| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | ProLux Series |
| Instrument Type | WB Imaging & Processing System |
| Automation Level | Fully Automated |
| Transfer Method | Wet Transfer |
| Maximum Gel Capacity (Electrophoresis) | 4 mini-gels |
| Maximum Transfer Capacity | 2 gels (100 mm × 75 mm) |
| Temperature Control Range | 2–40 °C (Peltier-based) |
| Incubation Channels | 12 independent channels |
| Membrane Throughput | up to 24 membranes per run |
| Wash Buffer Volume Control | Adjustable per cycle |
| Imaging Sensor | High-sensitivity cooled CMOS |
| Light Sources | LED-based transillumination and epi-illumination |
| Fluorescence Channels | RGB + Far-Red/NIR (upgradable) |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible workflow logging |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | CycleBlot |
| Instrument Type | Protein Transfer System |
| Automation Level | Semi-Automatic |
| Transfer Method | Wet Transfer |
| Transfer Dimensions | 110 × 90 mm |
| Gel Capacity | 1–4 mini gels |
| Molecular Weight Range | 5–200 kDa |
| Transfer Time | 20 min |
| Cooling System | Peltier-based recirculating cooling |
| Reagent Compatibility | Standard transfer buffers (e.g., Tris-Glycine, CAPS, Bicine) |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | Trans-Blot Turbo |
| Automation Level | Fully Automated Western Blot Transfer System |
| Throughput | 4 mini gels or 2 midi gels per run |
| Dual Cassette Design | Yes |
| Transfer Time | ≤3 min (2 TGX Mini Gels), ≤7 min (4 standard mini gels or 2 midi gels) |
| Power Supply | Integrated constant voltage/current/power regulator |
| User Interface | Backlit LCD touchscreen with programmable protocol storage (25 protocols) |
| Electrode Architecture | 6-spring-loaded parallel plate electrodes |
| Pre-formulated Kits | Compatible with Turbo Transfer Packs (buffer-free, membrane-ready) |
| Compatibility | Works with standard PVDF/nitrocellulose membranes, conventional electrophoresis buffers (e.g., Tris-Glycine, CAPS), and legacy gel formats |
| Brand | BioLight |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PAG-100Auto |
| Automation Level | Fully Automated Gel Casting System |
| Gel Throughput | 5 or 10 gels per batch |
| Gel Polymerization Time | ≤10 min |
| Ready-for-Electrophoresis Time | ≤15 min from reagent addition |
| Protein Separation Range | 10–200 kDa |
| Storage Stability | Up to 14 days at 4 °C |
| Acrylamide System | Low-toxicity acrylamide formulation with optimized APS-initiated polymerization |
| Precision Delivery | Dual magnetic stirrers + dual automated dispensing channels (separating & stacking gels) |
| Compatibility | Standard vertical electrophoresis tanks (e.g., Mini-PROTEAN®, SE600, Hoefer Mighty Small) |
| Brand | BioLight |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | WB-600Auto |
| Instrument Type | Automated Western Blot Processing System |
| Automation Level | Fully Automated |
| Liquid Pumps | 30 independent peristaltic pumps |
| Throughput | Up to 6 membranes simultaneously |
| Incubation Chamber Compatibility | Two formats — 88 × 88 mm and (58 × 88 mm / 28.5 × 88 mm) |
| Reagent Storage | Integrated refrigerated reagent compartment (4–10 °C) |
| Software Control | Touchscreen interface with programmable step parameters (volume, time, agitation speed, cycle count) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | PACIFICIMAGE |
|---|---|
| Origin | Taiwan |
| Model | Chemlux 600RGBW |
| Instrument Type | Semi-Automatic Western Blot Imaging System |
| Camera | 6 MP Cooled CCD (−55 °C below ambient) |
| Resolution | 2736 × 2160 pixels |
| Pixel Size | 4.54 µm × 4.54 µm |
| Exposure Range | 10 ms – 90 min |
| Lens | f/0.95, 25 mm fixed focal length |
| Field of View | Up to 26 cm × 20 cm |
| Filter Wheel | 6-position motorized |
| Light Sources | UV (306 nm transillumination), Epi-White, Epi-Blue (470 nm), Epi-Green (530 nm), Epi-Red (630 nm), White backlight |
| Platform | 3-level manual sample stage (12×9 cm, 19×14 cm, 26×20 cm) |
| Dynamic Range | 16-bit |
| Binning Modes | Up to 6×6 |
| Auto-Focus | Yes |
| Cooling Indicator | Integrated LED status |
| Data Backup | Automatic local + network backup |
| Remote Access | LAN/WLAN via embedded Linux OS |
| Display | 10.4″ capacitive multi-touch LCD |
| Connectivity | USB 2.0 ×3, 10/100 Ethernet ×1 |
| Storage | 8 GB internal |
| Certifications | CE, FCC |
| Dimensions (L×W×H) | 452 × 423 × 659 mm |
| Weight | 52 kg |
| Power | AC 100–240 V, 50/60 Hz, 200 W |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA (Manufactured Globally per ISO 13485) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | iBlot® 2 |
| Automation Level | Semi-Automated Western Blot Transfer System |
| Power Supply | Integrated 24 V DC internal power module |
| Dimensions (W × D × H) | 29.5 × 24.1 × 19.7 cm |
| Weight | 6.8 kg |
| Pre-Programmed Protocols | 12 built-in (including PVDF/Nitrocellulose, 1D/2D gels, low-MW/high-MW proteins) |
| Custom Protocol Storage | Up to 20 user-defined methods |
| Touchscreen Interface | 4.3-inch capacitive LCD with GLP-compliant audit trail logging |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | SNAP i.d. 2.0 |
| Automation Level | Semi-Automatic Western Blotting System |
| Operating Principle | Vacuum-Driven Fluidic Processing |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | SNAP i.d. 2.0 |
| Automation Level | Semi-Automatic Western Blot Processing System |
| Voltage Options | 115 V/60 Hz or 220 V/50 Hz |
| Maximum Membrane Capacity | 6 membranes (simultaneous) |
| Processing Time for Blocking, Washing & Antibody Incubation | ≤30 minutes |
| Compatible Membrane Formats | Single-, Dual-, and Triple-slot blotting cassettes |
| Brand | PacificImage |
|---|---|
| Origin | Taiwan |
| Model | Glite 600UV/BW |
| Instrument Type | Semi-Automatic Western Blotting & Gel Imaging System |
| Camera | Starlight-grade CMOS, 6 MP (3096 × 2080) |
| Bit Depth | 8/16-bit output |
| Exposure Time | 5 ms – 10 s |
| Excitation Sources | UV (302 nm), Blue LED (470 nm), White LED (optional) |
| Imaging Area | 13 × 18 cm |
| Filter Holder | Manual dual-slot |
| Emission Filter | 620 nm bandpass amber filter |
| Operating System | Windows 7/8/10 |
| Image Formats | TIFF, JPEG, BMP |
| Interface | USB 3.0 |
| Dimensions (W×H×D) | 300 × 260 × 257 mm |
| Weight | 10 kg |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | 11327-41BL (0.22 µm), 11306-41BL (0.45 µm) |
| Format | Roll (30 cm × 3 m) |
| Protein Binding Capacity | >200 µg/cm² (IgG) |
| Pore Size Options | 0.22 µm, 0.45 µm |
| Pretreatment | Water-wet only — no methanol activation required |
| Material | 100% pure nitrocellulose |
| Compliance | Suitable for ISO/IEC 17025-compliant laboratories |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | T48 |
| Instrument Type | Fully Automated Western Blotting System |
| Automation Level | Fully Automated |
| Sample Capacity | Up to 48 samples per run |
| Incubation Temperature Control | Peltier-based active heating and cooling (range: 4–65 °C) |
| Wash Throughput | Simultaneous processing of up to 3 membrane strips |
| Reagent Delivery | Precision peristaltic pumps with auto-calibration |
| Waste Management | Dual-channel segregated waste collection (hazardous & biohazard) |
| Software | Blotware™ v5.x with audit trail, user access levels, and protocol scheduling |
| Compliance | Designed for GLP/GMP environments |
| Brand | WIX |
|---|---|
| Origin | Shanghai, China |
| Model | WIX-autoPP Automated Western Blot Processing System |
| Throughput | Up to 24 membranes per run |
| Incubation Modules | 12 independently controlled modules |
| Temperature Control Range | 4–40 °C |
| Antibody Recovery Rate | ≥95% (up to 10 reuses) |
| Module Dimensions (optional) | 3×8 cm, 6×8 cm, or 9×8 cm |
| Membrane Wetting Maintenance | On-board wash buffer retention post-incubation |
| Fluidic Cross-Contamination Prevention | Automated in-line tubing rinse cycles |
| Compatibility | Open-platform design supports third-party primary/secondary antibodies and wash buffers |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Protein Transfer System |
| Automation Level | Fully Automated |
| Transfer Method | Semi-Dry Electrophoretic Transfer |
| Max Output Voltage | 0–25 V (1 V increments) |
| Max Output Current | 0–2.5 A (0.1 A increments) |
| Display | 7-inch capacitive touchscreen with real-time parameter monitoring |
| Programmable Methods | 25 user-defined protocols |
| Transfer Plate Dimensions | 18.0 × 14.5 cm |
| Throughput | 1–4 mini gels or 1–2 midi gels per run |
| Compatible Buffers | Optimized semi-dry transfer buffer concentrate (supplied) |
| Recommended Applications | Proteins ≤180 kDa (transfer time: 7–15 min at 25 V constant voltage) |