Add to compare
BrandAlpha Moisture
OriginUK
ModelSADPu-D
TypePortable Dew Point Meter
Measurement PrincipleAluminum Oxide Capacitive Sensor
Operating Temperature-20 to +50 °C
Accuracy±2 °C DP
Repeatability±0.5 °C DP
Dew Point RangeStandard –80 to 0 °C DP (0–6000 ppmv, plus extended low-range 0–10 ppmv option)
Response Time<20 s to 90% of final reading
Power Supply6 × C-cell alkaline batteries (≥150 h continuous operation
Weight5.5 kg net / 7 kg gross
Dimensions224 × 202 × 275 mm
Ingress ProtectionIP65
Explosion ProtectionEEx ia IIC T5
Storage Temperature–50 to +70 °C
Humidity Range0–98% RH (non-condensing)
DisplayLCD, dual units (°C DP and ppmv)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlpha Moisture
OriginUnited Kingdom
ModelSADPmini
TypePortable Dew Point Meter
Measurement PrincipleAluminum Oxide Capacitive Sensor
Operating Temperature10–60 °C
Accuracy±2 °C
Repeatability0.2 °C
Resolution0.1 °C or 0.1 ppm(v)
Dew Point Range Options–110 to –20 °C (SR), –100 to 0 °C (PL), –80 to –20 °C (RD), –80 to 0 °C (GY), –80 to +20 °C (BL)
Sampling Temperature–10 to +60 °C
Maximum Operating Pressure< 0.3 kgf/cm² (≈ 30 kPa gauge)
Ingress ProtectionIP54 / NEMA 12
Power SupplyRechargeable Battery (250 h continuous operation)
Data Storage16,000 records
Display128 × 64 pixel LCD
CalibrationFactory-traceable to UKAS/NIST standards
Output OptionsUSB, RS-485, optional 4–20 mA analog output
Gas CompatibilityAir, N₂, CO₂, SF₆, H₂, Ar, and other gases with known molecular weight
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlpha Moisture
OriginUnited Kingdom
ModelDS-1000
Product TypeOnline Dew Point Meter
Measurement PrincipleCapacitive Aluminum Oxide Sensor
Operating Temperature10 to +50 °C
Accuracy±0.1 °C / ±0.1 °F / ±0.1 ppm(v)
Repeatability±0.1 °C / ±0.1 °F / ±0.1 ppm(v)
Dew Point Range (PL Sensor)−110 to +20 °C (0–23,000 ppm(v))
Dew Point Range (BL Sensor)−80 to +20 °C (0–23,000 ppm(v))
Resolution0.1 °C / 0.1 °F / 0.1 ppm(v)
Display4-digit LED
Analog Output4–20 mA
Sample Temperature Range−10 to +50 °C
Maximum Operating Pressure50 bar
Calibration Accuracy±2 °C dew point (NPL-traceable certificate supplied)
Calibration MethodLinear two-point field calibration supported by manufacturer or authorized distributor
Power Supply90–250 VAC, 50/60 Hz
Alarm ConfigurationTwo user-configurable dew point setpoints with front-panel adjustment