Electrochemical Workstation
Filter
Showing 1–30 of 107 results
| Brand | Admiral |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Squidstat Ace |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | 1 |
| Current Range | ±1 A |
| Current Resolution | 3 pA (0.003% of full scale) |
| Potential Range | ±10 V |
| Potential Resolution | 300 µV |
| Time Resolution | 10 µs |
| AC Impedance Capability | Not Supported |
| Supported DC Techniques | Cyclic Voltammetry, Linear Sweep Voltammetry, Open Circuit Potential, Chronoamperometry/Chronocoulometry, Linear Sweep Chronoamperometry, Chronopotentiometry, Differential Pulse Voltammetry, Normal Pulse Voltammetry, Square Wave Voltammetry, Relaxation Voltammetry, Staircase Voltammetry, Tafel Scan, Pulse Plating, Stripping Voltammetry |
| Supported Battery Testing Modes | Galvanostatic Charge/Discharge, Potentiostatic Charge/Discharge, Constant Resistance Discharge, Constant Power Discharge, High-Power Discharge, Capacity-Limited Cycling, Steady-State I–V Profiling |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Penta 5A |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±5 A |
| Current Accuracy | 0.1% of range, minimum 1 nA |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Current Resolution | down to 30 pA |
| Voltage Resolution | 15 µV |
| Voltage Accuracy | 0.1% of setpoint, minimum 1 mV |
| Input Impedance | 10 TΩ |
| Supported DC Techniques | CV, LSV, OCP, Tafel, CA, CP, DPV, NPV, SWV, Staircase Voltammetry, GITT, PITT |
| Supported AC Techniques | Potentiostatic EIS, Galvanostatic EIS, Mott-Schottky (1/C² vs. V) |
| Battery Testing Modes | CC-CV, CC-CV-EIS, CP/CR |
| Data Output | SOC, dQ/dV, Coulombic Efficiency, Energy Efficiency, Cycle Statistics, Capacity Statistics |
| Onboard Storage | 16 GB flash memory |
| Data Format | CSV (auto-saved, power-fail resilient) |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Model | Squidstat Plus |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±1 A |
| Potential Accuracy | ±300 µV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Current Resolution | 3 pA (0.003% of full scale) |
| Voltage Resolution | 300 µV |
| Data Storage | Internal 16 GB Flash Memory |
| Output Format | CSV (up to millions of data points) |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Model | Squidstat Plus |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±0.2% of reading (typ.) |
| Potential Accuracy | ±300 µV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Current Resolution | 3 pA (at 1 A range) |
| Potential Resolution | 15 µV |
| Onboard Memory | 16 GB internal storage |
| Data Format | CSV export |
| Supported DC Techniques | CV, LSV, OCP, Tafel, CA, CP, DPV, NPV, SWV, RRDE, Staircase Voltammetry, GITT, PITT |
| Supported AC Techniques | Potentiostatic EIS, Galvanostatic EIS, Mott-Schottky (1/C² vs. E) |
| Battery Testing Modes | CC-CV, CC-CV-EIS, CP/CR, dQ/dV analysis, Coulombic & energy efficiency calculation |
| Brand | AIWEI |
|---|---|
| Origin | Tianjin, China |
| Model | 30kW Fuel Cell Stack Test Station |
| Instrument Type | Electrochemical Workstation |
| Current Range | 0–1500 A |
| Power Rating | 30 kW (DC output) |
| Electronic Load Capacity | 36 kW (optional) |
| Voltage Range | 0–400 V DC |
| AC Input | Three-phase 220/380 VAC, Max 150 A |
| Dimensions (W×D×H) | 1300 × 2500 × 2000 mm |
| Mass Flow Control | Anode (H₂/N₂) up to 500 SLPM |
| Humidification | Direct-injection humidifier with temperature-controlled heating chamber & pressure pump |
| Backpressure Control | 0–3.5 bar, proportional control, ΔP < 2 kPa at max flow |
| Cooling System | 100 L water reservoir, 0–95 °C heating/cooling, conductivity monitoring |
| Software Platform | LabVIEW-based real-time control & data acquisition, ASTM/ISO-compliant test sequencing, FDA 21 CFR Part 11-ready audit trail (optional) |
| Brand | AIWEI |
|---|---|
| Model | 50–200 kW Electrochemical Workstation |
| Type | Regenerative/Energy-Dissipative Stack Test System |
| Power Range | 50–200 kW |
| Current Range | ±1000 A / ±1500 A |
| Voltage Range | 0–400 V / 0–600 V / 0–800 V |
| Enclosure Dimensions | 1500(W) × 3300(D) × 2000(H) mm |
| Input Power | 3-phase 220 VAC or 380 VAC, up to 200 A |
| Anode Gas Flow Control | H₂/N₂, up to 2000/4000 SLPM |
| Cathode Gas Flow Control | Air/N₂, up to 6000/12000 SLPM |
| Humidification | Direct-injection humidifier with temperature-controlled heating chamber & pressure pump |
| Backpressure Control | 0–3.5 bar, proportional control, ΔP < 2 kPa at max flow |
| Cooling/Heating | 100 L water reservoir, 20–95 °C temperature range, conductivity monitoring |
| DI Water System | Integrated deionization filtration with auto-regeneration |
| Condensate Management | Automated drainage with heat-exchange cooling loop |
| Preheater | SUS 316 tubing (anode: 1.5", cathode: 2"), inline gas temperature control |
| Data Acquisition | LabVIEW-based platform with DAQ integration, real-time visualization, automated protocol execution, load-following control, and customizable test sequencing |
| Optional Modules | Individual cell voltage monitoring (±5 V per cell), multi-channel EIS (10 mHz–10 kHz), HFR/IR drop analysis, combined IV + EIS operation |
| Brand | AIWEI |
|---|---|
| Model | 7–10 kW Fuel Cell Stack Test Station |
| Category | Electrochemical Workstation |
| Power Rating | 7–10 kW |
| Current Range | ±600 A / ±1000 A |
| Voltage Range | 0–60 V / 0–120 V / 0–400 V (configurable) |
| Cooling | Liquid-cooled electronic load modules (9 kW / 12 kW) |
| Enclosure | Floor-standing modular cabinet (1100 W × 1800 D × 2000 H mm) |
| Input Power | 3-phase 220 VAC or 380 VAC, max. 75 A |
| Anode Gas Flow Control | H₂/N₂, up to 150 SLPM |
| Cathode Gas Flow Control | Air/N₂, up to 500 SLPM |
| Humidification | Bubble-type or membrane-type humidifiers with temperature-controlled water bath, liquid-level monitoring, wet/bypass mode |
| Water Management | Automated DI-water injection, 50 L thermal reservoir with heating (up to 95 °C) and cooling, conductivity monitoring, integrated deionization filtration |
| Backpressure Control | 0–3.5 bar, proportional pressure regulation, ΔP < 2 kPa at max flow, differential pressure control for anode/cathode inlet/outlet |
| Preheater | SUS316 tubing (anode: 1/2″, cathode: 3/4″), inline gas temperature control |
| Condensate Handling | Auto-drain water traps with heat sink & fan cooling |
| Software | LabVIEW-based control suite with real-time DAQ, automated test protocols (load-following, polarization, EIS), GLP-compliant audit trail (optional), FDA 21 CFR Part 11 ready (with optional digital signature module) |
| Optional Modules | Individual cell voltage monitoring (±5 V per cell, channel-selectable), multi-channel EIS (10 mHz–10 kHz), HFR/IR/Ohmic resistance extraction, stack discharge resistive load bank (1–2 kW) |
| Brand | AIWEI |
|---|---|
| Origin | Tianjin, China |
| Model | FCEL-50 / FCEL-100 / FCEL-150 / FCDC-250 |
| Current Range | 167 A / 334 A / 500 A / 834 A |
| Current Accuracy | ±0.2% FS + 5 digits |
| Voltage Accuracy | ±0.2% FS |
| Voltage Range | 24–800 V DC |
| Insulation Resistance Measurement Range | 1 kΩ–1 MΩ |
| Insulation Resistance Accuracy | ±0.2% FS |
| Operating Quadrants | Four-quadrant (bidirectional energy flow) |
| Communication Interfaces | RS485, Ethernet, CAN 2.0B |
| Compliance | GB/T 24554–2009 |
| Brand | AIWEI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HMS |
| Instrument Type | Electrochemical Workstation |
| Voltage Compatibility | 12 V & 24 V DC |
| Pressure Rating Compatibility | 35 MPa & 70 MPa Cylindrical Valve Testing |
| CAN Channels | 2 × CAN 2.0B |
| Digital Input (DI) Channels | 16 (12/24 V compatible) |
| Analog Output (AO) Channels | 24 (0–5 V, 0–V range) |
| PWM Outputs | 4 (12/24 V compatible) |
| Digital Output (DO) Channels | 6 |
| Power Input | 9–36 V DC / 20 A |
| DTC Strategy Emulation | Yes |
| Control Command Emulation | Vehicle ECU & FCU Command Simulation |
| HIL Integration | Fully Compatible |
| Offline Production Test Support | Yes |
| DBC File Import | Supported |
| Protocol Configuration | User-Configurable Multi-Protocol Stack |
| Brand | AIWEI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ITS550-500 |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | 0–500 A or 0–1000 A |
| Current Accuracy | ±0.05% FS @ 1000 A |
| Potential Accuracy | 0.1% RDG |
| EIS Frequency Range | 10 Hz to 1.5 MHz |
| Voltage Input Range (Stack) | 500 V or 1000 V |
| Cell Voltage Inputs (Optional) | 5 channels, selectable ranges: 5 V / 50 V / 100 V / 200 V |
| ADC Resolution | 24-bit |
| Maximum Sampling Rate | 100 kHz |
| Voltage Measurement Accuracy | 0.1% RDG |
| Current Measurement Accuracy | ±0.05% FS @ 1000 A |
| AC Excitation Current Range | 1–50 A |
| AC Excitation Accuracy | 0.2% RDG + 0.1% FS |
| Impedance Measurement Range (per cell) | 0.1 mΩ to 15 mΩ |
| Common-Mode Withstand Voltage | 1000 V DC |
| Rated Supply | 220 V AC, 50 Hz |
| Operating Temperature | 0–40 °C |
| Brand | AIWEI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PEMFC Fuel Cell Test Station |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±80 A / ±240 A |
| Brand | AIWEI |
|---|---|
| Origin | Tianjin, China |
| Model | SF25K-PE / SF30K-PE / SF50K-PE / SF100K-PE / SF150K-PE / SF200K-PE / SF250K-PE / SF300K-PE |
| Power Range | 25–300 kW |
| Channel Configuration | Single-channel electrochemical workstation |
| Current Range | 100 A / 300 A / 600 A / 1000 A |
| Anode Gas Flow (H₂/N₂) | 500–6000 slpm |
| Cathode Gas Flow (Air/N₂) | 500–22,000 slpm |
| Humidification Temperature Range | RT–95 °C |
| Dew Point Control Accuracy | ±1 °C |
| Back Pressure Control Range | up to 3.5 bar (±2 kPa stability) |
| Voltage Monitoring Channels | up to 1000 cells |
| EIS Frequency Range (optional) | 10 mHz–10 kHz |
| MFC Accuracy | ±0.8% of reading + 0.2% of full scale |
| Flow Turndown Ratio | 100:1 |
| Exhaust Cooling & Condensate Capture | Integrated |
| Thermal Management | Air-cooled or water-cooled stack interface with independent heating/cooling control |
| Brand | AIWEI |
|---|---|
| Origin | Tianjin, China |
| Model | SOFC-1000 |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Accuracy | ±0.01 mA |
| Potential Accuracy | ±1 mV |
| Furnace Power | 2 kW |
| Max Operating Temperature | 1000 °C |
| Gas Control | Multi-channel Mass Flow Controllers (O₂, Air, N₂, H₂) |
| Humidification | Optional Bubbling-Type Humidifier |
| Load Capability | Button-cell-compatible Electronic Load |
| Software | Fully Automated Control & Real-time Monitoring Suite |
| Brand | AIWEI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FS-SOFC-1000 |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Accuracy | ±0.1 mA |
| Potential Accuracy | ±1 mV |
| Maximum Furnace Power | 22 kW |
| Max Operating Temperature | 1000 °C |
| Internal Chamber Dimensions | 500 × 550 × 500 mm |
| Load Capacity | Up to 5 kW Electronic Load |
| Gas Control | Multi-channel Mass Flow Controllers (O₂, Air, N₂, H₂, etc.) |
| Humidification | Optional Bubble-Type Humidifier |
| Temperature Ramp Rate | Programmable Heating/Cooling Control |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Model 2325 |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | ±50 mA |
| Current Resolution | 1 × 10⁻⁷ A (100 fA) |
| Potential Accuracy | ±4.0 mV |
| Potentiostatic Range | ±4.0 V |
| Dual-Channel Capability | Yes |
| Impedance Spectroscopy Support | Not Integrated |
| Dimensions | 220 × 150 × 55 mm |
| Weight | 1.2 kg |
| Interface | USB 2.0 |
| Operating System Compatibility | Windows 7/10/11 (32 & 64-bit) |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Model | PARSTAT 2273 |
| Instrument Type | Electrochemical Workstation |
| Current Range | 12 decades, 2 A to 40 pA |
| Current Accuracy | <0.4% (full scale, 20 µA–2 A) |
| Potential Accuracy | ±10 V |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±2 A (optional ±20 A) |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Current Resolution | 1.2 fA |
| Input Impedance | >10¹³ Ω |
| Capacitance | <5 pF |
| Slew Rate | >15 V/µs |
| Rise Time | <250 ns |
| Minimum Time Resolution | 20 µs |
| Minimum Potential Step | 2.5 µV |
| Noise | <50 µV RMS (typical) |
| IR Compensation | Positive feedback (2 Ω to 2000 MΩ) |
| Current Interruption | 16-bit DAC |
| Voltage Output Range | ±100 V |
| Power Amplifier Output | ±100 V / ±2 A |
| Bandwidth | >15 MHz (3 dB) |
| Software | PowerSuite (PowerCV, PowerEIS, PowerPULSE, PowerSTEP, PowerCORR, PowerSINE) |
| Interface | USB |
| Operating System | Windows 98/2000/NT/XP/Vista/7 |
| Dimensions | 58 cm W × 47.6 cm D × 22.9 cm H |
| Weight | 31 kg |
| Operating Temperature | 0–50 °C (ideal at 25 °C) |
| Relative Humidity | ≤95% non-condensing |
| Altitude | up to 2000 m |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | Model 263A Potentiostat/Galvanostat |
| Instrument Type | Benchtop Electrochemical Workstation |
| Current Range | 7 decades, 100 mA to 100 nA |
| Current Resolution | 2 pA (min) |
| Potential Range | ±20 V |
| Compliance Voltage | ±20 V |
| Slew Rate | >1 V/µs |
| Rise Time | <1 µs |
| Input Impedance | >10¹² Ω in parallel with <20 pF |
| Electrometer Input Bias Current | <50 pA at 25°C |
| Minimum Time Resolution | 30 µs |
| Minimum Potential Step | 250 µV |
| Noise | <50 µV rms (typical) |
| EIS Frequency Range | Up to 100 kHz (with optional EIS module) |
| Communication Interfaces | IEEE-488 (GPIB), RS-232C |
| Software | PowerSuite (PowerSINE, PowerCORR, PowerCV, PowerSTEP) |
| Operating Temperature | 0–50 °C |
| Dimensions | 44.5 × 47.0 × 14.0 cm (W×D×H) |
| Weight | 16 kg |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | ParStat 4000 |
| Current Range | ±4 A (standard), ±20 A (optional) |
| Current Resolution | 1.2 fA (at 40 pA range) |
| Current Accuracy | ±0.5% ±4 pA (40–200 pA), ±0.2% of reading ±0.2% of range (2 nA–20 A) |
| Potential Range | ±10 V |
| Potential Accuracy | ±0.2% of reading ±2 mV |
| Potentiostatic Bandwidth | 3.75 MHz |
| EIS Frequency Range | 10 µHz to 5 MHz |
| Sampling Rate | 1 MS/s (synchronized potential/current/auxiliary), 500 kS/s (3 × 16-bit ADC) |
| Input Impedance | ≥10¹³ Ω |
| Leakage Current | ≤2 pA (at <25°C) |
| CMRR | 60 dB @ 100 kHz |
| Compliance Voltage | ±48 V |
| Rise Time (−1.0 V to +1.0 V) | <100 ns |
| Scan Rate | up to 10 kV/s (10 mV step) |
| iR Compensation | Positive feedback & dynamic iR compensation |
| Operating Temperature | 10–50°C |
| Dimensions (L×W×H) | 515 × 490 × 195 mm |
| Weight | 23 kg |
| Certifications | CE compliant |
| Brand | AMETEK–Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ParSTAT MC Multi-Channel Electrochemical Workstation |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±2 A (standard) |
| Current Accuracy | 20 nA–2 A: ±0.2% of reading or ±0.2% of range |
| 4 nA | <0.5% ±20 pA |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | AMETEK-Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VersaSTAT 3 Electrochemical Workstation |
| Current Range | ±650 mA (standard), ±2 A (internal optional) |
| Current Accuracy | ±0.2% of reading or ±0.2% of range |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | VersaSTAT 3F Electrochemical Workstation |
| Current Range | ±650 mA (standard), ±2 A (internal optional) |
| Current Accuracy | ±0.2% of reading + ±0.2% of range (20 nA to 2 A) |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Floating Ground Architecture | Yes (isolated electrode connections and rear-panel interfaces) |
| Data Acquisition | 3 × 16-bit, 500 kS/s |
| Input Impedance | ≥10¹² Ω |
| Leakage Current | ≤5 pA at <25°C |
| CMRR | 60 dB @ 100 kHz (typical) |
| Compliance | CE certified, compatible with GLP/GMP environments requiring audit-trail-capable software (via VersaStudio with optional 21 CFR Part 11 modules) |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Model | VersaSTAT 4 Electrochemical Workstation |
| Current Range | ±1 A (standard), ±2 A (internal optional) |
| Current Accuracy | <0.5% ±20 pA at 4 nA |
| Potential Accuracy | ±0.2% of reading ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | Metrohm Autolab |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Model | AUT-RDE |
| Rotation Speed Range | 0–10,000 rpm (1 rpm step size, acceleration: 4,000 rpm/s) |
| Speed Control | Manual or external potentiostat-triggered (e.g., Autolab, CHI, Biologic) |
| Speed Feedback | Integrated optical encoder with closed-loop control (±2 rpm accuracy at 10,000 rpm) |
| Contact Method | Dual-seal mercury pool (liquid Hg-based conduction, no carbon brushes required) |
| Sealing | Fully sealed rotating assembly immersed in electrolyte cell |
| Electrode Head Compatibility | Interchangeable RRDE and RDE heads |
| RRDE Head Options | Pt/Pt, Au/Pt, GC/Pt |
| Collection Efficiency | 24.9% (calibrated per ASTM D3765-18 practice) |
| Disk-Ring Gap | 375 µm |
| Max Current Rating | 500 mA |
| Footprint | Compact design optimized for glovebox integration (W × D × H: 185 × 160 × 320 mm) |
| Brand | Autolab |
|---|---|
| Origin | Imported (Netherlands) |
| Instrument Type | Electrochemical Impedance Spectroscopy (EIS) Control & Analysis Software |
| Frequency Range | 10 Hz – 1 MHz (single-sweep, no segmentation required) |
| Supported Measurement Modes | Potentiostatic EIS, Galvanostatic EIS, Potential Sweep EIS, Current Sweep EIS, Time-Resolved EIS |
| Data Visualization | Nyquist, Bode ( |
| Curve Fitting Engine | EQUIVCRT-based equivalent circuit modeling |
| Validation Tools | Kramers–Kronig transform consistency testing |
| Compliance | Fully compatible with Autolab PGSTAT series potentiostats/galvanostats |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | DiLiCo CURR TEMP |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A/cm² |
| Current Accuracy | ±0.01 A (1% of reading) |
| Voltage Range | ≤2.5 V |
| Voltage Resolution | Not specified |
| Potentiostatic Range | 25 V |
| AC Impedance Frequency Range | 10 Hz |
| Temperature Range | ≤120 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Scan Interval | 2.0 s |
| Sensor Array | 48 nodes (6 × 8) |
| Node Size | 7 mm × 7 mm (0.5 cm²) |
| Node Material | Gold-plated |
| Communication Interface | CAN, USB |
| External Temperature Inputs | Up to 5 (PT-100/PT-500/PT-1000) |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | QCF25 |
| Instrument Type | Electrochemical Workstation Accessory |
| Current Range | ±5 A |
| Current Accuracy | ±0.1% of full scale |
| Potential Accuracy | ±15–32 µV |
| Potentiostatic Range | ±25 V |
| EIS Frequency Range | 10 Hz – 1 MHz (system-dependent, requires compatible potentiostat) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | FlexP 0160 |
| Current Range | ±50 A per channel (up to ±200 A with 4-channel parallel configuration) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz – 1 MHz |
| Voltage Compliance Range | 1–60 V |
| Voltage Accuracy | 0.2% of reading ± 0.1% FS |
| Current Accuracy (high-current mode) | 0.2% of reading ± 0.1% FS up to 50 A |
| Slew Rate | 1 V/μs |
| Rise/Fall Time | 20 μs |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | HCP-803 |
| Current Range | ±80 A |
| Current Resolution | 760 pA (1 nA–400 nA range) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| Dynamic Potential Resolution | 300 µV (adjustable down to 5 µV) |
| EIS Frequency Range | 10 µHz–1 MHz (standard), 10 µHz–10 kHz (with 80 A booster) |
| Booster Module | Removable high-current extension unit |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | HCV-3048 |
| Current Range | ±30 A (per channel), up to ±120 A (4-channel parallel operation) |
| Current Accuracy | 0.1–0.3% (range + reading) |
| Potential Accuracy | <5 mV (on ±2.5 V range) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Voltage Range | 0–48 V |
| Voltage Accuracy | 0.03% (range + reading) |
| Slew Rate | >20 V/µs |
| Rise/Fall Time | <3 µs (0–48 V step) |
| Input Impedance | 100 GΩ |
| Bandwidth | 800 kHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | M470 |
| Instrument Type | Scanning Electrochemical Workstation |
| Current Range | 1 pA – 10 A |
| Current Accuracy | ±0.0033% of reading |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Scan Range (X/Y/Z) | >100 mm |
| Closed-Loop Positioning Resolution | 0.1 nm |
| Spatial Resolution (X/Y/Z) | 20 nm |
| Max Scan Speed | 12.5 mm/s |
| ADC/DAC Resolution | 32-bit @ up to 40 MHz |
| Piezo Vibration Range | 20 nm – 2 µm (peak-to-peak, 1 nm step) |
| Piezo Minimum Vibration Resolution | 0.12 nm (16-bit DAC, 4 µm range) |
| Piezo Extension | 100 µm |
| Piezo Positioning Resolution | 0.09 nm (20-bit DAC, 100 µm range) |