Coordinate Measuring Machine
Filter
Showing 1–30 of 34 results
| Brand | Aberlink |
|---|---|
| Origin | United Kingdom |
| Configuration | Bridge-Type |
| Operation Mode | Fully Automated |
| Instrument Orientation | Vertical |
| Measurement Principle | Contact-Based Tactile Probing |
| Structural Base | Granite Table with Honeycomb Aluminum Core |
| Bearing System | Self-Cleaning Preloaded Air Bearings on All Three Axes |
| Drive Mechanism | Zero-Backlash Frictionless Transmission |
| Control Architecture | Integrated Industrial PC and Motion Controller |
| Mounting Interface | Standard M6 Threaded Grid Across Table Surface |
| Compliance | Designed for ISO 10360-2 (CMM Performance Verification) and ISO 14253-1 (Geometrical Product Specifications) |
| Brand | Aberlink |
|---|---|
| Origin | United Kingdom |
| CMM Type | Bridge Configuration |
| Orientation | Vertical |
| Operation Mode | Fully Automatic |
| Measurement Principle | Contact-Based Tactile Probing |
| Structural Frame Material | Aerospace-Grade Aluminum Alloy |
| Load-Bearing Platform Capacity | Up to 6,000 kg |
| Base Interface | Direct-Foot Ground Coupling |
| Compliance | Designed for ISO 10360 and VDI/VDE 2617 Part 2 conformance |
| Brand | Aberlink |
|---|---|
| Origin | United Kingdom |
| Model | Fulcrum |
| Configuration | Cantilever-type |
| Operation Mode | Manual |
| Portability | Portable |
| Measurement Method | Contact-based (tactile probing) |
| Measurement Volume | 280 × 280 × 150 mm |
| Accuracy | (5.0 µm + L/1000 mm) |
| Standard Operating Temperature Range | 5 – 45 °C |
| Power Supply | Single-phase AC, no compressed air required |
| Primary Application | In-process rough inspection near machine tools |
| Brand | Aberlink |
|---|---|
| Origin | United Kingdom |
| CMM Type | Bridge Configuration |
| Operation Mode | Fully Automatic |
| Instrument Orientation | Vertical |
| Measurement Principle | Contact-Based Tactile Probing |
| Drive System | Frictionless Linear Motor Drive |
| Structural Design | Decoupled Motor Architecture (Motors Isolated from Granite Base) |
| Worktable | M6 Threaded Grid Mounting Surface |
| Integrated Control | Embedded Industrial PC and Motion Controller |
| Base Construction | Vibration-Damped Granite Base |
| Compliance Context | Designed for ISO 10360-compliant dimensional verification in production and QA environments |
| Brand | Aberlink |
|---|---|
| Origin | United Kingdom |
| Structure Type | Bridge |
| Operation Mode | Manual |
| Instrument Orientation | Vertical |
| Measurement Principle | Contact-Based Tactile Probing |
| Bearing System | Preloaded Self-Regulating Air Bearings |
| Drive System | Closed-Loop Servo Motor |
| Frame Material | High-Grade Aerospace Aluminium Alloy |
| Worktable Surface | Granite (Load Capacity: 1500 kg) |
| Probe Compatibility | Renishaw Multi-Series Touch Probes |
| Optional Software Module | CAD-Based Best-Fit Alignment & Deviation Analysis |
| [Brand | ACCRETECH (Tokyo Seimitsu) |
|---|---|
| Origin | Japan |
| Model | ROUNDCOM Series |
| Type | CNC-Driven, Shop-Floor Hardened Coordinate Metrology System |
| Bearing Technology | Air-Bearing Spindle (Z & R Axes) |
| Rotation Accuracy | ≤0.01 µm (ROUNDCOM 65B), ≤0.02 µm (ROUNDCOM 60A/45A) |
| Max. Workpiece Load | 250 kg |
| Max. Measurable Diameter | Φ580 mm |
| Max. Measurable Height | 900 mm (Std.) |
| Control Mode | Fully Automatic CNC |
| Compliance | CE Marked |
| Standard Vibration Isolation | Integrated Air-Damped Granite Base |
| Sensor Mounting | Patented Dual-Axis Auto-Positioning Bracket (XY + YZ Rotational Degrees of Freedom) |
| Software Platform | TIMS — Total Integrated Measurement Suite] |
| Brand | Accretech |
|---|---|
| Origin | Japan |
| Model | XYZAX AXCEL |
| Configuration | Bridge-type (Vertical CMM) |
| Operation Mode | Fully Automatic |
| Measurement Principle | Contact-based tactile probing |
| Standard Air Suspension | Included for Z800+ models |
| Optional Features | Auto Probe Changer, PH10T Motorized Indexing Head with TP200 Sensor (±180° horizontal, 0–105° vertical, 7.5° minimum indexing step, supports up to 300 mm extension probes) |
| Drive System | Newly developed high-acceleration linear drive (64% faster velocity, 35% higher acceleration vs. prior generation) |
| Structural Design | Reinforced rigid bridge architecture with optimized Y-axis torsional stiffness |
| Energy Efficiency | Intelligent air supply cutoff during standby mode |
| Compliance | Designed to meet ISO 10360-2 (CMM performance verification) and VDI/VDE 2617 standards |
| Brand | Accretech (Tokyo Seimitsu) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XYZAX Series |
| Operation Mode | Fully Automatic |
| Instrument Type | Shop-Floor CMM |
| Measurement Technology | High-Accuracy Cartesian Metrology with Dynamic Scanning & Real-Time Probe Compensation |
| Standard Software | CALYPSO v7.x (ZEISS) |
| Compliance | JIS B 7440-2:2003, ISO 10360-2, ISO 15530-3, ASTM E1378, GLP/GMP-ready audit trail support |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC003-Daisy564 |
| Pricing | Available Upon Request |
| Measuring Volume (mm) | 500 × 600 × 400 |
| Maximum Permissible Error (MPE) E0,MPE (� | m): 2.2 + L/300 |
| Probe Form Error (PFE) (� | m): 2.2 |
| Maximum Workpiece Load (kg) | 500 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | API ARM |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Configuration | Articulated Arm CMM |
| Operation Mode | Manual |
| Form Factor | Portable |
| Measurement Volume | 2.0 m – 4.5 m (configurable arm length) |
| Volumetric Accuracy | ±0.032 mm |
| Operating Temperature Range | 10 °C – 45 °C |
| Brand | API |
|---|---|
| Origin | USA |
| Model | Axxis |
| Probe Weight | < 400 g |
| Sampling Rate | Up to 26,000 points/sec |
| Depth of Field | 100–200 mm |
| Measurement Accuracy | ±0.05 mm (2σ) |
| Repeatability | ±0.02 mm (3σ) |
| Operating Temperature | 0–45 °C |
| Relative Humidity | < 70 % RH |
| Compliance | ISO 10360-8 (for articulated arm-based laser scanning systems), ASTM E2924-22 (Standard Guide for 3D Scanning Systems in Industrial Metrology) |
| Brand | API |
|---|---|
| Origin | USA |
| Model | Axxis |
| Series Options | Series 100 (High-Accuracy), Series 200 (Standard-Accuracy) |
| Measurement Diameter | 2600 mm / 3200 mm / 4200 mm |
| Volumetric Accuracy | 0.060 mm to 0.350 mm (depending on model and configuration) |
| Arm Weight | ~4 kg |
| Degrees of Freedom | 6-axis articulating arm |
| Interface | USB 2.0 (hot-pluggable) |
| Environmental Compensation | Integrated temperature & humidity sensors with real-time thermal drift correction |
| Compatible Probe Types | Renishaw-triggered tactile probes, broadband laser line scanners, dedicated non-contact tube measurement probes |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CoreGAGE |
| Configuration | Articulated Arm CMM |
| Operation Mode | Manual |
| Form Factor | Portable |
| Measurement Method | Hybrid Contact & Non-Contact (Tactile Probe + Laser Line Scanner) |
| Measurement Volume Range | 2.0 m to 5.5 m (configurable by arm length) |
| Volumetric Accuracy | ±0.027 mm (ISO 10360-2 compliant) |
| Maximum Data Acquisition Rate | 1,200,000 points/sec |
| Standard Operating Temperature | 5 °C to 45 °C |
| Laser Line Probe (HDSD) | Accuracy ±15 µm (2σ, near-field), ±28 µm (2σ, far-field) |
| Laser Line Probe Baseline Distance | 115 mm |
| Effective Scan Width | 80 mm (near-field) / 150 mm (far-field) |
| Points per Scan Line | Up to 4,000 |
| Laser Class | Class 2 |
| HDSD Probe Weight | 536 g |
| Arm Material | Aerospace-Grade Carbon Fiber |
| Integrated Balancing System | Yes |
| Battery Life | >10 hours (dual high-capacity Li-ion) |
| Wireless Data Transmission | IEEE 802.11ac Wi-Fi |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IP-360 Wireless |
| Price Range | USD 70,000–100,000 (FOB) |
| Configuration Type | Hybrid CMM Probe |
| Operation Mode | Manual Handheld |
| Instrument Form Factor | Portable |
| Measurement Range | Not Applicable (Probe-Specific, Requires Host CMM) |
| Measurement Uncertainty | Compliant with ISO 10360-2 & ASME B89.4.10 |
| Standard Ambient Temperature | 20 °C ± 1 °C |
| Brand | API |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Nebula |
| Configuration | Horizontal Arm CMM |
| Operation Mode | Motorized Automatic |
| Application Class | Shop-Floor CMM |
| Measurement Range (X×Y×Z) | 0–10,000 mm |
| Volumetric Accuracy | ±(0.02 + 0.02L) mm, where L is measured length in meters |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PlusGAGE |
| Configuration | Articulated Arm CMM |
| Operation Mode | Manual |
| Form Factor | Portable |
| Measurement Method | Hybrid Contact & Non-Contact (Laser Line Probe Compatible) |
| Measurement Volume | 2 m to 5.5 m (configurable) |
| Volumetric Accuracy | ±0.009 mm |
| Maximum Data Acquisition Rate | 1,200,000 points/sec |
| Operating Temperature Range | 5 °C to 45 °C |
| Laser Line Probe (HDSD) | Accuracy ±15 µm (2σ), ±28 µm (2σ) |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ProGAGE |
| Configuration | Articulated Arm CMM |
| Operation Mode | Manual |
| Form Factor | Portable |
| Measurement Method | Hybrid Contact & Non-Contact (Laser Line Probe Compatible) |
| Measurement Volume | 2.0 m to 5.5 m (configurable) |
| Volumetric Accuracy | ±0.007 mm (ISO 10360-2 compliant) |
| Maximum Data Capture Rate | 1,200,000 points/sec |
| Operating Temperature Range | 5 °C to 45 °C |
| Laser Line Probe (HDSD) | Accuracy ±15 µm (2σ, near-field), ±28 µm (2σ, far-field) |
| Laser Line Probe Working Distance | 115 mm (nominal) |
| Laser Line Probe Scan Width | 80 mm (near-field) to 150 mm (far-field) |
| Laser Line Probe Points per Line | Up to 4,000 |
| Laser Class | Class 2 |
| Laser Probe Weight | 536 g |
| Arm Material | Aerospace-Grade Carbon Fiber |
| Wireless Data Transmission | IEEE 802.11ac Wi-Fi |
| Key | Brand: API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Upon Request |
| Resolution | 0.25 µm |
| Accuracy | 0.5 µm |
| Max Measuring Radius | 1500 mm |
| Sensor Type | High-Precision Inductive Transducer |
| Calibration | NIST-Traceable Laser Interferometer Calibration |
| Brand | API |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Saturn |
| Operation Mode | Manual |
| Instrument Type | Horizontal Configuration |
| Measurement Range | Custom-Engineered per On-Site Installation Requirements |
| Measurement Accuracy | Available upon Technical Consultation |
| Structural Frame | High-Strength Anodized Aluminum Alloy (Natural & Artificial Aging) |
| X-Axis Guidance | Low-Friction Precision Linear Bearing System with 90° Directional Flexibility |
| Y-Axis Support | Central Steel Reinforcement with Micrometer-Level Fine Adjustment |
| Sensor System | IP65-Rated Absolute Position Encoders Compatible with Magnetic Scale Technology |
| Display | Real-Time XYZ Coordinate Readout (Metric Units) |
| Standard Tooling | Interchangeable Scribing Probe Assembly for Marking and Contact Metrology |
| Brand | Chotest |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Domestic OEM |
| Model | 464 |
| Configuration | Bridge-Type |
| Operation Mode | Fully Automatic |
| Orientation | Vertical |
| Measurement Principle | Contact & Non-Contact Hybrid Metrology |
| Measurement Volume | 500 × 700 × 500 mm |
| Standard Temperature | 20 ± 2 °C |
| Minimum Air Supply Pressure | 6 bar |
| Primary Application Domains | Mechanical Manufacturing, Automotive Industry, Electronics, Aerospace, and Metrology Laboratories |
| Brand | Dantsin |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Scopecheck MB |
| Pricing | Upon Request |
| Configuration | Hybrid (Optical + Contact Probing Capable) |
| Operation Mode | Fully Automatic |
| CMM Class | Shop-Floor Hardened |
| Measurement Principle | Non-Contact Optical Imaging (Telecentric & Parallel Illumination) + Optional Tactile Probing |
| Measuring Volume Range | 500–2000 mm (X) × 600–3000 mm (Y) × 450–1500 mm (Z) |
| Volumetric Accuracy | ≤ 0.1 µm (at 20 ± 1 °C, thermal drift ≤ 0.5 K/h) |
| Maximum Scanning Speed | 250 mm/s |
| Base Material | Precision-Graded Granite |
| Guidance System | Air-bearing Linear Rails |
| Illumination System | Patented Parallel-Beam Telecentric Lighting with Removable Bottom Light Module |
| Environmental Compliance | ISO 10360-2, ISO 15530-3, VDI/VDE 2617 Part 9 |
| Brand | Dukin |
|---|---|
| Origin | South Korea |
| Model | GIANT |
| Structure | Cantilever (Horizontal Arm) |
| Base Material | Granite |
| Bearing Type | Air-bearing (High-Rigidity) |
| Thermal Compensation | Integrated Real-Time Temperature Compensation System |
| Compliance | Designed for ISO 10360-2 & ASME B89.4.1-2019 geometric accuracy verification |
| Brand | Dukin |
|---|---|
| Origin | South Korea |
| Model | SIGMA 564 |
| Structure | Dual-Column Bridge |
| Base Material | Granite |
| Bearing Type | Air-bearing |
| Application Scope | Small-to-Medium-Sized Precision Components |
| Compliance Context | ISO 10360, VDI/VDE 2617, ASME B89.4.10 |
| Brand | API |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Galaxy V |
| Operation Mode | Fully Automatic |
| Measurement Range | X: 1000–20000 mm, Y: 800–1600 mm, Z: 800–3100 mm |
| Linear Positioning Accuracy | ≤0.1 mm (full travel) |
| Repeatability | ≤0.03 mm |
| Maximum Traverse Speed | 12,000 mm/min |
| Brand | PMT |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GAMMA 6-Axis |
| Configuration | Articulated Arm CMM |
| Operation Mode | Manual |
| Portability | Portable |
| Measurement Principle | Contact-Based Tactile Metrology |
| Measurement Volume | 1.5–4.5 m (customizable) |
| Accuracy | ±0.012 mm (ISO 10360-2 compliant at 20 °C) |
| Standard Operating Temperature | 5–45 °C |
| Relative Humidity | 0–95 % RH (non-condensing) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Battery Life | ≥16 h (single battery, tactile probing), ≥32 h (dual battery) |
| Weight | 8.8–10.6 kg |
| Material | Aerospace-Grade Carbon Fiber Structural Members |
| Balance System | Patented External Decoupling Internal Counterbalance Mechanism |
| Environmental Compensation | Real-time thermal drift compensation (±3 °C / 5 min) |
| Connectivity | Dual-mode — USB 3.2 Gen 1 (high-reliability wired data transfer) and Custom 5 GHz Wi-Fi Module (low-latency wireless telemetry) |
| Software Interface | Standardized SDK & API for third-party metrology software integration (e.g., PolyWorks, Geomagic Control, PC-DMIS) |
| Compliance | Designed to support ISO 9001, AS9100, and GLP/GMP-aligned audit trails when paired with validated software environments |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | PH10 |
| Interface Compatibility | AutoJoint (PH10M/MQ) or M8 threaded (PH10T) |
| Maximum Probe Extension | 300 mm |
| Compatible with | ACR3 automatic probe changer, SP25M 3-axis scanning probe (2000 points/sec, 100 mm/s scan speed), TP20/TP200 touch-trigger probes |
| Regulatory Compliance | Designed for integration into ISO/IEC 17025-accredited CMM environments |
| Software Integration | Native support for PC-DMIS, QUINDOS, and MODUS metrology software suites |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | PH20 |
| Type | Motorized 5-Axis Touch-Trigger Probe Head |
| Power Requirement | None (Passive, No Air Supply Required) |
| Compatibility | Retrofitable to Existing CMMs with TP20-style Interface |
| Calibration Method | Inferred Calibration (Single-Point Vector Determination) |
| Mounting Options | Direct Spindle Mount or Via Adaptor Kits (e.g., ISO 40/50, HSK, CAT) |
| Software Integration | Native Support in MODUS, PC-DMIS, QUINDOS, and OpenDMIS |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PH20 |
| Pricing | Available Upon Request |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | REVO™ |
| Pricing | Upon Request |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RTP20 |
| Probe Type | Integrated TP20 Touch Trigger Probe |
| Indexing Increment | 15° |
| Compatibility | Fully Supported by Standard CMM Controllers (e.g., Renishaw UCC Series) |
| Module Exchange | Compatible with MCR20 Automatic Module Changer Rack |
| Actuation Method | CMM-Motion-Driven Mechanical Engagement (No Internal Motor or Encoder) |
| Classification | Precision Geometric Measurement Instrument — Coordinate Measuring Machine (CMM) Peripheral |