Chromatography Instruments
Filter
Showing 31–60 of 662 results
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM1000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Impurity Analysis |
| Oven Temperature Range | 4°C to 450°C |
| Temperature Stability | < ±0.05°C/h (after 30 min warm-up) |
| Cooling Rate | 300°C → 50°C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Maximum Temperature | 300°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NovaCHROM2000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal for Ultra-High-Purity Gas Analysis |
| Temperature Control Range | 5°C above ambient to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increment) |
| Cooling Rate | 1°C/sec (typical, from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–40 mL/min (EPC-controlled) |
| Carrier Gas Pressure Range & Control | 0–600 psi (EPC-controlled) |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–200 psi |
| Injector Total Flow Setting Range | 100–300 mL/min |
| Detector Options | ADD (Argon Discharge Detector), DID (Dielectric Barrier Discharge Ionization Detector), TCD, FID, FPD |
| Detection Limit | Sub-ppb to ppm level |
| Accuracy | ±1% of full scale |
| Response Time | 0.5 s (to 90% of final signal) |
| Warm-up Time | ≤60 min |
| Display | 6.5" color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity argon (Ar, N6.0, 99.9999% purity), flow 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 3 bar (300 kPa) |
| Electronic Pressure Control Input | 5–10 bar |
| Output Control Range | 0–5 bar |
| Standard Fittings | 1/8" stainless steel Swagelok® and VCR |
| Analog Output | 0–1 V (detector, system status, flow, maintenance, temperature, pressure) |
| Data Interface | TrendVision PLUS with 4–20 mA, Profibus, Modbus RTU, and RS-485 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (Rack Mount) | 19" (483 mm) W × 5U (219 mm) H × 22" (564 mm) D |
| Dimensions (Free-Standing) | H=900 mm, W=600 mm, D=400 mm |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NP9000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Temperature Control Range | +5°C to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increments) |
| Cooling Rate | 300°C to 50°C in ~5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–700 kPa |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Explosion Protection Rating | Ex pxb IIB+H2 T3 Gb |
| Column Oven Configuration | Multiple Independent Temperature-Controlled Ovens |
| Display | 12" Industrial Capacitive Touchscreen |
| Data Output Interfaces | 4–20 mA, Profibus, Modbus, Ethernet |
| Detector Options | DID, FID, TCD, FPD, PID, ADD |
| Column Types Supported | Packed, Micro-packed, Capillary |
| Valve Types | Stainless Steel / Hastelloy VICI Valco (4-, 6-, 8-, or 10-port) |
| Enclosure Material | Low-Carbon Steel with Front Safety Door |
| Gas Line Fittings | 1/8" Swagelok® or VCR (Hastelloy optional) |
| Operating Ambient Temperature | −10°C to +50°C |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ASTRA |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi |
| UV-Vis Detection | PDA Detector, 200–800 nm |
| Gradient Capability | Quaternary Solvent Selection |
| Column Compatibility | Normal- & Reversed-Phase Columns (4–800 g), Max. Sample Load: 80 g |
| Fraction Collection Modes | Full Collection, Peak-Based Collection, Manual Trigger, Time-Window Collection |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH II |
| Instrument Type | Fast Liquid Chromatography (Flash) |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi |
| Sample Injection Positions | 1–100 |
| Injection Volume Ratio | 1–10% |
| Temperature Control | 25°C (ambient, non-thermostatted) |
| Wavelength Range | 200–800 nm |
| Data Acquisition Frequency | Not specified (system supports real-time UV/VIS spectral scanning) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH MP200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative HPLC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm (standard detector), 200–800 nm (optional dual-range detector) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±1 nm |
| Baseline Noise | ≤3×10⁻⁴ AU |
| Data Acquisition Rate | 3 Hz |
| Gradient Configuration | Binary or Quaternary |
| Detection Modes | Single-Wavelength, Dual-Wavelength (independent collection & monitoring), Ratio-Based Triggering |
| Fraction Collection | Integrated 2D Fraction Collector with Adjustable Rack Mapping |
| Solvent Compatibility | All Common HPLC-Grade Organic and Aqueous Solvents |
| Safety Features | Real-Time Pressure Monitoring, Leak Detection with Audible/Visual Alert |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CH-200P |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| Flow Rate Range | 1–200 mL/min |
| UV Detection Wavelength Range | 200–600 nm |
| Gradient Capability | Binary Gradient |
| Column Compatibility | Flash columns (4–800 g silica/C18), max. sample load: 80 g |
| Collection Modes | Full collection, peak-based collection, manual collection, time-window collection |
| Real-time Fraction Mapping | Color-coded tube assignment per detected peak |
| Purge Function | Integrated air pump module for manual/automated column purging |
| Interface | Touchscreen GUI with transparent fluidic pathway visualization |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH Pro CH-200PII |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| UV Detection Wavelength Range | 200–600 nm |
| Gradient Capability | Binary Gradient |
| Column Compatibility | Normal- and Reversed-Phase Flash Columns (4–800 g), Max Sample Load: 80 g |
| Fraction Collection Modes | Full Collection, Peak-Based Collection, Manual Trigger, Time-Window Collection |
| Real-Time Tube Mapping | Color-Coded Fraction Tube Assignment per Peak |
| Optional Air-Purge Module | Integrated Air Pump for Manual/Automatic Flash Column Purging (CH-200PII-Air Variant) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | CH-200PII |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| UV Detection Wavelength Range | 200–600 nm |
| Gradient Capability | Binary Gradient |
| Column Compatibility | Normal-Phase & Reversed-Phase Flash Columns (4–800 g), Max. Sample Load: 80 g |
| Collection Modes | Full Collection, Peak-Based Collection, Manual Collection, Time-Window Collection |
| Real-Time Fraction Mapping | Color-Coded Tube Assignment per Detected Peak |
| Optional Air-Purge Module | Integrated Air Pump for Manual/Automatic Flash Column Purging (CH-200PII-Air Variant) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MP200 |
| Price Range | USD 14,000–28,000 |
| Application Level | Laboratory-Scale Purification |
| Instrument Type | Medium-Pressure Preparative LC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ≤2% |
| Maximum Operating Pressure | 200 psi |
| Detection Wavelength Range | Not Specified |
| Wavelength Reproducibility | Not Specified |
| Baseline Noise | Not Specified |
| Data Acquisition Frequency | Not Specified |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FLEXA HP 100 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 1–100 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 20–30 MPa |
| Wavelength Range (UV-Vis Detector) | 190–800 nm |
| Wavelength Reproducibility | ±1 nm |
| Baseline Noise (UV-Vis, 254 nm, 1 s) | < ±2.5 × 10⁻⁵ AU |
| Data Acquisition Rate | Up to 20 Hz |
| Detector Options | UV-Vis, ELSD, RI |
| Fraction Collection Modes | Time-based, Peak-triggered, Threshold-based, User-defined Coordinates |
| Communication Interface | RS-232, Optional Ethernet/USB |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FL-H100G |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–100 mL/min |
| Flow Accuracy | ±1 % |
| Maximum Operating Pressure | 20 MPa |
| Brand | Agela |
|---|---|
| Model | FL-H1000G |
| Origin | Tianjin, China |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0–1000 mL/min |
| Flow Accuracy | ±3% |
| Maximum Operating Pressure | 10 MPa |
| Application Level | Laboratory-Scale Purification |
| Configuration | Modular (Pump, UV/Vis Detector, Fraction Collector, Auto-Sampler, Column Switching Valve) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FL-H300G |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0.01–300 mL/min |
| Flow Accuracy | ±2% |
| Maximum Operating Pressure | 15 MPa |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FL-H050G |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0.1–50 mL/min |
| Flow Accuracy | ±1% RSD |
| Maximum Operating Pressure | 30 MPa |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | FLEXA |
| Price Range | USD 14,000 – 28,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–100 mL/min (FLEXA GP100), 1–200 mL/min (FLEXA GP200), 1–30 L/min (FLEXA GP030) |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm (FL-UV2040), 200–800 nm (FL-UV2080/2080B) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | ±1 nm |
| Baseline Noise | ≤3 × 10⁻⁴ AU |
| Data Acquisition Rate | 3 Hz |
| Gradient Composition Accuracy | ±1% |
| Gradient Modes | Binary, Linear, Isocratic, and Custom Profiles |
| Detector Channels | Dual-Wavelength Simultaneous Detection |
| UV Source | Deuterium Lamp (200–400 nm), Tungsten Lamp (400–800 nm) |
| Collection Vessels | 13 mm, 15 mm, 18 mm, 25 mm test tubes, and 100 mL Erlenmeyer flasks |
| Fraction Trigger Modes | Full Collection, Manual Trigger, Threshold-Based Peak Detection |
| Communication Interface | RS-232 |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | FLEXA-MH |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ≤2% |
| Maximum Pressure | 10 MPa |
| Wavelength Range | 200–800 nm (selectable dual-wavelength mode) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75 × 10⁻⁵ AU at 254 nm, TC = 1 s |
| Data Acquisition Rate | Not specified |
| Detection Options | UV-Vis (dual-wavelength), optional ELSD or RI detector |
| Gradient Capability | Binary gradient, supporting linear, isocratic, and custom profiles |
| Column Configuration | Compatible with both reversed-phase and normal-phase chromatography |
| Collection Mode | X/Y-axis programmable fraction collector |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-D-5800P |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–150 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | <1% |
| Maximum Operating Pressure | 40 MPa |
| UV Detection Wavelength Range | 200–800 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-D-5800P |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–150 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | <1% |
| Maximum Operating Pressure | 40 MPa |
| UV-Vis Wavelength Range | 200–800 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HS-D-5800P |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–150 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | <1% |
| Maximum Operating Pressure | 40 MPa |
| UV Wavelength Range | 200–800 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Brand | Agela |
|---|---|
| Model | LC-10F |
| Origin | Tianjin, China |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increment) |
| Max Operating Pressure | ≤ 42 MPa (316L stainless steel pump head) |
| Injection Capacity | Not specified |
| Column Oven Temperature Control | Not specified |
| UV-Vis Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75 × 10⁻⁵ AU (254 nm, time constant = 1 s) |
| Baseline Drift | 1.5 × 10⁻⁴ AU/h (254 nm) |
| Flow Accuracy | ±0.5 % (at 1 mL/min, 10 MPa) |
| Flow Precision | RSD ≤ 0.1 % (at 1 mL/min, 10 MPa) |
| Pressure Pulsation | ≤ 0.5 % (at 1 mL/min, 10 MPa) |
| Detector Light Sources | Deuterium lamp (standard), Tungsten lamp (optional) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic HPLC System |
| Model | LC-10F |
| Instrument Type | Conventional Analytical HPLC |
| Flow Rate Range | 1–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Injection Volume Range | 1–20 µL |
| Wavelength Range | 200–800 nm |
| Data Acquisition Rate | Up to 60 Hz (programmable) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | LC2000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Max Operating Pressure | ≤70 MPa |
| Flow Accuracy | ±1% |
| Injection Volume Range | 0–100 µL (standard) |
| Sample Capacity | Vial tray & 96-well plate compatibility |
| Column Oven Temperature Range | 4–90 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Flow Precision (RSD) | ≤0.075% |
| Pressure Pulsation | ≤0.2 MPa or ≤1% |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Noise (UVD) | ±5 µAU |
| Baseline Drift (UVD) | 1×10⁻⁴ AU/h |
| Flow Cell Volume | 2.5 µL (5 mm path) / 13 µL (10 mm path) |
| Injection Carryover | <0.002% |
| Temperature Stability | ±0.1 °C |
| Column Compatibility | up to 300 mm length |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | Multi-Stage Chromatographic Purification System |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) System |
| Configuration | Integrated Three-Stage Automated Purification Platform |
| Application Focus | Downstream Processing of Biologics, Natural Product Isolation, and Complex Matrix Sample Purification |
| Compliance Framework | Designed to support GLP-compliant workflows and scalable process development |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-2900P II |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 1–100 mL/min |
| Maximum Operating Pressure | 20 MPa |
| UV-Vis Wavelength Range | 200–800 nm |
| Touchscreen Interface | 12-inch Capacitive Display |
| Autosampler Volume Range | 1–20 mL |
| Fraction Collection Modes | Peak-based, Full-run, Manual, Time/UV Window-triggered |
| Compatible Collection Vessels | 15 mm, 18 mm, 25 mm ID tubes and custom containers |
| Pump Configuration | Dual High-Precision Plunger Pumps |
| Gradient Mixing Accuracy | ≤0.5% RSD |
| Column Compatibility | Static HPLC prep columns (10–50 mm ID) |
| Software | Dedicated preparative chromatography control suite with user permission hierarchy and 21 CFR Part 11-compliant audit trail |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | OCTOPUS |
| Application Level | Laboratory-grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤2% |
| Maximum Pressure | 20 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 1 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU |
| Data Acquisition Frequency | Not Specified |
| Gradient Configuration | Binary or Quaternary Pump Options |
| Compatible Detectors | PDA, ELSD, RI |
| Automation Features | Auto-sampler, Column Switcher, Intelligent Fraction Collector with Vial Rack ID Recognition and Solvent/Waste Level Sensing |
| Column Compatibility | Flash cartridges, medium-pressure glass columns, high-pressure stainless-steel columns |
| Brand | Agela |
|---|---|
| Model | ZAM4000 |
| Detection Principle | Evaporative Light Scattering |
| Flow Rate Range | 1–50 mL/min |
| Nebulizing Gas Pressure | 3.5–5 bar |
| Nebulizing Gas Flow Rate | 1.7 L/min |
| Auxiliary Drying Gas Flow Rate | <2 m/min |
| Evaporator Temperature Range | Ambient to 85 °C |
| Light Source | Tungsten Lamp |
| Detector | Photomultiplier Tube (PMT) |
| Output Signal | 0–5 V Analog + RS-232 Digital |
| Power-Saving Mode | Enables independent shutdown of gas, lamp, heater, and PMT |
| Fault Monitoring | Real-time diagnostics for gas flow, heater, lamp, and PMT failure |
| 雾化气流控制 | Integrated electronic pressure controller for nebulizer gas |
| Auxiliary drying gas control | Built-in controller |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Third-Party Service Provider |
| Product Category | Imported Instrumentation |
| Model | Agilent 1100/1200/1360 HPLC 3Q Qualification Package |
| Price Range | USD 11,000–20,500 (FOB) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Operating Pressure | 40 MPa |
| Flow Accuracy | < ±0.1% RSD |
| Injection Volume Range | 1–50 µL |
| Autosampler Tray Capacity | 100 positions |
| Column Oven Temperature Range | 10–60 °C |
| UV-Vis Detector Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Agilent |
|---|---|
| Model | 1120 |
| Type | Compact Liquid Chromatograph (HPLC) |
| Pump Flow Rate Range | 0.001–10.0 mL/min (0.001 mL/min increments) |
| Flow Precision | ≤0.07% RSD |
| Autosampler Injection Volume | 0.1–100 µL (0.1 µL increments) |
| Injection Precision | <0.25% RSD (5–100 µL), <1% RSD (1–5 µL) |
| Sample Capacity | 100 × 2 mL vials or 2 × 40-position half-trays or 15 × 6 mL vials |
| Column Oven Temperature Range | 10 °C above ambient to 60 °C |
| Temperature Stability | ±0.15 °C |
| VWD Wavelength Range | 190–600 nm |
| VWD Noise | ±0.75 × 10⁻⁵ AU |
| Detector Compatibility | RID, FLD, ELSD |
| Software | EZChrom Elite Compact (English/Chinese/Japanese UI), LMD predictive diagnostics |
| Regulatory Support | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compliant operation |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1220 Infinity II Analytical-Scale Purification |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.2–10 mL/min |