| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model | HCP |
| Temperature Range | Up to 190 °C |
| Humidity Range | 10–98 % RH |
| Uniformity | ±0.3 °C (temp), ±1.5 % RH (humidity) |
| Chamber Volume Options | 23–1100 L |
| Compliance | IEC 60068-2-67, IEC 60068-2-78, ASTM D4332, ISO 188, USP <1151>, ICH Q1A(R2) |
| Standard Features | Six-Side Heating, Glass Inner Door with Integrated Heating, Dynamic Humidity Control, AtmoCONTROL Software, Validation Ports (rear-mounted), SetpointWAIT Function |
| Optional | UPS Integration, Email/SMS Alarm Notification, GLP/GMP Audit Trail Module |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model Variants | HPPeco 110 / 260 / 410 / 750 / 1060 / 1400 / 2200 |
| Temperature Range | 0 °C to +70 °C |
| Humidity Range | 10–90 % RH (dynamic humidification & dehumidification) |
| Cooling Technology | Solid-state thermoelectric (Peltier) |
| Compliance | ICH Q1A(R3), ISO 14644-1 (Class 8 ambient compatibility), GLP-ready |
| Optional | Adjustable LED Illumination Module (2,700 K / 6,500 K / dual-spectrum, 1–100 % intensity stepwise control) |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Model | ICH Series |
| Temperature Uniformity | ≤ ±0.1 °C (at 25 °C, empty) |
| Humidity Range | 10–80 % RH (±1 % RH accuracy) |
| Air Circulation | Forced convection, adjustable in 10 % increments |
| Refrigerant | R744 (CO₂, GWP = 1) |
| Light Module | ICH Q1B Option 2 compliant — D65 daylight source (6500 K, ~8000 lux) + UV-A (320–400 nm) |
| CO₂ Control Module (optional) | IR-based, auto-zeroing, pressure-compensated, frost-free operation |
| IQ/OQ/PQ Support | Predefined calibration points — 3 temp setpoints, 2 humidity setpoints (20 % & 80 % RH), 3 CO₂ levels (5 %, 10 %, 15 %) |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model Variants | ICO 50 / ICO 105 / ICO 150 / ICO 240 |
| Temperature Range | +18 °C to +50 °C |
| Humidity Range | 40–97 % RH (optional) |
| CO₂ Concentration Range | 0–20 % |
| O₂ Concentration Range | 1–20 % (optional) |
| Sterilization | Dry-heat at 180 °C for 60 min |
| Data Storage | Internal SD card (10-year capacity) |
| Compliance | FDA 21 CFR Part 11–ready, GLP/GMP-supportive architecture |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model Variants | ICP 110 / ICP 260 / ICP 450 / ICP 750 |
| Temperature Range | –12 °C to +60 °C |
| Cooling System | Hermetically Sealed Refrigeration Compressor |
| Heating System | Air-Jacketed (Gas-Heated) |
| Interior Volume | 110–750 L (Model-Dependent) |
| Temperature Uniformity | ±0.3 °C at 37 °C (typical, per DIN 12880) |
| Airflow Control | Adjustable Fan Speed in 10% Increments via Touchscreen Interface |
| Illumination Option | Programmable Day/Night Cycle with Simulated Photoperiod and Associated Thermal/Fan Profiles |
| Defrost Mode | Automatic, Energy-Optimized Cycle |
| Energy Efficiency | Optimized Compressor Duty Cycling + Adaptive Heating/Cooldown Logic |
| Compliance | Designed to Support GLP/GMP Environments |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model | IFbw |
| Heating Configuration | Quadruple-wall heating with independent temperature monitoring |
| Airflow Control | Adjustable fan speed in 10% increments (0–100%) |
| Fresh Air Preheating System | Integrated preheat chamber for incoming ambient air |
| Internal Airflow | Minimized forced convection to prevent surface desiccation |
| Compliance | Designed for GLP-compliant environments |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model | IN / IF Series |
| Temperature Range | Ambient +5°C to +80°C |
| Convection Type | Natural Convection (IN) / Adjustable-Speed Forced Convection (IF) |
| Sterilization Capability | 160°C for 4 h (INplus/IFplus models) |
| Fresh Air Preheating System | Integrated preheating chamber |
| Compliance | Designed for GLP/GMP environments, supports FDA 21 CFR Part 11–compliant software validation (with optional VarioControl software) |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model Range | IPPeco 110 / 260 / 400 / 750 / 1060 / 1400 / 2200 |
| Temperature Range | 0 °C to +70 °C |
| Cooling Technology | Solid-State Peltier Modules |
| Heating Method | Precision Resistive Heating |
| Energy Efficiency | Up to 90% Lower Power Consumption vs. Compressor-Based Systems |
| Vibration Level | <0.5 µm RMS |
| Noise Emission | ≤38 dB(A) |
| Internal Air Circulation | Forced Convection with Optimized Flow Path |
| Condensation Management | Externalized Condensate Formation |
| Humidity Compatibility | Not Integrated (Use HPPeco Series for Humidity Control) |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model | SN/SF |
| Compliance | EU MDD 93/42/EEC Class IIa |
| Sterilization Method | Dry Heat |
| SetpointWAIT Function | Yes |
| Optional Features | Pt100 Sample Probe (movable), Electromagnetic Door Lock, ID Card Access Control, TwinDISPLAY Interface, 4–20 mA Output, GLP/GMP-Ready Data Logging |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model Series | UF 30 / UF 55 / UF 75 / UF 110 / UF 160 / UF 260 / UF 450 / UF 750 / UF 1060 |
| Temperature Range | +20 °C to +300 °C |
| Control System | PID microprocessor with integrated self-diagnosis |
| Construction | Stainless steel exterior (AISI 304), galvanized stainless steel rear panel |
| Power Interface | High-temperature-rated IEC-compliant rear power inlet |
| Data Storage | Internal memory card retaining ≥10 years of temperature log data |
| Display & Interface | ControICOCKPIT multi-language touchscreen (English, German, French, Spanish) |
| Timer Functionality | Digital countdown timer adjustable from 1 min to 99 days |
| Calibration | On-screen three-point temperature calibration (via Pt100 reference input) |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model | UF TS |
| Type | Industrial Through-Circulation Forced-Air Oven |
| Compliance | CE, ISO 17025-compatible operation environment, designed for GLP/GMP-aligned thermal processing |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model Series | UN30, UN55, UN75, UN110, UN160, UN260, UN450, UN750, UN1060 / UF30, UF55, UF75, UF110, UF160, UF260, UF450, UF750, UF1060 |
| Temperature Range | +20 °C to +300 °C |
| Convection Options | Natural Convection (UN series) or Forced Convection with Adjustable Airflow (UF & UFplus series) |
| Air Exchange Control | Motorized damper with programmable opening angle (UFplus only) |
| Fresh Air Preheating | Integrated preheating chamber for incoming ambient air |
| Safety Certification | Complies with EN 61010-1, IEC 61000-6-3, and applicable parts of ISO 13485 when configured with A6 High-Temperature Alarm Module |
| Regulatory Use | Validated for sterilization of microbiological textiles and wrapping materials (per DIN EN ISO 17665-1 and DIN EN 285 when equipped with A6 module and operated within validated parameters) |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Model Series | UNpa 30 / UNpa 55 / UNpa 75 / UNpa 110 / UNpa 160 |
| Temperature Range | +20 °C to +80 °C |
| Chamber Volume | 30 L / 55 L / 75 L / 110 L / 160 L |
| Heating Principle | Quadruple-wall conduction heating with passive thermal homogenization |
| Safety | Dual independent overtemperature protection (mechanical + electronic), hermetically sealed chamber design |
| Compliance | IEC 61010-1, EN 61326-1 (EMC), CE-marked for laboratory use |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model | VO 29 / VO 49 / VO 101 |
| Temperature Range | +20 °C to +200 °C |
| Vacuum Range | 2 mbar to 1100 mbar |
| Heating Method | Direct plate heating with integrated Pt100 sensors |
| Control System | ControlCOCKPIT touchscreen interface + AtmoCONTROL software |
| Vacuum Pump Compatibility | Memmert chemically resistant diaphragm vacuum pump (optional, auto-synchronized) |
| Compliance | CE, ISO 17025-compatible operation, GLP/GMP-ready audit trail support |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | VO200 |
| Instrument Type | Vacuum Oven |
| Temperature Range | +20 °C to +200 °C |
| Temperature Uniformity (at 160 °C / 50 mbar) | ≤ ±5 °C (on shelf surface) |
| Temperature Stability | ±0.3 °C (per DIN 12880) |
| Chamber Volume | ~29 L |
| Internal Dimensions (W×H×D) | 385 × 305 × 205 mm |
| External Dimensions (W×H×D) | 550 × 600 × 400 mm |
| Shelf Capacity | Up to 3 stainless steel shelves |
| Shelf Spacing | 75 mm |
| Max Load per Shelf | 20 kg |
| Max Total Load | 40 kg |
| Chamber Material | Electropolished AISI 316L stainless steel (EN 1.4404 / ASTM A240) |
| Outer Casing | Textured stainless steel with galvanized steel rear panel |
| Heating System | Direct-backplate MLC (Multi-Level Control) resistive heating elements integrated into each shelf |
| Temperature Sensing | Pt100 Class A, 4-wire, per-shelf independent probes |
| Vacuum Control | Digital electromagnetic valve with programmable setpoint range 5–1100 mbar (display resolution 1 mbar) |
| Gas Inlets | Two digitally controlled, programmable inlets (air + optional process gas) |
| Pressure Regulation | Closed-loop digital pressure control with real-time feedback |
| Safety Systems | Dual independent overtemperature protection (MLOP + mechanical TB), ASF (Automatic Setpoint Linking), microprocessor-based fault diagnostics with audible/visual alarms |
| Programming | Up to 40 temperature–vacuum profiles |
| Compliance | Designed and manufactured in accordance with EN 61010-1, EN 61000-6-3, EN 61000-6-4, and meets essential requirements of EU Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model | VO29 / VO49 / VO101 |
| Instrument Type | Vacuum Oven |
| Temperature Range | +5 °C above ambient to 200 °C |
| Temperature Stability | ≤ ±0.3 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Vacuum Control Range | 5–1100 mbar |
| Ultimate Vacuum | ≤2 mbar |
| Chamber Dimensions (W×D×H) | 340×340×250 mm (VO29), 420×420×280 mm (VO49), 520×520×370 mm (VO101) |
| External Dimensions (W×D×H) | 520×625×645 mm (VO29), 620×725×745 mm (VO49), 720×825×845 mm (VO101) |
| Chamber Material | Stainless Steel (AISI 304) |
| Heating Method | Direct Shelf Heating |
| Operating Ambient Temperature | 5–40 °C |
| Shelf Interfaces | 1 (VO29), 2 (VO49 & VO101) |
| Safety Features | Over-/Under-Temperature Protection, Acoustic/Visual Alarm, Explosion-Resistant Door, Integrated Fault Diagnosis System |
| Connectivity | Ethernet, USB, Dual TFT Color Displays |
| Software | AtmoCONTROL (via USB stick or network) |
| Compliance | Designed for GLP/GMP environments |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | VO400 |
| Instrument Type | Vacuum Oven |
| Temperature Range | +20 to +200 °C |
| Internal Chamber Dimensions (W×H×D) | 385 × 385 × 330 mm |
| External Dimensions (W×H×D) | 710 × 760 × 550 mm |
| Chamber Material | Electropolished Stainless Steel 1.4404 (ASTM 316L) |
| Heating Method | Internal Radiant Plate Heating with Forced Convection |
| Vacuum Control Range | 5–1100 mbar (digital electromagnetic valve control) |
| Max. Shelf Capacity | 4 adjustable shelves (75 mm spacing) |
| Load per Shelf | 20 kg |
| Total Load Capacity | 60 kg |
| Temperature Uniformity at 160 °C / 50 mbar | ≤ ±5 K (surface) |
| Temperature Stability (DIN 12880) | ≤ ±0.3 K |
| Sensor System | Individual Pt100 Class A (4-wire) per shelf, integrated MLC (Multi-Level Control) architecture |
| Safety Features | Dual independent overtemperature protection (electronic ASF + mechanical TB), door-interlocked rapid venting, leak rate ≤ 0.01 bar/h, residual vacuum ≤ 0.01 mbar |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | VO500 |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient + 5 °C to 200 °C |
| Temperature Uniformity (at 160 °C / 50 mbar) | ≤ ±5 °C (surface) |
| Temperature Stability | ±0.3 °C |
| Chamber Dimensions (W×H×D) | 545 × 465 × 400 mm |
| External Dimensions (W×H×D) | 710 × 760 × 550 mm |
| Chamber Volume | ~101 L |
| Interior Material | Electropolished Stainless Steel 1.4404 (ASTM 316L) |
| Exterior Material | Textured Stainless Steel with Galvanized Steel Back Panel |
| Heating Method | Internal Multi-Level Control (MLC) with Direct-Attached PTC Heating Elements on Perforated Stainless Steel Shelves |
| Shelf Configuration | Up to 4 Adjustable Shelves (95 mm spacing), Load Capacity: 20 kg/shelf (60 kg total) |
| Vacuum Control | Digital Electromagnetic Valve, Adjustable Range: 5–1100 mbar (displayed), Programmable Setpoint from 10–1100 mbar |
| Pressure Accuracy | ±5 mbar |
| Gas Inlets | 2 Independently Controlled (Air & Optional Process Gas), Tubing Material: 1.4571 (ASTM 316Ti) |
| Safety Systems | Dual Pt100 Class A Sensors per Shelf (4-wire), MLOP Multi-Level Overheat Protection, Mechanical Temperature Limiter (TB), Microprocessor-Based Thermal Monitoring with ASF (Automatic Setpoint Linking), Audible/Visual Alarms, Door-Interlocked Rapid Venting, Leak Rate ≤ 0.01 bar/h, Final Vacuum ≤ 0.01 mbar |
| Programming | 40 Programmable Temperature–Vacuum Profiles, Each with Up to 99 Segments |
| Compliance | Designed and tested per DIN 12880, EN 61000-6-3, EN 61000-6-4, IEC 61010-1, and compatible with GLP/GMP documentation requirements including audit-trail-capable operation when used with MEMControl software |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | WNB10 |
| Instrument Type | Water Bath Circulator |
| Circulation | Internal Recirculation |
| Temperature Control | Heating-Only |
| Bath Volume | 10 L |
| Temperature Range | 10–95 °C (with dedicated boiling mode at 100 °C) |
| Temperature Stability | ±0.1 °C (typical, under standard lab conditions) |
| Temperature Resolution | 0.1 °C |
| Time Setting Range | B-type controller: 1 min – 99 h 59 min |
| E-type controller | 1 min – 999 h |
| Overtemperature Protection | Dual (B-type) or Triple (E-type), including electronic and mechanical safety cutoffs |
| Construction | AISI 304 stainless steel bath and housing |
| Compliance | CE-marked, tested to IEC 61010-1 for laboratory equipment safety |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | WNB14 |
| Instrument Type | Water/Oil Bath Circulator |
| Circulation | Internal Recirculation |
| Temperature Control | Heating-Only |
| Bath Volume | 14 L |
| Temperature Range | 10 °C to 95 °C (min. setpoint ≥5 °C above ambient) |
| Boiling Mode | 100 °C |
| Temperature Stability | ±0.1 °C (typical, at 37 °C, no load) |
| Temperature Resolution | 0.1 °C |
| Timer Range | B-type: 1 min–99 h 59 min |
| E-type | 1 min–999 h |
| Timer Accuracy | ±1 min |
| Overtemperature Protection | Triple-stage (E-type) / Dual-stage (B-type) |
| Construction | Stainless Steel AISI 304 Bath & Housing |
| Certifications | CE, EN 61000-6-3, EN 61000-6-2, IEC 61010-1 |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | WNB22 |
| Instrument Type | Circulating Water Bath |
| Internal Volume | 22 L |
| Temperature Range | 10 °C to 95 °C (with optional boiling mode at 100 °C) |
| Temperature Stability | ±0.1 °C (typical, at 37 °C, load-free) |
| Temperature Resolution & Setpoint Accuracy | 0.1 °C |
| Control System | PID with self-diagnostic function |
| Sensor | Dual 4-wire Pt100 (E-type), single 4-wire Pt100 (B-type) |
| Overtemperature Protection | Triple-stage (E-type) / Dual-stage (B-type) |
| Timer Range | B-type: 1 min – 99 h 59 min |
| E-type | 1 min – 999 h |
| Power Rating | 2000 W |
| Construction | Stainless steel inner bath and outer housing (AISI 304) |
| Certifications | CE, tested to IEC 61010-1 for laboratory safety |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | WNB29 |
| Instrument Type | Immersion Circulating Water Bath |
| Circulation | Internal Recirculation |
| Temperature Control | Heating-Only |
| Bath Volume | 29 L |
| Temperature Range | 10 °C to 95 °C (min. setpoint ≥5 °C above ambient) |
| Boiling Mode | 100 °C |
| Temperature Stability | ±0.1 °C (typical, at 37 °C, load-free) |
| Temperature Resolution & Setpoint Accuracy | 0.1 °C |
| Timer Range | B-type: 1 min – 99 h 59 min |
| E-type | 1 min – 999 h |
| Overtemperature Protection | Triple-stage (E-type) / Dual-stage (B-type) |
| Construction | AISI 304 Stainless Steel Inner Bath & Housing |
| Certifications | CE, EN 61010-1, IEC 61000-6-3 |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | WNB45 |
| Instrument Type | Immersion Circulating Water Bath |
| Circulation | Internal Recirculation |
| Temperature Control | Heating-Only |
| Bath Volume | 45 L |
| Temperature Range | 10 °C to 95 °C (min. setpoint ≥5 °C above ambient) |
| Boil Mode | 100 °C |
| Temperature Stability | ±0.1 °C (typical at 37 °C, load-dependent) |
| Temperature Resolution & Setpoint Accuracy | 0.1 °C |
| Timer Range | B-Type: 1 min – 99 h 59 min |
| E-Type | 1 min – 999 h |
| Overtemperature Protection | Triple-stage (E-Type) / Dual-stage (B-Type) |
| Construction | Stainless Steel 1.4301 (AISI 304) Inner Bath & Outer Casing |
| Certifications | CE, EN 61000-6-3, EN 61000-6-2, IEC 61010-1 |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | WNB7 |
| Temperature Range | 10–95 °C (with dedicated boiling mode at 100 °C) |
| Display & Setpoint Resolution | 0.1 °C |
| Heating Power | 1200 W |
| Bath Capacity | 7 L |
| Internal Dimensions (L×W×H) | 240 × 210 × 140 mm |
| External Dimensions (with flat lid) | 468 × 356 × 238 mm |
| External Dimensions (with gabled lid) | 468 × 356 × 337 mm |
| Construction | Stainless steel inner bath and outer housing |
| Safety Certifications | CE-compliant, tested to EN 61010-1 and EN 61326-1 |
| Overtemperature Protection | Dual (B-type) or Triple (E-type) independent safety circuits |
| Timer Range | B-type: 1 min – 99 h 59 min |
| E-type | 1 min – 999 h |
| Temperature Sensor | Four-wire Pt100 (1 sensor standard on B-type |
| Optional Accessories | Flat/gabled lids, orbital shaker module, conical flask holders (100–500 mL), tube racks (14.5–32 mm diameter), liquid-level controller, adjustable-height stands |
| Brand | Memmert (Germany) |
|---|---|
| Origin | Germany |
| Model | WTB |
| Construction | 304 Stainless Steel Interior |
| Control Interface | Capacitive Touchscreen with CustomView™ Personalization |
| Temperature Calibration | Dual-Point Adjustable Calibration |
| Standard Accessories | Stainless Steel Lid with Ventilation Peak |
| Optional Modules | Benchtop Platform, Tube Racks, Horizontal Shaking Module |
| Drainage | Rapid Full-Volume Drain Valve |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InMotion KF |
| Sample Capacity | 6–26 positions (interchangeable turntables) |
| Max. Continuous Samples | 120 |
| Temperature Control | Programmable heating profile (scan & linear ramp) |
| Automation | Fully automated drift–blank–sample sequence |
| Compliance | Designed for integration with METTLER TOLEDO Karl Fischer titrators (e.g., V30S, G20, etc.) and compliant with ISO 8533, ASTM E203, USP <921>, and GLP/GMP data integrity requirements |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | PYRO SA |
| Instrument Type | Crucible Furnace |
| Max Temperature | 1200 °C |
| Temperature Control | PID-based dual-stage thermocouple system with DKD-traceable calibration |
| Max Power | 1200 W |
| Time to Max Temperature | ≤20 min |
| Heating Elements | Resistance wire, SiC rods, MoSi₂ rods |
| Internal Chamber Dimensions | 480 mm (W) × 550 mm (D) × 560 mm (H) |
| Acid Management System | Quartz-lined chamber, quartz condenser, PTFE/PFA acid traps, NaOH neutralization stage, corrosion-resistant PTFE vacuum pump (20 mbar, 40 L/min) |
| Airflow Design | Perforated honeycomb alumina ceramic wall for continuous oxidative airflow over crucibles |
| Brand | MITR |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Plastic Floating Rack |
| Price Range | USD 0.15–7.50 |
| Brand | MKN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | KDM-A (Quadruple) |
| Pricing | Available Upon Request |
| Power Supply | 220 V, 50 Hz |
| Temperature Range | Ambient to 300 °C |
| Control Accuracy | ±1 °C |
| Vessel Capacity Options | 250 mL × 4 |
| Heating Power | 200 W × 4 |
| Display | LED Digital |
| Insulation Material | High-Efficiency Thermal Insulation Matrix |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | DGT2006(B), DGT202(B), DGT302(B) |
| External Dimensions (D×W×H) | 107×130×128 cm / 144×207×190 cm / 148×211×194 cm |
| Chamber Dimensions (D×W×H) | 80×80×100 cm / 110×150×160 cm |
| Chamber Volume | 640 L / 2640 L |
| Temperature Range | Ambient +20 °C to 200 °C |
| Temperature Uniformity | ±2.5% of setpoint |
| Temperature Fluctuation | ±0.5 °C |
| Heating Power | 5.5 kW / 17.5 kW |
| Construction | Stainless Steel Interior (B-series), Epoxy-Coated Mild Steel Exterior |
| Control System | PID Digital Temperature Controller with LED Display |
| Air Circulation | Forced Convection via Rear-Mounted Horizontal Fan |
| Safety Features | Independent Over-Temperature Cut-Off, Short-Circuit Protection, Pressure-Relief Safety Door |
| Compliance | JB/T 5520–1991 “Technical Specifications for Drying Ovens” |