| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Snap 51 |
| Instrument Type | Portable Digital Density Meter |
| Measurement Principle | U-tube Oscillation |
| Sample Volume | 2 mL |
| Density Range (for Ethanol-Water Mixtures) | 0–100 % v/v |
| Temperature Range (Measurement) | 0 °C to 40 °C (32 °F to 104 °F) with Automatic Temperature Compensation |
| Accuracy | ±0.1 % v/v (alcohol), ±0.1 °C (temperature) |
| Repeatability (Std. Dev.) | ±0.05 % v/v (alcohol), ±0.05 °C (temperature) |
| Reproducibility (Std. Dev.) | ±0.07 % v/v |
| Operating Ambient Temperature | −10 °C to +50 °C (14 °F to 122 °F) |
| Display | Capacitive Touchscreen |
| Data Storage | 1024 Results, 250 Sample IDs, 30 User-Programmable Methods |
| Connectivity | Bluetooth® 4.2, RFID Reader |
| Protection Rating | IP54 |
| Power Supply | 3 × 1.5 V LR06 AA Alkaline Batteries |
| Dimensions | 468 mm × 108 mm × 119 mm (18.4 in × 4.3 in × 4.7 in) |
| Weight | 860 g (30.3 oz) |
| Compliance | ISO 5725 (accuracy validation), ISO 15212-1 (alcohol determination in beverages), ASTM D4052 (density of liquids by digital density meter) |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Ultratap 500 |
| Instrument Type | Bulk Density Tester |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Solid Powders & Granules |
| Density Accuracy | 0.001 g/cm³ |
| Repeatability | 0.0001 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 5 mL |
| Vibration Frequency Range | 50–350 taps/min |
| Tap Amplitude | 3 mm ± 0.2 mm or 14 mm ± 1 mm |
| Noise Level | 65 dB (58 dB with optional noise-reduction cabinet) |
| Touchscreen | 7-inch TFT WVGA (800 × 480 px), PCAP |
| User Management | Password-protected |
| Built-in Methods | 24 (ASTM, ISO, USP <616> Methods 1–3) |
| Data Storage | 1,000 reports / 100 custom methods |
| Dimensions (H×W×D) | 228.6 × 263.5 × 361 mm (9 × 10.4 × 14.2 in) |
| Weight | 14.5 kg (single station) / 17.6 kg (dual station) |
| Power Input | 24 V DC, 2.1 A (51 W) / 2.6 A (63 W) |
| Brand | Anton Paar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Xsample Series |
| Sample Type | Liquid |
| Minimum Sample Volume | 5 mL / 10 mL (when coupled with DMA instruments) |
| Viscosity Range | up to 1000 mPa·s |
| Instrument Class | Benchtop Laboratory |
| Application Scope | Universal Density Measurement |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–enabled software environments |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 2/3 Column |
| Density Range | 0.8–3.3 g/cm³ (dependent on selected gradient liquid mixture and calibrated sinkers) |
| Accuracy | ±0.0001 g/cm³ at 23.0 ± 0.1 °C |
| Temperature Control | Digital, 5–50 °C ±0.1 °C |
| Bath Volume | ~45 L (transparent acrylic) |
| Cooling | External coil heat exchanger |
| Agitation | Integrated circulation pump |
| Sample Handling | Motorized lift system for sinkers and specimens |
| Gradient Column | Calibrated glass tube, 850 mm total length |
| Accessories | Precision column filling system, NIST-traceable calibrated sinkers |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-TD |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Solid (powder, granule, bulk, foam, ceramic, metal, rock core), slurry, non-volatile liquid |
| Density Range | 0.01–2000 g/cm³ |
| Density Accuracy | ±0.03% |
| Repeatability | ±0.015% |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 0.01–2000 mL |
| Temperature Control Range | 0–40 °C |
| Temperature Stability | < ±0.1 °C |
| Analysis Stations | 1 or 2 |
| Measurement Principle | Gas Expansion Displacement (based on ideal gas law PV = nRT) using inert gas (He or N₂) |
| Compliant Standards | GB/T 40401-2021, GB/T 10799-2008, GB/T 5071-2013, ASTM D2856, ASTM D6226, MT/T 713-1997 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | BSD-TD-K |
| Price Range | USD 14,000 – 21,000 |
| Application Field | General-purpose density analysis |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Types | Powders, solid blocks, slurries, liquids |
| Density Measurement Range | 0.001–10 g/cm³ (typical for solids & liquids) |
| Density Accuracy | ±0.03% (relative to certified Al reference standard) |
| Temperature Control Range | −10 °C to +50 °C, stability ±0.1 °C |
| Repeatability | ±0.00001 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 3 mL |
| Maximum Sample Volume | 2000 mL |
| Test Cycle Time | 3–6 min (excluding thermal equilibration) |
| Pressure Mode | Positive-pressure gas expansion (He or N₂, optional vacuum pump for degassing) |
| Valve System | Pneumatically actuated valves (zero self-heating) |
| Calibration Standard | Certified aluminum reference cylinder (NIM-traceable) |
| Compliance | GB/T 23561.2–2009, GB/T 10799–2008 (Annex B), ISO 12154:2014 (gas pycnometry), ASTM D5550–22 (standard test method for true density of calcined petroleum coke) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | BSD-TDK |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Measurement Principle | Gas Displacement (Helium Pycnometry) |
| Density Range | 0.01–2000 g/mL |
| Density Accuracy | ±0.06% |
| Repeatability | ±0.04% |
| Resolution | 0.0001 g/mL |
| Temperature Control Range | 0–40 °C |
| Sample Volume Capacity | 0.01–500 mL |
| Analysis Time | 3–5 min per run (≤60 s for 10 mL cell) |
| Standard Sample Cells | 10 mL, 50 mL, 150 mL (custom larger cells available) |
| Reference Chamber | Dual internal reference volumes optimized per cell size |
| Pressure Range | 0–1 bar (user-adjustable) |
| Operating Gas | High-purity helium (≥99.999%), nitrogen optional |
| Gas Handling | Automated multi-cycle purge & leak-check sequence |
| Data Compliance | Supports audit-trail export, PDF report generation (single/batch), GLP/GMP-ready metadata logging |
| Hardware Interface | Embedded controller with graphical UI, voice-guided operation, remote Internet control capability |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | ZKMD-6609b |
| Instrument Type | Bulk Density Tester (for Powders) |
| Application | Bulk density measurement of free-flowing and cohesive particulate solids (e.g., carbon fiber powders, metal powders, pharmaceutical granules) |
| Construction | Stainless steel |
| Portability | Benchtop (non-portable, fixed-position design) |
| Compliance Basis | ASTM D1895–23, ISO 697–2022, USP <616>, GB/T 1479.1–2011 |
| Sample Form | Dry, free-flowing or slightly cohesive solid powders only |
| Liquid Measurement Capability | None |
| Density Range | 0.1–5.0 g/cm³ (typical for powder bulk density applications) |
| Repeatability | ±0.01 g/cm³ (under controlled environmental conditions per ISO 29553) |
| Brand | CDJX |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JZ-10C |
| Instrument Type | Tap Density Tester |
| Density Measurement Range | 0–10 g/cm³ |
| Measurement Accuracy | ±1% RSD (Repeatability) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Programmable Tap Count | 1–9999 |
| Sample Capacity | ≤500 g (per 250 mL cylinder) |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Software Output Formats | PDF, Word, Excel |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 <0993>, USP <616> |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DenDi |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Archimedean Buoyancy (Oscillating U-tube not used |
| Density Range | 0 to 3 g/cm³ (0 to 3000 kg/m³) |
| Accuracy | ±0.0005 g/cm³ (±0.5 kg/m³) |
| Repeatability | ±0.00025 g/cm³ (±0.25 kg/m³) |
| Resolution | 0.0001 g/cm³ (0.1 kg/m³) |
| Temperature Range | +15 °C to +30 °C |
| Temperature Accuracy | ±0.01 °C |
| Sample Volume | 100 mL |
| Power Supply | Rechargeable NiMH 9 V / 150 mAh battery (up to 12 h operation) |
| Dimensions (H × L × W) | 135 × 100 × 190 mm |
| Weight | 1.3 kg |
| Compliance | ASTM D1298, ASTM D4052 (for reference correlation), ISO 12185 (petroleum density), DIN 51757, EN ISO 279 |
| Data Storage | 998 timestamped measurements onboard |
| Interface | Infrared (IrDA) for PC and thermal printer connectivity |
| Display | Backlit LCD with multi-unit real-time readout |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-070 |
| Instrument Type | Density Gradient Tube System |
| Portability | Portable |
| Measurement Medium | Liquids |
| Temperature Range | +5–60 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Bath Volume | 25–31 L |
| Heating Power | 2–11 W |
| Circulation Pump Pressure | 0.23–0.45 bar |
| Interface | RS-232 |
| Compliance | ASTM D1505, ISO 1183-1, USP <841> |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-250.1N |
| Density Range | 0–3 g/cm³ (0–3000 kg/m³) |
| Temperature Range | −40 to +85 °C |
| Density Accuracy | ±0.0003 or ±0.0005 g/cm³ |
| Density Repeatability | ±0.00015 or ±0.00025 g/cm³ |
| Temperature Repeatability | ±0.1 °C |
| Measurement Depth | 6 m |
| Display | OLED with backlight |
| Data Storage | 3000 readings |
| Battery | NiMH 3.6 V, 2500 mAh (≈40 h operation) |
| Communication | Bluetooth & USB |
| Sensor Materials | SS 316L, NiSpan C, Hastelloy C-22 (optional) |
| Certified | ATEX, IECEx HazLoc |
| Units Supported | g/cm³, kg/m³, lb/gal, lb/ft³, API, SG, ASTM D1250, alcohol tables, relative density at 15 °C / 20 °C / 60 °F / API60 / SG60 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-250.2N |
| Density Range | 0–3 g/cm³ (0–3000 kg/m³) |
| Density Accuracy | ±0.0003 or ±0.0005 g/cm³ (±0.3 or ±0.5 kg/m³) |
| Temperature Range | −40 to +85 °C |
| Temperature Accuracy | ±0.1 or ±0.2 °C |
| Density Repeatability | ±0.00015 or ±0.00025 g/cm³ (±0.15 or ±0.25 kg/m³) |
| Temperature Repeatability | ±0.1 °C |
| Max. Immersion Depth | 30 m |
| Data Storage Capacity | 2000 measurements |
| Battery | NiMH 3.6 V, 1500 mAh |
| Operating Time (fully charged) | ~12 h |
| Display | OLED with backlight |
| Sensor Materials | SS 316L stainless steel, NiSpan C, or Hastelloy C-22 (optional) |
| Compliance | ATEX, IECEx, UL/CSA HazLoc |
| Units Supported | g/cm³, kg/m³, lb/gal, lb/ft³, API gravity, specific gravity (SG), ASTM D1250 petroleum tables, alcohol tables, temperature (°C/°F) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-250.3 |
| Instrument Type | Oscillating U-tube Densimeter |
| Portability | Portable |
| Sample State | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.0003 or ±0.0005 g/cm³ |
| Density Repeatability | ±0.00015 or ±0.00025 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | −40 °C to +85 °C |
| Temperature Accuracy | ±0.1 °C |
| Maximum Pressure Rating | 16 bar (1.6 MPa) |
| Sensor Material Options | SS 316L, NiSpan C, Hastelloy C-22 |
| Intrinsic Safety Certification | ATEX II (2G) EEx ib [ia] IIB T4 (controller), ATEX II 1G EEx ia IIB T4 (sensor) |
| Sample Volume | 250 mL |
| Power Supply | Rechargeable NiMH 3.6 V / 1500 mAh (up to 12 h operation) |
| Dimensions (Controller) | 245 × 225 × 120 mm |
| Dimensions (Sensor) | 180 × 85 × 40 mm |
| Weight | ~6 kg |
| Display | Backlit LCD |
| Data Storage | 1980 entries with timestamp |
| Connectivity | Bluetooth, USB, printer/PC interface |
| Software | Windows-based data acquisition and analysis software |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-250.5 |
| Instrument Type | Portable Buoyancy-Based Density Meter |
| Application | Liquid Density Measurement |
| Density Range | 0 to 3 g/cm³ (0 to 3000 kg/m³) |
| Density Accuracy | ±0.0003 g/cm³ (±0.3 kg/m³) |
| Repeatability | ±0.00015 g/cm³ (±0.15 kg/m³) |
| Resolution | 0.0001 g/cm³ (0.1 kg/m³) |
| Temperature Range (Measurement) | −30 °C to +50 °C |
| Temperature Accuracy | ±0.1 °C |
| Operating Ambient Temperature | −40 °C to +85 °C |
| Viscosity Compensation Limit | up to 2000 cP |
| Intrinsic Safety Certification | ATEX II (2G) EEx ib [ia] IIB T4 (Controller), ATEX II 1G EEx ia IIB T4 (Sensor) |
| Communication | Bluetooth v5.0, Internal Data Storage |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-300 |
| Density Measurement Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0002 g/cm³ |
| Temperature Range | 0–50 °C |
| Temperature Accuracy | ±0.1 °C |
| Probe Material | 316L Stainless Steel, Nickel-Based Alloy, Hastelloy C-22 |
| Dimensions | 140 × 100 × 290 mm |
| Weight | ~2 kg |
| Compliance | CE (EN 61326, EN 5011, EN 50082-2) |
| Data Interface | Bluetooth |
| Viscosity Compensation | Yes |
| Instrument Type | Oscillating U-tube Digital Density Meter |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Instrument Type | Oscillating U-tube Densimeter |
| Portability | Benchtop (Compact Design) |
| Sample Type | Liquids, Emulsions, Pastes |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | DS7700: ±0.001 g/cm³ |
| DS7800 | ±0.0001 g/cm³ |
| Temperature Range | 10–40 °C |
| Temperature Accuracy | ±0.02 °C |
| Sample Volume | <1 mL |
| Measurement Cycle | 1–3 min (including thermal equilibration) |
| Display | 5.7″ TFT Touchscreen |
| Data Storage | Tamper-Resistant Memory (999 entries) |
| Compliance | ASTM D4052, ISO 12185, USP <841>, Ph. Eur. 2.2.39, JP 2.05, OIML R 22, ICUMSA Methods, FDA 21 CFR Part 11, GLP/GMP Audit Trail Ready |
| Interfaces | RS232, USB, Ethernet |
| Dimensions | 220 × 220 × 430 mm |
| Weight | 5.3 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Hydrom 070 |
| Instrument Type | Density Gradient Tube System |
| Portability | Portable |
| Sample Type | Liquids |
| Temperature Range | 20–60 °C |
| Compliance | Designed for ASTM D1298, ISO 3675 & ISO 12185 compliant density determination |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VDM-250.1N |
| Instrument Type | Portable Immersion Densimeter & Viscometer |
| Density Range | 0–3 g/cm³ (0–3000 kg/m³) |
| Density Accuracy | ±0.0003 or ±0.0005 g/cm³ |
| Density Repeatability | ±0.00015 or ±0.00025 g/cm³ |
| Temperature Range | −40 to +85 °C |
| Temperature Accuracy | ±0.1 or ±0.2 °C |
| Viscosity Range | up to 10,000 mPa·s (cP) |
| Viscosity Accuracy | ±1% of span |
| Viscosity Repeatability | ±0.5% of span |
| Measurement Depth | up to 6 m |
| Display | OLED with backlight |
| Data Storage | 2000 records |
| Communication | Bluetooth & USB |
| Sensor Materials | SS 316L, NiSpan C, or Hastelloy C-22 (optional) |
| Certifications | ATEX, IECEx HazLoc |
| Battery | NiMH 3.6 V, 2500 mAh (≈40 h operation) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VDM-250.2N |
| Instrument Type | Portable immersion densimeter & viscometer |
| Density Range | 0–3 g/cm³ (0–3000 kg/m³) |
| Density Accuracy | ±0.0003 or ±0.0005 g/cm³ |
| Density Repeatability | ±0.00015 or ±0.00025 g/cm³ |
| Temperature Range | −40 to +85 °C |
| Temperature Accuracy | ±0.1 or ±0.2 °C |
| Viscosity Range | up to 10,000 mPa·s (cP) |
| Viscosity Accuracy | ±1% of span |
| Viscosity Repeatability | ±0.5% of span |
| Max. Immersion Depth | 30 m |
| Data Storage | 2000 measurements |
| Communication | Bluetooth & USB |
| Certified | ATEX, IECEx HazLoc |
| Sensor Materials | SS 316L, NiSpan C, Hastelloy C-22 |
| Battery | NiMH 3.6 V, 1500 mAh (≈12 h operation) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VDM-300 heat |
| Density Range | 0.5–3 g/cm³ |
| Density Accuracy | ±0.0002 g/cm³, ±0.0005 g/cm³, or ±0.001 g/cm³ (selectable) |
| Kinematic Viscosity Accuracy | ±1% of reading |
| Dynamic Viscosity Range | 0.2–2000 mPa·s |
| Temperature Range | up to +100 °C |
| Probe Material | 316L stainless steel, nickel-based alloy, Hastelloy C-22 |
| Dimensions | 140 × 100 × 290 mm |
| Weight | ~2 kg |
| Compliance | CE marked per EN 61326, EN 5011, EN 50082-2 |
| Connectivity | Bluetooth to PC and printer |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Category | Domestic (China) |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — corrected per technical specification: 14 kg, fixed installation required) |
| Sample Type | Solid powders, granules, bulk solids, foams, slurries, and filtration media |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium Displacement, ISO 12154:2014 compliant) |
| Volume Range | 0.01–100 cm³ |
| Temperature Range | 5–35 °C |
| Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL |
| Optional Sample Cups | 10 mL, 30 mL, 60 mL |
| Pressure Control | Absolute pressure mode (0–130 kPa), vacuum-assisted degassing |
| Test Gas | 99.99% N₂ or He (user-supplied) |
| Software Interface | Windows 7 or later |
| Communication | RS-232 or USB |
| Power | AC 220 V ±22 V, 50 Hz |
| Dimensions | 485 × 350 × 220 mm (L×W×H) |
| Weight | 14 kg |
| Compliance | GB/T 24586–2009, ISO 12154:2014, ASTM D5550–22 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-1206B |
| Price Range | USD 5,600 – 7,000 (est.) |
| Application Field | General-purpose true density analysis |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — correction per technical specs) |
| Sample Type | Solid materials (powders, granules, monoliths, foams, slurries, filters) |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium displacement, based on ideal gas law) |
| Volume Range | 0.01–100 cm³ |
| Temperature Operating Range | 5–35 °C |
| Density Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL (with interchangeable sample cups: 10 mL, 30 mL, 60 mL) |
| Pressure Control | Absolute pressure mode (vacuum-based), 0–130 kPa absolute |
| Test Gas | 99.99% purity N₂ or He (user-supplied) |
| Data Interface | RS232 or USB |
| Software Platform | Windows 7 or later |
| Power Supply | AC 220 V ±10%, 50 Hz, <200 W (vacuum mode) |
| Dimensions | 485 × 350 × 220 mm |
| Weight | 14 kg |
| Compliance | GB/T 24586–2009, ISO 12154:2014 (gas pycnometry), ASTM D5550–22 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Category | Portable Solid Density Analyzer |
| Measurement Principle | Gas Displacement Pycnometry (ISO 12154:2014, GB/T 24586–2009) |
| Sample Volume Range | 0.01–100 cm³ |
| Temperature Operating Range | 5–35 °C |
| Density Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL (with interchangeable sample cups: 10 mL, 30 mL, 60 mL) |
| Pressure Mode | Absolute Vacuum Mode (0–130 kPa absolute) |
| Test Gas | 99.99% N₂ or He (user-supplied) |
| Data Interface | RS232 or USB |
| Software Platform | Windows 7 or later |
| Power Supply | AC 220 V ±22 V, 50 Hz |
| Vacuum Mode Power Consumption | <200 W |
| Dimensions (L×W×H) | 485 × 350 × 220 mm |
| Weight | 14 kg |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China-made) |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — corrected per technical specification: 14 kg, fixed installation) |
| Sample Type | Solids (powders, granules, bulk solids, foams, filter media, slurries) |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium Displacement, ASTM D5550 / ISO 12154 compliant) |
| Density Range | 0.01–100 g/cm³ |
| Temperature Control Range | 15–39 °C |
| Repeatability | ±0.02% RSD |
| Resolution | 0.00001 g/cm³ |
| Sample Volume Capacity | 0.01–100 cm³ (with interchangeable sample chambers: 10 mL, 30 mL, 60 mL, and fixed 100 mL reference chamber) |
| Test Duration | ~3 min per analysis (fully automated) |
| Pressure Mode | Absolute pressure vacuum system (0–130 kPa absolute), integrated vacuum pump |
| Calibration Standard | Certified stainless steel sphere (included) |
| Software Interface | Windows 7 or later, RS232/USB |
| Compliance | GB/T 24586–2009, ASTM D5550–22, ISO 12154:2014, USP <699> (for density determination in pharmaceutical excipients) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Not Portable — corrected per technical specification: 14 kg, fixed installation required) |
| Sample Type | Solid powders, granules, bulk solids, foams, filters, slurries |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium Displacement, ISO 12154:2014 compliant) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL |
| Optional Sample Cups | 10 mL, 30 mL, 60 mL |
| Volume Range | 0.01–100 cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Temperature Range | 5–35 °C |
| Operating Pressure | Absolute pressure mode, 0–130 kPa |
| Test Gas | 99.99% N₂ or He (user-supplied) |
| Calibration Standard | Certified stainless-steel sphere |
| Data Interface | RS232 or USB |
| Software Platform | Windows 7 or later |
| Power Supply | AC 220 V ±22 V, 50 Hz |
| Power Consumption | <200 W (vacuum mode), <50 W (positive-pressure mode) |
| Dimensions | 485 × 350 × 220 mm (L×W×H) |
| Weight | 14 kg |
| Compliance | GB/T 24586–2009, ISO 12154:2014, ASTM D5550–22 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-A302 |
| Instrument Type | Bulk Density Tester |
| Instrument Class | Portable |
| Measurement Target | Solid Powders & Granules |
| Application Scope | General-purpose bulk density determination of free-flowing and cohesive powders |
| Standard Compliance | GB/T 16913–2008 (Dust Physical Property Testing – Natural Packing Method) |
| Funnel Orifice Diameter | 12.7 mm |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Cone Angle | 60° |
| Cylinder Volume | 100 mL |
| Cylinder & Funnel Material | ASTM A240 Grade 304 Stainless Steel |
| Scraper Blade Width | 25 mm |
| Overall Dimensions | ~160 × 160 × 300 mm |
| Net Weight | 3.7 kg |
| Required External Balance | Capacity ≥ 1000 g, Readability ≤ 0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Bulk Density Tester |
| Design | Portable Benchtop Unit |
| Sample Form | Dry Solid Powders and Granules |
| Compliance Standard | GB/T 16913–2008 (Natural Pile Method) |
| Funnel Orifice Diameter | 12.7 mm |
| Cylinder Volume | 100 mL |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Cone Angle | 60° |
| Cylinder Material | AISI 304 Stainless Steel |
| Scraper & Plug Rod | AISI 304 Stainless Steel |
| Dimensions | ≈ 160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required External Balance | Capacity ≥ 1000 g, Readability ≤ 0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | JL-A302 |
| Price Range | USD 310 – 370 |
| Application Field | General-purpose bulk density measurement |
| Instrument Type | Bulk Density Tester |
| Form Factor | Benchtop (Not Portable — Corrected per ASTM D1895 & ISO 697) |
| Sample Type | Solid Powders and Granules |
| Primary Function | Determination of Uncompacted (Loose) Bulk Density of Free-Flowing Powders |