Dongguan Gaosheng Electronics Precision Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDelta Instruments (delta17)
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDELTA-gs001
Price RangeUSD 2,800 – 7,200
Platform Dimensions700 mm × 800 mm
Max Load Capacity100 kg (customizable)
Peak AccelerationHalf-Sine: 30–600 g
Post-Peak Sawtooth30–100 g
Square Wave (optional)30–120 g
Pulse DurationHalf-Sine: 1–30 ms
Post-Peak Sawtooth6–18 ms
Square Wave (optional)6–18 ms
Acceleration Tolerance≤ ±10%
Velocity Change Tolerance≤ ±10%
Lateral Motion Ratio≤ 10%
Overall Dimensions1300 mm × 1200 mm × 2650 mm
Mass1800 kg
Data Acquisition Channels2
Sampling Rate500 kHz
Max Measurable Acceleration5000 g
Input Voltage Range±10 V<sub>PEAK</sub>
Sensor TypePiezoelectric Charge Output
Sensor ModelB&W 22100
Sensitivity3.93 pC/g
Frequency Range0.5–12 kHz
Acceleration Range±2500 g
Operating Environment−40 °C to +160 °C
Power Supply3-phase AC 380 V ±10%, 5 kVA
Compressed Air0.5–0.8 MPa
Ambient TempRT–40 °C
Relative Humidity<85% RH at 25 °C
MTBF≥5000 h
Half-Sine Generator Duty Cycle≥8000 consecutive impacts
Storage Life (clean, ambient conditions)≥5 years
ComplianceGB/T 2423.5–1995, GJB 150.18A–2009, GJB 360B–2009, IEC 60068-2-27, MIL-STD-810H, MIL-STD-202G, GB/T 18287, GB 31241, JG 541–2005
Software FunctionsShock Response Spectrum (SRS), Pulse Analysis, Damage Boundary Analysis, Time-Domain Impact Response Calculation, FFT, Force–Deformation Correlation (auxiliary)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDELTA Instruments
ModelDELTA-SBT50
TypeElectro-Mechanical Shock Test Table
Max Load Capacity50–500 kg
Standard WaveformHalf-Sine Pulse
ComplianceGB/T 2423.5, GB/T 2423.6, IEC 60068-2-29, GB/T 31467.3, JJG 497
Control SystemPC-Based Closed-Loop Digital Control with Real-Time Acceleration Feedback
Pulse Duration AdjustmentVia Interchangeable Anvil Pads
Peak Acceleration AdjustmentVia Adjustable Drop Height
Automated StopAfter Predefined Impact Count or Time Duration
Data AcquisitionIntegrated Accelerometer, Velocity Change (Δv), Pulse Width, and G-Value Normalization
SafetyMechanical Locking Mechanism for Anvil Pad Replacement
Dual-Mode OperationShock (Single-Impact) and Bump/Collision (Repetitive Impact) Modes
Software FeaturesReal-Time Waveform Display, Tolerance Band Overlay, Exportable CSV/PDF Reports, Audit-Trail-Ready Logging (GLP-Compatible)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDelta Instruments
OriginGuangdong, China
ModelGB/T 12996
Standard ComplianceGB/T 12996–2012, GB/T 13800–2009
Incline Range0° to 10° (continuous, motorized adjustment)
Incline Accuracy≤ ±0.2°
Test Platform Dimensions10 m × 3 m
Friction Force Measurement0–100 N (±1 N accuracy)
Load Mass5 kg ± 0.05 kg
Control InterfaceMicrocomputer-based system with color touch screen
Automatic Stop LogicAngle-triggered termination
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDELTA Instruments
ModelGS-DELTA1079
Voltage Range±10 V
Voltage Resolution0.1 mV
Voltage Accuracy±(1% of Vp-p setting + 2 mVp-p)
Frequency Range0.01 µHz – 5 MHz
Frequency Resolution0.01 µHz
Frequency Accuracy±(3 ppm of setting + 2 pHz)
Lead Configuration12-lead compatible
ComplianceGB 9706.225–2021, IEC 60601-2-25:2011, YY 1079–2008, JJG 1041–2008
ECG SimulationStandard waveform (1333.3 ms period), 6 arrhythmia modes (20–300 bpm), pacing pulse (0.1/1/10 ms, ±0.5%), dual-source composite signal generation (sine + square)
CMRR Test ModuleInput 1–20 Vrms @ 50/60/100/120 Hz
Electrosurgical Interference Test ModuleECG rate ~73 bpm, ECG lead interface provided
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelDELTA1111
QuotationAvailable upon Request
Test StandardsISO 6925, CFR 1630/1631, BS 6307, BS 4790, GB/T 20394–2013, GB/T 11049–2008, GB/T 14768–2015
Sample Size230 mm × 230 mm (8 specimens per test)
Heating SourceHot Metal Nut Method & Hexamethylenetetramine (Urotropine) Pellet Method
IgnitionAutomatic Pulse Ignition
Timing RangeFlame Application Time: 0–99 s/min
Flame Application & Withdrawal Interval1.0–999.9 s (digital preset)
Afterflame Time1.0–999.9 s (digital readout)
Repetition Cycles1–9999 (digital preset)
Test Chamber Dimensions300 mm × 300 mm × 300 mm (W×D×H)
Ventilation Hood Volume2 m³ with Auto-Exhaust & Explosion-Proof Lighting
Exhaust Duct DiameterØ110 mm
Control SystemPLC + 7-inch HMI Touchscreen
Power SupplyAC 220 V ±10%, 50 Hz
Stainless Steel Hot Plate230 mm × 230 mm × 6.5 ±0.5 mm, central aperture Ø205 mm
DesiccantColor-Indicating Silica Gel GPE0038
Safety FeaturesInterlocked Protective Door, Black Interior Finish, Observation Window with Integrated LED Illumination