Cleaning & Disinfection Equipment
Filter
Showing 31–60 of 1188 results
| Brand | Alphavita |
|---|---|
| Model | MVS-84 |
| Chamber Volume | 83 L |
| External Dimensions (W×D×H) | 600 × 620 × 1005 mm |
| Internal Dimensions (Ø × H) | Ø370 × 795 mm |
| Net Weight | 100 kg |
| Power Rating | 3100 W |
| Construction Material | S30408-2B stainless steel (3 mm thickness) |
| Compliance | YY/T 1007–2018, GB 150, GB/T 24511–2017 |
| Safety Features | Dual dry-run protection, overcurrent protection, earth leakage protection, quadruple mechanical/electrical interlock, spring-loaded safety valve, chamber overpressure alarm |
| Operating Altitude | Up to 4000 m ASL |
| Power Interface | 16 A standard plug |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | AC XXXL |
| Automation Level | Fully Automatic |
| Cleanliness Level | ppt-level residue |
| Cycle Time | < 8 hours |
| Material Compatibility | PTFE/PFA-wetted path, PP chassis |
| Max Capacity | 252 digestion tubes per full cycle (3 × 84-tube channels) |
| Safety Interlocks | Temperature, pressure, liquid level, pH monitoring |
| Brand | Amerlab |
|---|---|
| Model | AC360 |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Automation Level | Fully Automated |
| Cleanliness Level | ppt-level residue removal |
| Cycle Time | < 8 hours |
| Construction Materials | Full PTFE/PFA fluid path, PP chassis |
| Safety Features | Multi-point interlocks (temperature, pressure, liquid level, pH) |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AC360 Manual |
| Price Range | USD 1,400 – 14,000 |
| Operation Mode | Semi-Automatic |
| Cleanliness Level | ppb–ppt |
| Cycle Time | 1–4 hours |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AC360 Semi-Automatic |
| Price Range | USD 14,000–21,000 (FOB) |
| Operation Mode | Semi-Automatic |
| Cleanliness Level | ppt-level trace contamination removal |
| Cycle Time | 1–4 hours |
| Brand | Amerlab |
|---|---|
| Model | AC360M |
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Automation Level | Fully Automatic |
| Detection Limit | ppt-level cleanliness |
| Cycle Time | < 8 hours |
| Construction Materials | Full PTFE/PFA fluid path, PP chassis |
| Safety Interlocks | Temperature, pressure, liquid level, and pH monitoring |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AC480 |
| Automation Level | Fully Automatic |
| Cleaning Sensitivity | ppt-level residue control |
| Cycle Time | 30 min acid vapor wash |
| Brand | ANDES |
|---|---|
| Origin | Japan |
| Model | BF-H201AC |
| Disinfection Principle | UV-activated Titanium Dioxide (Anatase-phase, Columnar Crystal Structure) Photocatalysis |
| Airflow | 3.3 m³/min (Cross-flow Fan, 50/60 Hz) |
| Noise Level | ≤48 dB(A) at 1 m |
| Power Consumption | 93 W |
| Dimensions (W×H×D) | 617 × 510 × 152 mm |
| Application Scope | Medical Facilities, Laboratories, Cleanrooms, Pharmaceutical QA/QC Areas, Food Processing Environments |
| Regulatory Status | Compliant with China NMPA (ex-SFDA) Class II Medical Device Requirements for Air Disinfection Devices |
| Sterilization Mode | Non-thermal, Oxidative Decomposition (No Ozone Generation) |
| Filtration Stages | Pre-filter + UV-activated Columnar TiO₂ Photocatalytic Panel + Negative Ion Emission Module |
| Maintenance Interval | Photocatalytic Panel & UV Lamp: ~12 months under continuous operation in ISO Class 8 (100,000) clean air environments |
| Brand | Aoteseins |
|---|---|
| Origin | Tianjin, China |
| Model | AS8800BT |
| Capacity | 800 L |
| Ultrasonic Frequency | 28 kHz |
| Total Ultrasonic Power | 8000 W (adjustable) |
| Heating Range | Ambient to 80 °C (adjustable) |
| Timer Range | 1–999 min (adjustable) |
| Sound-Dampening Lid | Included |
| Auto Fill/Drain System | Integrated |
| Power Supply | 380 V AC, 50 Hz, 3-phase 4-wire with dedicated grounding |
| Dimensions (W×L×H) | 1618 × 970 × 1200 mm |
| Tank Internal Dimensions (W×L×D) | 1100 × 800 × 820 mm |
| Max. Load per Trolley | 150 kg × 2 |
| Max. Rail Load Capacity | 300 kg |
| Brand | AS ONE |
|---|---|
| Origin | China |
| Manufacturer Type | Manufacturer |
| Instrument Type | General-Purpose Ultrasonic Cleaner |
| Basket Material | Stainless Steel (SUS304) |
| Drain Valve | Included |
| Tank Capacity | 2 L |
| External Dimensions (mm) | 160 × 180 × 220 |
| Internal Tank Dimensions (mm) | 140 × 150 × 100 |
| Brand | AS ONE |
|---|---|
| Model | 1-3216-01 |
| External Dimensions (mm) | 210 × 145 × 140 |
| Internal Tank Dimensions (mm) | 153 × 93 × 50 |
| Net Weight | 1.0 kg |
| Input Voltage | 100 V AC |
| Type | General-Purpose Benchtop Ultrasonic Cleaner |
| Manufacturer Origin | China |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Brand | AS ONE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Number | 2-4120-11 |
| Instrument Category | Vacuum-Compatible Glove Box |
| Application Type | Research-Grade Inert Atmosphere Workstation |
| Chamber Material | Low-Density Polyethylene (LDPE) |
| External Dimensions (L×W×H) | 580 × 430 × 430 mm |
| Glove Ports | 2 |
| Gas Inlet Port Diameter | Ø8 mm |
| Sample Transfer Opening | 340 mm |
| Accessories | PVC Tubing (1 pc), Hose Clamps (2 pcs) |
| RoHS 2 Compliance | EU Directive 2015/863 |
| Brand | AUCMA |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AXD Series |
| Airflow Options | 600 / 1000 / 1300 / 1500 m³/h |
| Mounting Types | Ceiling-Mounted, Wall-Mounted, Mobile Cabinet |
| Operating Mode | Continuous Occupied-Space Disinfection |
| Filtration | High-Efficiency Molecular Filter + Multi-Functional Plasma Module |
| Control Interface | Manual Keypad, Remote Control, Scheduled Operation |
| Compliance | GB 28232–2020 (Plasma Air Disinfection Equipment), YY/T 1808–2021 (Medical Air Disinfectors), ISO 14644-1 Class 8 Compatible Environments |
| Safety Certification | CE Marked (IEC 60335-1, IEC 60335-2-65), RoHS Compliant |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JSQ-II-C |
| Pricing | Available Upon Request |
| Reservoir Capacity | 1500 mL |
| Liquid Level Indication | Low/Full Status Display |
| Drying Method | Infrared-Sensor-Activated Warm Air Drying |
| Water Temperature Options | Infrared-Activated Cold or Hot Water (User-Selectable) |
| Power Supply | 220 V AC / 50 Hz, 800 W |
| Dimensions (W×D×H) | 428 × 200 × 300 mm |
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AS2060B |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | General-Purpose Ultrasonic Cleaner |
| Tank Capacity | 2 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 60 W |
| Power Adjustment | Yes, 50–100% in discrete steps |
| Temperature Control | Not available |
| Timer Range | 5–30 min (mechanical timer), continuous mode supported |
| Sound-Dampening Lid | Included |
| Drain/Refill | Manual valve-controlled drainage |
| Brand | Bandelin |
|---|---|
| Origin | Germany |
| Model | PR140D |
| Tank Capacity | 5 L |
| Ultrasonic Frequency | 35 kHz |
| Ultrasonic Power Output | 120 W |
| Adjustable Power | Yes |
| Adjustable Temperature | No (PR140D) / Yes (PR140DH) |
| Timer Range | 1–30 min |
| Sound-Dampening Lid | Included |
| Drain Valve | Manual |
| Tank Material | AISI 304 Stainless Steel |
| Max. Pipette Length Supported | 755 mm |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Bandelin |
|---|---|
| Origin | Germany |
| Model | DIGITEC Series (DT/DK/RK) |
| Type | General-purpose ultrasonic cleaner |
| Tank capacity | 0.9–90 L |
| Ultrasonic frequency | 35 kHz |
| Ultrasonic power output | 240–2400 W |
| Power adjustment | Yes, 10–100% in 1% increments |
| Temperature control | Yes, 20–80 °C (±1.5 °C accuracy for DIGITEC 10P |
| Timer | 1–99 min or continuous operation |
| Lid with acoustic damping | Yes |
| Manual fill/drain | Yes |
| Heating element | Optional “H” variants |
| Safety features | Over-temperature cutoff, boil-delay protection (selectable), low-level detection, drip-proof housing (IP32–IP33) |
| Tank material | Stainless steel AISI 304 (1.4301) or AISI 316 (1.4571), thickness up to 2 mm |
| Certifications | CE, Medical Device Directive compliant (except RK 1050) |
| Interface | RS232 (DIGITEC 10P), PC software support (DIGITEC 10P only) |
| Data storage | 10 programmable cleaning protocols (DIGITEC 10P) |
| Brand | Bandelin |
|---|---|
| Origin | Germany |
| Model | DL102H |
| Chamber Volume | 3 L |
| Heating Power | 120 W |
| Operating Temperature | Ambient (non-heated mode) |
| Cleaning Solution Compatibility | Single-solution compatible |
| External Dimensions (L×W×D) | 260 × 160 × 250 mm |
| Ultrasonic Peak Power | 480 W |
| Nominal Ultrasonic Power | 120 W |
| Drain Valve | Integrated ball valve |
| Front Panel Material | Anodized aluminum foil |
| Brand | Bandelin |
|---|---|
| Origin | Germany |
| Model | SONOREX RK1028H |
| Tank Volume | 5.5 L |
| Heating Power | 280 W |
| Operating Frequency | 35 kHz |
| External Dimensions (L×W×D) | 325 × 175 × 295 mm |
| Temperature Range | Ambient to 60 °C (heated operation) |
| Brand | BAYE SMART |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BS280 |
| Quotation | Upon Request |
| External Dimensions (L×W×H) | 620 × 710 × 875 mm (845 mm with control panel extension) |
| Cabinet Material | Black explosion-proof tempered glass + brushed stainless steel (AISI 304) |
| Chamber Material | Electropolished SUS 316L mirror-finish stainless steel |
| Chamber Construction | Laser-welded seamless cavity |
| Surface Roughness | Ra ≤ 0.2 µm (large-area), Ra ≤ 0.4 µm (localized features) |
| Capacity | Up to 280 × 25 mL volumetric flasks per cycle |
| Basket Configuration | 2-tier modular rack system with configurable positioning |
| Load Flexibility | Validated partial-load operation (down to 20% nominal capacity) |
| Washing Method | High-precision multi-directional spray arm system with dynamic pressure modulation |
| Control System | Embedded microcomputer with 7-inch capacitive touch HMI |
| Circulation Pump | Variable-speed centrifugal pump, max. flow rate 600 L/min |
| Conductivity Monitoring | Integrated real-time conductivity sensor (0–20 mS/cm, ±0.02 mS/cm accuracy) |
| Data Logging | Full-cycle traceability including temperature, pressure, conductivity, time, and detergent dosage |
| Connectivity | Industrial-grade IoT module supporting MQTT/HTTPS protocols for remote monitoring and firmware OTA updates |
| Compliance | EN ISO 15883-1:2009 & EN ISO 15883-2:2009 (washer-disinfectors for heat-labile medical devices), FDA 21 CFR Part 11 (electronic records & signatures), China GMP Annex I (Sterile Pharmaceutical Production, 2003 Edition), China Pharmaceutical Industry EHS Guidelines (2020) |
| Brand | BAYE SMART |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BS280CD |
| Quotation | Upon Request |
| Chamber Volume | 180 L |
| Heating Power | 6 kW |
| Maximum Wash Temperature | 93 °C |
| Compatible Cleaning Agents | Acidic or Alkaline Liquid Detergents |
| External Dimensions (L×W×D) | 875 (845) × 900 × 710 mm |
| Brand | BAYE SMART |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BS580D |
| Quotation | Upon Request |
| Chamber Volume | 360 L |
| Heating Power | 9 kW |
| Maximum Wash Temperature | 93 °C |
| Compatible Cleaning Agents | Acidic & Alkaline Liquid Detergents |
| External Dimensions (L×W×D) | 1800 × 785 × 765 mm |
| Brand | BEQ |
|---|---|
| Origin | Anhui, China |
| Model | VGT-1990QTD |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 200 W |
| Adjustable Temperature Range | 0–80 °C |
| Timer Range | 1–99 min (LED digital display) |
| Tank Capacity | 9 L |
| Internal Tank Dimensions | 300 × 240 × 150 mm (L×W×H) |
| External Dimensions | 330 × 270 × 310 mm (L×W×H) |
| Drain Valve | Yes |
| Heating System | Ceramic heater |
| Construction | Stainless steel SUS304 tank and housing |
| Transducer Configuration | Four 50 W piezoelectric transducers (total 200 W) |
| Basket Material | Welded SUS304 mesh basket (optional) |
| PCB Protection | Moisture- and corrosion-resistant coating |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Origin | Domestic |
| Model | XL-8 |
| Price | USD 1,650 (approx.) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGM-90FE |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.24 MPa |
| Chamber Dimensions | Ø380 mm × 735 mm |
| External Dimensions | 605 mm × 513 mm × 1040 mm |
| Chamber Volume | 90 L |
| Design Pressure | 0.39 MPa |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ≤1 °C |
| Temperature Fluctuation | ±1 °C |
| Sterilization Time Range | 0–240 min |
| Melting/Insulation Time Range | 0–6000 min |
| Power Input | 3.6 kW |
| Operating Ambient | 5–40 °C, 20–80% RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-100M |
| Instrument Type | Vertical Steam Sterilizer |
| Maximum Temperature | 135 °C |
| Maximum Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 870 mm |
| External Dimensions | 750 × 800 × 1180 mm |
| Chamber Volume | 100 L |
| Heating Power | 6.8 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80 % RH |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BXM-100M |
| Instrument Type | Vertical Sterilizer |
| Max Temperature | 135°C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 870 mm |
| External Dimensions | 750 × 800 × 1180 mm |
| Chamber Volume | 100 L |
| Temperature Range (Sterilization) | 105–135°C |
| Temperature Range (Drying) | 102°C |
| Temperature Range (Melting) | 40–100°C |
| Temperature Range (Heating/Insulation) | 25–85°C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying) | 0–999 min |
| Time Range (Melting/Insulation) | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 6.8 kW |
| Power Supply | ~220 V ±22 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40°C, 20–80% RH |
| Chamber & Basket Material | SUS304 Stainless Steel |
| Cooling Method | Integrated Axial Fan (Forced Air) |
| Air Intake Filtration | Built-in HEPA-grade Filter |
| Water Supply | Dual-channel (Deionized/Pure Water & Tap Water) |
| Standard Probe | Single-channel Sample Temperature Sensor |
| C.W.S. Condensate Reuse System | Yes |
| W.P.S. Waste Gas & Effluent Purification System | Yes |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-110EI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 535 × 640 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | +1 °C |
| Sterilization Temp Range | 105–135 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Melting/Holding Time Range | 0–6000 min |
| 预约 Time | Up to 100 h |
| Heating Power | 3.5 kW |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Operating Ambient | 5–40 °C, 20–80 % RH |
| Cooling System | Standard air-cooling + secondary water-cooling + condenser |
| Safety Protections | Overtemperature cutoff, dry-run protection, overpressure mechanical & electronic relief, anti-scald insulation, overload, short-circuit, and leakage protection |
| User Access Levels | Engineer / Administrator / Operator (3-tier permission management) |
| Programmability | 8 pre-set + 6 user-defined cycles |
| Air Removal | 6-stage positive-pressure pulse with adjustable vacuum-assisted preheating |
| Exhaust Control | 6-level programmable depressurization rate |
| Optional Accessories | 0.2 µm high-temp/pressure exhaust filter, thermal printer with F₀ logging capability (requires optional sample probe), validation port adapter, wired temperature validation interface |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-110FI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 585 × 750 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (extendable to 6000 min) |
| Drying Temp Range | 80–130 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Drying Duration | 10–6000 min |
| Power Input | 5.4 kW |
| Voltage | 220 V ± 10 %, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80 % RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-110VE |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 535 × 640 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Temp Range | 105–135 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Melting/Holding Time Range | 0–6000 min |
| 预约 Function | Up to 100 h |
| Heating Power | 3.5 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Operating Ambient | 5–40 °C, 20–80% RH |
| Cooling System | Standard air-cooling + secondary water-cooling + condenser |
| Safety Protections | Overtemperature shutdown, low-water cutoff, overpressure mechanical relief, independent electronic overpressure sensor, anti-scald insulation, overload protection, short-circuit protection, earth leakage protection |
| User Access Levels | Engineer / Administrator / Operator (3-tier permission management) |
| Interface | Capacitive touchscreen, RS-485 ×2, G1/2A calibration port, waterproof socket ×1 |