Electrochemical Workstation
Filter
Showing 61–90 of 167 results
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Interface 1000 |
| Current Range | 100 pA – 1 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±12 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Potentiostat Architecture | Floating (True Ground-Independent) |
| Voltage Compliance | ±22 V |
| Potential Resolution | 1 µV |
| Current Resolution | 3.3 fA |
| Built-in FRA | Yes, integrated up to 1 MHz |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Interface 1010B |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | ±1 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±4 mV |
| Potentiostatic Range | ±12 V |
| EIS Frequency Range | 10 µHz – 20 kHz |
| Electrode Configuration | 2-, 3-, and 4-electrode systems |
| Isolation | Galvanically isolated floating ground |
| Weight | 3 kg (6.6 lbs) |
| Connectivity | USB 2.0 (Windows-compatible) |
| Signal Processing | DSP-based oversampling for enhanced SNR and capacitance resolution |
| iR Compensation | Current-interrupt method with auxiliary I/O support |
| Expansion I/O | Analog voltage output, analog current output, external trigger input, digital I/O |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Interface 1010E |
| Instrument Type | Electrochemical Workstation |
| Channel Configuration | Dual Independent Potentiostatic Channels |
| Current Range | ±10 nA to ±1 A (9 decades) |
| Current Accuracy | ±5 pA ±0.3% of reading |
| Potential Accuracy | ±1 mV ±0.2% of reading |
| Potentiostatic Range | ±12 V |
| Electrochemical Impedance Spectroscopy (EIS) Frequency Range | 10 µHz – 2 MHz |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Interface 1010E |
| Instrument Type | Potentiostat/Galvanostat/ZRA |
| Channel Architecture | Multi-channel, electrically isolated and floating |
| Current Range | 10 nA to 10 mA (9 decades) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±4 mV (not ±4.0 V — corrected per industry standard spec) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Input Noise | <20 µV RMS (typical, 10 Hz–100 kHz bandwidth) |
| Weight | 2.0 kg |
| Portability | Benchtop-portable with integrated shielding and battery-compatible operation |
| Compliance | Meets IEC 61326-1 (EMC), CE, RoHS |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Interface 5000 |
| Current Range | ±5 A |
| Current Resolution | < 20 pA |
| Potential Accuracy | 1 µV |
| Potentiostatic Range | ±6 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Interface Bipotentiostats |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±5 A |
| Current Resolution | 5 pA |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±12 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Interface |
| Instrument Type | Electrochemical Workstation |
| Number of Channels | Up to 16 Independent Channels |
| Current Range | 100 pA – 1 A (extendable to 5 A) |
| Current Accuracy | ±0.2% of reading or ±5 pA (whichever is greater) |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±12 V (±22 V with external booster) |
| Potential Resolution | 1 µV |
| Current Resolution | 3.3 fA |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Floating Ground Architecture | Yes |
| Software Suite | PWR800, Echem Analyst, Framework™ (with GLP-compliant audit trail and 21 CFR Part 11 support) |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | LPI1010 |
| Instrument Type | Portable Electrochemical Workstation Interface |
| Current Range | ±10 mA |
| Current Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±10 V (configurable up to ±100 V or ±1000 V with optional variants) |
| Voltage Control Modes | 10 V / 100 V / 1000 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz (measurement bandwidth limited by external power supply or electronic load) |
| Weight | 1 kg |
| Electrode Cable Length | 1 m |
| Signal Output/Input Interface | BNC, ±10 V full-scale |
| Operating Modes | Galvanostatic EIS, Hybrid EIS |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MegaEIS |
| Instrument Type | Electrochemical Workstation |
| Number of Channels | Up to 1000 simultaneous EIS channels |
| Current Range | ±2000 A |
| Current Accuracy | ±0.1 % of reading + 0.5 % of range |
| Potential Accuracy | ±0.1 % of reading + 0.1 % of range |
| Potentiostatic Range | ±1000 V |
| EIS Frequency Range | 1 mHz – 100 kHz |
| Internal Power Dissipation | Up to 20 kW per module |
| Cooling | Water-cooled |
| ADC Resolution | 24-bit (DC), 24-bit @ up to 1.25 MSps (EIS) |
| Input Protection | IP20 |
| Rack Mount | 19-inch modular cabinet |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | PTC-05100EW |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±100 A |
| Current Accuracy | ±0.1% of reading |
| Potential Accuracy | ±0.1% of reading |
| Potentiostatic Range | ±5 V |
| EIS Frequency Range | 1 mHz – 100 kHz |
| Maximum Power Output | 1000 W |
| Cooling Method | Water-Cooled |
| Interface | USB 2.0 |
| Software Compatibility | Windows OS, TCP/IP Server, NI LabVIEW Drivers |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | PTC-1020E |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±20 A |
| Current Accuracy | ±0.1% of reading |
| Potential Accuracy | ±0.1% of reading |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 1 mHz – 100 kHz |
| Maximum Power Output | 500 W |
| Current Ranges | 20 mA / 200 mA / 2 A / 20 A (auto-ranging) |
| EIS Amplitude | 1–1000 mV (up to 10 A peak current below 1 kHz) |
| Cooling Method | Forced-air |
| Interface | USB 2.0 |
| Software Compatibility | Windows OS, TCP/IP server support, NI LabVIEW drivers available on request |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Reference 3000AE |
| Current Range | 3 pA – 3 A |
| Current Accuracy | ±0.2% of reading or ±10 pA (whichever is greater) |
| Potential Accuracy | ±0.2% of setting range or ±1 mV |
| Potentiostatic Range | ±32 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Input Impedance | >10¹⁴ Ω |
| Potential Resolution | 1 µV (high-resolution mode) |
| Sampling Rate | 300,000 points/sec |
| IR Compensation | Current Interruption & Positive Feedback |
| Auxiliary Voltage Inputs | Up to 8-channel serial potentiometry option available |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Reference 600 |
| Instrument Type | Electrochemical Workstation |
| Current Range | 600 fA – 600 mA |
| Current Accuracy | ±10 pA or ±0.3% of reading |
| Potential Accuracy | ±1 mV or ±0.2% of range |
| Potentiostatic Range | ±22 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Potential Resolution | 1 µV |
| Current Resolution | 20 aA |
| Input Bias Current | <5 pA (typ. <2 pA) |
| Maximum Output Current | ±600 mA |
| Cell Voltage Compliance | ±22 V |
| Applied Voltage Range | ±11 V |
| Sampling Rate | 300 kS/s |
| Floating Ground Architecture | Yes |
| EIS Excitation | Direct Digital Synthesis (DDS) with sub-harmonic sampling |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | Reference 600 Plus |
| Channel Configuration | Multi-channel workstation |
| Current Range | ±600 mA |
| Current Resolution | 20 aA |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±22 V |
| EIS Frequency Range | 10 µHz – 5 MHz |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Model | MSK-110 |
| Crimping Force Range | 50–200 kg/cm² (≈1.8–7.2 kN) |
| Standard Cell Compatibility | CR2016, CR2032 |
| Optional Cell Compatibility | CR2450, CR2012 (with accessory die sets) |
| Handwheel Operating Force | <6 kg |
| Die Material | Imported Japanese stainless steel & specialty tool steel |
| Frame Material | Alloy aluminum & high-strength chrome steel with eco-friendly electroplating and powder coating |
| Dimensions (L×W×H) | 228 × 176 × 310 mm |
| Net Weight | 24.8 kg |
| Factory-Preset Crimping Pressure | ~100 kg/cm² |
| Built-in Pressure Gauge | Analog, calibrated for real-time monitoring |
| Safety Features | Integrated pressure relief valve, adjustable upper pressure limit |
| Warranty | 12 months standard, lifetime technical support |
| Brand | AIWEI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HT-PEMST |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | 0–600 A |
| Power Rating | 2.5 kW (Electronic Load Module) |
| Voltage Range | 0–120 V |
| Gas Flow Control | Anode (H₂/N₂, up to 20 SLPM) |
| Temperature Control | Liquid-Cooled Thermal Loop with 30 L Reservoir |
| Backpressure Control | 0–3.5 bar |
| Preheater | SUS Tubing (Anode: 1/4″, Cathode: 3/8″) |
| Humidification | Integrated Condensate Trap with Auto-Drain, Radiant Heating & Cooling Fan |
| Software Platform | LabVIEW-Based Control Suite with Real-Time DAQ, Protocol Automation, Load Profiling, and Optional EIS Module (10 mHz–10 kHz), HFR/IR Drop Analysis, and Cell-Voltage Monitoring (±5 V per cell, selectable channels) |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | CompactStat.h |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 pA to ±10 mA (12 ranges: 1 pA, 10 pA, 100 pA, 1 nA, 10 nA, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | −10 V to +10 V |
| EIS Frequency Range | 10 µHz to 3 MHz |
| Current Resolution | down to 0.6 aA (at selected range) |
| Potential Resolution | down to 0.07 nV (at selected range) |
| Applied Signal Resolution | 0.00013% |
| Measurement Resolution (current) | 0.00006% of selected range |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | CompactStat.h10800 |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | Single-Channel |
| Current Range | 1 pA, 10 pA, 100 pA, 10 nA, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA, 100 mA, 1 A (13 ranges) |
| Current Accuracy | 0.00006% of selected range, minimum 0.6 aA |
| Potential Accuracy | 0.003% of selected range, minimum 16 nV |
| Potentiostatic Range | −10 V to +10 V |
| EIS Frequency Range | 10 µHz to 3 MHz |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | CompactStat.h20250 |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 pA to ±250 mA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.003% of range (minimum 16 nV) |
| Potentiostatic Range | −20 V to +20 V |
| Impedance Frequency Range | 10 µHz to 3 MHz |
| Potential Resolution | 0.00001% of selected range (min. 0.15 nV) |
| Current Resolution | 0.00006% of selected range (min. 0.6 aA) |
| Applied Current Resolution | 0.00013% |
| Applied Potential Resolution | 16 nV |
| Key | Brand: Ivium |
|---|---|
| Origin | Netherlands |
| Model | HE80 |
| Channel Count | Single-Channel |
| Current Range | 0–80 A |
| Current Accuracy | ±0.3 mA |
| Potential Accuracy | ±14 nV |
| Potentiostatic Range | +0.5 V to +20 V |
| EIS Frequency Range | 10 µHz–10 kHz |
| Maximum Data Acquisition Rate | 300,000 pts/s |
| Minimum Time Interval | 3.33 µs (0.125 µs resolution) |
| Real-Time Sampling Rate | Up to 500 pts/s |
| Dimensions | 44 × 37 × 8.8 cm |
| Weight | 15 kg |
| Electrode Configuration | 4-Electrode Connection |
| Integrated FRA/EIS | Yes |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | pocketSTAT |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | Single-Channel |
| Current Range | 1 nA, 10 nA, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA |
| Current Accuracy | 0.015% of full scale per range (minimum resolution: 0.15 pA) |
| Potential Accuracy | 0.2% of full scale |
| Potentiostatic Range | −4 V to +4 V |
| AC Impedance Frequency Range | 10 µHz to 100 kHz |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Vertex |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±100 nA to ±10 A (configurable up to 10 A) |
| Current Accuracy | 0.015% of full scale per range, minimum resolution 15 pA |
| Potential Accuracy | 0.3% of full scale |
| Potentiostatic Range | −10 V to +10 V (extended options: ±20 V) |
| EIS Frequency Range | 10 µHz to 1 MHz (optional) |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Vertex.One.EIS |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±100 mA / ±350 mA |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 250 kHz / 1 MHz |
| Data Acquisition Rate | 100 kHz |
| Current Resolution | Down to 10 fA |
| Current Range Span | 100 pA – 1 A |
| Floating Ground Capability | Yes |
| Dual-Potentiostat Configuration | Supported (two units) |
| Multi-Channel Expansion | Supported (multiple units) |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Ivium-n-Stat |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Up to 256 (via modular stacking) |
| Current Range | Standard: ±10 nA to ±10 A (10 decades) |
| Extended | ±10 pA to ±10 A (13 decades) |
| Current Resolution | Down to 1 fA (in 10 pA range) |
| Current Accuracy | ±0.015% of full scale per range |
| Potential Accuracy | ±0.2% or ±2 mV |
| Potentiostatic Range | −10 V to +10 V (extendable to ±20 V, ±40 V, ±100 V with auxiliary modules) |
| EIS Frequency Range | 10 µHz – 250 kHz (extendable to 1 MHz) |
| Data Acquisition Rate | Up to 100 kHz |
| Integrated Impedance Analyzer per Channel | Yes |
| Analog I/O Interfaces | Multiple isolated analog inputs/outputs for external device synchronization |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | iviumstat.h |
| Channel Count | Single-Channel |
| Current Range | ±5 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Current Resolution | 0.6 aA (at 1 pA range) |
| Potential Resolution | 0.15 nV |
| Sampling Rate (Standard) | 100 kHz (10 µs interval) |
| EIS High-Frequency Capability | Up to 8 MHz for solid-state impedance characterization |
| Input Impedance (HiZ module) | >10¹⁵ Ω |
| Bias Current (HiZ) | 3 fA |
| Wireless Connectivity | Integrated Wi-Fi module with SD card data logging |
| Cloud Integration | Ivium Cloud remote access and instrument control via web browser |
| Temperature Monitoring | K-type thermocouple support (TCM-K module) |
| Photoelectrochemical Options | ModuLight LED source (365–940 nm), iviSun solar simulator (1075 W/m², AM1.5G compliant) |
| Expandability | BiStat (dual potentiostat), MultiWE32 (32-electrode multiplexer), QCM/E-QCM, SPR/E-SPR, RDE/RRDE control |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Electrochemical Workstation |
| Model | LABMAN 64-Channel Potentiostat System |
| Channel Count | 64 independent electrochemical channels |
| Current Range | ±1 A per channel |
| Current Accuracy | ±1% of full scale |
| Potential Accuracy | ±1 mV (typical, referenced to internal calibration standard) |
| Potentiostatic Range | ±10 V vs. reference electrode |
| AC Impedance Frequency Range | 1 Hz – 1 MHz (per channel, with optional frequency extension modules) |
| Compliance | CE-marked, RoHS-compliant, designed for integration into GLP/GMP-regulated laboratory automation platforms |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 910 |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | ±2 nA to ±200 µA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±2.048 V |
| Impedance Frequency Range | Not supported (DC-only operation) |
| Potential Resolution | 1 mV |
| Current Resolution | 1 pA (at 2 nA range) |
| Dimensions | 80 × 54 × 23 mm |
| Weight | 94 g |
| Power Supply | 5 V DC / ≤45 mA via USB |
| Interface | Mini-USB + 8-pin Mini-DIN (5 digital I/O, 3 analog inputs @ 10-bit ADC, 1 analog output 0–5 V) |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Type | Single-Channel Electrochemical Workstation |
| Current Range | 1 nA to 100 mA |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| EIS Measurement Accuracy | >99.7% |
| Software | NOVA 2.x |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab |
| Type | Research-Grade Potentiostat/Galvanostat |
| Model | PGSTAT204 |
| Channel Configuration | Multi-Channel Workstation |
| Current Range | 10 nA – 100 mA (8 decades) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±10 V |
| Maximum Output Current | ±400 mA |
| Compliance Voltage | ±20 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Potential Resolution | 3 µV |
| Current Resolution (10 nA range) | 30 fA |
| Input Bias Current (@25°C) | <1 pA |
| Potentiostat Bandwidth | 1 MHz |
| Analog Integrator | Built-in, with integration times of 0.01 s, 0.1 s, 1 s, and 10 s |
| Electrode Configurations | 2-, 3-, or 4-electrode |
| Analog I/O | Bidirectional analog input/output for external signal synchronization |
| Expansion Slot | 1 × modular expansion slot (supports FRA32M, BA, pX1000, MUX, EQCM modules) |
| Interface | USB 2.0 |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Type | Modular Bipotentiostat/Galvanostat |
| Channels | Dual-channel (expandable to multi-channel via MUX module) |
| Current Range | 10 nA – 1 A (9 auto-ranging decades) |
| Current Accuracy | ±0.2% of reading and ±0.2% of range |
| Potential Accuracy | ±2 mV + 0.2% of set value |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±2 A |
| Maximum Output Voltage | ±30 V |
| CV Scan Rate | up to 250 V/s |
| Input Impedance | >1 TΩ |
| Response Time | <250 ns |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Sampling Rate | up to 50 kHz (standard), 10 MHz with ADC10M module |
| EIS Modes | 6 distinct impedance acquisition protocols including potential-frequency, time-frequency, current-frequency sweeps |
| Software Platform | NOVA 2.x (Windows-based, FDA 21 CFR Part 11 compliant with audit trail and electronic signature support) |