Common Laboratory Equipment
Filter
Showing 1–30 of 4523 results
| Origin | United Kingdom |
|---|---|
| Type | Benchtop Centrifuge |
| Maximum Speed | 10,000 rpm |
| Maximum RCF | 12,300 × g |
| Rotor Type | Fixed-angle |
| Standard Rotor Capacity | 12 × 1.5/2.0 mL tubes |
| Optional Rotor Capacity | 32 × 0.2 mL PCR tubes |
| Acceleration Time | <12 s |
| Deceleration Time | <16 s |
| Rotor Material | Corrosion-resistant polymer |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Display | LCD |
| Brand | 2mag |
|---|---|
| Origin | Germany |
| Model | BIOMIX drive 1 |
| Instrument Type | Magnetic Stirrer |
| Maximum Stirring Volume | 5 L |
| Speed Range | 2–250 rpm |
| Temperature Operating Range | Ambient (–10 to +50 °C, high-humidity compatible) |
| IP Rating | IP68 |
| Power per Position | 6 W |
| Housing Material | Stainless Steel (AISI 316L) |
| Dimensions (W × D × H) | 180 × 180 × 38 mm |
| Weight | ~2.3 kg |
| Input Voltage | 48 V DC |
| Brand | 2mag |
|---|---|
| Origin | Germany |
| Model | DRYBATH 15-100 |
| Stirring Points | 15 |
| Max. Stirring Volume per Position | 250 mL |
| Speed Range | 100–2000 rpm |
| Temperature Range | 40–200 °C |
| Heating Power | 1000 W |
| Input Voltage | 230 V AC |
| Protection Class | IP20 |
| Dimensions (W × D × H) | 280 × 430 × 120 mm |
| Weight | ~20 kg |
| Brand | 2mag |
|---|---|
| Origin | Germany |
| Model | maxMIX |
| Maximum Stirring Volume | 150 L |
| Speed Range | 100–1,200 rpm |
| Stirring Power (max) | 40 W |
| Acceleration Time | 20–99 s (adjustable soft-start) |
| IP Rating | IP64 |
| Operating Temperature | −10 to +50 °C |
| Humidity Limit | ≤80% RH |
| Electrical Supply | 100–240 V / 50–60 Hz |
| Dimensions (W × D × H) | 265 × 320 × 68 mm |
| Weight (gross) | ~10 kg |
| Housing Material | Stainless steel (AISI 304) |
| Compliance | FDA-compliant PTFE coating on stir bars, steam-sterilizable at 121 °C |
| Brand | 2mag |
|---|---|
| Origin | Germany |
| Model | MIX 1 |
| Maximum Stirring Volume | 1000 L |
| Speed Range | 0–2000 rpm |
| Temperature Control Range | 0–200 °C |
| Instrument Type | Magnetic Stirrer |
| Warranty | 3 Years (Germany-manufactured) |
| Brand | 2MAG |
|---|---|
| Origin | Germany |
| Model | MIX 1 |
| Stirring Speed Range | 100–2000 rpm |
| Max. Stirring Volume | 10 L |
| Power Settings | 4-step (25/50/75/100%) |
| Housing Material | Stainless Steel, IP64 |
| Operating Temperature | −10 to +50 °C (at 80% RH) |
| Weight | ~4 kg |
| Warranty | 3 Years |
| Brand | 2mag |
|---|---|
| Origin | Germany |
| Model | MIX 1 |
| Instrument Type | Magnetic Stirrer |
| Maximum Stirring Volume | 10 L |
| Speed Range | 100–2000 rpm |
| Operating Temperature | Ambient |
| Housing Material | Stainless Steel (IP64) |
| Power Rating | 20 W |
| Power Settings | 4-step rotary control (25%/50%/75%/100%) |
| Weight | ~4 kg |
| Environmental Rating | -10 to +50 °C at ≤80% RH |
| Brand | 2mag |
|---|---|
| Origin | Germany |
| Model | MIX 15 eco |
| Stirring Positions | 15 |
| Position Spacing | 65 mm |
| Max Volume per Position | 1,500 mL |
| Speed Range | 120–1,200 rpm |
| Power per Unit | 10 W |
| Operating Temperature | −10 °C to +50 °C (80% RH) |
| Input Voltage | 100–240 V, 50–60 Hz |
| IP Rating | IP64 |
| Dimensions (W×D×H) | 245 × 425 × 38 mm |
| Weight | 8.8 kg |
| Enclosure Material | Stainless Steel |
| Display | Digital LED |
| SoftStart Function | Yes |
| Auto-Memory | Yes |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | 2mag |
|---|---|
| Origin | Germany |
| Model | MIXdrive 1 eco |
| Instrument Type | Magnetic Stirrer |
| Max. Stirring Volume | 3 L |
| Speed Range | 100–2,000 rpm |
| Temperature Resistance | Up to +200 °C (oven), up to +95 °C (submerged in water/oil bath) |
| IP Rating | IP68 |
| Footprint | 12 × 12 cm |
| Warranty | 3 years |
| Drive Principle | Contactless Inductive Magnetic Drive |
| Enclosure Material | Fully Sealed Stainless Steel |
| Brand | 2mag |
|---|---|
| Origin | Germany |
| Model | MIXdrive |
| Stirring Volume per Position | Up to 250 L |
| Speed Range | 120–1200 rpm |
| Temperature Resistance | Up to 200 °C |
| IP Rating | IP64 |
| Drive Principle | Contactless Induction Motor (No Mechanical Wear) |
| Housing Material | Stainless Steel (AISI 304) |
| Operating Voltage | 24 V DC |
| Dimensions (W×D×H) | 260 × 260 × 68 mm |
| Weight | 9.8 kg |
| Ambient Operating Conditions | −10 to +50 °C, ≤95% RH |
| Warranty | 3 Years |
| Brand | 2mag |
|---|---|
| Origin | Germany |
| Model | STIRRING DRYBATH 15-100 |
| Max. Stirring Volume | 150 mL |
| Speed Range | 100–2000 rpm |
| Temperature Range | 40–200 °C |
| Heating Power | 1000 W |
| Stirring Positions | 15 |
| Block Dimensions (Ø/Depth) | 57.5 mm / 48 mm |
| Spacing Between Holes | 65 mm |
| Voltage | 230 V, 50–60 Hz |
| IP Rating | IP20 |
| Weight | 20 kg (main unit), 2.2 kg (heatMIXcontrol) |
| Brand | 2mag |
|---|---|
| Origin | Germany |
| Model | Stirring Hotplate 15 |
| Max. Stirring Volume per Position | 1,000 mL |
| Speed Range | 100–2,000 rpm |
| Temperature Range | +40 °C to +200 °C |
| Stirring Positions | 15 |
| Stirring Point Spacing | 65 mm |
| Stirring Power | 40 W per position |
| Power Setting | 10-step (10–100%) |
| Heating Output | 1,200 W at 230 V |
| Plate Material | Anodized Aluminum with PTFE Coating |
| Dimensions (W×D×H) | 250 × 430 × 75 mm |
| Weight | ~13.0 kg |
| IP Rating | IP20 |
| Voltage | 230 V AC |
| Brand | 3D Systems |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | Contact for Quote |
| Brand | 3D Systems |
|---|---|
| Technology | DLP (Digital Light Processing) |
| Process | UV-Curable Resin Photopolymerization |
| Architecture | Modular, Standalone Platform |
| Material Class | Engineering-Grade Thermoset Resins |
| Surface Finish | Molecular-Level Smoothness |
| Build Approach | Continuous Liquid Interface Production (CLIP)-Inspired Digital Light Synthesis™ |
| Compliance | Designed for ISO 13485-aligned environments |
| Brand | 3D Systems |
|---|---|
| Technology | Multi-Jet Printing (MJP) |
| Build Volume (W×D×H) | 294 × 211 × 144 mm |
| Resolution | Up to 1600 × 900 × 790 DPI |
| Minimum Feature Size | ≤ 300 µm |
| Material Compatibility | VisiJet Rigid, Elastic, High-Temp, Biocompatible (USP Class VI / ISO 10993 compliant), Transparent & Opaque Resins |
| Software | 3D Sprint v2.0+ |
| Post-Processing | MJP EasyClean System (optional) |
| Cloud Connectivity | 3D Connect™ with Predictive Support & Remote Diagnostics |
| Compliance | FDA 21 CFR Part 11 ready (with audit trail configuration), GLP/GMP-aligned workflow documentation |
| Brand | 3D Systems |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Quotation | Upon Request |
| Print Technology | Color Jet Printing (CJP) |
| Max Build Volume | 508 × 381 × 229 mm |
| Layer Thickness | 0.1 mm |
| Resolution | 600 × 540 DPI |
| Color Gamut | >6 million colors |
| Build Speed | 5–15 mm/h (vertical) |
| Print Head Count | 5 |
| Nozzle Count | 1520 |
| Material | VisiJet® PXL™ powder |
| Supported Formats | STL, VRML, PLY, 3DS, FBX, ZPR |
| Operating Temp | 13–24 °C |
| Humidity | 20–55% non-cond. |
| Power | 100–240 V, 7.5–15 A |
| Noise Level | ≤57 dB (build), ≤66 dB (core recycle), ≤86 dB (vacuum open) |
| Certifications | CE, CSA |
| Software | 3D Sprint™ with remote monitoring via tablet/desktop/smartphone |
| Post-Processing | Integrated powder removal system |
| Safety | Enclosed vacuum-assisted particulate containment, no solvents or hazardous waste |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | 4IR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CPT-230 |
| Price Range | USD 14,000 – 42,500 |
| Key | Brand: AZENTA (formerly Brooks Automation) |
|---|---|
| Origin | USA |
| Product Type | Sealing Films, PCR Plates, Strip Tubes, Thermal Sealers |
| Compatibility | AZENTA A4S, Thermo Fisher KingFisher/Thermo Sealers, Agilent BioTek, Roche LightCycler, ABI QuantStudio |
| Regulatory Context | Designed for ISO 13485–compliant IVD workflows and FDA-cleared molecular diagnostic assay support |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | MPA-10 |
| Pipette Type | Single-Channel Electronic Pipette |
| Volume Range | 0.5–10 µL |
| Accuracy (at 1 µL / 10 µL) | ±4% / ±1% |
| Precision (CV at 1 µL / 10 µL) | 2.5% / 0.4% |
| Power Source | Rechargeable Li-ion Battery (USB Charging) |
| Calibration | User-Accessible Gravimetric and Volumetric Adjustment |
| Operating Modes | Standard Pipetting, Multiple Dispensing, Mixing, Reverse Pipetting |
| Tip Ejection | Spring-Loaded, Tool-Free Installation & Sealing |
| Display | Impact-Resistant LCD with Shock-Absorbing Housing |
| Ergonomics | Low-Actuation-Force Touch Buttons, Optimized Weight Distribution for Reduced Repetitive Strain |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MPA-10000 |
| Instrument Type | Single-Channel Electronic Pipette |
| Automation Level | Motorized |
| Channel Count | 1 |
| Volume Range | 0.1–10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.5% (at 0.1 mL), ±1.0% (at 5.0 mL), ±0.5% (at 10.0 mL) |
| Precision (CV) | ≤0.6% (at 0.1 mL), ≤0.15% (at 5.0 mL and 10.0 mL) |
| Power Source | Rechargeable Lithium-ion Battery |
| Charging Interface | USB-C |
| Tip Attachment | Spring-assisted, leak-tight seal without manual compression |
| Calibration | User-accessible gravimetric and volumetric calibration routines |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported |
| Model | MPA-1200 |
| Instrument Category | Single-Channel Pipette |
| Automation Level | Electronic |
| Channels | 1 |
| Volume Range | 100–1200 µL |
| Maximum Capacity | 1200 µL |
| Accuracy | ±0.5% at 1200 µL, ±2.5% at 100 µL |
| Precision (CV) | ±0.15% at 1200 µL, ±0.6% at 100 µL |
| Power Source | Rechargeable Li-ion Battery |
| Charging Interface | USB-C |
| Calibration | User-performed gravimetric and volumetric calibration |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | MPA-20 |
| Pipette Type | Electronic Single-Channel |
| Volume Range | 2–20 µL |
| Accuracy (at 2 µL / 20 µL) | ±4% / ±1% |
| Precision (CV, at 2 µL / 20 µL) | 2.5% / 0.4% |
| Power Source | Rechargeable Lithium-ion Battery (USB Charging) |
| Display | Impact-Resistant LCD |
| Tip Attachment | Auto-Seal Snap-fit Mechanism |
| Calibration | User-Accessible Gravimetric and Volumetric Adjustment |
| Compliance | Designed to support ISO 8655-2:2022 and GLP/GMP workflows |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MPA-200 |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Motorized |
| Channels | 1 |
| Volume Range | 10–200 µL |
| Maximum Capacity | 200 µL |
| Accuracy | ±2.5% at 10 µL, ±0.6% at 200 µL |
| Precision (CV) | ≤1.0% at 10 µL, ≤0.15% at 200 µL |
| Power Source | Rechargeable Lithium-ion Battery |
| Charging Interface | USB-C |
| Calibration | User-accessible gravimetric and volumetric calibration routines |
| Brand | AA OPTO Electronic |
|---|---|
| Model | BIOCOOL20-200-1 |
| Temperature Range | −20 °C to 200 °C |
| Nominal Cooling Capacity | 2.5 kW |
| Low-Temp Cooling Capacity | 0.9 kW @ −20 °C, 2.0 kW @ 20 °C, 2.0 kW @ 200 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Pressure Range | 1.5–2.5 bar |
| Flow Rate (Customizable) | 8–80 L/min |
| Max. Ramp Rate | 20 °C/min |
| Standard Programmable Stages | 12 (expandable to 36) |
| Interface | Industrial communication ports (RS485, Modbus TCP, optional Ethernet/IP), PC & mobile APP support |
| Dimensions (W×D×H) | 500 × 500 × 1500 mm |
| Inlet/Outlet Port | 1/2″ BSP/Female NPT |
| Brand | AA OPTO Electronic |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | Cryo-Optimized Micro-Volume Precision Filling System |
| Z-Axis Travel | 100 mm |
| Filling Accuracy | <2% RSD |
| Input Power | 220 V / 50 Hz |
| Operating Mode | Semi-Automatic Standalone Unit |
| Minimum Single-Head Fill Volume | >10 µL |
| Power Consumption | 1.3 kW |
| Channel Configurability | Modular (Scalable from 1 to 16 Channels) |
| Compliance | Designed for ISO 5 Cleanroom-Compatible Environments |
| Control Architecture | Independent Per-Channel PID-Regulated Dispensing Logic |
| Brand | AA OPTO Electronic |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | Freeze-Dried Microsphere-Specific Isolator |
| Leak Rate | <0.001 vol% / h |
| H₂O Content | <1 ppm (v/v) |
| O₂ Content | <1 ppm (v/v) |
| Oxygen Scavenger Capacity | 8 kg (effective O₂ removal: 120 L) |
| Desiccant Capacity | 16 kg (effective H₂O removal: 5 kg) |
| Regeneration Efficiency (per cycle) | >80% |
| Chamber Material | 316L Stainless Steel |
| Large Transfer Lock | Ø360 mm × 600 mm (left/right configurable) |
| Small Transfer Lock | Ø150 mm × 300 mm |
| Glove Ports | Dual, ISO-KF40 flanged, with integrated dry-box gloves |
| Internal Lighting | LED, explosion-proof rated |
| Power Outlets | Multifunctional, intrinsically safe, 24 V DC / 230 V AC isolated |
| Shelving | Adjustable, 900 mm × 200 mm stainless steel |
| Circulation System | High-efficiency centrifugal blower, dual-bed purification (O₂/H₂O/organics), HEPA-filtered recirculation |
| Regeneration System | Automated thermal/chemical reactivation module |
| Pressure Control | PID-controlled differential pressure regulation (±0.5 Pa resolution) |
| Control System | Industrial PLC with 10.1" HMI touchscreen, audit-trail enabled |
| Analytical Sensors | Integrated tunable diode laser (TDLAS)-based O₂ analyzer, chilled-mirror dew point sensor (–90 °C DP accuracy ±0.2 °C) |
| Vacuum System | Oil-free scroll pump, programmable auto-start/stop |
| Safety | Footswitch for manual pressure override, redundant leak detection protocol |
| Compliance | Designed per ISO 14644-1 Class 5 (at operation), compatible with GMP Annex 1 (2022) isolator qualification requirements |
| Brand | AA OPTO Electronic |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | Freeze-Dried Powder High-Speed Filling Machine |
| Filling Volume Range | 10–30 mL, 30–60 mL, 50–120 mL, 100–250 mL (customizable) |
| Bottle Compatibility | Round, Oval, and Irregular-Shaped Vials |
| Filling Nozzles | 4, 6, 8, 12, 16, 18, 20 (configurable) |
| Filling Principle Options | Piston (316L stainless steel or ceramic), Peristaltic Pump, Vacuum-Assisted, Gravity-Flow, Weighing-Based, Flowmeter-Controlled |
| Filling Accuracy | ≤ ±1% |
| Capping Stations | 1, 2, 4, 6, 8, 12, 16, 20, or 24 heads (configurable) |
| Compliance | Designed to meet current Good Manufacturing Practice (cGMP) requirements per Annex 1 (EU) and US FDA 21 CFR Part 211 |
| Brand | AA OPTO Electronic |
|---|---|
| Model | KPGZ-1 |
| Application | Sterile liquid filling, stoppering & crimping for lyophilization vials |
| Throughput | 20–40 vials/min (5–10 mL capacity) |
| Filling Accuracy | ≤ ±1% |
| Power Supply | Single-phase 380 V / 50 Hz |
| Total Power Consumption | 1.5 kW |
| Main Motor Power | 0.75 kW |
| Compressed Air Requirement | 0.3–0.5 MPa |
| Dimensions (L×W×H) | 1650 × 1000 × 1750 mm |
| Weight | ~450 kg |
| Construction | 304 stainless steel contact parts |
| Control System | Siemens PLC + Weintek HMI touchscreen |
| Drive | TAIAN frequency inverter with stepless speed regulation |
| Sensors | Omron photoelectric bottle detection, AUTONICS proximity switches |
| Pneumatics | Airtac solenoid valves |
| Gear Mechanism | JINGCHENG cam indexer |
| Compliance | Designed for GMP-compliant aseptic environments |