Electrophoresis/Gel Imaging/UV Detection
Filter
Showing 1–30 of 158 results
| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | NuacGel Series |
| Instrument Type | Standard Gel Imaging System |
| Electrophoresis Module | Horizontal Benchtop Unit with Dual-Side Casting Platform |
| Imaging Module | Compact CMOS-Based UV/Visible Gel Documentation System |
| Power Supply | Programmable Constant Voltage/Constant Current Source with Real-Time Monitoring and Multi-Step Method Support |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows |
| Safety Features | Interlocked transparent chamber, UV shielded viewing window, emergency stop button, automatic power cutoff on lid opening |
| Sample Throughput | Up to four 70 mm × 70 mm or two 70 mm × 70 mm + two 70 mm × 100 mm gels simultaneously |
| Imaging Sensor | High-sensitivity monochrome CMOS sensor with adjustable exposure and auto-focus optics |
| Software | Image Lab Touch™ embedded interface with automated capture, background subtraction, band intensity quantification, molecular weight estimation, and export-ready TIFF/PNG/JPEG output |
| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | ProLux Series |
| Instrument Type | WB Imaging & Processing System |
| Automation Level | Fully Automated |
| Transfer Method | Wet Transfer |
| Maximum Gel Capacity (Electrophoresis) | 4 mini-gels |
| Maximum Transfer Capacity | 2 gels (100 mm × 75 mm) |
| Temperature Control Range | 2–40 °C (Peltier-based) |
| Incubation Channels | 12 independent channels |
| Membrane Throughput | up to 24 membranes per run |
| Wash Buffer Volume Control | Adjustable per cycle |
| Imaging Sensor | High-sensitivity cooled CMOS |
| Light Sources | LED-based transillumination and epi-illumination |
| Fluorescence Channels | RGB + Far-Red/NIR (upgradable) |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible workflow logging |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2100 |
| Instrument Type | Protein Electrophoresis System |
| Primary Device | Microfluidic Capillary Electrophoresis Platform |
| Sample Throughput | Up to 12 Samples per Run |
| Sample Volume | 1–5 µL (varies by assay type) |
| RNA Quality Metric | RNA Integrity Number (RIN) |
| Power Consumption | 60 VA |
| Safety Compliance | IEC 61010-1, Installation Category II, Pollution Degree 2 |
| Laser Classification | Class 1 |
| Operating Temperature | 15–27 °C |
| Dimensions (W × D × H) | 162 mm × 412 mm × 290 mm |
| Weight | 10 kg |
| Input Voltage | 100–240 VAC |
| Input Frequency | 50–60 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 4150 TapeStation |
| Instrument Type | Nucleic Acid Quality Control Electrophoresis System |
| Sample Capacity | Up to 16 samples per run |
| Input Voltage | 100–240 VAC, 50–60 Hz |
| Dimensions (W × D × H) | 254 mm × 510 mm × 417 mm |
| Power Consumption | 50 VA |
| Weight | 17.8 kg |
| Sample Volume Requirement | 1–2 µL per assay |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 4200 TapeStation |
| Instrument Type | Nucleic Acid Quality Control Electrophoresis System |
| Sample Capacity | 1–96 samples per run |
| Voltage/Current | 100–240 VAC, 50–60 Hz |
| Dimensions (W × D × H) | 435 mm × 510 mm × 445 mm |
| Power Consumption | 50 VA |
| Weight | 25.5 kg |
| Sample Volume Requirement | 1–2 µL per assay |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Fragment Analyzer 5400 |
| Instrument Type | Nucleic Acid Electrophoresis System |
| Sample Throughput | >2,400 samples per 24 hours |
| Voltage/Current | 100–240 VAC, 47–63 Hz |
| Dimensions (W × D × H) | 36 cm × 51 cm × 61 cm |
| Power Consumption | 150 VA |
| Operating Temperature | 19–25 °C |
| Relative Humidity | 20–80 % RH |
| Weight | 38.5 kg |
| Sample Format | 96-well plate per run |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | ProteoAnalyzer 12-Capillary Array |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | ProteoAnalyzer Components & Accessories |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ProteoAnalyzer System |
| Instrument Type | Capillary Electrophoresis (CE-SDS) Analyzer for Proteins |
| Sample Capacity | 12 samples per run |
| Voltage/Current Input | 100–240 VAC, 47–63 Hz |
| Dimensions (W × D × H) | 35 cm × 51 cm × 61 cm |
| Weight | 38.5 kg |
| Power Consumption | 150 VA |
| Operating Relative Humidity | 20–80 % RH |
| Temperature Range | Ambient (15–30 °C) |
| Detection Sensitivity | ≥1 ng/µL BSA in PBS |
| Linear Dynamic Range | 2–2000 ng/µL BSA in PBS |
| Separation Range | 10–240 kDa |
| Capillary Format | Parallel capillary array with on-capillary fluorescence detection |
| Separation Chemistry | Capillary Gel Electrophoresis (CGE) with SDS denaturation and covalent fluorescent labeling |
| Brand | Cytiva |
|---|---|
| Origin | United Kingdom |
| Model | Amersham DIGE Unit LF24 |
| Gel Dimensions | 255 × 186 × 1 mm |
| External Dimensions | 277 × 217 × 7 mm |
| Max. Simultaneous Gels (Electrophoresis) | 2 |
| Max. Simultaneous Gels (Transfer) | 2 |
| Max. Voltage | 800 V |
| Max. Current | 400 mA |
| Max. Power | 100 W |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Category | Imported |
| Models | Compact XS, Compact S, Compact M, Compact L, Compact XL |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported |
| Models | Eco-Mini, Eco-Maxi |
| Pricing | Upon Request |
| Gel Dimensions (Eco-Mini) | 9.4 × 8.0 cm |
| Gel Dimensions (Eco-Maxi) | 19.4 × 18.5 cm |
| Glass Plate Dimensions (Eco-Mini) | 11.0 × 10.0 cm |
| Glass Plate Dimensions (Eco-Maxi) | 21.0 × 20.0 cm |
| Max. Gels per Run | 2 |
| Comb Thickness Options | 0.75 mm, 1.0 mm, 1.5 mm |
| Comb Tooth Counts | 9–30 (Eco-Mini), 12–60 (Eco-Maxi) |
| Sample Capacity | Up to 30 wells (Eco-Mini), up to 60 wells (Eco-Maxi) |
| Well Volume Range | 15–165 µL |
| Buffer Volume (Eco-Mini) | 1580 mL (electrophoresis), 2180 mL (blotting) |
| Buffer Volume (Eco-Maxi) | 5400 mL (electrophoresis), 6100 mL (blotting) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | Eco-Mini and Eco-Maxi |
| Instrument Type | Wet Transfer Electrophoresis System |
| Gel Dimensions | 8 × 7 cm |
| Sample Capacity | 10-well comb (single gel) or 20-well comb (dual gels) |
| Voltage/Current Range | 0–300 V / 0–400 mA |
| External Dimensions | 15 × 12 × 20 cm |
| Glass Plate Thickness | 3 mm |
| Optional | Integrated Cooling Circulation Unit |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Imported Instrument |
| Model | Scandrop |
| Price | Upon Request |
| Optical Principle | Diode Array Spectrophotometry |
| Wavelength Range | 190–720 nm |
| Wavelength Accuracy | ±0.5 nm |
| Photometric Stability | 0.002 A/h |
| Photometric Range | 0.02–300 A (equivalent to 10 mm pathlength) |
| Photometric Accuracy | ±0.02 A (UV), ±0.01 A (VIS) |
| Measurement Time | 1 s per full spectrum |
| Sample Volume (CHIPCUVETTE) | 0.3–4 µL |
| CHIPCUVETTE Pathlengths | 0.1 mm or 1.0 mm |
| Cuvette Mode Sample Volume | ≥1.7 mL |
| Cuvette Pathlength | 10 mm |
| Interfaces | USB, RS-232 |
| Dimensions (W×H×D) | 240 × 170 × 200 mm |
| Weight | 5 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ScanDrop2 |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | Analytik Jena GmbH |
| Model | UVP ChemStudio Touch |
| CCD Resolution | 8.1 MP (3296 × 2472) |
| CCD Cooling | −57 °C |
| Touchscreen | 15.6″ Full-Color Capacitive Display |
| Light Sources | LED, Xenon Broadband Lamp, Dual-NIR Lasers (700/800 nm) |
| Filter Capacity | 21 Position Motorized Filter Wheel |
| Binning Options | 1×1 to 8×8 |
| Max Effective Resolution | 16.2 MP |
| Supported Imaging Modes | UV Transillumination, Fluorescence (RGB & NIR), Chemiluminescence, 2D DIGE, In Vivo Plant & Animal Imaging |
| Image Formats | JPG, BMP, TIFF, GIF, TGA, PNG, AVI |
| UV Transilluminator | Long-Life Cold-Cathode Fluorescent Lamp (20-Year Lifetime) |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Auto 12 |
| Instrument Type | Automated Western Blot Processor |
| Core Component | Multi-channel incubation station with temperature-controlled gel trays |
| Temperature Control Range | 2–40 °C |
| Channel Independence | 12 individually programmable channels |
| Antibody Recovery Efficiency | Up to 95% |
| Compatible Gel Tray Sizes | Standard mini-gel (7 × 8 cm), midi-gel (10 × 10 cm), and custom-fit formats |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | CycleBlot |
| Instrument Type | Protein Transfer System |
| Automation Level | Semi-Automatic |
| Transfer Method | Wet Transfer |
| Transfer Dimensions | 110 × 90 mm |
| Gel Capacity | 1–4 mini gels |
| Molecular Weight Range | 5–200 kDa |
| Transfer Time | 20 min |
| Cooling System | Peltier-based recirculating cooling |
| Reagent Compatibility | Standard transfer buffers (e.g., Tris-Glycine, CAPS, Bicine) |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | ONEblot |
| Pricing | Upon Request |
| Instrument Type | Chemiluminescence Gel Imaging System |
| Dynamic Range | 6 OD |
| Sensor Area | 170 cm² |
| Detection Sensitivity | fg-level |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Chemiluminescence Gel Imaging System |
| Dynamic Range | 6 OD |
| Model | ONEblot Pro |
| Compliance | CE-marked for laboratory use |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Model | Power HC 3000 |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 5–250 V |
| Current Range | 1–3000 mA |
| Dimensions (L×W×H) | 308 × 242 × 100 mm |
| Safety Features | Overvoltage, Arc, Open-Circuit & Load-Transient Detection |
| Display | LCD showing real-time Voltage, Current, Power, and Timer |
| Brand | Aperbio |
|---|---|
| Model | PowerBasic 300 |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Voltage Range | 5–300 V |
| Current Range | 1–400 mA |
| Dimensions (L×W×H) | 308 × 242 × 100 mm |
| Display | LCD showing real-time voltage, current, power, and timer |
| Programmable Methods | 10 stored protocols, up to 10 steps per method |
| Parallel Outputs | 4 independent output channels |
| Safety Features | Overvoltage, arc detection, open-circuit alarm, short-circuit/overload protection, leakage current protection, auto-recovery after power interruption, pause/resume function |
| Gel Compatibility | Optimized for SDS-PAGE, native PAGE, agarose gel electrophoresis, and isoelectric focusing (IEF) applications |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | PowerBasic 600 |
| Instrument Category | Electrophoresis Power Supply |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Voltage Range | 5–600 V |
| Current Range | 1–1200 mA |
| Dimensions (L×W×H) | 308 × 242 × 100 mm |
| Safety Features | Overvoltage, Arc, Open-Circuit & Load-Transient Detection |
| Special Functions | Automatic Transition from Stacking to Separating Gel Mode |
| Brand | Aplegen |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 5.0 Megapixels |
| Bit Depth | 12-bit |
| Lens | Fixed F1.4 Aperture Lens |
| Excitation Source | 470 nm Blue LED Array |
| Safety Interlock | UV Door-Activated Power Cutoff |
| Integrated Control | Embedded Touchscreen Tablet |
| Compatible Stains | SYBR® Green, MaestroSafe™, GelGreen™, Ethidium Bromide (EtBr), Coomassie Brilliant Blue, Silver Nitrate |
| Brand | Aplegen |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Omega LumC |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 8.4 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| Lens Aperture | f/0.95 |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Co., Ltd. |
| Model | C3-6653-01 |
| Instrument Type | Power Supply-Integrated Horizontal Electrophoresis Apparatus |
| Operating Voltage | 35 / 50 / 100 V DC (selectable, fixed-step) |
| Safety Interlocks | Lid-open detection, no-buffer sensing, overcurrent cutoff |
| Dimensions (W × D × H) | 190 × 130 × 55 mm |
| Power Input | 100 V AC (Japan standard) |
| Compliance | JIS T 0601-1, IEC 61010-1 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) |
| Brand | Azure Biosystems |
|---|---|
| Origin | USA |
| Model | Azure 200 |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 5.4 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| CCD Sensor Size | 2/3-inch |
| Detection Sensitivity | fg-level |
| Signal-to-Noise Ratio | High |
| Lens | Motorized Autofocus |
| Integrated Display | 13.3-inch HD Touchscreen PC |
| Excitation Sources | Dual-wavelength UV (e.g., 254 nm & 302 nm), Blue Light (470 nm) |
| Imaging Modes | DNA, Protein, Colorimetric, Fluorescent (with compatible dyes) |
| Brand | Azure Biosystems |
|---|---|
| Origin | USA |
| Model | Azure 300 |
| Instrument Type | Chemiluminescent Gel Imaging System |
| CCD Resolution | 9.1 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| CCD Sensor Size | 2/3-inch |
| Detection Sensitivity | sub-femtogram (fg) level |
| Signal-to-Noise Ratio | High |
| Lens | Fixed-focus, large-aperture optics |
| Brand | Azure Biosystems |
|---|---|
| Origin | USA |
| Model | Azure 400 |
| Instrument Type | Multicolor Fluorescence Gel Imaging System |
| CCD Resolution | 9.1 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| CCD Sensor Size | 2/3-inch |
| Detection Sensitivity | fg-level |
| Signal-to-Noise Ratio | High |
| Lens | Fixed-focus, Large-aperture Optical Lens |
| Brand | Azure Biosystems |
|---|---|
| Origin | USA |
| Model | Azure 500 |
| Instrument Type | Multispectral Fluorescence Gel Imaging System |
| CCD Resolution | 9.1 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| CCD Sensor Size | 2/3" |
| Detection Sensitivity | fg-level |
| Signal-to-Noise Ratio | High |
| Lens System | Motorized Autofocus |
| Integrated Display | 13.3" HD Touchscreen PC |