Chromatography Instruments
Filter
Showing 121–150 of 1491 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6820 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose GC Analysis |
| Column Oven Temperature Range | 4 °C above ambient to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Temperature Program | Up to 5 ramps/step gradients |
| Number of Heated Zones | 6 |
| Injector Options | Split/Splitless (S/SL), Packed/Purged Injection Port (PPIP) |
| Detector Compatibility | FID, TCD, ECD, NPD (identical specifications to Agilent 6890 series) |
| Data Acquisition Rate | 100 Hz |
| Interface | USB, optional LAN connectivity for Cerity NDS integration |
| Software | Cerity NDS for Chemical QA/QC (localized Chinese UI available) |
| Warranty | 12-month comprehensive coverage with matched Agilent consumables kit |
| Key | Brand: Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Food Industry |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Ionization Detector (FID) |
| Column Compatibility | Capillary columns up to 100 m length, 250 µm ID, 0.2 µm film thickness |
| Regulatory Compliance | Designed for methods compliant with GB/T 22110–2008 and GB/T 22507–2008 |
| Software | Native Agilent ChemStation or OpenLab CDS (FDA 21 CFR Part 11–ready configuration available) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Service Provider |
| Product Category | Imported Instrument |
| Model | 6890/7890/8890 Qualification Services |
| Price Range | USD 10,500–20,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Pharmaceutical Analysis |
| Oven Temperature Range | 0–500 °C |
| Oven Ramp Rate | 0–100 °C/min |
| Oven Cool-down Rate | 0–100 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 psi |
| Inlet Maximum Operating Temperature | 450 °C |
| Inlet Pressure Setting Range | 0–970 psi |
| Inlet Total Flow Setting Range | 0–1200 mL/min |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890N |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N |
| Instrument Type | Gas Chromatograph (GC) |
| Flow Rate Range | 0.001–10.00 mL/min |
| Maximum Operating Pressure | 40 MPa |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | 1–50 µL |
| Oven Temperature Range | 10–60 °C |
| Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890PLUS |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-Down Time | ~6 min (450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 7100 |
| Instrument Category | Capillary Electrochromatography (CEC) |
| Sample Analysis Scope | Organic Compounds |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | 7820 |
| Configuration | Single-Channel, FID-Detected System |
| Regulatory Compliance | Designed to meet ASTM D3606, ISO 10301, and USP <621> chromatographic method requirements |
| Software Platform | OpenLAB CDS (Compatible with 21 CFR Part 11-compliant configurations) |
| Detector Options | Flame Ionization Detector (FID), optional TCD or ECD available |
| Carrier Gas Compatibility | Helium, Hydrogen, Nitrogen |
| Column Compatibility | Capillary and packed columns (0.1–0.53 mm ID, up to 60 m length) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7820A |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-purpose Analytical Chemistry |
| Detector Options | FID, TCD, FPD Plus, NPD, µECD |
| Injector Types | Split/Splitless, Packed Column, Purge-and-Trap, Headspace |
| Valve Configuration | Up to 3 Valves |
| Control Architecture | Full Electronic Pressure Control (EPC) from Injector to Detector |
| Software Interface | Compatible with OpenLab CDS and Third-party Data Systems |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Agilent |
|---|---|
| Origin | USA |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 8 °C to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Time | 999.99 min (maximum runtime) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 psi |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Column Oven Dimensions | 28.0 × 30.5 × 16.5 cm |
| Retention Time Reproducibility | < 0.06% RSD |
| Peak Area Reproducibility | < 2% RSD |
| Power Requirement | 220 V (±10%), 47.5–63 Hz, 1500 W (100 V: 2250 W) |
| Weight | 50 kg |
| Compliance | IEC/EN 61010, UL 61010, CSA C22.2 No. 61010, CISPR 11/EN 55011 Class A, ISO 9001 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7820A VL |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose analysis |
| Control System | Electronic Pressure Control (EPC) at inlet |
| Detector Regulation | Electronic Pressure Regulation (EPR) for FID |
| Included Configuration Options | SSL/EPC inlet + FID/EPR detector |
| Software | OpenLab CDS VL |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | 7890 |
| Configuration | Dual Inlet / Triple Detector (FID, TCD, and Optional Third Detector) |
| EPC Channels | Up to 16 |
| Pressure Control Resolution | 0.001 psi |
| Retention Time Reproducibility | < 0.0008 min (RSD < 0.008%) |
| Peak Area Reproducibility | < 1% RSD |
| Oven Temperature Range | 35–450 °C |
| Oven Ramp Rate | Up to 120 °C/min |
| Column Flow Control Modes | Constant Pressure, Gradient Pressure (3-step), Constant Flow, Gradient Flow (3-step) |
| Data Output | Full-range digital signal (e.g., FID dynamic range: 10⁷) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Specialty Gas Analysis |
| Oven Temperature Range | Ambient + 5 °C to 400 °C |
| Maximum Ramp Rate | 60 °C/min |
| Cooling Rate | ≤9 min (350 °C → 50 °C) |
| Carrier Gas (He) Flow Range | 0–500 mL/min |
| Carrier Gas (He) Pressure Range | 0–500 kPa |
| Injector Max Temp | 400 °C |
| Injector Pressure Setting Range (He) | 0–100 kPa |
| Injector Total Flow Setting Range (He) | 0–500 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Temperature Control Range | Ambient to 450 °C (oven) |
| Ramp Rate | Up to 120 °C/min |
| Cool-down Rate | From 450 °C to 50 °C in <3.5 min |
| Carrier Gas Flow Range | 0–1200 mL/min (He, H₂, N₂) |
| Carrier Gas Pressure Control | 0–100 psi (EPC resolution: 0.001 psi) |
| Inlet Pressure Setting Range | 0–100 psi (split/splitless), 0–150 psi (high-pressure option) |
| Total Inlet Flow Setting Range | 0–1200 mL/min |
| Inlet Operating Temperature | Up to 450 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 450 °C to 50 °C (typical) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Heating/Cooling Rate | Enabled by Low Thermal Mass (LTM) modules for direct, rapid column heating and cooling |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable data systems (when paired with OpenLab CDS or ChemStation software) |
| Brand | Agilent |
|---|---|
| Origin | USA |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 400 °C |
| Oven Ramp Rate | 0.1–120 °C/min |
| Cooling Mechanism | Low Thermal Mass (LTM) module enables rapid column heating and cooling |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | up to 970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | up to 970 kPa |
| Total Injector Flow Setting Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | 8860 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | +8 °C above ambient to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | 300 °C to 50 °C in 5.7 min (at 25 °C ambient) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | Agilent 8860 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Ultra-High-Purity (UHP) Electronic Specialty Gas Analysis |
| Oven Temperature Range | 8 °C above ambient to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | 300 °C → 50 °C in ≤5.7 min (at 25 °C ambient) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Model | Agilent 8860 |
| Detector Type | Pulsed Discharge Helium Ionization Detector (PDHID) |
| Column Oven Temp Range | 8 °C above ambient to 425 °C |
| Max Ramp Rate | 75 °C/min |
| Cooling Rate | 300 °C → 50 °C in ≤5.7 min (at 25 °C ambient) |
| Temperature Resolution | 0.1 °C |
| Max Run Time | 999.99 min |
| PDHID Detection Limit | ≤10 ppb (as CH₄) |
| Linear Dynamic Range | 10⁵ |
| Measurable Impurities | H₂, O₂/Ar, N₂, CH₄, CO, CO₂, C₂H₆ |
| Compliance | GB/T 28726–2012, JJG 700–2016, GB/T 8979–2008, GB/T 4842–2006, GB/T 4844.3–2005, GB/T 3634.2–2011, GB/T 6052–2011 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Agilent 8860 |
| Instrument Type | Laboratory Gas Chromatograph |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Column Oven Dimensions | 28.0 × 30.5 × 16.5 cm |
| Operating Temperature Range | 8 °C above ambient to 425 °C |
| Temperature Setpoint Resolution | 0.1 °C |
| Max Heating Rate | 75 °C/min |
| Cooling Rate | 300 °C → 50 °C in ≤5.7 min (at 25 °C ambient) |
| Max Run Time | 999.99 min |
| Temperature Programming | Up to 20 ramps (including negative ramps) |
| Ambient Temperature Rejection | <0.01 °C per 1 °C ambient change |
| Analog Outputs | Two channels (1 V and 10 V standard) |
| Remote Control | Start/Stop via digital I/O |
| Connectivity | Ethernet (LAN) |
| Flow Selection Valve | BCD-encoded input |
| Operating Environment | 15–35 °C, 5–90% RH (non-condensing) |
| Storage Range | −40 to 70 °C |
| Max Operating Altitude | 4600 m |
| PDHID Detection Limit | ≤10 ppb (as CH₄) |
| Linear Dynamic Range | 10⁵ |
| Measurable Impurities in HBr | H₂, O₂, N₂, CH₄, CO, CO₂, C₂H₆, H₂O, HCl |
| Compliance Standards | GB/T 28726–2012, JJG 700–2016 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8890 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | +4 °C above ambient to 450 °C |
| Maximum Ramp Rate | 120 °C/min (75 °C/min with 120 V power supply) |
| Oven Cool-down | 4.0 min from 450 °C to 50 °C (ambient 22 °C) |
| Detector Options | FID, TCD, SCD, NCD, compatible with single-quadrupole, triple-quadrupole, and Q-TOF GC/MS platforms |
| Retention Time Reproducibility | <0.008% RSD |
| Peak Area Reproducibility | <0.5% RSD |
| Pressure Control Resolution | 0.001 psi |
| Dual-Tower Simultaneous Injection | Yes |
| Dimensions (W × D × H) | 58 cm × 51 cm × 49 cm |
| Microfluidic Flow Control Technology (CFT) | Fully integrated |
| Cryogenic Cooling Options | –80 °C (LN₂), –40 °C (CO₂) |
| Inlet Configurations | Up to 2 inlets + 10 valves |
| Environmental Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | Agilent 8890 PDD |
| Pricing | Available Upon Request |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Column Oven Range | 40 °C above ambient to 450 °C |
| Temperature Stability | < 0.01 °C per 1 °C ambient fluctuation |
| Max Ramp Rate | 120 °C/min |
| Cooling Time | ≤6 min (450 °C → 50 °C at 22 °C ambient) |
| LOD | 5–25 ppb (gas-dependent) |
| Compliance | GB/T 28726-2012, JJG 700-2016, GB/T 8979-2008, GB/T 4842-2006, GB/T 4844.3-2005, GB/T 3634.2-2011, GB/T 6052-2011 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Agilent 8890 |
| Quotation | Upon Request |
| Detector | Dual-Pulse Helium Ionization Detector (PDHID) |
| Column Oven Temp Range | 40 °C above ambient to 450 °C |
| Temp Setpoint Resolution | 1 °C |
| Ramp Rate | 0.1–120 °C/min |
| Temp Stability | <0.01 °C per 1 °C ambient fluctuation |
| Programmable Temperature Steps | 20 ramps / 21 platforms |
| Max Run Time | 999.99 min |
| Cool-down | ≤6 min (450 °C → 50 °C at 22 °C ambient) |
| Detection Limits | 5–10 ppb for H₂, O₂/Ar, N₂, CH₄, CO, CO₂, C₂–C₄ hydrocarbons, SiH₃Cl, Si₂H₆, and other silicon-containing impurities in electronic-grade silane (≥99.9995% purity) |
| Compliance | GB/T 28726–2012, JJG 700–2016, GB/T 15909–2017 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Agilent 8890 |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | 990 GC |
| Detection Limit | 0.5 ppm (on WCOT capillary column) |
| Repeatability | RSD < 0.5% for 1 mol% propane on WCOT column under isothermal and isobaric conditions |
| Carrier Gases | Helium, Hydrogen, Nitrogen, Argon |
| Column Oven Max Temperature | 180 °C |
| Injector Max Temperature | 110 °C |
| TCD Linear Dynamic Range | 10⁵ (0.5 ppm to 5%) |
| TCD Concentration Range | 0.5 ppm to 100% |
| Inlet Pressure Rating | 100 kPa (14.5 psi) |
| Sample Loop | Micro-machined, fixed-volume, non-split |
| Detector Type | Micromachined Dual-Channel Thermal Conductivity Detector (TCD) |
| Maximum Independent Channels | 4 |
| Column Types Supported | WCOT, PLOT, Micro-packed (Hayesep D, Carboxen) |
| Peak Area Reproducibility | < 0.5% RSD |
| Environmental Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CE/MS |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Analysis Scope | Organic Compounds |
| Compatible Mass Spectrometers | Agilent 6100 (Single Quadrupole), 6200 (TOF), 6400 (Triple Quadrupole), 6500 (Q-TOF), ICP-MS, ICP-MS/MS |
| Ionization Sources | ESI (Standard & JetStream), APCI, APP |
| Spray Interface | Grounded-potential, Plug-and-Play Electrospray Interface with Integrated Desolvation |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Femto Pulse |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Application | Organic Analysis (Nucleic Acids) |
| Voltage | 100–240 VAC, 47–63 Hz |
| Power Consumption | 150 VA |
| Operating Temperature | 19–25 °C |
| Relative Humidity | 20–80 % |
| Dimensions (W × D × H) | 36 cm × 51 cm × 61 cm |
| Sample Throughput | Up to 288 samples per unattended run (3 × 96-well plates) |
| Sample Volume | 2 µL per injection |
| Detection Sensitivity | 50 fg/µL for nucleic acids |
| Separation Range | Up to 165 kb DNA fragments and smears |
| Run Time | ~90 minutes for full-range HMW DNA analysis |
| Reagent Kit Type | Quantitative Analysis Kits |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | Fragment Analyzer 5200 |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Type | Organic Analysis (Nucleic Acids) |
| Voltage | 100–240 VAC, 47–63 Hz |
| Power Consumption | 150 VA |
| Operating Temperature | 19–25 °C |
| Relative Humidity | 20–80 % |
| Dimensions (W × D × H) | 36 cm × 51 cm × 61 cm |
| Weight | 38.5 kg |
| Throughput | 12 samples per run |
| Capillary Array Options | Three lengths for resolution/speed optimization |
| Resolution | ≤3 bp for fragments <300 bp |
| Quality Metrics | RNA Quality Number (RQN), Genomic DNA Quality Number (GQN) |
| Automation Capacity | Up to 288 samples unattended (with three 96-well plates) |
| Reagent Stability | Room-temperature stable kits |
| Compliance Support | IQ/OQ documentation available for GMP/GLP environments |