Densitometer
Filter
Showing 1–30 of 45 results
| Brand | A.Krüss / A.Krüss Optronic |
|---|---|
| Origin | Germany |
| Model | DS7800 |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0.0000–1.9999 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Control Range | 10–40 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052-18, ASTM D5002, ISO 12185:1996, ISO 2811-3:2011, SH/T 0604-2000, GB/T 21862.3-2008 |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EJ-120D |
| Weighing Capacity | 120 g |
| Readability | 0.01 g |
| Density Resolution | 0.01 g/cm³ |
| Repeatability | 0.01 g |
| Pan Size | 110 mm |
| Display | Backlit LCD, 16 mm digit height |
| Interface Options | RS-232 or driver-free USB |
| Power Supply | AC adapter and rechargeable battery dual mode |
| Compliance | GLP/GMP/GCP and ISO-compliant calibration reporting |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-300iD / EK-3000iD |
| Instrument Type | Benchtop Solid Density Analyzer |
| Measurement Principle | Archimedean Buoyancy Method (Air Weight / (Air Weight − Immersed Weight) × Reference Liquid Density) |
| Density Range | 0–2.000 g/cm³ |
| Density Resolution | 0.001 g/cm³ (EK-300iD) / 0.01 g/cm³ (EK-3000iD) |
| Temperature Range | 0–100 °C |
| Minimum Sample Mass | 0.001 g |
| Reference Liquids | Water, Kerosene, or User-Defined Liquids (Density Input Range: 0.000–2.000 g/cm³) |
| Temperature Compensation | Automatic |
| Data Storage | 200 Records |
| Interface | RS-232 |
| Compliance | GLP/GMP/GCP Audit Trail Ready, ISO/IEC 17025 Support Enabled |
| Software | WinCT Data Acquisition Suite (Windows-compatible, Excel export, statistical analysis, graphing) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-300iD / GF-300D |
| Instrument Type | Buoyancy-Based Density Balance |
| Measurement Principle | Archimedes’ Principle |
| Weighing Capacity | 300 g (EK-300iD), 310 g (GF-300D) |
| Weighing Readability | 0.01 g (EK-300iD), 0.001 g (GF-300D) |
| Density Resolution | 0.001 g/cm³ |
| Display | Backlit LCD (16 mm character height, EK-iD series) |
| Stabilization Time | ≤1 s (GF-D series) |
| Internal Resolution | 1/10,000,000 |
| Environmental Response Modes | FAST / MID / SLOW |
| Calibration | Full-digital span calibration with user-adjustable reference weight input |
| Temperature Compensation | Direct water temperature or reference liquid density entry |
| Density Comparison Mode | Hi / OK / Lo alarm output (optional external relay module) |
| Auto Power-Off | Configurable after ≥10 min inactivity |
| Interface | RS-232C standard port |
| Software | WinCT v3.x (Windows-compatible, supports Excel/Office data export, statistical analysis, time-series logging, and chart-based visualization) |
| Compliance | Built-in GLP/GMP/ISO audit trail functions (date/time stamping, instrument ID, calibration history, operator ID, measurement statistics) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | ElaTest |
| Density Measurement Range | 0.8–2.6 g/cm³ |
| Temperature Range | 0–40.0 °C |
| Repeatability | ±0.00001 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 40–120 cm³ |
| Application | Density of uncured rubber and rubber compounds |
| Instrument Type | Benchtop Laboratory Densitometer |
| Detection Principle | Pneumatic (gas displacement) density measurement |
| Compliance | Designed for GLP/GMP environments with audit-ready data handling |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DMA 1002 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ±0.00005 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Temperature Range | 15–60 °C |
| Temperature Stability | ±0.02 °C |
| Minimum Sample Volume | 1 mL |
| Display | 7″ TFT WVGA Touchscreen (800 × 480 px, PCAP) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DMA 1002/1102 Petro |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Category | Portable |
| Sample Type | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Range | 15 °C to 100 °C (59 °F to 212 °F) |
| Temperature Accuracy | ±0.03 °C (from +15 °C to +100 °C) |
| Density Resolution | 5 significant digits |
| Viscosity Range (DMA 1102 only) | –0.3 mm²/s to 1000 mm²/s |
| Viscosity Repeatability | ±0.2% |
| Minimum Sample Volume | 3.5 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP touch screen |
| Dimensions (L×W×H) | 365 mm × 265 mm × 180 mm |
| Weight | 6.6 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 1102 Petro |
| Instrument Type | Oscillating U-tube Densimeter |
| Application | Petroleum Products Density & Kinematic Viscosity Measurement |
| Detection Medium | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Resolution | 5 significant digits |
| Temperature Range | 15 °C to 100 °C (59 °F to 212 °F) |
| Temperature Stability | ±0.03 °C over full range |
| Viscosity Range | −0.3 mm²/s to 1000 mm²/s |
| Viscosity Repeatability | ±0.2% |
| Minimum Sample Volume | 3.5 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Dimensions (L×W×H) | 365 × 265 × 180 mm |
| Weight | 6.6 kg |
| Power Supply | DC 24 V / 3 A |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 4002 / DMA 5002 / DMA 6002 |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Class | Benchtop Laboratory Densimeter |
| Sample Type | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.00005 g/cm³ (DMA 4002), ±0.00001 g/cm³ (DMA 5002, 0–1.05 g/cm³ at 15–20 °C), ±0.000005 g/cm³ (DMA 6002, full range) |
| Temperature Range | 0 °C to 100 °C |
| Temperature Accuracy | ±0.02 °C (DMA 4002), ±0.01 °C (DMA 5002 & DMA 6002, 15–20 °C) |
| Density Repeatability (Std. Dev.) | 0.00001 g/cm³ (DMA 4002), 0.000003 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002) |
| Density Resolution | 0.00001 g/cm³ (DMA 4002), 0.000005 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002) |
| Minimum Sample Volume | 1 mL |
| Display | 10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen |
| Compliance | ASTM D4052, D5002, D1250 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | 0.0001 g/cm³ (DMA 4100M) / 0.00005 g/cm³ (DMA 4500M) / 0.000005 g/cm³ (DMA 5000M) |
| Temperature Range | 0 °C to 95 °C |
| Temperature Accuracy | ±0.05 °C (4100M) / ±0.03 °C (4500M) / ±0.01 °C (5000M) |
| Minimum Sample Volume | 1 mL |
| Repeatability (Std. Dev.) | 0.00005 g/cm³ (4100M) / 0.00001 g/cm³ (4500M) / 0.000001 g/cm³ (5000M) |
| Display | 10.4" PCAP TFT Touchscreen (640 × 480 px) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP, ISO 12084, ASTM D4052, USP <841> |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA 4200 M |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densitometer |
| Sample Type | Liquid (including high-viscosity, solid-at-room-temperature, and pressurized samples) |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ≤0.00005 g/cm³ (standard deviation) |
| Temperature Range | −10 °C to +200 °C (14 °F to 392 °F) |
| Temperature Accuracy | ±0.03 °C |
| Pressure Range | 0–500 bar (0–7,250 psi) |
| Minimum Sample Volume | 2 mL |
| Measuring Cell Material | Hastelloy C-276 |
| Cell Volume | ~2 mL |
| Dimensions | 510 × 330 × 230 mm (20 × 13 × 8.7 in) |
| Weight | 27.1 kg (59.7 lb) |
| Power Supply | AC 100–240 V, 50–60 Hz, 250 VA |
| Interfaces | 4 × USB 2.0, 2 × S-Bus, 1 × Ethernet (100 Mbit), 1 × CAN Bus, 1 × RS-232, 1 × VGA |
| Brand | Anton Paar |
|---|---|
| Origin | Japan (manufactured in Austria) |
| Model | DMA 5001 |
| Instrument Type | Laboratory Benchtop Densitometer |
| Sample Type | Solid & Liquid Compatible |
| Measurement Principle | Oscillating U-tube (ASTM D4052, ISO 12185, USP <841>) |
| Density Range | 0 to 3 g/cm³ |
| Temperature Range | 0 °C to 100 °C |
| Accuracy (Density) | ±0.000005 g/cm³ |
| Repeatability (Density) | ±0.000001 g/cm³ |
| Minimum Sample Volume | ~1 mL |
| Display | 10.1″ TFT WXGA Touchscreen (1280 × 800 px) |
| Data Storage | >10,000 measurements with embedded camera images |
| Measurement Time | ≤40 s per sample |
| Operating System | Real-time embedded OS (8× faster than previous generation) |
| CPU | Dual-core processor (2× speed increase) |
| Compliant | FDA 21 CFR Part 11, GLP/GMP audit trail, ISO/IEC 17025 traceability support |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 502 |
| Instrument Type | Oscillating U-tube Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids and Low-Viscosity Suspensions |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0002 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | 15–40 °C |
| Temperature Stability | ±0.1 °C |
| Minimum Sample Volume | 1 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Environmental Compensation | Automatic pressure, altitude, and ambient humidity correction |
| Data Storage | 5000 measurements |
| Method Library | 400 pre-validated methods |
| Conversion Tables | 140 built-in (alcohol, sugar, acids, API gravity, etc.) |
| Compliance | ASTM D4052, ASTM D5002, USP <841>, EP/JP pharmacopoeial density requirements, FDA 21 CFR Part 11 (when used with AP Connect) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DMA 6002 Sound Velocity |
| Instrument Type | Oscillating U-tube Densimeter & Sound Velocity Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Sound Velocity Range | 1000 m/s to 2000 m/s |
| Temperature Range | 0 °C to 100 °C (32 °F to 212 °F) |
| Pressure Range | 0 bar to 8 bar (0 psi to 116 psi) |
| Density Accuracy | ±0.000005 g/cm³ |
| Density Repeatability (Std. Dev.) | ±0.000001 g/cm³ |
| Sound Velocity Repeatability (Std. Dev.) | ±0.1 m/s |
| Density Reproducibility (Std. Dev.) | ±0.000005 g/cm³ |
| Sound Velocity Reproducibility (Std. Dev.) | ±0.5 m/s |
| Density Resolution | 0.000001 g/cm³ |
| Sound Velocity Resolution | 0.01 m/s |
| Minimum Sample Volume | 3.5 mL |
| Measurement Throughput | Up to 30 samples/hour |
| Compliance | ISO 5725, ASTM D4052, ASTM D1250, ISO 12185, ISO 17025 (when operated with certified calibration standards) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA35 |
| Instrument Type | Portable Digital Density Meter |
| Measurement Principle | Oscillating U-tube (OUM) |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability (std. dev.) | ±0.0005 g/cm³ |
| Temperature Range (Sample) | 0–40 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Repeatability | ±0.1 °C |
| Sample Volume | 1–2 mL |
| Resolution | 0.0001 g/cm³ (density), 0.1 °C (temperature) |
| Environmental Operating Range | −10 to +50 °C (standard) |
| Protection Rating | IP54 |
| ATEX/IECEx Certification | II 2G Ex ib IIB T4 Gb (DMA35 Ex & DMA35 Ex Petrol) |
| Data Storage | 1024 measurements, 30 methods, 250 sample IDs |
| Interface | Bluetooth®, RFID, IrDA |
| Power Supply | 3 × AA alkaline batteries (LR06) |
| Weight | 660 g |
| Dimensions (L×W×H) | 245 × 103 × 126 mm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Perfume and Flavor Measurement System |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Display | 10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen |
| Temperature Control Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Integrated Parameters | Density, Refractive Index, Optical Rotation, Colorimetry, Turbidity |
| Automation | Fully Automated Sample Handling with Recovery (Xsample 5200/530), Integrated Cleaning & Drying |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Ultrapyc Series |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Solids (bulk & granular), Powders, Pastes, Slurries, Foams |
| Density Accuracy | ≤0.015% |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Temperature Range | 3–60 °C |
| Minimum Sample Volume | 0.1 cm³ |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 2/3 Column |
| Density Range | 0.8–3.3 g/cm³ (dependent on selected gradient liquid mixture and calibrated sinkers) |
| Accuracy | ±0.0001 g/cm³ at 23.0 ± 0.1 °C |
| Temperature Control | Digital, 5–50 °C ±0.1 °C |
| Bath Volume | ~45 L (transparent acrylic) |
| Cooling | External coil heat exchanger |
| Agitation | Integrated circulation pump |
| Sample Handling | Motorized lift system for sinkers and specimens |
| Gradient Column | Calibrated glass tube, 850 mm total length |
| Accessories | Precision column filling system, NIST-traceable calibrated sinkers |
| Brand | DahoMeter |
|---|---|
| Origin | Guangdong, China |
| Model | DA-300M109 |
| Instrument Type | Laboratory Benchtop Buoyancy-Based Density Meter |
| Sample Type | Solids (Rubber, Elastomers, Polymers, Composites, Ceramics, Metals, Powders) |
| Density Range | 0.001–99.999 g/cm³ |
| Density Resolution | 0.001 g/cm³ |
| Temperature Range | 0.0–100.0 °C |
| Minimum Sample Mass | 0.005 g |
| Maximum Capacity | 300 g |
| Measurement Medium | Water or User-Defined Liquid |
| Compliance | ASTM D297, GB/T 533, GB/T 9867, DIN 53516, ISO 4649, GB/T 1689, ISO 1817 |
| Data Output | RS-232C interface |
| Additional Functions | DIN Abrasion Volume, Akron Abrasion Loss, ARI Index, Volume Expansion Ratio, Foaming Ratio, Mass/Volume Change Rate, Binary Mixture Composition Estimation, Pass/Fail Auto-Judgment |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERADEN X |
| Instrument Type | Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00001 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Temperature Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052, ASTM D5002, ISO 12185, SH/T 0604 |
| Key Feature | Integrated Auto-Drying Pump, Built-in Ambient Pressure Sensor, FillingProof™ Bubble-Resistant Sampling Technology, Corrosion-Resistant Aluminum Housing, Vertical Oscillating X-U-Tube Design |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAdens X |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample State | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00001 g/cm³ |
| Density Repeatability | ±0.000005 g/cm³ |
| Resolution | 0.00001 g/cm³ |
| Temperature Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052, SH/T 0604 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERADENS XS |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample State | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00005 g/cm³ |
| Density Resolution | 0.00005 g/cm³ |
| Temperature Range | 10–60 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052, ASTM D5002, ASTM D5931, ISO 12185, SH/T 0604 |
| Brand | HUAXI INSTRUMENT |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | XD50 |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0003 g/cm³ |
| Repeatability | ±0.0002 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 1 mL |
| Temperature Control Range | 5–65 °C |
| Display | 7-inch Full-Color Touchscreen |
| Brand | ADVANTEC |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | T5 Plus |
| Instrument Type | Portable Densitometer |
| Measurement Mode | Transmission (Black-and-White) |
| Sample Type | Solid and Liquid (Transparent/Translucent) |
| Density Range | 0–2.000 g/cm³ |
| Resolution | 0.001 g/cm³ |
| Aperture Options | φ1 mm, φ2 mm, φ3 mm |
| Power Supply | AC Adapter (9 V DC, 500 mA) |
| Compliance | ISO 5-3, ISO 5-4, ASTM E308, JIS Z 8722 |
| Software Interface | RS-232C (cable sold separately) |
| Calibration Standards | NIST-traceable calibration film included |
| Operating Temperature | 15–35 °C |
| Relative Humidity | ≤80 % RH (non-condensing) |
| Brand | MAYZUM |
|---|---|
| Model | MAYA203DIV2L |
| Type | Benchtop Solid Density Analyzer for Hydrogen Quantification in Aluminum Melts |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | −30 °C to +60 °C |
| Display | Digital LCD |
| Origin | Guangdong, China |
| Manufacturer | MAYZUM (OEM/ODM Capable) |
| Compliance | GB/T 43139–2023, GB/T 5611–2017, ASTM E807 (adapted), ISO 11922 (principles) |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MAYB124G |
| Instrument Type | Laboratory Benchtop Buoyancy-Based Densimeter |
| Sample Type | Liquids Only |
| Density Range | 0.0001–3.0000 g/cm³ (equivalent to 0.1–100% concentration for common aqueous/organic solutions) |
| Maximum Sample Weight Capacity | 120 g |
| Density Resolution | 0.0001 g/cm³ |
| Display | Digital LCD |
| Compliance Standards | GB/T 13531, GB/T 5526, GB/T 5009, ASTM D1298, ASTM D4052, JIS K 0061, ISO 12185 |
| Measurement Principle | Archimedean buoyancy displacement method |
| Brand | Mayzum |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MZ-Y300 |
| Instrument Category | Laboratory Benchtop Buoyancy-Based Densimeter |
| Sample Type | Solid Porous Materials |
| Density Range | 0.01–99.999 g/cm³ |
| Maximum Capacity | 300 g |
| Density Resolution | 0.001 g/cm³ |
| Display | Digital LCD |
| Application Scope | Universal Density Testing for Open- and Closed-Cell Porous Polymers |
| Compliance Context | Designed to support ASTM D3574, ISO 845, ISO 1183-1, and GB/T 6343 test protocols |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito / Densito Pro |
| Density Measurement Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Range | 0–50.0 °C |
| Minimum Sample Volume | 2 mL |
| Instrument Type | Portable Digital Density Meter (Oscillating U-tube Principle) |
| Application Scope | Liquid Density Measurement for QC/QA in Lab, Field, and Production Environments |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable data management |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito |
| Instrument Type | Portable Digital Density Meter |
| Sample Type | Solids and Liquids |
| Density Range | 0.000–3.000 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0005 g/cm³ |
| Operating Temperature Range | −10 °C to +50 °C |
| Measurement Units | g/cm³, g/mL, kg/m³, °Brix, API, °Baumé, % ethanol (v/v), % H₂SO₄, US/UK Proof, Plato, specific gravity, user-defined concentration scales |
| Data Storage Capacity | 1100 measurements with sample ID, temperature correction factor, instrument ID, timestamp, and unit |
| Display | Full-color backlit LCD |
| Language Support | English, Chinese, German, Spanish, French, Italian, Portuguese, Indonesian, Korean, Polish, Russian, Thai, Turkish |
| Connectivity | USB, optional printer output, compatible with EasyDirect PC software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D4 / D5 / D6 |
| Instrument Type | Benchtop Laboratory Density Meter |
| Sample Type | Solid and Liquid |
| Temperature Range | 0–95 °C (32–203 °F) |
| Repeatability | ±0.00005 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Density Range | 0.000–3.000 g/cm³ |
| Accuracy | ±0.0001 / ±0.00005 / ±0.000005 g/cm³ (model-dependent) |
| Temperature Accuracy | ±0.03 / ±0.02 / ±0.01 °C (model-dependent) |