Chromatography Instruments
Filter
Showing 1351–1380 of 1564 results
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Integrion |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Flow Rate Range | 0–22.4 mL/min |
| Eluent Generation Concentration Range | 0.1–100 mM (dependent on eluent chemistry) |
| Maximum Operating Pressure | 5000 psi |
| Temperature Reproducibility | ±0.2 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | ISQ 7610 Single Quadrupole GC-MS |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TRACE 1300 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRACE 1300 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Pricing Range | USD 65,000 – 130,000 (FOB US Port) |
| Module Architecture | Plug-and-Play, User-Replaceable Inlet & Detector Modules |
| Compliance | Designed to support GLP/GMP workflows and 21 CFR Part 11–compliant data integrity requirements |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TRACE 1300 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Chemistry |
| Module Architecture | Plug-and-Play, User-Replaceable Inlet and Detector Modules |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TRACE 1300E |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 125 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Inlet Maximum Operating Temperature | Not specified (standard SSL inlet rated to 450 °C) |
| Inlet Pressure Setting Range | 0–1000 kPa |
| Inlet Total Flow Setting Range | 0–1200 mL/min |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | TRACE 1300E |
| Price Range | USD 135,000 – 205,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Fields | Chemical Analysis, Petrochemical Analysis, Environmental Testing, Food & Flavor Analysis, Pharmaceutical QC |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TRACE 1300E |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 125 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Inlet Maximum Operating Temperature | Not Specified (Configurable per Inlet Type) |
| Inlet Pressure Setting Range | 0–1000 kPa |
| Inlet Total Flow Setting Range | 0–1200 mL/min |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TRACE 1310 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | +3 °C to 450 °C |
| Injector Maximum Operating Temperature | 450 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TRACE 1600 Series |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | TRACE™ 1600 Series GC |
| Pricing | Available upon Request |
| Column Oven Cooling Time | ≤4 min (450°C → 50°C) |
| Heating Rate | Up to 90°C/min |
| Temperature Range | Ambient +3°C to 450°C (optional sub-ambient operation) |
| Power Supply | 120 V |
| Compliance | Machinery Directive 2006/42/EC, Low Voltage Directive 2006/95/EC, EMC Directive 2004/108/EC |
| Dimensions (L × W × H) | 45 × 44 × 67 cm |
| Inlet Options | SSL, PTV, SSL-BKF, PTV-BKF, COC, GSV (up to 2) |
| Detector Options | FID, TCD, ECD, NPD, FPD, PDD, MS-compatible (up to 2) |
| iConnect™ Module Architecture | Tool-free inlet/detector swapping, column locking, offline maintenance capability |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Series | TSP P1500 (Quaternary Pump), UV1000 (Variable Wavelength Detector), AS3000 (Autosampler) |
| Compliance | CE, UL, RoHS |
| Operating Pressure Range | Up to 400 bar |
| Flow Rate Range | 0.001–10.000 mL/min |
| Wavelength Range (UV1000) | 190–700 nm |
| Detection Limit (UV1000) | < 5 × 10⁻⁹ g/mL (caffeine, 254 nm) |
| Injection Volume Range (AS3000) | 0.1–100 µL |
| Precision (RSD) | ≤ 0.3% for retention time, ≤ 0.5% for peak area |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Series | P4000, AS 3000, UV 1000 |
| Compliance | CE, UL, RoHS |
| Flow Rate Range | 0.001–10.000 mL/min |
| Pressure Rating | Up to 400 bar |
| Gradient Accuracy | ≤0.2% RSD |
| Pulse Dampening | Active electronic compensation |
| Solvent Compatibility | HPLC-grade aqueous/organic solvents (including THF, DCM, DMF) |
| Communication Interface | RS-232, CAN bus, optional Ethernet (via TSP Control Hub) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish Charged Aerosol Detector P Series |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) Detector |
| Application Scope | Universal Detection |
| Flow Rate Range | 0.01–2.0 mL/min |
| Temperature Control Range | 10–100 °C |
| Data Acquisition Frequency | 200 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Vanquish Core |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Maximum Operating Pressure | 700 bar |
| Column Oven Temperature Range | 5 °C to 85 °C |
| Data Acquisition Rate | 125 Hz |
| System Configuration Options | Quaternary, Binary, and Isocratic Configurations |
| Brand | Thermo Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vanquish Core |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Launch Date | March 2020 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish Flex Binary UHPLC System |
| Price Range | USD 65,000 – 130,000 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Maximum Pressure | 1000 bar (15,000 psi) |
| Flow Rate Range | 0.001–8.0 mL/min |
| Solvent Channels | 6 |
| Injector Capacity | 208 injections (single vial) |
| Column Oven Temperature Range | 5–120°C (dual-mode: static air + forced-air circulation) |
| Detection Options | Diode Array (DAD), Fluorescence (FLR), Electrospray Ionization (ESI) Charged Aerosol Detection (CAD), and MS-coupling ready |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Vanquish™ Core HPLC System |
| Pricing | Available Upon Request |
| Pump Pressure | 700 bar (10,000 psi) |
| Flow Rate Range | Up to 10 mL/min |
| Flow Accuracy | ±0.1% |
| Gradient Delay Volume | Adjustable |
| Solvent Channels | Isocratic (1), Quaternary (4), Binary (6) |
| Column Temperature Range | 5–85 °C (0.1 °C increment |
| Sample Tray Temperature | 4–40 °C (0.1 °C increment, with Vanquish Core Split Injector CT) |
| Detector Data Acquisition Rate | Up to 125 Hz |
| Detection Options | UV-Vis DAD, Fluorescence, CAD, MS-compatible interfaces |
| Software Platform | Chromeleon™ CDS (v7.3 or later) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail, ASTM D7922, ISO 17025 support |
| Connection System | Viper™ fingertight fittings (tool-free, leak-free) |
| Brand | Thermo Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Vanquish |
| Instrument Type | Ultra-High Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 150 MPa |
| Sample Tray Capacity | 8832 positions |
| Injection Volume Range | 0.01–100 µL |
| Column Oven Temperature Range | 5–120 °C |
| Data Acquisition Rate | 200 Hz |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | GC9800N |
| Instrument Category | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry Dedicated |
| Oven Temperature Range | Ambient + 8 °C to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 450 °C → 50 °C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 800 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Column Oven Temp Accuracy | ±0.1 °C |
| Programmed Ramp Rate (Standard) | 0.1–35 °C/min |
| Vaporizer & Detector Temp Range | Ambient + 6 °C to 350 °C |
| Pyrolyzer Temp Range | 100–800 °C |
| Transfer Line Outlet Temp Range | Ambient + 6 °C to 300 °C |
| FID Detection Limit | ≤1 × 10⁻¹¹ g/s (n-C₁₆) |
| Baseline Drift | ≤30 µV/15 min |
| Noise | ≤10 µV |
| Solid Sample Mass Range | 0.01–1.0 mg |
| Brand | TIMEPOWER |
|---|---|
| Model | TP-101 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry-Specific |
| Oven Temperature Range | Ambient to 200 °C (Column Oven), up to 300 °C (Detector & Methanizer) |
| Temperature Control Accuracy | ≤ ±0.3 °C |
| Temperature Stability (Baseline Drift) | TCD ≤ 0.2 mV/30 min |
| Baseline Noise | TCD ≤ 0.1 mV |
| Sensitivity | TCD ≥ 1000 mV·mL/mg (benzene) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (N₂ or other compatible gases) |
| Methanizer Temperature | 380 °C |
| Detection Limits (ppm) | CH₄ 0.1 |
| Warm-up Time to Operational Stability | < 90 min |
| Display Resolution | 0.1 °C |
| Dimensions (W×D×H) | 620 × 445 × 485 mm |
| Weight | 31.8 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Oven Temperature Range | Ambient to 300 °C |
| Temperature Ramp Rate Accuracy | ≤ ±0.3 °C |
| Cooling Rate | Not specified (fan-cooled oven) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (7-programmable segments) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (7-programmable segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Column Oven Stabilization Time | < 1.5 h |
| Temperature Display Resolution | 0.1 °C |
| Temperature Control Accuracy | ≤ ±0.3 °C |
| Baseline Noise | TCD ≤ 0.1 mV |
| Baseline Drift | TCD ≤ 0.2 mV / 30 min |
| TCD Sensitivity | ≥ 1000 mV·mL/mg (benzene) |
| FID Detection Limit | ≤ 5 × 10⁻¹² g/s |
| Detector (FID) Operating Range | Ambient to 300 °C |
| Methanizer Temperature | 380 °C |
| Over-Temperature Protection | Independent thermal cutoff with audible alarm and power interlock |
| Detection Limits (ppm) | CH₄ 0.1, CO 1, CO₂ 1, H₂ 5, C₂H₂ 0.1, C₂H₄ 0.1, C₂H₆ 0.1 |
| Dimensions (W × D × H) | 620 × 445 × 485 mm |
| Net Weight | 31.8 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TP/101 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 8 °C above ambient to 450 °C |
| Oven Ramp Rate | 16-step programmable, 0.1–39 °C/min (standard configuration) |
| Oven Cooling Rate | ~18 min from 39 °C to 0.1 °C (ultra-fast cooling mode) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (7 program segments) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (7 program segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TP101 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Power Industry-Specific |
| Temperature Control Range | 8 °C above ambient to 450 °C (1 °C increment, ±0.1 °C accuracy) |
| Oven Ramp Rate | 0.1–39 °C/min (standard) |
| Oven Cool-Down Rate | 0.1–39 °C/min (standard) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-8000 |
| Flow Rate Range | 0.01–10.000 mL/min (0.001 mL/min increment) |
| Maximum Operating Pressure | 10,500 PSI (72 MPa) at 0–2 mL/min |
| Flow Accuracy | ≤0.06% RSD |
| Autosampler Capacity | ≥108 positions (1.5 mL vials) |
| Injection Volume Range | 20–100 µL |
| Column Oven Temperature Range | Ambient +5 °C to 85 °C |
| UV-Vis Detector Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | LC-8000 |
| Pressure Range | Up to 70 MPa |
| Column Compatibility | Supports 2 µm particle-packed columns |
| Flow Pulsation | <10 psi (PPRC technology) |
| Column Oven Capacity | Accommodates up to six 250 mm columns simultaneously |
| Temperature Uniformity | ±0.1 °C (forced-air circulation + high-precision PID control) |
| Autosampler Wash | Dual-needle displacement cleaning mechanism |
| Data Acquisition Rate | Up to 100 Hz |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP, GMP |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | SA-50 |
| Instrument Type | Ultra-High Performance Liquid Chromatography–Atomic Fluorescence Spectrometry System |
| Application Scope | Elemental Speciation Analysis |
| Configuration | Modular, Integrated LC Pump(s), Dual-Column Oven, Column Switching Valve, UV Photochemical Reactor with Auto-Activation, Four-Channel Peristaltic Pump, LED Status Indicators, Optional Autosampler (96-/120-position) |
| Software | Unified Control Platform for Total Element and Speciation Quantification, Method Management, Hybrid Sequence Scheduling, Real-Time Instrument Monitoring, System Self-Diagnosis, Customizable Reporting Templates |
| Compliance Framework | Designed to support GLP/GMP-aligned workflows |
| Brand | Tongtian |
|---|---|
| Model | C500 |
| Instrument Type | Medium-Pressure Preparative LC System |
| Flow Rate Range | 0.1–50.0 mL/min |
| Flow Accuracy | ≤±1% |
| Flow RSD | ≤1% |
| Operating Pressure Range | 0.1–8.0 MPa |
| Pressure Accuracy | ≤0.05 MPa |
| Pressure Pulsation | ≤0.1 MPa |
| UV Detector Wavelength Range | 195–700 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Precision | ±0.1 nm |
| Spectral Bandwidth | ≤8.0 nm (at 250 nm, FWHM) |
| Linear Range | 3.0 AU |
| Baseline Noise | <±2.0×10⁻⁵ AU |
| Baseline Drift | <2.0×10⁻⁴ AU/h |
| Flow Cell Path Length | 4.5 mm |
| Flow Cell Volume | 10 µL (standard) |
| Sample Loop Options | 2 mL, 5 mL, 10 mL, 20 mL |
| Gradient Capability | Dual-pump isocratic/gradient elution |
| Valve Rating | 69 bar (V541) or equivalent preparative-grade injection valve |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | C500 |
| Instrument Type | Medium-Pressure Preparative HPLC System |
| Flow Rate Range | 0.1–50.0 mL/min |
| Flow Accuracy | ≤±1% |
| Flow RSD | ≤1% |
| Operating Pressure Range | 0.1–8.0 MPa |
| Pressure Accuracy | ±0.05 MPa |
| Pressure Pulsation | 0.1 MPa |
| UV Detector Wavelength Range | 195–700 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Precision | ±0.1 nm |
| Spectral Bandwidth | ≤8.0 nm (at 250 nm, FWHM) |
| Linear Range | 3.0 AU |
| Baseline Noise | <±2.0×10⁻⁵ AU |
| Baseline Drift | <2.0×10⁻⁴ AU/h |
| Flow Cell Path Length | 4.5 mm |
| Flow Cell Volume | 10 µL (standard) |
| Gradient Pump | Grad50 dual-piston constant-flow pump |
| Injection Valve | V541 medium-pressure valve (69 bar rating) or Rheodyne 3725-038 preparative valve |
| Column Interface | Convertible stainless-steel column adapter (316L) |
| Software | Dedicated chromatography workstation with method storage, real-time monitoring, and peak integration |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | C2001 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative LC System |
| Flow Rate Range | 0.1–10.0 mL/min |
| Flow Accuracy | ≤±1.5% |
| Flow Precision (RSD) | ≤1% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | 1 × 10⁻⁵ AU |
| Data Acquisition Frequency | 20 Hz |