Constant Temp/Heating/Drying Equipment
Filter
Showing 661–690 of 948 results
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | PP 40/85 |
| Furnace Type | Benchtop/Industrial Box Furnace |
| Max Temperature | 850°C |
| Temperature Uniformity | ±2°C (per DIN 17052-1) |
| Heating Method | Resistive Wire (NiCr) |
| Internal Dimensions | 300 × 200 × 350 mm (W×H×D) |
| Volume | 21 L |
| Power Rating | 4 kW |
| Ramp Time to 850°C | ≤20 min |
| Insulation | Mineral Fiber (High-Density Ceramic Wool) |
| Controller | HT40AL Programmable Controller (30 programs, 15 segments each) |
| Thermocouple | K-Type |
| Safety Features | Door-Interlocked Terminal Switch, Overtemperature Cut-off |
| Construction | Low-Carbon Steel Outer Casing, AISI 304 Stainless Steel Chamber |
| Air Circulation | Horizontal Forced-Air System with Rear-Mounted Fan Assembly |
| Voltage | 230 V AC, 50/60 Hz |
| Weight | 130 kg |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Alpha |
| Instrument Type | Circulating Bath |
| Temperature Range | -25 to 100 °C |
| Temperature Stability | ±0.05 K |
| Bath Volume Options | 7.5 L – 22 L |
| Circulation Mode | Internal & External |
| Compatible Fluids | Water, Water/Glycol (non-flammable only) |
| Compressor Power | Up to 0.425 kW |
| Pump Flow Rate | Adjustable from 5 to 15 L/min |
| User Calibration | Single-point temperature calibration supported |
| Enclosure Access | Tool-free front panel removal for condenser maintenance |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Aqualine |
| Instrument Type | Circulating Constant-Temperature Bath |
| Circulation Mode | Internal & External |
| Temperature Control | Heating & Cooling |
| Bath Volume Range | 1.7 L to 25.2 L |
| Temperature Range | 25 °C to 95 °C |
| Temperature Stability | ±0.2 K |
| Construction | Seamless Deep-Drawn Stainless Steel |
| Heating Element | Bottom-Mounted Surface Heater |
| Safety Features | Dry-run Protection (Min. Liquid Level: 20 mm), Over-Temperature Alarm |
| Display | LED Digital Interface |
| Lid Design | Hinged Stainless Steel Roof Lid with Condensate-Prevention Geometry |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | ECO Silver / ECO Gold |
| Temperature Range | 20–200 °C |
| Display | Monochrome Graphical LCD (ECO Silver) or Color TFT LCD (ECO Gold) |
| Safety Class | Class III |
| Control Principle | Digital PID |
| Pump Type | Vario adjustable 6-stage circulation pump |
| Interface | Standard USB |
| Optional modules | Analog, Relay, RS232/485, PROFIBUS, Ethernet-USB, Pt100/LiBus |
| Mounting | Threaded clamp for baths with wall thickness ≤25 mm and depth ≥150 mm |
| Compliance | Suitable for flammable and non-flammable liquids |
| Certifications | CE, RoHS, IEC 61010-1 |
| Key | Brand: LAUDA |
|---|---|
| Origin | Germany |
| Type | Circulating Bath (Heating & Cooling) |
| Temperature Range | –50 °C to +200 °C (model-dependent) |
| Temperature Stability | ±0.01 K |
| Bath Volume | 3.5 L to 40 L |
| Circulation | Internal & External |
| Cooling Power | 180–700 W @ 20 °C |
| Controller Options | Silver (monochrome LCD) or Gold (color TFT) |
| Pump | 6-stage adjustable flow, front-mounted flow selector switch |
| Standard Interfaces | Mini-USB |
| Optional Modules | RS232/485, Profibus, Ethernet, EtherCAT, analog I/O, Pt100 L-Bus |
| Cooling Method | Air-cooled or water-cooled variants available |
| Refrigerant | Environmentally optimized natural refrigerants (e.g., R744, R290) compliant with F-Gas Regulation (EU) No 517/2014 |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Ecoline Star Edition |
| Temperature Control Type | Refrigerated/Heating Circulating Bath |
| Circulation Mode | Internal & External |
| Application | Primary Reference Standard for Thermometer and Sensor Calibration |
| Temperature Stability | ±0.01 °C (typical, dependent on model and operating conditions) |
| Temperature Range | –40 °C to +300 °C (model-dependent) |
| Bath Volume | 12–54 L |
| Pump Flow Rate | 12–25 L/min |
| Maximum Pump Pressure | 0.2–0.8 bar |
| Heating Power | 1.2–3.5 kW |
| Compliance | Designed for DKD/DAkkS-accredited calibration laboratories |
| Software Interface | RS232/RS485, optional Ethernet (via LAUDA TC software suite) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Integral P |
| Temperature Range | -40 to +140 °C |
| Heat Transfer Fluid | Non-flammable water/ethylene glycol mixture |
| Max Operating Pressure | 4 bar (gauge) |
| Pump Type | Magnetically coupled, electronically controlled |
| Flow Rate | Adjustable per application |
| Compatible Controller | LAUDA MID 80 Flow Control Unit |
| Application Focus | Automotive, Aerospace, EV Battery Thermal Testing |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | T1200 |
| Temperature Range | −25 °C to +120 °C |
| Temperature Stability | ±0.2 °C |
| Heating Power | 2.25 kW |
| Cooling Capacity at 20 °C | 1.2 kW |
| Pump Flow Rate | 40 L/min |
| Maximum Pump Pressure | 3.2 bar |
| Bath Volume | 7 L |
| Dimensions (W×D×H) | 450 × 550 × 790 mm |
| Cooling Type | Air-Cooled |
| Circulation Mode | Internal & External Dual Loop |
| Control System | Microprocessor-Based with Programmable Ramp-Soak Profiles (5 Programs, 150 Segments) |
| Display | Dual-Line LCD (Setpoint & Actual Temperature) |
| External Sensor Input | Pt100 Compatible for Remote Temperature Control |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Integral XT |
| Type | Circulating Bath Chiller/Heater |
| Temperature Range | −50 °C to +300 °C |
| Temperature Stability | ±0.05 °C (typical) |
| Heating Power | up to 10.4 kW |
| Cooling Capacity at 20 °C | up to 18.5 kW |
| Pump Flow Rate | up to 90 L/min |
| Max. Pump Pressure | 5.8 bar |
| Reservoir Volume | 5.5–17.4 L |
| Cooling Method | Air-cooled or Water-cooled |
| Control Interface | Graphical LCD with detachable remote controller |
| Communication | RS-232/RS-485 standard, optional Ethernet/Modbus/Profibus modules |
| Compliance | CE, UL, ATEX optional |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | KHS 3560 W / KHS 2190 W |
| Temperature Range | –90 °C to +200 °C |
| Refrigeration System | Dual-stage compressor (down to –60 °C) or cascade refrigeration (down to –90 °C) |
| Cooling Method | External water-cooled condenser |
| Expansion Control | Stepper-motor-driven electronic expansion valve |
| Pressure Rating | Designed for pressurized operation with nitrogen (up to 6 bar typical, per system configuration) |
| Application Environment | Industrial process simulation, pharmaceutical synthesis, chemical R&D, automotive & aerospace environmental testing |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | LOOP |
| Temperature Range | 4–80 °C |
| Cooling Power | 120 W (L 100), 250 W (L 250) |
| Input Voltage | 100–240 V AC, 50/60 Hz |
| Cooling Method | Refrigerant-free air-cooled system |
| Fluid Compatibility | Non-flammable liquids (e.g., water, water/ethylene glycol mixtures) |
| Display | High-contrast graphical OLED |
| Interface | RS232 |
| User Interface | 3-key soft-touch control |
| Pump Connection | Quick-release fittings |
| Noise Level | Low (typ. <45 dB(A) at partial load) |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | PRO P10 |
| Bath Volume | 10–28.5 L |
| Temperature Range | 30 °C to 250 °C |
| Temperature Stability | ±0.01 K |
| Circulation Type | Internal & External |
| Standard Interfaces | USB, Ethernet |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | PRO P2E |
| Instrument Type | Circulating Temperature Control Bath |
| Circulation Mode | Internal & External |
| Temperature Control | Refrigeration & Heating |
| Bath Volume | 4.4 L |
| Temperature Range | −40 °C to +250 °C |
| Temperature Stability | ±0.05 K |
| Interface Standard | USB, Ethernet, Pt100 |
| Pump Type | Varioflex® High-Performance Pressure/Draw Pump |
| Cooling Method | Hybrid (Ambient Air + Optional Water-Cooled Condenser) |
| Refrigeration Capacity | 0.6 kW / 0.8 kW (model-dependent) |
| Max. Remote Control Distance | 50 m |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | RP 290 EC |
| Temperature Range | –90 to 200 °C |
| Cooling Output | 0.6 kW / 0.8 kW (dual-stage) |
| Internal Volume | 2.4–4.4 L |
| Pump Type | LAUDA Varioflex (pressure/suction, 8-step adjustable) |
| Max Flow Rate | 22 L/min (pressure), 20 L/min (suction) |
| Max Pressure | 0.7 bar |
| Max Suction | 0.4 bar |
| Heating Power | 2.5 kW |
| Max Power Consumption | 3.7 kW |
| Temp Stability | ±0.05 K |
| Display | 5.7″ multi-touch color screen |
| Connectivity | USB, Ethernet, RS-232/485, Profibus, EtherCAT, analog/digital I/O |
| Compliance | DIN 12876, EU F-Gas Regulation (EU) No. 517/2014, RoHS |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Proline Thermostats |
| Temperature Range | -90 °C to +200 °C |
| Temperature Stability | ±0.01 °C (typ. at 20 °C) |
| Heating Power | 3.5 kW |
| Refrigeration Power (at 20 °C) | up to 1.6 kW |
| Pump Pressure | 0.7 bar |
| Suction Head | 0.4 bar |
| Pressure Flow Rate | 25 L/min |
| Suction Flow Rate | 23 L/min |
| Bath Volume | 8–35 L |
| Bath Opening Dimensions | 150×150 mm to 300×350 mm |
| Depth | 200–250 mm |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Proline PJ12 / PJ12 C / PJL12 / PJL12 C |
| Temperature Range | –40 °C to +300 °C |
| Heating/Cooling Medium | Liquid (e.g., silicone oil, water-glycol) |
| Control System | Microprocessor-based PID with PowerAdapt and SelfCheck diagnostics |
| Pump Type | LAUDA Varioflex pressure pump (8 adjustable levels) |
| Display | Green LED, EasyUse 3-button interface |
| Communication Interfaces | RS-232/485, Profibus, analog/contact modules, Ethernet/USB (optional) |
| Safety Features | Dual-stage overtemperature protection, audible alarm, flammable/non-flammable liquid mode |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Proline |
| Type | Circulating Bath (Heating-Only) |
| Temperature Range | -35 °C to +300 °C |
| Temperature Stability | ±0.01 °C |
| Heating Power | 3.5 kW |
| Pump Type | Variable-Speed Centrifugal |
| Max. Pressure Head | 0.7 bar |
| Max. Suction Head | 0.4 bar |
| Flow Rate (Pressure) | up to 25 L/min |
| Flow Rate (Suction) | up to 23 L/min |
| Bath Volume | 5.5–27.0 L |
| Bath Opening Dimensions | 150×50 mm to 300×350 mm |
| Depth | 200–320 mm |
| External Circulation | Dual-port (rear & side) |
| Sensor Input | External PT100 support |
| Safety | Triple-heater redundancy, overtemperature cutoff, dry-run protection, leak detection, error-code display |
| Interface | 3-button intuitive control panel |
| Expandability | Modular slot for optional accessories (e.g., refrigeration, communication modules) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Proline Kryomate |
| Temperature Range | –90 °C to +200 °C |
| Bath Volume | 30 L or 40 L |
| Cooling Method | Air-Cooled (e.g., RP 4050 C, RP 3090 C, RP 4090 C) or Water-Cooled (e.g., RP 4050 CW, RP 3090 CW, RP 4090 CW) |
| Pump Pressure Control | 4-Stage Adjustable |
| Display | Backlit Graphical LCD with High-Resolution Interface + Dedicated Green LED Temperature Display |
| Control Interface | Cursor Keys, Soft Numeric Keypad, Tmax Override Key |
| Remote Operation | Detachable LAUDA Command Console |
| Control Algorithm | Fully Electronic PID Controller (Internal & External Loop) |
| Condensation Mitigation | Integrated Rim & Bridge Heating |
| Self-Diagnostic Function | Built-in System Check Assistant |
| Compliance | Designed for GLP/GMP-aligned laboratory environments |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Type | Refrigerated/Heating Circulating Bath |
| Temperature Range | −90 °C to +200 °C |
| Temperature Stability | ±0.01 °C (at 20 °C, depending on model and load) |
| Bath Volume | 5.5–35 L |
| Pump Flow Rate | Up to 25 L/min (pressure), 23 L/min (suction) |
| Pump Pressure Head | Up to 1.1 bar |
| Heating Power | 3.5 kW |
| Refrigeration Power | 0.38–1.6 kW (model-dependent) |
| Control Interface | Command or Master Controller |
| Circulation | Internal & External |
| Safety Features | Dual-level liquid level detection, overtemperature/overpressure/low-fluid alarms, dry-run protection, integrated error logging |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Proline-X |
| Type | Circulating Temperature Bath |
| Temperature Range | -90 °C to +200 °C |
| Temperature Stability | ±0.01 °C |
| Heating Power | 3.5 kW |
| Pump Pressure Head | 0.7–1.1 bar |
| Pressure Pump Flow Rate | 25 L/min |
| Suction Pump Flow Rate | up to 23 L/min |
| Bath Volume Options | 15 L, 24 L, 36 L, or custom external bath compatibility (310–500 mm width) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | RA8 |
| Temperature Range | -25 °C to +85 °C |
| Temperature Stability | ±0.05 °C |
| Heating Power | 1.5 kW |
| Cooling Capacity (at 20 °C) | 0.225 kW |
| Pump Pressure | 0.2 bar |
| Pump Flow Rate | 15 L/min (adjustable between 5–15 L/min) |
| Bath Volume | 5–7.5 L |
| Opening Dimensions × Depth | 165 × 190 × 160 mm |
| Construction | Stainless Steel Bath Chamber |
| Control Interface | 3-button LED Display |
| Circulation Type | Internal & External |
| Temperature Control Mode | Dual-mode (Heating & Refrigeration) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Semistat S1200 / S2400 / S4400 |
| Temperature Range | −20 to +90 °C |
| Control Stability | ±0.1 K |
| Cooling Principle | Solid-State Peltier (Thermoelectric) |
| Fluid Volume | Minimal (Typ. < 1.5 L) |
| Footprint | Floor-Mountable or Sub-Fab Integrated |
| Energy Consumption | Up to 90% Lower vs. Compressor-Based Systems |
| Compliance | Designed for ISO Class 1–5 Cleanroom Integration |
| Application Focus | Electrostatic Chuck (ESC) Thermal Management in Plasma Etch Tools |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Ultracool |
| Type | Refrigerated/Heating Recirculating Chiller |
| Circulation Mode | Internal & External |
| Temperature Range | 0–100 °C |
| Temperature Stability | ±0.1 °C (typical, dependent on load and ambient conditions) |
| Refrigerant | Low-GWP hydrofluoroolefin (HFO-1234ze, GWP < 250) |
| Enclosure Rating | IP54 |
| Max Ambient Operating Temperature | 50 °C |
| Construction | Electroplated copper housing with epoxy resin coating |
| Reservoir Material | Insulated polyethylene tank with integrated level switch |
| Heat Exchanger | External plate-type evaporator |
| Pump | High-efficiency stainless steel centrifugal pump with internal bypass |
| Safety Features | Freeze-protection thermostat, pressure monitoring switch, integrated water filter with biostatic additive |
| Optional Configurations | Stainless steel enclosure, casters, external bypass valve, deionized water compatibility, air-cooled or water-cooled condenser variants |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Variocool |
| Cooling Capacity | Up to 10 kW |
| Temperature Range | –20 °C to +40 °C (–20 °C to +80 °C with optional heating module) |
| Temperature Stability | ±0.2 K |
| Max. Pump Pressure | 3.2 bar |
| Max. Flow Rate | 37 L/min |
| Power Supply Options | 208–230 V, 50/60 Hz |
| Optional Modules | Boost Pump, Water-Cooled Condenser, Flow Control, Low-Noise Kit, Outdoor Installation Kit |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XT 150 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LS 12/13 and LS 25/13 |
| Quotation | Upon Request |
| Max Temperature | 1300 °C |
| Internal Dimensions (W×D×H) | LS 12/13: 350 × 350 × 40 mm |
| LS 25/13 | 500 × 500 × 100 mm |
| Chamber Volume | 12 L and 25 L |
| External Dimensions (W×D×H) | LS 12/13: 600 × 800 × 985 mm |
| LS 25/13 | 750 × 985 × 1150 mm |
| Power Connection | 3-phase |
| Rated Power | 15 kW (LS 12/13), 22 kW (LS 25/13) |
| Net Weight | 130 kg (LS 12/13), 160 kg (LS 25/13) |
| Heating Zones | Dual-zone (bottom + top) |
| Thermocouple Type | Integrated S-type PtRh10%–Pt |
| Cooling | Built-in programmable axial fan + motorized lid lift (~20 mm) |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Model | 131-1010 |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ±0.3°C |
| Heating Time (20°C → 100°C) | ≤18 min |
| Dimensions (L×W×H) | 160×110×136 mm |
| Net Weight | ≤1 kg |
| Power Supply | 12 V DC |
| Max Power | 60 W |
| Display Resolution | 0.1°C |
| Timer Range | 0–99 h / 0–99 min / 0–99 s |
| Temperature Stability | ±0.3°C at 40°C and 100°C |
| Module Compatibility | M1–M8 interchangeable blocks |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Model | 131-1020 |
| Temperature Range | Ambient +5°C to 105°C |
| Temperature Accuracy | ±0.3°C |
| Heating Time | ≤10 min (20°C to 105°C) |
| Dimensions | 176 × 160 × 121 mm |
| Net Weight | 1.5 kg |
| Display Resolution | 0.1°C |
| Max Power | 150 W |
| Timer Range | 0–99 h 59 min |
| Temperature Stability | ±0.3°C at 40°C and ±0.3°C at 100°C |
| Standard Module | C3 (39 × 1.5 mL tubes) |
| Optional Modules | C1 (96 × 0.2 mL), C2 (58 × 0.5 mL), C4 (39 × 2.0 mL), C5 (18 × 5.0 mL), C6 (24 × 0.5 mL + 30 × 1.5 mL), C7 (58 × 6 mm tubes) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MKG-M1UB |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Tube Furnace |
| Maximum Temperature | 0–1000 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 1300 W |
| Heating Rate to Max Temp | ≤30 min |
| Heating Method | 2450 MHz Continuous Non-Pulsed Microwave |
| Internal Chamber Dimensions | 100 × 100 mm (Crucible System) |
| Microwave Cavity Volume | ~1.2 L |
| Microwave Output Power | 800 W (Adjustable, 0–100%) |
| Atmosphere Compatibility | Inert, Reducing, Oxidizing (via Optional Gas Lines) |
| Safety Leakage | <5 mW/cm² (per GB 10436 & IEC 61000-3-2) |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model | CTC/TTC 256 |
| Temperature Range | –42 °C to +190 °C (dry operation) |
| Humidity Range | 10–98 %RH (CTC models only) |
| Compliance | DIN EN 60068-2-1, -2-2, -2-3 |
| Insulation | Triple-layer aerospace-grade vacuum-insulated walls |
| Refrigeration | Dual parallel compressors with electronic refrigerant metering |
| Defrost | Automatic hot-gas defrost system |
| Construction | Stainless steel evaporator, corrosion-resistant interior |
| Noise Level | <62 dB(A) at 1 m |
| Cooling/Heating Rate | ~–40 °C in 80 min from +180 °C |