| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Model | DYCZ-TRANS2 |
| Instrument Type | Semi-Dry Electrophoretic Transfer System |
| Gel Compatibility | 180 × 190 mm 2D gels (dual-gel capacity) |
| Sample Throughput | Up to 2 mini-gels simultaneously |
| Voltage Range | 20–200 V DC |
| Electrode Spacing | 4 cm |
| Transfer Plate Dimensions | 10 × 7.5 cm |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DYY-3C |
| Instrument Type | Electrophoresis Power Supply |
| Gel Compatibility | Standard protein and nucleic acid gels |
| Output Range | 6–400 V (1 V resolution), 4–400 mA (1 mA resolution), Max. 120 W |
| Dimensions (W×D×H) | 235 × 295 × 95 mm |
| Weight | 2.5 kg |
| Output Channels | 4 parallel independent outputs |
| Protection Features | Over-voltage, over-current, over-load, and load-mismatch detection with audible/visual alarm |
| Control System | Microprocessor-based digital control with real-time parameter adjustment |
| Display | LCD panel simultaneously showing voltage, current, and countdown timer |
| Power Architecture | High-efficiency switching-mode power supply |
| Memory Function | Stores last-used settings for rapid startup |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Model | DYY-6D |
| Output Channels | 4 independent parallel outputs |
| Voltage Range | 6–600 V (1 V resolution) |
| Current Range | 4–600 mA (1 mA resolution) |
| Power Range | 1–300 W (1 W resolution) |
| Display | Large LCD showing real-time voltage, current, power, and timer |
| Memory Capacity | 10 programmable 3-step protocols |
| Operation Modes | Single-step, multi-step, and auto-recovery after power interruption |
| Safety Features | Over-voltage, over-current, over-power, and short-circuit protection with audible/visual alarm |
| Standby Current Maintenance | Yes |
| Dimensions (W×D×H) | 246 × 360 × 80 mm |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Model | DYY-7C |
| Output Range | 2–300 V (1 V resolution), 5–2000 mA (2 mA resolution), Max Power: 300 W |
| Parallel Outputs | 4 independent channels |
| Protection Features | Over-voltage, over-current, over-load, and load-mismatch detection |
| Display | LCD with real-time simultaneous readout of voltage, current, and timer |
| Control | Microprocessor-based digital control with memory recall |
| Power Architecture | High-efficiency switching-mode power supply |
| Dimensions (W × D × H) | 315 × 290 × 128 mm |
| Weight | 5 kg |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Model | DYCP-38C |
| Electrophoresis Type | Horizontal acetate membrane protein electrophoresis system |
| Gel Dimensions | 70 mm or 90 mm (L) × 250 mm (W), dual-lane format |
| Sample Capacity | Up to 2 × 12 samples per gel (based on 70 mm gel length) |
| Operating Voltage Range | 10–150 V DC |
| External Dimensions (L×W×H) | 370 × 270 × 110 mm |
| Buffer Capacity | 1000 mL |
| Weight | 2 kg |
| Electrode Material | Triple platinum wire electrodes |
| Adjustable leveling feet | 4 pcs |
| Movable bridging rods | 4 pcs |
| Transparent ridge-shaped lid | included |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | WD-9413A |
| Imaging Mode | Visible-light and UV Transillumination/Reflectance |
| CCD Resolution | 3072 × 2304 pixels |
| Bit Depth | 8-bit |
| Detection Sensitivity | >1 pg double-stranded DNA stained with ethidium bromide (EB) |
| Signal-to-Noise Ratio | ≥66 dB |
| UV Transillumination Wavelengths | 302 nm (primary), 254 nm & 365 nm (reflective) |
| UV Illumination Area | 252 × 252 mm |
| White Light Transillumination Area | 260 × 175 mm |
| Dimensions (W × D × H) | 430 × 456 × 755 mm |
| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | WD-9413C |
| Imaging Mode | Visible-Light Gel Imaging System |
| CCD Resolution | 1.3 MP (optional upgrade to 5 MP or 6.4 MP) |
| Bit Depth | 8-bit |
| Dynamic Range | 62 dB |
| CCD Sensor Size | 1/4″ |
| Signal-to-Noise Ratio | 62 dB |
| Lens | Professional 6× Motorized Optical Zoom Lens |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | ChemiDoc Go |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 20 MP (physical pixels) |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | Fixed-focus f/0.95 lens |
| Excitation Sources | Transmitted UV (302 nm), Transmitted Blue Light (470 nm, optional), Transmitted White Light (optional), Reflected UV (365 nm), Reflected Green Light (530 nm) |
| Emission Filters | 520/26 nm BP, 590/110 nm BP, 695 nm LP |
| Dual-Channel Fluorescence | StarBright 520 nm & 700 nm channels |
| Regulatory Status | For research use only (RUO), not for clinical diagnostic use |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | ChemiDoc |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 6.1 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 1-inch |
| Detection Sensitivity | fg-level protein |
| Signal-to-Noise Ratio | >56 dB |
| Lens | Fixed-focus |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | ChemiDoc MP |
| Instrument Type | Multicolor Fluorescent Gel Imaging System |
| CCD Resolution | 6.1 Megapixels |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 1-inch |
| Detection Sensitivity | Sub-femtogram (fg) for Proteins |
| Signal-to-Noise Ratio | >56 dB |
| Lens | Fixed-Focus Optical Lens |
| Imaging Modalities | Chemiluminescence, Multiplex Fluorescence (RGB + Dual NIR), UV Transillumination, White Light Reflection |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | ChemiDoc XRS+ |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 4 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 1-inch |
| Detection Sensitivity | pg–fg level for proteins |
| Signal-to-Noise Ratio | >56 dB |
| Lens | Motorized Zoom Lens |
| Imaging Modes | Chemiluminescence, Fluorescence (single/dual-color), Colorimetric, Densitometry |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | GelDoc Go |
| Imaging Sensor | 6.3 MP monochrome CCD |
| Light Sources | Dual-mode transilluminator (UV 302 nm + blue light 470 nm) |
| Safety Features | Integrated blue-light–optimized optics, included amber safety goggles |
| Imaging Modes | UV transillumination, blue-light transillumination, white-light reflection |
| Fluorescence Compatibility | SYBR Safe, SYBR Gold, Ethidium Bromide (EtBr), GelRed, GelGreen, and other nucleic acid dyes |
| Software | Image Lab Touch™ (touchscreen interface, one-touch capture, auto-exposure, ROI analysis, molecular weight estimation, lane/band quantification) |
| Regulatory Compliance | CE, FCC, RoHS compliant |
| Intended Use | Benchtop gel documentation, nucleic acid and protein gel imaging, blue-light–mediated excision, academic and QC laboratory applications |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | GelDoc Go Blue-Light Safe Gel Imaging System |
| CCD Resolution | 6.3 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| Light Sources | Dual-mode transilluminator (UV 302 nm + Blue Light 470 nm) |
| Safety Configuration | Integrated blue-light excitation with amber safety goggles |
| Instrument Type | Benchtop gel documentation system |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | GelDoc Go |
| Instrument Type | Standalone Gel Documentation System |
| CCD Resolution | 6.3 MP |
| Bit Depth | 16-bit |
| Dynamic Range | >3.5 OD |
| CCD Sensor Size | 1-inch |
| Lens | Fixed-focus QuickSight™ Optical Lens |
| Display | 9.7-inch Capacitive Touchscreen |
| Connectivity | Integrated standalone operation (no PC required) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | GelDoc XR+ |
| Instrument Type | Standard Gel Documentation System |
| CCD Resolution | 4.0 Megapixels |
| Bit Depth | 12-bit |
| Dynamic Range | 0–3.6 OD |
| CCD Sensor Size | 2/3-inch |
| Detection Sensitivity | 0.1 ng DNA stained with ethidium bromide (EB) |
| Signal-to-Noise Ratio | >56 dB |
| Lens | Motorized Optical Zoom Lens (8.5–51 mm focal length) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | GS-900 |
| Instrument Type | Standard Gel Imaging System |
| Bit Depth | 16-bit |
| Optical Density Range | 0.0 to 3.4 OD |
| Illumination Source | LED-based scanning (400–750 nm) |
| Imaging Modes | Transmission and Reflectance |
| Scan Area | 29 × 33 cm |
| Effective Resolution | Adjustable, down to 36.3 µm |
| Image Acquisition Platform | Sealed, humidity-tolerant chamber with adjustable transparent lid |
| Software | Image Lab™ v6.x or later (FDA 21 CFR Part 11 compliant configuration available) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | i12 |
| Instrument Type | Transfer Electrophoresis System |
| Main Unit | Electrophoresis Apparatus with Casting/Running Tank |
| Gel Length Range | 7–24 cm |
| Sample Capacity | 12 independent lanes |
| Maximum Voltage | 10,000 V |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | Trans-Blot Turbo |
| Automation Level | Fully Automated Western Blot Transfer System |
| Throughput | 4 mini gels or 2 midi gels per run |
| Dual Cassette Design | Yes |
| Transfer Time | ≤3 min (2 TGX Mini Gels), ≤7 min (4 standard mini gels or 2 midi gels) |
| Power Supply | Integrated constant voltage/current/power regulator |
| User Interface | Backlit LCD touchscreen with programmable protocol storage (25 protocols) |
| Electrode Architecture | 6-spring-loaded parallel plate electrodes |
| Pre-formulated Kits | Compatible with Turbo Transfer Packs (buffer-free, membrane-ready) |
| Compatibility | Works with standard PVDF/nitrocellulose membranes, conventional electrophoresis buffers (e.g., Tris-Glycine, CAPS), and legacy gel formats |
| Brand | Clinkx |
|---|---|
| Origin | Shanghai, China |
| Model | XinPower 610 |
| Instrument Type | Electrophoresis Power Supply |
| Output Channels | 4 pairs (dual independent outputs) |
| Voltage Range | 1–600 V |
| Current Range | 1–1250 mA |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Display | 5-inch IPS TFT LCD, 800 × 480 resolution |
| Timer Range | 0–999 min |
| Dimensions (W×D×H) | 212 × 283 × 140 mm |
| Safety Features | Overvoltage, open-circuit, short-circuit, overload, and leakage current protection |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | ChemiScope 6100 Touch |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 6.0 Megapixels |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | GenoSens S2 |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 6.37 MP (3089 × 2064 pixels) |
| Bit Depth | 16-bit |
| Lens | High-Resolution Fixed-Focal Lens |
| Imaging Area | 16 × 11.5 cm |
| UV Transillumination | 302 nm LED (17 × 13 cm active area) |
| Blue Light Transillumination | 470 nm LED (17 × 13 cm) |
| White Light Reflectance | Integrated LED |
| Filter | Multi-layer 99% UV-blocking emission filter |
| Sample Stage | Motorized adjustable stage with auto-alignment |
| Interface | USB 2.0, Wi-Fi module optional |
| Touchscreen | Embedded 10.1-inch capacitive multi-touch display |
| Dimensions (W×D×H) | 386 × 355 × 321 mm |
| Compliance | CE, RoHS, ISO 13485–compatible design for laboratory use |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham ImageQuant 800 |
| Imaging Type | Chemiluminescence Gel Imager |
| CCD Resolution | 8.3 MP |
| Lens | Fujinon F0.74 |
| LED Channels | RGB, NIR-short, NIR-long, UV, Side-reflected white light, Transmitted white light |
| GxP Compliance Module | Optional FDA 21 CFR Part 11 / EU GMP Annex 11 Ready |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham ImageQuant 500 |
| Imaging Type | Chemiluminescence |
| CCD Resolution | 8.3 MP |
| Dynamic Range | 4.8 decades |
| Lens Aperture | f/0.14 (Fujifilm) |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon IP |
| Dynamic Range | >5 decades |
| Scan Area | 40 × 46 cm |
| Imaging Modes | Phosphor Imaging, Fluorescence (RGB), Near-Infrared (NIR), Optical Density (OD) |
| Detector Type | High-Sensitivity PMT-based Scanning System |
| Lens | Fujifilm Precision Optics |
| Compliance | Supports IQ/OQ Documentation, GLP/GMP-Ready Data Acquisition |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon NIR / NIR+ |
| Instrument Type | Multicolor Fluorescent Gel Imaging System |
| Detection Principle | Confocal Laser Scanning with Dual-NIR Fluorescence Excitation and Emission Filtering |
| Laser Wavelengths | 685 nm, 785 nm |
| Emission Filters | IRshort 720BP20, IRlong 825BP30 |
| Scan Modes | Automatic, Semi-Automatic, Manual |
| Sample Formats | SDS-PAGE gels, agarose gels, nitrocellulose/PVDF membranes, microplates, Petri dishes, glass slides, tissue sections |
| Detector | Enhanced Photomultiplier Tube (PMT) optimized for NIR spectral range |
| Dynamic Range | >4 orders of magnitude (log-linear response) |
| Spatial Resolution | ≤50 µm (pixel size adjustable) |
| Software Platform | ImageQuant TL with GLP-compliant audit trail and 21 CFR Part 11 optional modules |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon RGB |
| Imaging Modes | Multicolor Fluorescence (RGB), Dual-Channel Near-Infrared (NIR), Phosphor Imaging, Optical Density (OD) |
| Pixel Resolution | Down to 10 µm |
| Scan Area | Up to 40 × 46 cm (Typhoon 5/RGB) |
| Dynamic Range | >5 orders of magnitude |
| Detection Sensitivity | As low as 3 pg protein (fluorescently labeled) |
| Laser Configuration | 5-laser platform (Typhoon 5) |
| Detector Type | High-gain Photomultiplier Tubes (PMTs) |
| Upgrade Path | Field-upgradable across models |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Ettan 2D DIGE |
| Instrument Type | Two-Dimensional Fluorescent Differential Gel Electrophoresis System |
| Core Components | Ettan IPGphor 3 Isoelectric Focusing Unit, Amersham DIGE Unit LF24 Vertical SDS-PAGE Electrophoresis System, Typhoon Laser Scanner with Multi-Channel Fluorescence Detection, CyDye DIGE Fluorophores (Cy2/Cy3/Cy5), Melanie 9 Image Analysis Software |
| Sample Capacity | Up to 3 samples co-separated per 2D gel |
| Sensitivity | Quantitative detection of ≤10% protein abundance change with ≥95% statistical confidence |
| Minimum Sample Requirement | As low as 5 µg total protein per sample |
| Compliance | Designed for GLP-compliant proteomics workflows |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Ettan IPGphor 3 |
| Instrument Type | Isoelectric Focusing (IEF) Electrophoresis System |
| Gel Format Compatibility | IPG strips (7 cm, 11 cm, 13 cm, 18 cm, 24 cm) |
| Sample Capacity | Up to 12 IPG strips per run (with standard manifold) or single IPG strip with Ettan IPGphor Manifold |
| Voltage Range | 0–10,000 V (programmable ramping and stepwise control) |
| Current Limit | 0–100 µA–100 mA (auto-adjusting) |
| Temperature Control Range | 15–30 °C (±0.1 °C stability) |
| Dimensions (W×D×H) | 278 × 160 × 471 mm |
| On-device Method Storage | 10 methods (9 steps each) |
| PC Software Control | Ettan IPGphor 3 Control Software (supports up to 4 instruments simultaneously) |
| Data Logging | Real-time voltage, current, and kV·h monitoring with graphical export |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | TE22 |
| Instrument Type | Wet Protein Electrophoretic Transfer System |
| Gel Capacity | Up to 4 × 9 cm × 10 cm gels per run |
| Cooling System | Integrated aluminum heat exchanger with recirculating buffer cooling |
| Temperature Rise | ≤5°C during standard transfer |
| Buffer Volume Requirement | 1 L per full-load run (4 gels) |
| Cassette Design | Open-mesh gel clamp for uniform pressure, gel/membrane alignment, and prevention of gel wrinkling or drying |
| Compliance | Designed for compatibility with standard SDS-PAGE and Western blotting workflows per ISO/IEC 17025-aligned laboratory practices |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Geliant-D503 |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 2592 × 1944 (5.03 MP) |
| Bit Depth | 16-bit (65,536 gray levels) |
| Dynamic Range | 65,536 gray levels |
| CCD Sensor Size | 13.48 mm × 10.11 mm |
| Pixel Size | 5.2 µm × 5.2 µm |
| Detection Sensitivity | ≤ 0.02 ng double-stranded DNA (ethidium bromide staining) |
| Signal-to-Noise Ratio | 69.8 dB |
| Lens | Imported 6× motorized zoom lens, f/1.2, focal length 8–48 mm |
| Transmission UV Source | Standard 302 nm (high-efficiency ballast, η > 80%, rated lamp life ≥ 40,000 on/off cycles) |
| Transmission White Light | Adjustable-intensity LED uniform illuminator |
| Transmission Blue Light | Optional 470 nm |
| Reflected UV | Optional 254 nm / 365 nm |
| Reflected White Light | Dual-side high-brightness cold LED |
| UV Transilluminator Area | 210 mm × 260 mm |
| Visible Light Transilluminator Area | 210 mm × 260 mm |
| Integrated Gel Cutting Hood | Standard |
| Control Architecture | Fully programmable microprocessor-controlled module (lens zoom/focus/aperture, transmission/reflection illumination, cutting light) |
| Auto UV Shut-off | Configurable timer (1–60 min inactivity) |
| Enclosure | Light-tight dark chamber with interlocked UV safety cutoff |
| Software | DELEITE GelCapture & GelAnalyzer Suite (free lifetime installation, updates, remote training, and on-site support per contractual agreement) |