Common Laboratory Equipment
Filter
Showing 331–360 of 4601 results
| Brand | AIRTECH (Sujing Antai) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | Dual-Door |
| Quotation | Available Upon Request |
| Filter Efficiency | ≥99.99% @ ≥0.3 µm |
| Nozzle Air Velocity | ≥25 m/s |
| Number of Nozzles | 16 |
| Power Supply | AC 380 V, 3-phase, 50 Hz |
| Rated Power | 1.8 kW + 1.5 kW × (i − 1) |
| Cabinet Material | High-Quality Powder-Coated Steel |
| Floor Pan | Not Included |
| External Dimensions (W×D×H) | (W₁ + 400) mm × (D₁ + 100) mm × (H₁ + 90) mm |
| Working Area Dimensions (W×D×H) | W₁ × D₁ × H₁ mm |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | SW-CJ-1B, SW-CJ-1BU, SW-CJ-1C, SW-CJ-1CU |
| Instrument Category | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (CFDA Medical Device Standard), Class II Medical Device Registration Certificate |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Models | SW-CJ-1F, SW-CJ-1FD, SW-CJ-2F, SW-CJ-2FD |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-Operator Single-Face, Single-Operator Dual-Face, Dual-Operator Single-Face, Dual-Operator Dual-Face |
| Airflow Pattern | Vertical Downflow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate Issued |
| Brand | AIRTECH (Suzhou Antai) |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (equivalent to US FED STD 209E Class 100) |
| Noise Level | ≤62 dB(A) |
| User Configuration | Dual-operator, dual-sided (SW-CJ-2F) or dual-operator, single-sided (SW-CJ-2FD) |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Average Air Velocity | ≥0.3 m/s (adjustable) |
| Illumination | ≥300 lx |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 500 W |
| Weight | 170 kg |
| Work Area Dimensions (W×D×H) | 1360×690×520 mm (SW-CJ-2F), 1360×690×520 mm (SW-CJ-2FD) |
| Overall Dimensions (W×D×H) | 1500×750×1600 mm (SW-CJ-2F), 1500×730×1600 mm (SW-CJ-2FD) |
| HEPA Filter Specification | 610×610×50 mm ×2 units |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| Pre-filter | Quick-access washable design |
| Control Interface | Digital display with touch keys |
| Safety Interlock | UV lamp and lighting circuit interlocked |
| UV Timer Function | Programmable on/off scheduling |
| Runtime Monitoring | Real-time cumulative operating hours for fan, UV lamp, and HEPA filter |
| Construction | Stainless steel monolithic work surface |
| Mobility | Locking omnidirectional casters |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Models | SW-CJ-1B / SW-CJ-1BU / SW-CJ-1C / SW-CJ-1CU-II |
| Instrument Type | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single- or Dual-Operator, Front-Access Only |
| Airflow Pattern | Horizontal Laminar Flow |
| Control Interface | Digital Display with Touch-Sensitive Keypad |
| UV Timer Function | Programmable On/Off Scheduling |
| Runtime Monitoring | Real-Time Accumulated Hours for Fan, UV Lamp, and Pre-Filter |
| Viewing Panels | Embedded Tempered Glass on Both Sides |
| Work Surface | Seamless Stainless Steel (AISI 304) |
| Enclosure Material | Cold-Rolled Steel with Ivory White Electrostatic Powder Coating |
| Structural Design | Aerodynamically Optimized Cabinet Profile |
| Mobility System | Locking Swivel Casters (360° Rotation) |
| Pre-Filter Access | Tool-Free Quick-Release Mechanism |
| Safety Interlock | UV Lamp Deactivation When Lighting Circuit Is Active |
| Power Protection | Built-in Backup Socket with Emergency Power-Off Capability |
| Compliance | Factory-Tested per GB/T 25227–2010 (Chinese National Standard for Clean Benches), Meets IEC 61010-1 Safety Requirements for Laboratory Equipment |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | SW-CJ-1F, SW-CJ-1FD, SW-CJ-2F, SW-CJ-2FD-II |
| Airflow Type | Vertical Downflow |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| Operator Configurations | Single-Person/Single-Side, Single-Person/Double-Side, Double-Person/Single-Side, Double-Person/Double-Side |
| Construction | Stainless Steel Work Surface, Powder-Coated Cold-Rolled Steel Enclosure |
| Pre-Filter | Quick-Release Design for Easy Cleaning and Replacement |
| UV Lamp Control | Programmable On/Off Scheduling with Runtime Monitoring |
| Fan Speed | Three-Step Adjustable |
| Safety Interlock | Lighting and UV Sterilization Systems Are Electrically Interlocked |
| Power Protection | Built-in Uninterruptible Power Backup Function |
| Mobility | Locking Swivel Casters with Brake Mechanism |
| Compliance | Factory-Tested per GB/T 25223–2010 (Chinese National Standard for Clean Benches), Meets General Requirements of YY 0569–2011 (Medical Device Safety for Biological Safety Cabinets) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VS-840K-II |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100 per Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Average Air Velocity | ≥0.3 m/s (adjustable in three stages) |
| Illumination | ≥300 lx |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 250 W |
| Net Weight | 145 kg |
| Work Area Dimensions (W×D×H) | 680 × 650 × 570 mm |
| Overall Dimensions (W×D×H) | 840 × 825 × 1625 mm |
| HEPA Filter Specification | 760 × 610 × 50 mm × 1 unit |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| Pre-filter | Quick-release, washable design |
| UV Lamp | Scheduled on/off control with runtime logging |
| Safety Interlock | Lighting and UV sterilization systems mutually interlocked |
| Foot Mobility | Dual-mode casters (swivel + locking leveling feet) |
| Brand | Aist ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SH-3 |
| Pricing | Available Upon Request |
| Rated Force | 50 kN |
| Platen Closure Height | 50 mm |
| Platen Stroke | 6.5 mm |
| Maximum Hand Lever Effort | 210 N |
| Net Weight | 14 kg |
| Dimensions (L×W×H) | 180 × 330 × 280 mm |
| Brand | AISTI |
|---|---|
| Origin | Japan |
| Device Type | Fully Automated Online SPE-LC Coupled System |
| Model | SPL-W100 |
| Automation Level | Fully Automatic |
| Channel Configuration | Multi-Channel |
| Extraction Format | Cartridge-Based SPE |
| Flow Rate Control Range | 0.1–30 mL/min |
| Solvent Selection Capacity | 5 Independent Solvent Lines |
| Sample Capacity | 50 Positions |
| Sample Loading Volume | 1.5 mL per Vial |
| Wetted Materials | Borosilicate Glass, PTFE, and Chemically Inert Elastomers |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Extru25-20 |
| Instrument Type | High-Pressure Pneumatic Extruder |
| Dimensions (W×D×H) | 280 × 440 × 260 mm |
| Sample Volume Range | 0–20 mL |
| Maximum Operating Pressure | 25 MPa |
| Final Particle Size Range | 50–1000 nm |
| Maximum Product Concentration | 200 mg/mL |
| Operating Temperature Range | 5–80 °C |
| Construction Material | SS316L |
| Membrane Diameter | 25 mm |
| Power Source | Compressed Nitrogen Gas |
| Residual Volume | < 10 µL |
| Temperature Control | Integrated Jacketed Chamber with External Circulator Compatibility |
| Regulatory Compliance | All elastomeric components (O-rings, gaskets) FDA-compliant per 21 CFR §177.2600 |
| Brand | Aitesen |
|---|---|
| Model | HPEx-L1 |
| Type | Manual Liposome Extrusion Device |
| Sample Volume Range | 0.1–1.0 mL per run |
| Residual Volume | 0 mL |
| Polycarbonate (PC) Membrane Diameter | 19 mm |
| Available Membrane Pore Sizes | 50 nm, 100 nm, 200 nm, 400 nm, 800 nm |
| Temperature Compatibility | Water-bath compatible (ambient to 60 °C) |
| Weight | <2 kg |
| Cleaning | Fully disassemblable |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Model | HPH-L2 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 545 × 755 × 494 mm |
| Maximum Pressure | 2000 bar |
| Maximum Feed Particle Size | 500 µm |
| Flow Rate | 5–15 L/h |
| Minimum Sample Volume | 15 mL |
| Noise Level | 65 dB(A) |
| Power Rating | 1.5 kW |
| Material of Wetted Parts | SAF2507 Super Duplex Stainless Steel |
| Compliance | Manufactured per EU Machinery Directive 98/37/EC (MD) |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | High-Pressure Homogenizer |
| Structural Design | Modular Pump Head |
| Valve Material | SAF2507 Super Duplex Stainless Steel |
| Pressure Regulation | Manual & Pneumatic |
| Control Interface | Touchscreen Panel |
| Data Logging | Real-Time Pressure Monitoring & Exportable Records |
| Safety Features | Adjustable Pressure Limit with Audible/Visual Alarm |
| Optional Modules | Variable-Frequency Flow Control, Automated Pressurization, PLC Integration, Temperature Control, Multi-Stage Homogenization, Closed-Loop Circulation, Pre-Processing Unit |
| Flow Rate Range | 80–2000 L/h |
| Maximum Operating Pressure | 1500 bar (standard), 1000 bar (high-flow configurations) |
| Compliance | Designed for GMP-aligned process development and scale-up per ISO 22411, ASTM E2456, and USP <1119> guidelines |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MPE-L1 |
| Instrument Type | High-Pressure Microfluidic Emulsification System |
| Dimensions (W×D×H) | 280 × 440 × 260 mm |
| Flow Rate Range | 0.1–200 mL/min |
| Pressure Range | 0–25 MPa |
| Temperature Control Range | 4–100 °C |
| Flow Accuracy | ≤ ±1% |
| Flow Repeatability | ≤ 1% |
| Pressure Pulsation | ≤ 0.1 MPa |
| Pressure Accuracy | ≤ 0.1 MPa |
| Minimum Channel Width | 20 µm |
| Particle Size Output | <100 nm |
| Polydispersity Index (PDI) | <0.1 |
| Brand | Aitesen |
|---|---|
| Model | OLExS-Pd |
| Instrument Type | Microfluidic Extrusion System |
| Processing Volume | 100–5000 mL |
| Dimensions (W×D×H) | 280 × 440 × 260 mm |
| Origin | Jiangsu, China |
| Supplier Type | Authorized Distributor |
| Regulatory Classification | Domestic Laboratory-Grade Equipment |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Model | RSS-L1 |
| Type | Benchtop Sterilizer |
| Max Temperature | 0–150 °C (±0.1 °C) |
| Chamber Volume Capacity | 10–2000 mL |
| Max Working Pressure | 0.3 MPa |
| Total Power | 7.5 kW |
| Sample Capacity | 1–10 vessels |
| Temperature Sensors | ≥3 independent RTD probes |
| Output Parameters | Temperature, Pressure, F₀, Time, Rotation Speed, Steam Flow (where applicable) |
| Brand | Aitesen |
|---|---|
| Model | TBX001 |
| Instrument Type | High-Pressure Extruder |
| Dimensions (W×D×H) | 80 × 140 × 60 mm |
| Sample Volume Range | 0–10 mL |
| Maximum Operating Pressure | 1000 psi |
| Final Particle Size Range | 50–1000 nm |
| Polydispersity Index (PDI) | <0.1 achievable |
| Operating Temperature Range | 5–75 °C |
| Maximum Lipid Concentration | 200 mg/mL |
| Construction Materials | 316L stainless steel body, polycarbonate (PC) track-etched membranes, FDA-compliant PU/PTFE seals |
| Temperature Control | Jacketed with external recirculating chiller |
| Compliance | Designed for GMP-compliant cleanroom use |
| Brand | Aitesen |
|---|---|
| Model | TLEx-100 |
| Type | Nitrogen-Driven Membrane Extrusion System |
| Max. Sample Volume | 100 mL |
| Dimensions (W×D×H) | 80 × 140 × 60 mm |
| Construction Materials | SS316L Support/Filter Plates, Polycarbonate (PC) Track-Etched Membranes, FDA-Certified PU/PTFE Seals |
| Temperature Control | Jacketed Heating (up to 70 °C) |
| Pressure Source | Regulated Compressed Nitrogen |
| Sterilization Compatibility | Autoclavable Components (121 °C, 20 min) |
| Compliance | GMP-Aligned Design, Suitable for ISO Class 5–7 Cleanrooms |
| Particle Size Output | Typically <100 nm, PDI <0.1 (with appropriate membrane pore size and cycling protocol) |
| Brand | AITSEN |
|---|---|
| Model | HPH-L3 |
| Type | High-Pressure Piston-Type Homogenizer |
| Construction | Modular Pump Head Design |
| Wetted Materials | SAF2507 Super Duplex Stainless Steel |
| Maximum Operating Pressure | 1800 bar |
| Flow Rate Range | 10–40 L/h |
| Minimum Sample Volume | 30 mL |
| Dimensions (W×D×H) | 658 × 868 × 920 mm |
| Weight | 280 kg |
| Noise Level | ≤65 dB(A) |
| Power Supply | 5.5 kW |
| Compliance | Manufactured per EU Machinery Directive 98/37/EC (MD) |
| Sterilization & Cleaning | CIP-Compatible, Autoclavable Components |
| Control Interface | Touchscreen HMI with Real-Time Pressure Monitoring, Data Logging, and Export (CSV/Excel) |
| Optional Systems | Frequency-Controlled Flow Regulation, Pneumatic/Automatic Pressure Actuation, PLC-Based Process Logic Control, Jacketed Temperature Control, Multi-Stage Homogenization, Closed-Loop Recirculation, Pre-Conditioning Module |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS03 |
| Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 100 W |
| Power Adjustment | Yes, 40–100% |
| Timer Range | 1–199 min |
| Heating Function | No |
| Drain Valve | No |
| Lid (Noise Reduction) | No |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen |
| Safety Features | Built-in Leak Protection, Overload & Overheat Protection |
| Dimensions (W×D×H) | 301 × 163 × 242 mm |
| Internal Tank Size (W×D×H) | 240 × 140 × 100 mm |
| Brand | alalis |
|---|---|
| Origin | USA |
| Model | AS03T |
| Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 100 W |
| Power Adjustment Range | 40–100% |
| Temperature Control Range | 20–65 °C |
| Timer Range | 1–199 min |
| Sound-Dampening Lid | Yes |
| Drain Valve | No |
| Heating Power | 90 W |
| Internal Dimensions (L×W×H) | 240 × 140 × 100 mm |
| External Dimensions (L×W×H) | 301 × 163 × 242 mm |
| Display | Touchscreen |
| Leak Protection | Yes |
| Tray | Included |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS06 |
| Capacity | 6 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 150 W |
| Power Adjustment | Yes, 40–100% |
| Timer Range | 1–199 min |
| Heating Function | No |
| Drain Valve | No |
| Sound-Dampening Lid | No |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen |
| Safety Features | Built-in Leak Protection, Overload & Overheat Protection |
| Dimensions (W×D×H) | 362 × 180 × 305 mm |
| Internal Tank Size (W×D×H) | 300 × 150 × 150 mm |
| Brand | alalis |
|---|---|
| Origin | USA |
| Model | AS06T |
| Capacity | 6 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 150 W |
| Power Adjustment | Yes, 40–100% |
| Temperature Control | Yes, 20–65 °C |
| Timer Range | 1–199 min |
| Sound-Dampening Lid | Included |
| Drain Valve | Not equipped |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS10 |
| Capacity | 10 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 200 W |
| Power Adjustment | Yes (40–100%) |
| Timer Range | 1–199 min |
| Drain Valve | Yes |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen |
| Safety Features | Built-in Leak Protection, Overload & Overheat Protection |
| Compliance | Meets ASTM D2607 and ISO 13850 for laboratory ultrasonic cleaning systems |
| Software | Non-PC-based embedded control with parameter memory retention after power loss |
| Brand | alalis |
|---|---|
| Origin | USA |
| Model | AS10T |
| Capacity | 10 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 200 W |
| Power Adjustment | Yes (40–100%) |
| Temperature Control | Yes (20–65 °C) |
| Timer Range | 1–199 min |
| Sound-Dampening Lid | Included |
| Drain Valve & Fill Port | Integrated |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS15 |
| Capacity | 15 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 350 W |
| Power Adjustment | Yes, 40–100% |
| Timer Range | 1–199 min |
| Drain Valve | Yes |
| Noise-Reduction Lid | No |
| Heating Function | Not equipped |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen |
| Safety Features | Built-in leak protection, overheat & overload protection |
| Compliance | Meets ASTM D2604 and ISO 13847 requirements for ultrasonic cleaning validation |
| Brand | alalis |
|---|---|
| Origin | USA |
| Model | AS15T |
| Capacity | 15 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 350 W |
| Power Adjustment | Yes (40–100%) |
| Temperature Control | Yes (20–65 °C) |
| Timer Range | 1–199 min |
| Sound-Dampening Lid | Included |
| Drain & Fill Ports | Equipped |
| Construction | 304 Stainless Steel Tank |
| Display | Capacitive Touchscreen Interface |
| Safety Features | Leak Detection, Overheat & Overload Protection |
| Compliance | Meets ASTM D2276, ISO 13843, and IEC 61000-6-3 for laboratory-grade ultrasonic cleaning systems |
| Brand | alalis |
|---|---|
| Origin | USA |
| Model | AS20 |
| Capacity | 20 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 400 W |
| Power Adjustment | Yes, 40–100% |
| Timer Range | 1–199 min |
| Drain Valve | Yes |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen Interface |
| Safety Features | Built-in Leak Protection, Overload & Overheat Protection |
| Compliance | Meets ASTM D2607 (Ultrasonic Cleaning Performance Testing), ISO 13485 (Medical Device Manufacturing Support), and GLP-relevant operational traceability requirements |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS20T |
| Capacity | 20 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 400 W |
| Power Adjustment Range | 40–100% |
| Temperature Control Range | 20–65 °C |
| Timer Range | 1–199 min |
| Sound-Dampening Lid | Yes |
| Drain & Fill Ports | Yes |
| Construction | 304 Stainless Steel Tank |
| Heating Power | 560 W |
| Display | Capacitive Touchscreen |
| Safety Features | Leak Protection, Overheat & Overload Protection, Auto Diagnostic Function |
| Dimensions (Overall) | 584 × 327 × 327 mm |
| Tank Internal Dimensions | 500 × 300 × 150 mm |
| Compliance | Meets ASTM D2603, ISO 13847, and IEC 61000-6-3 for laboratory ultrasonic equipment |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS30 |
| Capacity | 30 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 500 W |
| Power Adjustment | Yes, 40–100% |
| Timer Range | 1–199 min |
| Drain Valve | Yes |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen |
| Safety Features | Built-in Leak Protection, Overload & Overheat Protection |
| Dimensions (W×D×H) | 584 × 327 × 375 mm |
| Internal Tank Size (W×D×H) | 500 × 300 × 200 mm |
| Compliance | Meets ASTM D4296, ISO 13845, and general laboratory equipment safety requirements for non-heated ultrasonic cleaning systems |