Common Laboratory Equipment
Filter
Showing 2401–2430 of 5364 results
| Brand | Exaddon |
|---|---|
| Origin | Switzerland |
| Model | CERES |
| Laser Wavelength | 405 nm |
| Print Resolution | <1 µm |
| Max. Structure Height | 10 mm |
| Chamber Dimensions | 120 mm × 70 mm |
| Pressure Range | −800 to +1000 mbar |
| Bidirectional XY Repeatability | <500 nm |
| Printing Principle | Electrochemical Deposition (ECD) |
| Brand | EXAKT |
|---|---|
| Origin | Germany |
| Model | 120EH-250 |
| Roller Diameter | 120 mm |
| Roller Length | 250 mm |
| Speed Ratio (n₁ | n₂:n₃): 9:3:1 |
| Feed Particle Size | 5–180 µm |
| Final Output Particle Size | ≤1 µm |
| Throughput Capacity | 0.5–30 L/h |
| Roller Material Options | Hard-chrome-plated stainless steel / Alumina / Polished alumina / Zirconia / Silicon carbide |
| Doctor Blade Material Options | Stainless steel / Plastic / Alumina / Zirconia |
| Motor Power | 3.0 kW |
| Max. Roller Temperature | 80 °C (heating/cooling capable) |
| Dimensions (W×D×H, incl. blade & hopper) | 870 × 950 × 1320 mm |
| Weight | 320 kg |
| Brand | EXAKT |
|---|---|
| Origin | Germany |
| Model | 120EH-450 |
| Instrument Type | Three-Roll Mill |
| Sample Applicability | Soft and semi-viscous materials |
| Feed Particle Size | 5–180 µm |
| Final Output Particle Size | ≤1 µm |
| Throughput Capacity | 1–60 L/h |
| Roller Diameter | 120 mm |
| Roller Length | 450 mm |
| Speed Ratio | 9:3:1 |
| Roller Material | Hard-chrome-plated stainless steel / Alumina / Polished alumina / Silicon carbide |
| Doctor Blade Material | Stainless steel / Plastic / Alumina / Zirconia |
| Drive | Inverter-controlled electronic speed regulation |
| Motor Power | 3 kW |
| Roller Temperature Control | Cooled or heated up to 80 °C |
| Dimensions (W×D×H) | 1070 × 950 × 1320 mm |
| Weight | 390 kg |
| Brand | EXAKT |
|---|---|
| Origin | Germany |
| Model | 120S-450 |
| Instrument Type | Three-Roll Mill |
| Sample Applicability | Soft to semi-viscous materials |
| Feed Particle Size | 5–180 µm |
| Final Output Particle Size | 1–9 µm |
| Throughput Capacity | 0.01–5.7 L/hr |
| Roll Diameter | 120 mm |
| Roll Length | 450 mm |
| Roll Speed Ratio | 2.9 : 1.7 : 1 |
| Roll Material | Hard-chrome-plated stainless steel, polished alumina, or zirconia |
| Roller Surface Finish | Polished alumina or chemically treated zirconia |
| Scraper Materials | Stainless steel, PTFE, alumina, zirconia |
| Drive Options | Single-speed (1.5 kW), dual-speed (0.55/1.1 kW), or inverter-controlled variable-speed (1.5 kW) |
| Cooling/Heating Capability | Standard — up to 80 °C |
| Dimensions (W×D×H, with scraper & hopper) | 820 × 650 × 660 mm |
| Electrical Supply | 230 V / 50 Hz or 400 V / 50 Hz |
| Safety Certification | CE-compliant |
| Optional | ATEX-certified explosion-proof configuration, PFA-coated universal scraper system |
| Brand | EXAKT |
|---|---|
| Origin | Germany |
| Model | Basic Model 80 |
| Instrument Type | Three-Roll Mill |
| Sample Suitability | Soft to semi-viscous materials |
| Feed Particle Size | 5–180 µm |
| Final Output Particle Size | ≤1 µm |
| Throughput Capacity | 0.02–45 L/h |
| Roll Diameter | 80 mm |
| Roll Length | 250 mm |
| Roll Speed Ratio | 3.3 : 1.8 : 1 |
| Roll Material | Hard-chromed stainless steel & alumina-coated surfaces |
| Blade Material | Stainless steel & polymer (ceramic blades optional) |
| Drive | Dual-speed or continuously variable motor (0.3 / 0.45 kW) |
| Dimensions (W×D×H, incl. hopper & blade) | 635 × 400 × 560 mm |
| Power Supply | 230 V / 50 Hz or 400 V / 50 Hz |
| Optional | ATEX-compliant explosion-proof configuration, roll heating/cooling (up to 80 °C standard, up to 100 °C on request), PFA-coated universal blade system |
| Brand | EXAKT |
|---|---|
| Origin | Germany |
| Model | 80Eplus |
| Instrument Type | Three-Roll Mill |
| Sample Compatibility | Soft, paste-like, and viscous materials (e.g., inks, paints, cosmetics, battery slurries) |
| Feed Particle Size | 5–180 µm |
| Final Output Particle Size | ≤1 µm |
| Minimum Achievable Gap | 5 µm |
| Maximum Line Pressure | 26 N/mm (gap-dependent) |
| Throughput at 10 µm Gap | 10 mL–18 L/hr |
| Roller Surface Options | Chrome-plated steel, tungsten carbide, aluminum oxide, or silicon carbide |
| Dimensions (W × D × H) | 591 × 608 × 602 mm |
| Installed Footprint Recommendation (W × D) | 1200 × 700 mm |
| Weight | 112–125 kg |
| Cooling Interface | 10 mm inlet / 13 mm outlet |
| Max Inlet Coolant Temperature | 55 °C |
| Operating Ambient Temperature | 10–30 °C |
| Power Supply Option 1 | 3 × 380–420 V / 50–60 Hz, 1300 W |
| Power Supply Option 2 | 3 × 200–240 V / 50–60 Hz, 1300 W |
| Control Interface | 8.4″ color TFT touchscreen with real-time parameter logging (gap, torque, roller temperature, motor power, time stamp) |
| Brand | EXAKT |
|---|---|
| Origin | Germany |
| Model | 80S Surface-Polished (S-Type) |
| Instrument Type | Three-Roll Mill |
| Sample Applicability | Soft Materials |
| Feed Particle Size | 5–180 µm |
| Final Output Particle Size | 1–9 µm |
| Discharge Particle Size Range | <0.01 mm |
| Batch Throughput | 10 mL–18 L/hr |
| Roll Diameter | 80 mm |
| Roll Length | 200 mm |
| Roll Speed Ratio | 9:3:1 |
| Standard Drive | Single-Speed Motor (0.3/0.45 kW) or Optional Dual-Speed Motor (1.0/1.5 kW) |
| Power Supply | AC 230 V / 50 Hz or 400 V / 50 Hz |
| Roll Temperature Control | Ambient to +80 °C (up to +100 °C on request) |
| Roll Surface Options | Hard-Chrome-Plated Stainless Steel, Anodized Aluminum, Zirconia (for 250 mm rolls only), Silicon Carbide |
| Blade Material Options | Stainless Steel, Engineering Plastic (e.g., POM), Aluminum Oxide, Zirconia |
| Optional Features | Solvent Dispenser, Explosion-Proof Design (ATEX), PFA-Coated Blade Holder, Magnetic Safety Switch on Hopper, Roll Gap Guard, Splash-Resistant Tray with Safety Interlock, Adjustable Width Retaining Plate |
| Brand | EXAKT |
|---|---|
| Origin | Germany |
| Model | 80Splus |
| Instrument Type | Three-Roll Mill |
| Sample Applicability | Hard and Brittle Materials |
| Feed Particle Size | 5–180 µm |
| Final Output Particle Size | ≤1 µm |
| Throughput Capacity | 10 mL–18 L/hr |
| Adjustable Roll Gap Range | 5–230 µm |
| Roll Material Options | Chromium-Plated Stainless Steel, Tungsten Carbide, Aluminum Oxide (Al₂O₃), Silicon Carbide (SiC) |
| Housing Material Options | Stainless Steel, Sandblasted Finish, Electropolished Finish |
| Safety Compliance | CE, Exceeds ANSI B11.19 Requirements |
| Dimensions (W × D × H) | 512 × 621 × 603 mm |
| Recommended Installation Footprint | 1200 × 700 mm |
| Weight | 112–125 kg |
| Cooling System | External Circulating Water (Inlet Ø10 mm, Outlet Ø13 mm |
| Max Inlet Temp | 55 °C |
| Operating Ambient | 10–30 °C) |
| Electrical Supply | 3 × 200–240 V / 50–60 Hz |
| Power Consumption | 1300 W |
| Brand | EXAKT |
|---|---|
| Origin | Germany |
| Model | Basic Model 50 |
| Instrument Type | Three-Roll Mill |
| Sample Applicability | Soft materials |
| Feed Particle Size | 5–180 µm |
| Final Output Particle Size | ≤5 µm |
| Throughput | 0.5 L/h |
| Minimum Output Particle Size | <0.01 mm |
| Drive Configuration | Dual-speed, adjustable timing belt (replaces V-belt) |
| Roll Dimensions | 150 mm length |
| Roll Speed Ratio | 3.3 : 1.8 : 1 |
| Roll Material | Hard-chrome-plated stainless steel or anodized aluminum |
| Blade Material Options | Stainless steel, PFA-coated, or anodized aluminum |
| Motor | Single-speed (0.12 kW) or variable-speed option (output power 0.08 kW) |
| Dimensions (W×D×H, including blade and hopper) | 320 × 280 × 320 mm |
| Electrical Supply | 230 V / 50 Hz or 400 V / 50 Hz |
| Optional Accessories | Solvent dispenser, roll-gap guard, stainless-steel hopper, PFA-coated universal blade holder, temperature-controlled rolls (cooling/heating to 80 °C standard |
| Safety Features | Magnetic safety switch on hopper, splash-resistant tray with emergency stop button, adjustable gap guard with pointer-scale indication, dust shields, IP-rated enclosure components |
| Brand | EXAKT |
|---|---|
| Origin | Germany |
| Model | E311CL |
| Instrument Type | Precision Diamond Band Saw |
| Maximum Cutting Dimensions (L×W×H) | 380 × 175 × 160 mm |
| Minimum Slice Thickness | 0.5–1.0 mm |
| Worktable Size | 400 × 400 mm |
| Max. Sample Size | 380 × 380 × 175 mm |
| Blade Speed | 10–800 m/min |
| Cutting Force Range | 1.0–8.0 N |
| Positioning Accuracy | ±0.02 mm |
| Flatness Tolerance (Load-Induced Deflection) | ±0.05 mm |
| Diamond Band Thickness | 0.3 mm |
| Cooling | Recirculating Water System |
| Dimensions (W×D×H) | 1000 × 1350 × 850 mm |
| Weight | 150 kg |
| Power Supply | 220 V, 50/60 Hz |
| Optional Accessories | Point-Contact (CP) Cutting Module, T-Slot Worktable, Mechanical Sample Clamping Fixtures |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 270 |
| Dilution Range | Up to 10,000× |
| Number of Independent Channels | 6 |
| Pressure Measurement Principle | Absolute Pressure Transducers |
| Dead Volume | Minimized via Optimized Flow Path Design |
| Tubing Material | Chemically Inert, Passivated Stainless Steel |
| Optional Module | Humidification Kit for Calibration Gas |
| Control Interface | Integrated Tablet via Wi-Fi (No External PC Required) |
| Data Management | Local Storage with Label Printing Support |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 271 |
| Sampling Principle | Negative-Pressure Passive Draw |
| Flow Range | 0.2–500 mL/min |
| Response Time for Instantaneous Retention | ≤60 s after threshold exceedance |
| Channel Configuration | Dual independent sampling channels |
| Standard Sampling Positions | 8 (expandable to 16) |
| Flow Path Treatment | Electropolished stainless steel with SilcoNert®/Sulfinert® inert coating and active heating (60–120 °C) |
| Compliance | Designed to meet HJ 759–2015 requirements for ambient VOC monitoring |
| Brand | EXPEC (Furui Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 272 |
| Sample Capacity | 16 positions standard, expandable to 48 positions (3 × 16) |
| Sample Types | Electropolished SUMMA canisters (6–30 L), gas sampling bags (Tedlar®, FlexFoil®), and crimp-top or screw-cap sampling vials |
| Flow Path | Fully inertized (SilcoNert®/Sulfinert®-treated stainless steel), heated to 110 °C ± 5 °C |
| Automation Functions | Automated leak check (pressure decay method), flow path purge & bake-out, sequence-based auto-injection |
| Compliance | Designed for EPA Method TO-14A, TO-15A, ASTM D6196, and ISO 16017-1 workflows |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 273 |
| Pump Configuration | Oil-free dual-pump system (integrated diaphragm pump + molecular turbomolecular pump) |
| Compliance | EPA Method TO-14A, TO-15A, and HJ 759-2015 |
| Control Interface | External tablet via Wi-Fi (no dedicated PC required) |
| Cleaning Modes | Dry purge, humidified rinse, heated humidified rinse |
| Vacuum Performance | ≤5 mTorr base pressure |
| Throughput | Configurable for 4-position desktop station or 8-position oven-integrated station |
| Certifications | Designed for GLP-compliant laboratories |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 274 |
| Canister Capacity | 1 L / 3 L / 6 L |
| Sampling Duration Range | 0.1–24 h |
| Flow Control Accuracy | ±2% of setpoint |
| Pressure Measurement Range | 0–30 psia, resolution 0.01 psi |
| Leak Check Sensitivity | ≤0.5 psi/min decay |
| Display | 5-inch capacitive touchscreen |
| Ingress Protection | IP56 |
| Particulate Filtration | ≥99.9% removal of particles <10 µm |
| Sample Path Surface Treatment | SilcoNert®- or Sulfinert®-equivalent deactivated passivation |
| Connectivity | Bluetooth 5.0 & Wi-Fi 802.11 b/g/n, compatible with EXPEC FieldSync mobile app (iOS/Android) |
| Data Logging | Internal non-volatile memory (≥10,000 records), CSV export via USB or cloud sync |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 510S |
| Sample Capacity Options | 9 / 16 / 36 positions |
| Heating Method | Water Bath |
| Compliance | Designed for GLP/GMP-aligned sample prep workflows |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EXPEC 520 |
| Pricing | Available Upon Request |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 530 |
| Capacity | 12-position parallel processing |
| Endpoint Detection | Auto-sensing nitrogen blowdown termination |
| Final Volume Options | 0.5 mL or 1.0 mL (user-selectable) |
| Visual Monitoring | Triple-sided tempered glass viewport with integrated LED illumination |
| Sample Tube Compatibility | 80 mL and 300 mL tubes |
| Optional Feature | Wall-rinse module for solvent-assisted recovery enhancement |
| Safety Design | Fully enclosed water bath chamber with internal exhaust fan and dedicated vent ducting |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Model | EXPEC 550 |
| Extraction Vessel Capacity | 10–60 mL |
| Operating Pressure Range | Up to 20 MPa |
| Temperature Range | Ambient to 200 °C |
| Cycle Time per Sample | 15–30 min |
| Solvent Consumption | Reduced by ≥70% vs. Soxhlet |
| Safety Compliance | Integrated Leak Detection, Over-Pressure & Over-Temperature Interlocks, Method Validation Alert System |
| Heating Jacket Surface Temp | <50 °C |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 560 |
| Throughput | Up to 36 samples per batch |
| Drive Type | Brushless DC motor with variable-speed control |
| Homogenization Motion | Vertical reciprocating + rotational motion |
| Cleaning Modes | Aqueous rinse, organic solvent rinse, ultrasonic-assisted cleaning |
| Enclosure | Full-integrated transparent safety door with interlock |
| Safety Compliance | CE-marked per EN 61000-6-2/6-4 and EN 61000-3-2/3-3 |
| Software Interface | Touchscreen HMI with method storage, real-time status monitoring, and fault logging |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Model | EXPEC 570 |
| Configuration Options | 2-, 6-, 8-channel & PFA-dedicated variants |
| Origin | Zhejiang, China |
| System Architecture | Integrated touchscreen-controlled platform with internal waste segregation |
| Sample Throughput | Batch-mode processing for up to 8 samples simultaneously (model-dependent) |
| Flow Control | Precision syringe-pump-driven elution with column-seal plug design |
| Compatibility | Standard 1 mL–6 mL SPE cartridges (C18, HLB, Florisil, SAX, SCX, PFA-lined, etc.) |
| Optional Modules | Large-volume aqueous sample enrichment (>500 mL), custom cartridge adapters, GLP-compliant audit trail upgrade |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 750 |
| Flow Rate Range | 0.5–600 mL/min |
| Channel Capacity | 6 parallel channels |
| Operation Modes | Fully automated activation, sample loading, washing, and elution with programmable sequence editing |
| Sample Processing Time | 10–20 min per batch |
| Compatibility | Integrated interface for AFS, ICP-OES, and ICP-MS instrumentation |
| Column Type | Pressure-rated separation column with closed-loop fluidic control |
| Precision Feature | Automatic final volume adjustment (auto-dilution/evaporation compensation) |
| Regulatory Context | Designed to support GLP-compliant workflows and traceable sample preparation under ISO/IEC 17025 laboratory accreditation requirements |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 760 |
| Balance Options | 0.01 mg (10 µg) or 0.1 mg resolution |
| Anti-static Ionizer | Integrated dual-nozzle air ionization system |
| Robotic Arm | 4-axis articulated robot with ±0.05 mm repeatability |
| Vibration Isolation | Triple-stage passive damping platform |
| Weighing Enclosure Control | Motorized draft shield door actuation synchronized with weighing cycle |
| Sample Tube Handling | Barcode-scanned vial identification, automated cap removal/placement in dedicated sterile zone |
| Data Output | CSV/Excel export, audit-trail-enabled database logging compliant with GLP requirements |
| Compliance | Designed to support ISO/IEC 17025 workflows and FDA 21 CFR Part 11–ready data integrity architecture |
| Brand | EXPEC (Hangzhou Puyu Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 780 |
| Heating Block Material | High-Purity Graphite |
| Automation Level | Full Unattended Operation |
| Acid Resistance | PTFE/PFA-Wetted Components Compatible with HNO₃, HCl, HF, and HClO₄ |
| Temperature Control | PID-Controlled Distributed Heating |
| Temperature Range | Ambient to 230 °C |
| Sample Capacity | Up to 48 Positions (Configurable) |
| Acid Addition | Six Independent Peristaltic Pumps + Precision Syringe Pump for Spiking |
| Lid Handling | Motorized Lid Sealing/Unsealing with Condensation-Optimized Design |
| Volume Accuracy | <1% RSD at 50 mL (Ultrasonic Level Sensing) |
| Volume Range | 5–50 mL |
| Mixing Method | Pneumatic Bubble Agitation |
| Sample Transfer | Integrated Robotic Arm to Autosampler Tray |
| Exhaust System | Dedicated Acid-Fume Extraction with Corrosion-Resistant Ducting |
| Compliance | Designed for GLP/GMP Environments |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 790F |
| Maximum Operating Temperature | 300 °C |
| Maximum Operating Pressure | 20 MPa |
| Safety Vessel Rating | 30 MPa |
| Digestion Cavity | Single-zone, uniform temperature/pressure |
| Sample Capacity | Up to 96 samples per batch (configurable rotor: 6/8/18/24 positions) |
| Acid Volume Range | 2–3 mL per sample |
| Final Volume Accuracy | <1% RSD at 50 mL (5–50 mL range) |
| Reagent Delivery | PTFE-lined peristaltic pumps & precision syringe pump |
| Filtration | Auto-replacement disposable filter cartridges |
| Interface | ICP-OES/ICP-MS direct coupling support |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EXPEC 790S |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FAAS 8000 |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pre 3900 |
| Pricing | Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pre 4000 |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pre 4100 |
| Pricing | Available Upon Request |