BrandAlpha Moisture
OriginUK
ModelSADPu-D
TypePortable Dew Point Meter
Measurement PrincipleAluminum Oxide Capacitive Sensor
Operating Temperature-20 to +50 °C
Accuracy±2 °C DP
Repeatability±0.5 °C DP
Dew Point RangeStandard –80 to 0 °C DP (0–6000 ppmv, plus extended low-range 0–10 ppmv option)
Response Time<20 s to 90% of final reading
Power Supply6 × C-cell alkaline batteries (≥150 h continuous operation
Weight5.5 kg net / 7 kg gross
Dimensions224 × 202 × 275 mm
Ingress ProtectionIP65
Explosion ProtectionEEx ia IIC T5
Storage Temperature–50 to +70 °C
Humidity Range0–98% RH (non-condensing)
DisplayLCD, dual units (°C DP and ppmv)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlpha Moisture
OriginUnited Kingdom
ModelSADPmini
TypePortable Dew Point Meter
Measurement PrincipleAluminum Oxide Capacitive Sensor
Operating Temperature10–60 °C
Accuracy±2 °C
Repeatability0.2 °C
Resolution0.1 °C or 0.1 ppm(v)
Dew Point Range Options–110 to –20 °C (SR), –100 to 0 °C (PL), –80 to –20 °C (RD), –80 to 0 °C (GY), –80 to +20 °C (BL)
Sampling Temperature–10 to +60 °C
Maximum Operating Pressure< 0.3 kgf/cm² (≈ 30 kPa gauge)
Ingress ProtectionIP54 / NEMA 12
Power SupplyRechargeable Battery (250 h continuous operation)
Data Storage16,000 records
Display128 × 64 pixel LCD
CalibrationFactory-traceable to UKAS/NIST standards
Output OptionsUSB, RS-485, optional 4–20 mA analog output
Gas CompatibilityAir, N₂, CO₂, SF₆, H₂, Ar, and other gases with known molecular weight
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlpha Moisture
OriginUnited Kingdom
ModelDS-1000
Product TypeOnline Dew Point Meter
Measurement PrincipleCapacitive Aluminum Oxide Sensor
Operating Temperature10 to +50 °C
Accuracy±0.1 °C / ±0.1 °F / ±0.1 ppm(v)
Repeatability±0.1 °C / ±0.1 °F / ±0.1 ppm(v)
Dew Point Range (PL Sensor)−110 to +20 °C (0–23,000 ppm(v))
Dew Point Range (BL Sensor)−80 to +20 °C (0–23,000 ppm(v))
Resolution0.1 °C / 0.1 °F / 0.1 ppm(v)
Display4-digit LED
Analog Output4–20 mA
Sample Temperature Range−10 to +50 °C
Maximum Operating Pressure50 bar
Calibration Accuracy±2 °C dew point (NPL-traceable certificate supplied)
Calibration MethodLinear two-point field calibration supported by manufacturer or authorized distributor
Power Supply90–250 VAC, 50/60 Hz
Alarm ConfigurationTwo user-configurable dew point setpoints with front-panel adjustment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1200
Measurement Range0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1% O₂, 0–25% O₂
Accuracy<±1% of reading under stable conditions
Resolution0.01 ppm
Response Time (T₉₀)10 seconds
Operating Temperature5–45 °C
Sample Flow Rate0.5–5 SCFH (recommended: 2 SCFH)
Inlet Pressure5–30 psig (max 100 psig)
Outlet Pressureambient
Barometric & Temperature Compensationyes
Power Sourcerechargeable battery (60-day runtime per charge)
Output Signals4–20 mA, 0–1 V analog
Sample CompatibilityH₂, He, CO₂, hydrocarbons, inert gases, and mixed process gases
Enclosure RatingClass I, Division 1, Groups A, B, C, D (UL/cUL listed)
Dimensions9.6" × 9" × 3" (L×W×H)
Weight12 lbs (≈5.4 kg)
Connection1/8" Swagelok compression fitting
Data Interfaceanalog only (no digital bus)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAboni
OriginGermany
ModelHT3
Measurement PrincipleCalcium Hydride Reaction (Hydrogen Gas Evolution)
Sample Capacity0.01–50 g (up to 100 g depending on density & moisture content)
Sample Volume~50 mL
Detection Range0.2–30 mg H₂O
Resolution±0.1 mg H₂O (at 1 mg) to ±0.3 mg H₂O (at 20 mg)
Heating Temperature Range50–210 °C (1 °C increments)
ReagentCalcium Hydride (CaH₂) powder, ~0.1 g per test
Environmental MonitoringTemperature (±0.1 °C), Relative Humidity (0–100 % RH, ±0.1 %), Atmospheric Pressure (700–1100 mbar, ±0.1 mbar)
Power Supply230 VAC, 1.6 A
Dimensions285 (H) × 170 (W) × 250 (D) mm
Weight4.6 kg
InterfaceRS232 or USB
ComplianceISO 15512
Added to wishlistRemoved from wishlist 0
Add to compare
Brand4FD
OriginUSA
ModelBT200
Instrument TypeOnline
Measurement Range0–1 ppmv to 0–20 vol.%
Detection Limit0.0001 ppmv (at 0–1 ppmv range)
Response Time (t95)<30 s (low-concentration mode)
Zero Drift CompensationAutomatic zero-cleaning cycle
Resolution0.0001 ppmv
Analog Output4–20 mA or 0–10 V
Power SupplyDC 12 V, 1.5 A (AC 100–240 V, 50–60 Hz)
Operating Temperature0–40 °C
Operating Humidity<90% RH (non-condensing)
UV Lamp Lifetime20,000 hours (50% output degradation)
Calibration Interval12 months
Accuracy±1% of reading or ±10% of full scale, whichever is greater (within validated range
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelQUICK 1
PricingUpon Request
Thermal Conductivity Range (VIP samples)0.001–0.015 W/(m·K)
Thermal Conductivity Range (Homogeneous samples)0.03–10.0 W/(m·K)
Repeatability (VIP)±5% or ±0.001 W/(m·K), whichever is greater
Repeatability (Homogeneous)±5%
AccuracyTraceable to NIST-traceable reference standards
Operating Temperature+5 °C to +40 °C
Measurement Time≤60 s per sample
Data Storage Capacity99 measurements
Power SupplyAC adapter, 100–240 V AC, 50/60 Hz
Dimensions250 × 200 × 90 mm
Weight4 kg