| Brand | Waters |
|---|---|
| Origin | USA |
| Model | E2695 |
| Instrument Type | Fast Liquid Chromatography System |
| Maximum Pressure | 34.5 MPa |
| Sample Capacity | 120 × 2 mL vials |
| Injection Volume Range | 0.1–100 µL |
| Flow Rate Range | 0.001–10.000 mL/min |
| Column Oven Temperature Range | Ambient +5 °C to 85 °C |
| UV/Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | Up to 80 Hz |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Investigator SFC System |
| Application Level | Laboratory Grade |
| Instrument Type | Semi-Preparative Supercritical Fluid Chromatography System |
| Flow Rate Range | Up to 15 mL/min |
| Column Capacity | Up to 10 analytical columns or 6 preparative columns |
| Integrated Autosampler | Waters Alias |
| Software Platform | SuperChrom |
| Optional Detectors | 2998 Photodiode Array (PDA) Detector, 2424 Evaporative Light Scattering (ELS) Detector |
| Dimensions (H×L×W) | 92 cm × 98 cm × 68 cm |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | LC-2695 |
| Instrument Type | High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | ~50 µL |
| Column Oven Temperature Range | Ambient +10 °C to 60 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | PATROL UPLC |
| Instrument Type | Real-time In-line/At-line UPLC-based PAT System |
| Regulatory Alignment | Designed for FDA QbD and ICH Guidelines |
| Deployment Mode | Integrated Process Analytical Technology (PAT) Platform |
| Operational Architecture | Fully Automated, 24/7 Unattended Operation |
| Diagnostics | On-board Self-Diagnostics with Remote Monitoring Capability |
| Connectivity | Ethernet/IP-enabled for Distributed Control System (DCS) and Manufacturing Execution System (MES) Integration |
| Software Compliance | Supports 21 CFR Part 11 Audit Trail, Electronic Signatures, and GLP/GMP Data Integrity Requirements |
| Sample Introduction | Configurable for At-line Flow-Through Cells or Direct In-line Probes (with Optional Valving & Filtration Modules) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep 100q SFC |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative SFC System |
| Flow Rate Range | Up to 100 mL/min |
| Mobile Phase | CO₂-based supercritical fluid (co-solvent compatible) |
| Fraction Collection | Automated open-loop collection with UV- or MS-triggered modes |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Separation Mode | Chiral and achiral preparative separations |
| Sample Scale | Milligram- to gram-scale purification |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep 150 |
| Application Level | Laboratory-grade |
| Instrument Type | High-pressure preparative LC |
| Pump Configuration | Binary or Quaternary (low-pressure solvent selection or high-pressure gradient mixing up to 150 mL/min) |
| Detector Options | 2489 UV/Vis or 2998 Photodiode Array (PDA) |
| Column Compatibility | Up to 50 mm internal diameter |
| Sample Load Range | Milligram- to gram-scale purification |
| Software | ChromScope™ for method development, fraction simulation, and GLP-compliant data handling |
| Compliance | Designed to support 21 CFR Part 11–ready workflows with audit trail and electronic signature capability (when configured with appropriate IT infrastructure) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prep SFC 150 AP System |
| Instrument Type | Preparative |
| Detector Types | None |
| Maximum Pressure | Not Specified |
| Flow Rate Range | Not Specified |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Prep SFC 150 Mgm |
| Type | Preparative |
| Maximum CO₂ Flow Rate | 150 mL/min |
| Modifier Flow Range | Up to 150 mL/min |
| Fraction Collection Positions | 6 × 2 L |
| Operating System | Windows 10 |
| Control Software | Waters ChromScope 2.0 SFC |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Preparative Supercritical Fluid Chromatography (SFC) System |
| Model Variants | 80, 200, 350 |
| Application Level | Laboratory-Scale Purification |
| Regulatory Context | Designed for GLP-compliant workflows and compatible with FDA 21 CFR Part 11–enabled software environments |
| Compliance Framework | Supports ASTM D7894–21 (Standard Guide for SFC Method Development), ISO 17025–2017 (Testing Laboratory Competence), and USP <621> Chromatography guidelines |
| Software Platform | SuperChrom v3.x (with audit trail, electronic signatures, and method versioning) |
| Detection | UV-Vis absorbance detection (dual-wavelength capability) |
| Fraction Collection | Automated, timed or peak-triggered, with solvent compatibility up to 100% CO₂-expanded liquids and polar modifiers (e.g., methanol, ethanol, isopropanol) |
| Back Pressure Control | Active Automatic Back Pressure Regulator (ABPR) with ±0.2 bar pressure stability |
| Solvent Delivery | Dual-pump architecture — primary CO₂ pump (supercritical phase delivery) and auxiliary modifier pump (liquid-phase co-solvent gradient) |
| System Architecture | Modular, rack-mounted configuration with integrated safety interlocks, CO₂ phase monitoring, and real-time density compensation |
| Brand | Wayeal |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model Series | GC6000 |
| Temperature Control Range | +4 °C above ambient to 450 °C |
| Maximum Ramp Rate | 60 °C/min |
| Carrier Gas Flow Control | Electronic Flow Control (EFC) |
| Injector Maximum Operating Temperature | 400 °C |
| Detector Options | FID6000 (standard), ECD (optional) |
| Autosampler Compatibility | ALS6000 (optional) |
| Air Purification System | Wayeal-built (optional) |
| MS Interface | 预留接口 (MS coupling port available upon request) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC6100 |
| Application Scope | General-Purpose |
| Control Architecture | Dual-Core Mainboard (Quad-Core Application Processor + Dual-Core Co-Processor) |
| Temperature Control | PID with Auto-Tuning & Environmental Compensation |
| EPC System | High-Stability Electronic Pressure Control |
| Detectors Supported | FID (1000 Hz Sampling Rate, 0.5 ms Minimum Peak Width), ECD (Low-Radiation Microcell), MS (Integrated with WAYEAL Mass Spectrometer) |
| Software Platform | SmartLab CDS Workstation with H.B.C-ApexFinder & SmartPeak Algorithms |
| Connectivity | Web-Based UI, Touchscreen (10.1" Capacitive), Remote Access via Browser |
| Compliance Features | Audit Trail, User Permission Levels, Electronic Signatures (FDA 21 CFR Part 11 Ready), GLP/GMP Data Integrity Support |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | IC6000 Plus |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | Universal Anion/Cation Analysis |
| Maximum Pump Pressure | 35 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 21 MPa |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | IC6200 Series |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Ion Analysis |
| Maximum Pump Pressure | 35 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Eluent Flow Rate Range | 0.001–10.000 mL/min |
| Max Operating Pressure | 35 MPa (main unit) / 21 MPa (Eluent Generator) |
| Temperature Control Range | 4–65 °C |
| Temperature Reproducibility | ±0.005 °C |
| Eluent Concentration Range | 0–100 mmol/L (KOH) or 0–15 mmol/L (K₂CO₃) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Model | IC6500 |
| Pump Pressure Rating | 42 MPa |
| Operating Temperature Range | 5 °C to 70 °C |
| Flow Path Material | Full PEEK |
| Detector Configuration | Dual Conductivity Detector |
| Eluent Generation | Integrated On-Line Electrolytic Eluent Generator |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | IC6600 Series |
| Instrument Type | Laboratory |
| Application Scope | General-Purpose |
| Pump Maximum Pressure | 35 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Eluent Flow Rate Range | 0.001–10.000 mL/min |
| Max Operating Pressure | 35 MPa (main unit) / 21 MPa (eluent generator) |
| Operating Temperature Range | 4–65 °C |
| Temperature Reproducibility | ±0.005 °C |
| Eluent Concentration Range | 0–100 mmol/L (KOH) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LC3200S Series |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Maximum Operating Pressure | 45 MPa |
| Wavelength Range (UV/Vis Detector) | 188–900 nm |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LC3400 |
| Instrument Type | Ultra-Fast Liquid Chromatograph |
| Maximum Operating Pressure | 75 MPa |
| Application Scope | General-Purpose HPLC/UHPLC Analysis |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | LC3500 Plus |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-purpose analytical chromatography |
| Compliance | Designed for GLP/GMP-aligned laboratory environments |
| Software Compatibility | Native support for WAYEAL ChromNav CDS (Chromatography Data System), compliant with FDA 21 CFR Part 11 audit trail requirements |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LC3600 Series |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Instrumentation |
| Wavelength Range | 188–900 nm |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | WHALE HP |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 300–1000 mL/min |
| Flow Accuracy | ±3% |
| Pressure Rating | 10 MPa (pump max: 5 MPa) |
| UV-Vis Detection | PDA with 200–800 nm scanning range |
| Fraction Collection | 6-position valve-based collector + 1 solvent recovery channel |
| Column Compatibility | DAC columns (100–200 mm i.d.) or Flash cartridges (800–5000 g) |
| Sample Loading | Integrated liquid loading module, up to 1000 mL/min |
| Data Acquisition | Real-time spectral scanning and peak-triggered collection |
| Solvent Recovery Mode | Spectral purity assessment-enabled solvent reuse |
| Collection Modes | Full collection, peak collection, manual trigger, time-window collection |
| Brand | whYOKO |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Preparative TLC Coater |
| Operation Mode | Fully Automatic |
| Wavelength Range | 200–700 nm |
| Wavelength Accuracy | ±1 nm |
| Coating Thickness Adjustment | 0.05–2.0 mm |
| Non-Parallelism Tolerance | ≤0.04 mm |
| Throughput | 210 plates (200 × 200 mm) per 10 minutes |
| Traverse Speed | 4.2 m/min |
| Power Consumption | 90 W (BF-111) |
| Dimensions (L×W×H) | 340 × 130 × 190 mm |
| Plate Compatibility | 100 × 100 mm to 200 × 200 mm |
| Coating Frame Material | Anodized Aluminum with Powder Coating |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | whYOKO |
|---|---|
| Origin | Hubei, China |
| Model | BL+YS |
| Instrument Type | Thin-Layer Chromatography (TLC) Densitometer with Bio-Luminescence Detection and Integrated Immersion Derivatization System |
| Detector Principle | Bioluminescent Inhibition Assay (BIA) |
| Maximum Plate Size | 200 mm × 200 mm |
| Scanning Modes | Linear scan, Multi-channel simultaneous acquisition |
| Detection Sensor | High-quantum-efficiency CCD with cooled imaging architecture |
| Derivatization Method | Vertical immersion (non-aerosol, contact-based) |
| Immersion Speed | 40 mm/s (adjustable vertical actuation) |
| Immersion Duration | 1–60 s (programmable in 0.1 s increments) |
| Plate Height Compatibility | 100 mm and 200 mm formats |
| Pre-wash Function | Supported via immersion cylinder |
| Derivatization Chamber | Sintered stainless-steel immersion tank (200 mm × 200 mm × 50 mm depth) |
| Software Platform | whYOKO TLC-Densitometry Suite v3.x (Windows 10/11 compatible) |
| Quantitation Algorithms | Normalization, internal standard, external standard |
| Data Storage | Unlimited spectral archives with metadata tagging (ISO/IEC 17025-compliant file structure) |
| Regulatory Compliance | Supports audit trail, user access levels, electronic signature (FDA 21 CFR Part 11 ready mode) |
| Brand | whYOKO |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TLC Starter Kit |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Instrument Type | Preparative Thin Layer Chromatography System |
| Operation Mode | Fully Automated Workflow Support (Modular Automation) |
| Key Components | Manual/semi-automated plate coater (TF-III/BF-III), programmable motorized sample applicator (BD-I/BD-II/AD), dual-chamber developing tanks (10×20 cm ×2, 20×20 cm ×1–2), multi-mode visualization system (UV 254/365 nm, iodine chamber, derivatization unit, digital imaging) |
| Brand | whYOKO |
|---|---|
| Origin | Hubei, China |
| Model | YOKO-BA |
| Wavelengths | 254 nm & 365 nm (dual-band) |
| Lamp Configuration | Two independent UV lamps (one 254 nm, one 365 nm) |
| Filter Dimensions | 50 mm × 200 mm |
| Filter Transmission | ≥68% at 254 nm, ≥86% at 365 nm |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Power Consumption | 12 W |
| Operating Mode | Manual |
| Enclosure Dimensions | 340 mm (L) × 130 mm (W) × 190 mm (H) |
| Sample Viewing Area | 200 mm × 200 mm |
| Maximum Sample Thickness | 5 mm |
| Compliance | CE-marked design principles |
| Brand | whYOKO |
|---|---|
| Origin | Hubei, China |
| Model | yoko-BF-111 |
| Type | TLC Plate Coating Device |
| Operation Mode | Motorized (non-manual hand-crank) |
| Coating Width Options | 100 mm or 200 mm |
| Adjustable Coating Thickness | 0.05–2.0 mm |
| Thickness Uniformity (Non-Parallelism) | ≤ 0.04 mm |
| Throughput | Up to 210 pcs of 200 × 200 mm plates per 10 minutes (BF-I/BF-II mode) |
| Motorized Traverse Speed | 4.2 m/min |
| Power Consumption | 90 W (BF-I/BF-II), 40 W (BF-III variant) |
| Dimensions (L×W×H) | 340 × 130 × 190 mm |
| Frame Material | Anodized Aluminum with Epoxy Coating |
| Compliance | Designed for GLP-compliant thin-layer chromatography (TLC) plate preparation in regulated and research laboratories |
| Brand | WhYOKO |
|---|---|
| Origin | Hubei, China |
| Model | YOkO-CA (Type I), YOkO-YJ (Type II) |
| Dimensions | Type I – 10 × 20 cm capacity (holds 10 pcs of 10×20 cm plates, or 20 pcs of 10×10 cm plates, or 40 pcs of 5×10 cm plates) |
| Material | Anodized aluminum frame with high-performance engineering plastic coating |
| Compliance | Designed for USP <621>, EP 2.2.27, and ISO/IEC 17025-compliant TLC workflows |
| Packaging | Each organic solvent-resistant storage box accommodates two Type I cabinets |
| Brand | whYOKO |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | YOKO-LB |
| Instrument Category | TLC Auxiliary Equipment |
| Material | Full Stainless Steel (AISI 304) |
| Capacity | ≥20 Glass Plates per Load |
| Configuration | Collapsible, Multi-Orientation (Upright Drying / Sideways Storage / Vertical Spray Support) |
| Compliance | Designed for ISO/IEC 17025-compliant TLC workflows |
| Brand | whYOKO |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | YOKO-QB |
| Instrument Category | TLC Accessories & Manual Workflow System |
| Operation Mode | Manual |
| Pricing | Upon Request |
| Brand | whYOKO |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | YOKO-TD |
| Instrument Category | Thin-Layer Sample Applicator |
| Operation Mode | Fully Automatic |
| Wavelength Accuracy | < ±1.0% |
| Wavelength Repeatability | < ±1.5% |
| Sample Platform Dimensions | 200 × 200 mm TLC Plate |
| Heating Range | 35–200 °C |
| Heating Power | 600 W |
| Strip Length Range | 0–180 mm |
| Air Pressure Control | 0–0.12 MPa |
| Gas Flow Rate | 0.1–2.0 L/min |
| Power Supply | 220 V ±10%, 50–60 Hz, 630 W |
| Dimensions (L×W×H) | 450 × 390 × 290 mm |
| Weight | 16 kg |
| Included Syringes | 10 µL & 50 µL stainless-steel flat-tipped microsyringes |
| Optional Syringes | 25 µL, 100 µL |
| Sample Delivery Method | Non-contact pneumatic spray dispensing |
| Spot/Strip Precision | < ±1.0% (accuracy), < ±1.5% (repeatability) |
| Brand | whYOKO |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YOKO-TF |
| Instrument Category | TLC Ancillary Equipment |
| Operation Mode | Manual |
| Coating Width Options | 10 cm (TF-I), 20 cm (TF-II), Dual 10/20 cm (TF-III) |
| Adjustable Layer Thickness | 0.02–2 mm |
| Frame Material | Anodized Aluminum with Epoxy Coating |