| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | EClassical 3200 |
| Price Range | USD 14,000 – 56,000 (FOB) |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 130 MPa |
| Column Oven Temperature Control Range | 4–85 °C |
| UV-Vis Detector Wavelength Range | 190–800 nm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | P3100 |
| Price Range | USD 2,800–7,000 (FOB) |
| Pump Type | Isocratic Pump |
| Maximum Operating Pressure | 45 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Flow Accuracy | ≤ ±0.2% |
| Flow Precision (RSD) | ≤ 0.06% |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | D1100 |
| Price Range | USD 2,800–7,000 (FOB) |
| Compatible Instrument | HPLC Systems |
| Detector Type | Ultraviolet-Visible (UV-Vis) Detector |
| Wavelength Range | 190–700 nm |
| Detection Mode | Absorbance (UV-Vis) |
| Light Source | Deuterium Lamp |
| Linear Range | 1.8 AU |
| Baseline Noise | ≤ ±1.0 × 10⁻⁵ AU |
| Baseline Drift | ≤ 2.0 × 10⁻⁴ AU/h |
| Power Supply | AC 220 V ±10%, 50 Hz / 100 W |
| Dimensions (L×W×H) | 420 × 260 × 160 mm |
| Weight | 12 kg |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ambient-Temperature GPC System |
| Pump Flow Range | 0.01–100.00 mL/min |
| Pump Pressure Limit | 42 MPa |
| Refractive Index Detector Drift | Not Specified |
| RI Detector Flow Cell Volume | Not Specified |
| UV-Vis Detector Wavelength Range | Not Specified |
| UV-Vis Detector Noise Level | Not Specified |
| Column Oven Temperature Range | Not Specified |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Chromatography Data Workstation |
| Price Range | USD 1,400 – 7,200 (based on configuration) |
| Software Type | Chromatography-Specific Data Acquisition & Management System |
| Regulatory Compliance | GLP/GMP, FDA 21 CFR Part 11, Chinese NMPA Guidelines for Chromatographic Data Integrity |
| Optional Modules | System Suitability Testing (SST), Gel Permeation Chromatography (GPC) Analysis, Photodiode Array (PDA) Data Processing, Multi-System Instrument Control |
| Audit Trail | Full, time-stamped, immutable, user-attributed event logging (login/logout, parameter changes, report generation, method edits, data deletion/reprocessing) |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | LU3100 Quaternary |
| Quotation | Upon Request |
| Flow Range | 0.001–10.000 mL/min (settable in 0.1% increments) |
| Gradient Accuracy | ≤ ±2.0% |
| Mixing Volume | 500 µL |
| Power Supply/Power Consumption | AC 220 V ±10%, 50 Hz / 30 W |
| Dimensions/Weight | 420 × 300 × 115 mm (L×W×H) / 4 kg |
| Vacuum Degassing | Integrated with external DG3110 quaternary degasser |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | P3500 Semi-Preparative |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ≤ ±1.0% |
| Flow Precision (RSD) | ≤ 0.3% |
| Maximum Operating Pressure | 30 MPa |
| Wavelength Range | 190–700 nm |
| Baseline Noise | ≤ ±0.5 × 10⁻⁵ AU |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UV3100 |
| Compatible Instrument | HPLC Systems |
| Detector Type | UV-Vis Absorbance Detector |
| Wavelength Range | 190–700 nm |
| Detection Principle | UV-Vis Absorption Spectrophotometry |
| Light Source | Deuterium Lamp |
| Baseline Noise | ≤ ±0.5 × 10⁻⁵ AU |
| Baseline Drift | ≤ 1.0 × 10⁻⁴ AU/h |
| Linear Dynamic Range | 2.0 AU |
| Flow Cell Options | Analytical Cell (10 mm pathlength, 11 µL volume) |
| Power Supply | AC 220 V ±10%, 50 Hz / 100 W |
| Dimensions (L×W×H) | 420 × 300 × 175 mm |
| Weight | 16 kg |
| Analog Output | Optional DA output interface |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DG230 |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) System Component |
| Application Scope | Universal HPLC Solvent Degassing |
| Number of Channels | 2–5 |
| Max Flow per Channel | 10 mL/min |
| Degassing Membrane Material | Teflon® AF |
| Rated Pressure (Full Flow) | 0.48 MPa |
| Channel Volume | 480 µL |
| Internal Diameter | 1.2 mm |
| Pressure Drop | 3.9 mmHg/(mL/min) |
| Power Supply | DC 15–24 V |
| Dimensions | 190 × 140 × 56 mm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AAk Amino Acid Analysis System |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Amino Acid Quantification |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 45 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0–100 µL |
| Column Oven Temperature Range | 5–80 °C |
| UV Detection Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 20 Hz |
| Brand | Elite |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fast Liquid Chromatograph |
| Model | 3200 HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 90 MPa |
| Column Oven Temperature Range | 4–85 °C |
| UV-Vis Detector Wavelength Range | 190–800 nm |
| Gradient Architecture | Binary (post-column mixing) or Quaternary (proportional valve mixing) |
| Solvent Selection Valve | Standard |
| Online Solvent Filtration | Integrated at pump outlet |
| System Expandability | Modular detector, autosampler, and column oven compatibility |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | P2000+ |
| Flow Rate | 1–2000 mL/min |
| Maximum Pressure | 20 MPa |
| Accuracy | ≤±3% |
| Flow Stability (RSD) | ≤0.5% |
| Pressure Display Error | ±5% or ±0.5 MPa |
| Sealing Integrity | Pressure Drop ≤1.5 MPa over 10 min |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤80% |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | 800 W |
| Dimensions (L×W×H) | 350 × 600 × 230 mm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | EClassical3100 |
| Flow Rate Range | 0.001–10.000 mL/min (settable in 0.001 mL/min increments) |
| Maximum Operating Pressure | 45 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0–100 µL (adjustable in 0.1 µL increments) |
| Column Oven Temperature Range | 5 °C above ambient to 80 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 20 Hz |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min (0.001 mL/min increment) |
| Maximum Pressure | 42 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0–100 µL (0.1 µL increment) |
| Column Oven Temperature Range | 5 °C above ambient to 99 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 20 Hz |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Domestic |
| Model | EClassical3150 |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 1–100 mL/min |
| Flow Accuracy | ±1.0% |
| Flow Precision (RSD) | ≤0.5% |
| Maximum Operating Pressure | 21 MPa |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Elite DAC-150 |
| Application Level | Laboratory & Pilot-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Column Internal Diameter | 150 mm (customizable) |
| Bed Height Range | 0–400 mm |
| Column Tube Material | ASTM A269 TP316L Stainless Steel |
| Maximum Operating Pressure | 20 MPa |
| Plate Count (for C18, 10 µm) | ≥40,000 N/m |
| Asymmetry Factor (As) | 0.9–1.2 |
| Drive Mechanism | Pneumatic-Hydraulic Actuation |
| Compliance | Designed to meet GMP design principles for pharmaceutical process development |
| Brand | Elite |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model Series | Shodex |
| Pricing | Available Upon Request |
| Brand | Elite |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic HPLC System |
| Model | 3200 Gradient HPLC |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 90 MPa |
| Column Oven Temperature Range | 4–85 °C |
| UV-Vis Detector Wavelength Range | 190–800 nm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LIFD230 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Category | Conventional High-Performance Liquid Chromatography (HPLC) Detector |
| Application Scope | General-purpose analytical detection in life sciences, environmental analysis, and pharmaceutical QC/QA |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fast Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 130 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Column Oven Temperature Range | 5–85 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 2–40 Hz |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | P3500 |
| Instrument Type | Isocratic Pump |
| Maximum Operating Pressure | 30 MPa |
| Flow Rate Range | 0.01–50.00 mL/min |
| Flow Accuracy | ≤ ±1.0% |
| Flow Precision (RSD) | ≤ 0.3% |
| Power Supply | AC 220 V ±10%, 50 Hz / 200 W |
| Dimensions (L×W×H) | 420 × 300 × 175 mm |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Conventional HPLC System |
| Gradient Configuration | Quaternary Low-Pressure Mixing |
| Flow Range (Analytical) | 0.001–10 mL/min |
| Flow Range (Semi-Preparative) | 0.01–100 mL/min |
| Flow Accuracy | ±3% (Analytical), ±5% (Semi-Preparative) |
| Mixer Volume | 800 µL |
| Display | 4-digit LED |
| Communication Interface | RS232 or USB |
| Detector | Diode Array Detector (DAD) |
| System Architecture | Fully Computer-Controlled, Integrated Online Degasser |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | P230p |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) Pump |
| Application Scope | General-Purpose Preparative & Analytical LC |
| Flow Rate Range | 0.01–40.00 mL/min |
| Maximum Operating Pressure | 30 MPa (at 0.01–20.00 mL/min) |
| Flow Precision | RSD < ±1.0% |
| Flow Accuracy | ±0.2% (measured at 10.00 mL/min, 8.5 MPa, water, 25 °C) |
| Pressure Display Error | ≤ ±3% |
| Pressure Pulsation | ≤ 1.0% |
| Power Supply | 220 V, 50 Hz |
| Dimensions (W×D×H) | 420 × 280 × 175 mm |
| Brand | Elite |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Model | MS2 Vertical 9100 |
| Price Range | USD 210,000 – 325,000 (FOB China) |
| Mass Range | m/z 5–1500 |
| Sensitivity (ESI+) | ≥ 500,000:1 (S/N, 100 fg injected on-column, reserpine) |
| Maximum System Pressure | 130 MPa |
| Ionization Sources | Dual-source configuration (e.g., ESI & APCI swappable without venting) |