- All
- Favorite
- Popular
- Most rated
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-150 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Internal Chamber Dimensions (W×H×D) | 600 × 620 × 405 mm |
| Internal Volume | 150 L |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Humidity Sensor | E+E Elektronik, Austria |
| Temperature Sensor | Heraeus, Germany |
| Insulation | Monolithic Polyurethane Foam |
| Control System | PID + Fuzzy Logic |
| Display | 7-inch Full-Color TFT Touchscreen |
| Data Logging | 3-year capacity (1-min intervals), exportable via USB, read-only |
| Audit Trail | 16,000+ immutable entries (operations & alarms), USB exportable |
| User Management | 5 configurable roles with hierarchical permissions |
| Communication Interfaces | RS232, RS485, USB-B |
| Compliance Support | GLP/GMP-ready logging, 21 CFR Part 11-compatible audit trail architecture |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-1000 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.2–0.5 °C (at 15–45 °C) |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Internal Dimensions (W×H×D) | 1300 mm × 1180 mm × 660 mm |
| Internal Volume | 1012 L |
| Refrigeration System | Inverter-Driven SECOP (Danfoss) Compressor with EBM Condenser Fan |
| Humidity Sensor | Capacitive E+E Electronics Sensor |
| Insulation | Monolithic Polyurethane Foaming |
| Control System | PID + Fuzzy Logic |
| Display | 7-inch Full-Color TFT Touchscreen |
| Data Logging | ≥10 Years of Immutable Raw Data (U-disk Export Only) |
| Audit Trail | 16,000+ Timestamped Operator & Alarm Events |
| User Management | 5 Configurable Accounts with Role-Based Permissions |
| Communication Interfaces | USB, RS-232, RS-485 |
| Language Support | English / Chinese Switchable |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA 760 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.2–0.8 °C (at 15–45 °C) |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Internal Dimensions (W×H×D) | 1300 × 1180 × 500 mm |
| Internal Volume | 767 L |
| Refrigeration System | Inverter-Driven SECOP (Danfoss) Compressor with EBM Condenser Fan |
| Humidity Sensor | Capacitive E+E Electronics Sensor |
| Temperature Sensor | HERAEUS Platinum RTD |
| Insulation | Monolithic Polyurethane Foam (≥120 mm thickness) |
| Control System | 7-inch Full-Color TFT Touchscreen with PID + Fuzzy Logic Algorithm |
| Data Logging | ≥10 years of uneditable timestamped records (U-disk export only) |
| Audit Trail | 16,000+ immutable operation & alarm entries |
| User Management | 5 configurable roles with granular permission assignment |
| Communication Interfaces | RS232, RS485, USB |
| Compliance Support | GLP/GMP-aligned data integrity architecture (21 CFR Part 11–ready configuration optional) |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | MTN-80 |
| Price | USD 2,500 (FOB Shanghai) |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | STC 250 |
| Instrument Type | Vertical Temperature and Humidity Controlled Chamber |
| Cooling Method | Air-Cooled |
| Temperature Range | –10 °C to 85 °C |
| Humidity Range | 15–98 %RH |
| Temperature Uniformity | ±0.2–0.5 °C |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Fluctuation | ±1.5 %RH |
| Interior Dimensions (W×H×D) | 670 mm × 912 mm × 410 mm |
| Internal Volume | 250 L |
| Refrigerant | R134a |
| Compressor | Secop (Danfoss Group) |
| Humidity Sensor | E+E Elektronik capacitive sensor |
| Control System | PID + fuzzy logic algorithm |
| Display | 7-inch full-color TFT touch screen |
| Data Logging | 10-year continuous storage (non-editable, USB export) |
| Audit Trail | 16,000+ immutable entries (user actions & alarms) |
| Communication Interfaces | RS232, RS485, USB |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating & Humidification Power | 2200 W |
| Operating Ambient | 5–35 °C |
| Cabinet Insulation | Monolithic polyurethane foam (≥40 mm thickness) |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA 460 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 %RH |
| Temperature Uniformity | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Fluctuation | ±1.5 %RH |
| Interior Dimensions (W×H×D) | 770 mm × 1200 mm × 500 mm |
| Interior Volume | 464 L |
| Compressor | Secop (Danfoss Group) |
| Condenser Fan | EBM (Germany) |
| Humidity Sensor | E+E Elektronik |
| Temperature Sensor | Heraeus |
| Insulation | Monolithic Polyurethane Foam |
| Display | 7-inch True-Color TFT Touchscreen |
| Control System | PID + Fuzzy Logic |
| Data Logging | ≥10 years (U盘-exportable, write-protected) |
| Audit Trail | 16,000 entries (U盘-exportable, immutable) |
| User Management | 5 configurable roles |
| Communication Interfaces | USB, RS-232, RS-485 |
| Language Support | English / Chinese |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-460 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Uniformity | ±1.5 % RH |
| Humidity Fluctuation | ±1.5 % RH |
| Internal Dimensions (W×H×D) | 770 × 1200 × 500 mm |
| Compressor | Secop (Danfoss Group) |
| Condenser Fan | EBM-Papst |
| Humidity Sensor | E+E Elektronik capacitive sensor |
| Temperature Sensor | Heraeus platinum RTD |
| Insulation | Monolithic polyurethane foam |
| Power Supply | AC 220 V, 50/60 Hz |
| Data Logging | ≥10 years internal storage, USB export with write-protection |
| Audit Trail Capacity | 16,000 entries |
| User Management | 5 configurable roles with hierarchical permissions |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-250 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 15–98 % RH |
| Temperature Uniformity | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Interior Dimensions (W×H×D) | 670 × 912 × 410 mm |
| Interior Volume | 250 L |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Humidity Sensor | Capacitive, E+E Elektronik, Austria |
| Temperature Sensor | HERAEUS, Germany |
| Insulation | Monolithic Polyurethane Foam |
| Control System | PID + Fuzzy Logic |
| Display | 7-inch Full-Color TFT Touchscreen |
| Data Logging | ≥10 years (non-editable, USB export) |
| Audit Trail | 16,000 entries (user actions & alarms, non-editable, USB export) |
| User Management | 5 configurable roles with granular permissions |
| Communication Interfaces | RS232, RS485, USB |
| Language Support | English / Chinese Switchable |
| Power Supply | AC 220 V, 50/60 Hz |
| Safety Protections | Over-temperature, over-pressure, leakage current, low-water, door-open, sensor fault, auto-restart after power failure |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | MTN-460 |
| Control Method | PID + Fuzzy Logic |
| Display | 4.3-inch Color TFT Touchscreen |
| Temperature Range | –10°C to +65°C |
| Temperature Uniformity (at 25°C) | ±0.2–0.5°C |
| Temperature Stability | ±0.1°C |
| Internal Volume | 464 L |
| Internal Dimensions (W×H×D) | 750 × 1105 × 560 mm |
| External Dimensions (W×H×D) | 933 × 1765 × 960 mm |
| Net Weight | 210 kg |
| Heating Power | 1200 W |
| Compressor | SECOP (Danfoss) |
| Condenser Fan | EBM (Germany) |
| Refrigerant | Eco-friendly R134a or equivalent |
| Temperature Sensor | HERAEUS (Germany) |
| Insulation | Monolithic Polyurethane Foam |
| Door | Double-door structure with tempered glass inner door |
| Port | Ø50 mm silicone-sealed access port on right side |
| Communication Interfaces | USB, RS-232, RS-485 |
| Data Logging | Up to 3 experiment records stored internally |
| Audit Trail | ≥16,000 entries of operator actions and alarms, stored internally and exportable via USB (immutable) |
| User Management | Administrator-configurable up to 5 users with role-based permissions |
| Sterilization | Built-in UV lamp |
| Language Support | Switchable English/Chinese interface |
| Safety Features | Over-temperature alarm, compressor high-pressure protection, power-failure auto-restart, door-open alarm, sensor fault detection, leakage current protection, timer operation, automatic shutdown/recovery |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-150S |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to +85 °C |
| Humidity Range | 10–98 %RH |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Uniformity | ±1.5 %RH |
| Humidity Fluctuation | ±1.5 %RH |
| Internal Dimensions (W×H×D) | 600 × 620 × 405 mm |
| Internal Volume | 150 L per compartment |
| Total Volume | 300 L |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating & Humidification Power | 1500 W × 2 |
| Refrigeration Power | 250 W (R134a) |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Humidity Sensor | E+E Elektronik, Austria |
| Temperature Sensor | Heraeus, Germany |
| Insulation | Monolithic Polyurethane Foam (≥80 mm thickness) |
| Data Logging | ≥10 years of uneditable raw data storage |
| Audit Trail Capacity | 16,000 entries |
| User Management | 5 configurable roles with granular permissions |
| Communication Interfaces | RS232, RS485, USB |
| Display | 7-inch full-color capacitive touchscreen |
| Control Algorithm | PID + Fuzzy Logic hybrid control |
| Brand | ALISN |
|---|---|
| Model | MTN-150 |
| Type | Mold-Specific Environmental Test Chamber |
| Control System | PID + Fuzzy Logic |
| Display | 4.3" Color TFT Touchscreen |
| Temperature Range | −10 °C to 65 °C |
| Temperature Uniformity (15–45 °C) | ±0.2–0.5 °C |
| Temperature Stability | ±0.1 °C |
| Internal Volume | 150 L |
| Inner Dimensions (W×H×D) | 600×620×405 mm |
| External Dimensions (W×H×D) | 780×1200×802 mm |
| Net Weight | ~125 kg |
| Refrigeration | SECOP (Danfoss) Compressor + EBM Condenser Fan |
| Refrigerant | Eco-friendly R134a or equivalent |
| Insulation | Monolithic Polyurethane Foam (≥60 mm thickness) |
| Sensor | HERAEUS Platinum RTD (Class A, Pt100) |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating Power | 1000 W |
| Safety Features | Over-temperature alarm, compressor overpressure protection, door-open alert, leakage current protection, sensor fault detection, auto-restart after power recovery |
| Data Logging | ≥3 years of timestamped temperature/humidity (if equipped)/status data (non-editable, exportable via USB) |
| Audit Trail | ≥16,000 immutable entries (user actions, alarms, system events) |
| User Management | Up to 5 configurable roles with granular permission assignment |
| Communication Ports | RS232, RS485, USB host/device |
| Sterilization | Built-in UV-C lamp (254 nm) |
| Viewing Window | Tempered double-glazed inner door with silicone-sealed access port (Ø50 mm) |
| Language Support | Switchable English/Chinese GUI |
Show next