Empowering Scientific Discovery

Dongguan Pubiao Experimental Equipment Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAB SCIEX
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
Model4500
Instrument TypeTriple Quadrupole Mass Spectrometer
Application ScopeGeneral-Purpose LC-MS/MS
Mass Range1000 Da
Sensitivity (MRM)100:1 (S/N)
Resolution0.5 Da (FWHM)
Mass Accuracy0.1 Da
Operating Pressure Range600 Torr (vacuum system)
Scan Speed12,000 Da/sec
Mass Stability<0.1 Da/24 h
Dynamic Linear Range5 orders of magnitude
MRM Dwell Time1 ms
Ion SourceTurbo V™ with ESI and APCI capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABSCI
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model5500
Instrument TypeTriple Quadrupole (TQ)
Application ScopeGeneral-Purpose
Mass Rangem/z 5–1250
MS/MS Sensitivity (ESI)50 fg, S/N > 500:1
Resolution0.7 amu
Mass Accuracy±0.1 Da/24 h
Polarity Switching Time≤50 ms
Scan Speed≥12,000 amu/s
LC Pressure Capability15,000 psi
Column Temperature Range5–65 °C
Operating Pressure Range1200 psi
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAB SCIEX
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAPI 5000™
Instrument TypeTriple Quadrupole (TQ)
Application ScopeGeneral-Purpose
Mass Range10–1200 m/z
Sensitivity<100.1 fg on-column for selected analytes (e.g., reserpine, caffeine)
ResolutionUnit resolution (0.5–0.7 Da full width at half maximum)
Mass Accuracy≤0.1 Da (calibrated)
Operating Pressure RangeUp to 1200 psi (LC system compatible)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABSCI
OriginUSA
Manufacturer TypeAuthorized Distributor
Instrument TypeTriple Quadrupole
Application ScopeGeneral-Purpose
Mass Range10–2000 m/z
Sensitivity100.1 fg on-column (for reserpine, SRM)
Resolution0.5 Da (unit resolution at peak width at half height)
Mass Accuracy±0.1 Da (external calibration)
Source Pressure1200 Torr (ESI/APCI source operating pressure)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAB SCIEX
OriginUSA
ModelTripleTOF 6600
Instrument TypeQuadrupole-Time-of-Flight (Q-TOF)
Resolution30,000 (FWHM at m/z 1,000)
Sensitivity10.1 fmol (substance P, S/N ≥ 10)
Mass Accuracy< 100 ppm (internal calibration), < 5 ppm (external calibration with lock mass)
Stability≤ 10 ppm RMS over 24 h
Acquisition Rate50 Hz (MS/MS spectra per second)
SWATH™ AcquisitionUp to 200 variable isolation windows per cycle
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAB SCIEX
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAB SCIEX Triple Quad 6500+ + Shimadzu Nexera LC-40BX3
QuotationUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
Instrument TypeTime-of-Flight (TOF) Hybrid Quadrupole-TOF Mass Spectrometer
ModelTripleTOF 6600
Resolution10,000 (FWHM at m/z 956)
Sensitivity≤10 amol β-galactosidase tryptic peptide (S/N ≥10)
Mass Accuracy≤10 ppm RMS (calibrated)
Mass Stability≤10 ppm over 24 h
Acquisition RateUp to 100 Hz MS/MS spectra
Linear Dynamic Range5 orders of magnitude
Q1 m/z RangeUp to 2250 Th
SWATH Window Flexibility2–25 Da variable width, up to 200 windows per cycle
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginMalaysia
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model7850
Instrument TypeQuadrupole ICP-MS
Application EnvironmentLaboratory
Mass Range (amu)5–260
Unit Mass Resolution (amu)0.5
Detection Limit (ng·L⁻¹)10
Sensitivity (Mcps / mg·L⁻¹)10
Short-Term Stability (RSD %)3
Long-Term Stability (RSD %)5
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGCMS-TQ8050
Year of Manufacture2018
ConditionRefurbished & Certified Pre-Owned
ConfigurationComplete Benchtop System with GC, TQMS, Autosampler, and GCMS Insight Software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGCMS-QP2010 Plus
Mass Rangem/z 10–1090
Scan Speed10,000 amu/sec
Vacuum SystemDual-inlet turbo molecular pump (≥360 L/s)
Ion SourceShielded design with uniform temperature distribution
Detection ModeScan/SIM simultaneous acquisition via FASST
Mass AnalyzerMolybdenum quadrupole with pre-rod
Retention Time CorrectionAART (Automatic Adjustment of Retention Time)
SoftwareCompound Composer, Method Package, EPA-compliant modules, GPC-GC/MS integration capability (Prep-Q system)
Warranty1 year
Instrument Age3–5 years
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSPCC
OriginGuangdong, China
Supplier TypeAuthorized Distributor
Product OriginDomestic (China)
Instrument Types SupportedHPLC, GC, LC-MS/MS, GC-MS, AAS, UV-Vis, ICP-OES, FTIR
Service Fee RangeUSD 1,400 – 28,500 (based on instrument count, complexity, and site requirements)
Relocation Experience5+ years
Response Time≤12 hours
Service CoverageDongguan and Greater Pearl River Delta Region
Compliance FrameworkGLP-aligned workflow, ISO/IEC 17025–informed handling protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Instrument TypeOrbitrap Tribrid
ModelFusion Lumos
Resolution30,000 (at m/z 200, MS1)
Mass Accuracy≤10 ppm (internal calibration)
Sensitivity10.1 (fmol-level S/N for standard peptides)
Stability≤10 ppm RMS mass drift over 24 h
Acquisition Rate50 Hz (MS/MS in parallel mode)
Mass Rangem/z 50–6,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Model7890B-7000C
Instrument TypeTriple Quadrupole Mass Spectrometer
GC TypeConventional Gas Chromatograph
Mass Range10,000 m/z
Resolution1000 (FWHM)
Sensitivity300 cps/fA (electron multiplier gain referenced)
Scan Speed15,000 Da/sec
Mass Accuracy±100 ppm (calibrated)
Oven Ramp Rate125 °C/min
Detector Count10 (including HED-EM and optional TCD/ECD)
Pressure Control Precision±0.001 psi
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0