BrandElite
OriginLiaoning, China
Manufacturer TypeManufacturer
Regional CategoryDomestic
ModelD1100
Price RangeUSD 2,800–7,000 (FOB)
Compatible InstrumentHPLC Systems
Detector TypeUltraviolet-Visible (UV-Vis) Detector
Wavelength Range190–700 nm
Detection ModeAbsorbance (UV-Vis)
Light SourceDeuterium Lamp
Linear Range1.8 AU
Baseline Noise≤ ±1.0 × 10⁻⁵ AU
Baseline Drift≤ 2.0 × 10⁻⁴ AU/h
Power SupplyAC 220 V ±10%, 50 Hz / 100 W
Dimensions (L×W×H)420 × 260 × 160 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElite
OriginLiaoning, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelUV3100
Compatible InstrumentHPLC Systems
Detector TypeUV-Vis Absorbance Detector
Wavelength Range190–700 nm
Detection PrincipleUV-Vis Absorption Spectrophotometry
Light SourceDeuterium Lamp
Baseline Noise≤ ±0.5 × 10⁻⁵ AU
Baseline Drift≤ 1.0 × 10⁻⁴ AU/h
Linear Dynamic Range2.0 AU
Flow Cell OptionsAnalytical Cell (10 mm pathlength, 11 µL volume)
Power SupplyAC 220 V ±10%, 50 Hz / 100 W
Dimensions (L×W×H)420 × 300 × 175 mm
Weight16 kg
Analog OutputOptional DA output interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElite
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelChromachem®
Detection PrincipleEvaporative Light Scattering Detection (ELSD)
Compatible SystemsLiquid Chromatography (HPLC/UHPLC)
Light SourceHigh-Intensity Halogen Lamp
Photomultiplier Tube (PMT)High-Sensitivity Detector
Evaporator Temperature Range20–100 °C
Nebulizer Temperature Range20–70 °C
Power SupplyAC 110/240 V, 50/60 Hz, 350 W
Dimensions (L×W×H)480 × 240 × 460 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElite
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelRI-201H
Price RangeUSD 7,000–14,000 (FOB)
Compatible InstrumentHPLC Systems
Detector TypeDifferential Refractive Index Detector
Noise≤2.5×10⁻⁹ RIU (Standard Response Time)
Refractive Index Range1.00–1.75
Detection Range0.25–512×10⁻⁶ RIU
Linearity Range6×10⁻⁴ RIU
Auto-Zero FunctionOptical & Electronic
Drift≤2.0×10⁻⁷ RIU/h (deionized water, 1 mL/min, purge off)
Response Times0.1, 0.25, 0.5, 1.0, 1.5, 2.0, 3.0, 6.0 s
Temperature ControlOff / 30–50 °C (1 °C increments)
Heater Element Max Temp77 °C
Flow Cell Volume8 μL
Max Flow Rate10 mL/min (water mobile phase)
Max Pressure Rating0.05 MPa
Wetted MaterialsSUS316 Stainless Steel, PTFE (Teflon), Fused Silica
Power SupplyAC 100–240 V ±10%, 50/60 Hz, ≤150 VA
Dimensions (L×W×H)400×260×150 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElite
OriginLiaoning, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic Instrument
ModelD3270
Price RangeUSD 14,000–28,000 (FOB)
Compatible SystemsHPLC, UHPLC
Detector TypeEvaporative Light Scattering Detector (ELSD)
Operating Frequencies10 Hz / 20 Hz / 50 Hz / 100 Hz
Detection PrincipleHigh-Sensitivity Photomultiplier Tube (PMT)
Light Source650 nm, 30 mW Stable Laser Diode
Baseline Noise< 0.01 mV (RMS, 1 s bandwidth)
Baseline Drift< 0.05 mV / 30 min
Signal InterfacesRS-232, RS-485, USB 2.0, Ethernet (UDP protocol)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElite
OriginLiaoning, China
Manufacturer TypeManufacturer
Product OriginDomestic
ModelMFD3100
Price RangeUSD 7,000–14,000 (FOB)
Compatible InstrumentHPLC Systems
Detector TypeFluorescence Detector (FD)
Excitation Wavelength Ranges324–350 nm
Detection MethodConfocal Optical Path System
Light SourceTriple High-Stability LED Array with Motorized Auto-Switching Mechanism
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElite
OriginLiaoning, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelD3200
Price RangeUSD 7,000–14,000 (FOB)
Compatible InstrumentHPLC Systems
Detector TypeUltraviolet-Visible (UV-Vis) Detector
Wavelength Range235–254 nm
Detection MethodDual-Beam Optical Path
Light SourcesDeuterium Lamp & Tungsten-Halogen Lamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElite
OriginLiaoning, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelDAD3100
Instrument TypeDiode Array Detector (DAD)
Wavelength Range190–800 nm
Detection MethodDiode Array
Light SourceTungsten-Halogen & Deuterium Lamps
Baseline Noise≤ ±1.0 × 10⁻⁵ AU
Baseline Drift≤ 2.0 × 10⁻⁴ AU/h
Dimensions500 × 300 × 175 mm (L×W×H)
Weight18 kg
Power SupplyAC 220 V ±10%, 50 Hz
Power Consumption80 W