact (spot) and Non-contact Pneumatic Spray (band/square) |
| Sample Volume Range | 100 nL – 1 mL |
| Precision | ±1 nL / ±2 nL / ±10 nL (for 10 µL / 25 µL / 100 µL syringes) |
| Plate Capacity | Up to 20 × 20 cm, thickness up to 4 mm |
| X-axis Resolution | 0.1 mm/step (80 steps/mm), travel 5–195 mm |
| Y-axis Resolution | 0.1 mm/step (40 steps/mm), travel 5.0–195.0 mm |
| Sample Carrier | 66 × 2 mL vials (12 × 32 mm) or optional 96-well microtiter plate |
| Operating Pressure | 4–6 bar (65–87 psi), compressed air or nitrogen |
| Gas Flow Rate | 0.2–0.3 L/min (spot mode) |
| Integrated Heating Function | Yes |
| Syringe Options | 10 µL, 25 µL, 100 µL |
| Onboard Microprocessor Control | Yes |
| Software Interface | winCATS v1.4.12 or higher |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | BioLuminizer® 2 |
| Instrument Type | TLC Imaging System |
| Detector Technology | Cooled CCD with 65% Quantum Efficiency |
| Data Depth | 16-bit |
| Pixel Resolution | High Spatial Resolution (Optimized for TLC Plate Detail Capture) |
| Application Focus | Bioluminescent Bioautography Coupled with Planar Chromatography |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | Derivatizer |
| Operation Mode | Automatic |
| Instrument Type | Preparative Thin-Layer Chromatography System |
| Compliance | Designed for GLP-compliant laboratories |
| Solvent Compatibility | All conventional organic and aqueous solvents |
| Reagent Consumption | ~3 mL for 20 × 10 cm plates, ~4 mL for 20 × 20 cm plates |
| Enclosure | Sealed, fume-controlled chamber |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | HPTLC PRO |
| Instrument Type | Preparative TLC System |
| Operation Mode | Fully Automatic |
| Sample Capacity | Up to 75 samples per run |
| Plate Capacity | Up to 5 TLC plates simultaneously |
| Solvent Systems | Up to 3 different developing solvents in one sequence |
| Software Compliance | FDA 21 CFR Part 11 compliant |
| Module Dimensions | 384 × 550 × 510 mm (W × D × H) |
| Brand | CAMAG (distributed by JHT / Yichenghengda) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | CAMAG TLC Systems (e.g., ATS 4, Linomat 5, Nanomat 4, ADC 2, AMD 2, TLC Visualizer 2, TLC Scanner 4, TLC-MS Interface 2, visionCATS 5) |
| Pricing | Upon Request |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | Linomat 5 |
| Instrument Type | Thin-Layer Chromatography (TLC) Sample Spotter |
| Regulatory Compliance | IQ/OQ Qualified |
| Software Integration | visionCATS v3.x or later |
| Application Environment | GLP/GMP-Compliant Laboratories |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Kit Type | Standard TLC Basic Toolset |
| Application | Preparative and Analytical TLC |
| Compliance | Designed to Support ASTM D7925, ISO 17025–Compliant Workflows |
| Software Integration | Compatible with CAMAG VisionCats (Optional) |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC Scanner 4 |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–900 nm |
| Light Sources | Deuterium Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp (automatically switchable) |
| Wavelength Reproducibility | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Sample Stage Dimensions | 200 × 200 mm |
| Scanning Speed | 1–100 mm/s |
| Regulatory Compliance | Fully compliant with FDA 21 CFR Part 11 for electronic records and signatures |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC Visualizer 3 |
| Light Sources | 254 nm short-wave UV (epi-illumination), 366 nm long-wave UV (epi-illumination), white light (epi-illumination and trans-illumination) |
| Camera Sensor | High-resolution industrial CMOS |
| Software Platform | visionCATS v3.x or later |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC-MS Interface 2 |
| Instrument Type | TLC–MS Coupling Interface |
| Compatibility | Universal LC-MS Systems (ESI, APCI, MALDI sources) |
| Operation Mode | Online and Offline Elution |
| Solvent Consumption | Low (≤ 200 µL per band) |
| Positioning Accuracy | ≤ ±50 µm |
| Washout Function | Integrated reverse-flow purge to prevent channel clogging |
| Sample Recovery | Direct collection into vials (1.5 mL or 2 mL) for downstream analysis (NMR, FTIR, ESI-MS, MALDI-MS) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Capel-205 |
| Pricing | Upon Request |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cathodeon |
| Pricing | Available Upon Request |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy 2.0 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 4–250 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 300 bar |
| Wavelength Range | 190–500 nm |
| Wavelength Repeatability | ±3 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-1000 |
| Instrument Type | Fast Liquid Chromatography System |
| Flow Rate Range | 0.1–100.0 mL/min (0.1 mL/min increment) |
| Maximum Operating Pressure | ≤20 MPa |
| Fraction Collection Options | F1–F4 standard tube racks (13 mm, 15 mm, 18 mm, 25 mm OD), F5 conical flask rack (up to 100 mL |
| Sample Injection Volume Range | up to 1 L |
| Temperature Control | Ambient only |
| Wavelength Range | Dual-channel UV-Vis detection at 200–400 nm and 200–800 nm (simultaneously selectable) |
| Data Acquisition Rate | Not specified |
