| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | PTR-TOF MS 6000 |
| Detection Principle | Proton Transfer Reaction (H₃O⁺-based soft ionization) |
| Instrument Type | Online Real-time Analyzer |
| Configuration | Integrated VOCs Monitoring System |
| Mass Resolution (m/Δm) | ≥ 6,000 (FWHM at m/z 100) |
| Mass Range | m/z 10–500 |
| Detection Limit | < 10 pptv (for common VOCs, 1-s integration) |
| Response Time | < 100 ms |
| Vacuum System | Multi-stage differential pumping with turbomolecular pumps |
| Ion Source | Radiofrequency-guided H₃O⁺ primary ion source |
| Analyzer | Orthogonal acceleration reflectron TOF mass analyzer |
| Data Acquisition Rate | Up to 10 spectra per second |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | PTR-TOF MS 8000 |
| Detection Principle | Proton Transfer Reaction (H₃O⁺-based soft ionization) |
| Instrument Type | Online Real-Time Analyzer |
| Configuration | Integrated VOCs Monitoring System |
| Mass Resolution (m/Δm) | ≥ 8,000 (FWHM at m/z 100) |
| Mass Range | m/z 10–500 |
| Detection Limit | < 10 pptv (for common VOCs, 1-s integration) |
| Data Acquisition Rate | Up to 10 Hz full-spectrum acquisition |
| Vacuum System | Multi-stage differential pumping with turbomolecular pumps |
| Ion Source | RF-driven hollow cathode H₃O⁺ generator |
| Mass Analyzer | Orthogonal acceleration reflectron TOF |
| Software Platform | ALIBEN Acquire v3.2 with real-time spectral deconvolution and compound identification engine |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UVP-TOF MS 2000 LITE |
| Detection Principle | Vacuum Ultraviolet Photoionization (VUV-PI) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Analyzer |
| Configuration | Multi-Component VOC & Inorganic Gas Monitor |
| Detection Range | 0–1 ppbv (extendable to % v/v) |
| Mass Resolution (FWHM) | >2000 |
| Accuracy | RSD <3% |
| Response Time | <1 s |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Domestic |
| Model | UVP-TOF MS 2000 PLUS |
| Detection Principle | Vacuum Ultraviolet Photoionization + Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Analyzer |
| Configuration | Multi-Component VOC Monitor |
| Sampling Method | Direct Gas Inlet |
| Detection Range | 100 pptv – 1 ppmv |
| Mass Resolution (FWHM) | >2500 |
| Accuracy (RSD) | <3% |
| Response Time | <0.5 s |
| Brand | Alibillia |
|---|---|
| Origin | Switzerland |
| Model | GGUN-FL24 |
| Instrument Type | Laboratory & Field-Deployable Water Quality Analyzer |
| Detection Parameters | Fluorescence (e.g., sodium fluorescein, rhodamine WT, sodium naphthionate), Turbidity, Temperature, Conductivity |
| Fluorescence Detection Limit (sodium fluorescein) | 2 × 10⁻¹¹ g/mL (typ.) |
| Turbidity Range | 0.02–400 NTU |
| Minimum Sampling Interval | 4 s |
| Optical Modules | 4 |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.034 °C |
| ADC Resolution | 24-bit unipolar |
| Operating Current | 8–28 mA |
| Enclosure Material | Stainless Steel |
| Ingress Protection | IP68 |
| Dimensions | Ø48 mm × 270 mm |
| Weight | 2.2 kg |
| Cable Length Options | ≥30 m (cable weight: ~1 kg per 10 m) |
| Power Supply | TRMC-series data loggers (TRMC-GGUN or TRMC-GGUN-COM) |
| Brand | Alibillia |
|---|---|
| Origin | Switzerland |
| Model | GGUN-FL30 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Optical Modules | 4 |
| Turbidity Range | 0.02–400 NTU |
| Fluorescein Sodium Detection Limit | 2 × 10⁻¹¹ g/mL (typical, uranine) |
| Minimum Sampling Interval | 4 s |
| Communication Interface | RS232 |
| Operating Current | 8–28 mA |
| ADC Resolution | 24-bit unipolar |
| Cable Length Options | 15–50 m (1 kg per 10 m) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.034 °C |
| Dimensions | Ø160 mm × 170 mm (cylindrical) |
| Enclosure Rating & Material | IP68, stainless steel |
| Weight | 7.3 kg |
| Power Supply | TRMC-series data logger |
| Optional Local Data Logger | TRMC-GGUN |
| Remote Data Logger Option | TRMC-GGUN-COM |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–50,000 µg/L (ppb) as C |
| Accuracy | ±4% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.05 mg/L |
| Repeatability | ≤3% RSD |
| Conductivity Range Limit | <10.0 µS/cm |
| Sample Temperature Range | 1–90 °C |
| Power Supply | 220 V AC, 50/60 Hz |
| Operating Ambient Temperature | 5–40 °C |
| Display | Color Touchscreen |
| Analysis Time | ≤6 minutes per sample |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–50,000 ppm (as C) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Sample Temperature Range | 1–90 °C |
| Analysis Time | <6 minutes |
| Power Supply | 220 V AC |
| Display | Color Touchscreen |
| Compliance | Chinese Pharmacopoeia 2010 Edition |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.5 mg/L |
| Accuracy | ±5% |
| Resolution | 1 µg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Power Consumption | 95 W |
| Dimensions | 340 × 390 × 145 mm |
| Weight | 15 kg |
| Response Time | ≤6 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Temperature | 10–40 °C |
| Relative Humidity | ≤85% RH |
| Linearity Error | ±5% |
| Control Interface | Color Touchscreen with Embedded System |
| Connectivity | Bluetooth Wireless Control |
| Compliance | Chinese Pharmacopoeia 2015 Edition, Appendix VIII R |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | BC-40 |
| Detection Principle | Membrane Conductivity Difference Method |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.001–1.5 mg/L |
| Accuracy | ±5% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Power Consumption | 95 W |
| Dimensions | 340 × 390 × 145 mm |
| Weight | 15 kg |
| Response Time | ≤6 min |
| Sample Temperature Range | 1–95 °C |
| Operating Environment | 10–40 °C, ≤85% RH |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Detection after UV/Persulfate Oxidation |
| Oxidation Method | High-Temperature Catalytic Combustion (supplemented by UV/persulfate for low-level precision) |
| Measurement Range | 0.01–1000 µg/L (0.01–1.000 mg/L) |
| Accuracy | ±4% of reading within calibrated range |
| Resolution | 0.001 mg/L (1 µg/L) |
| Detection Limit | 0.001 mg/L (1 µg/L) |
| Repeatability | ≤3% RSD |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | ≤6 minutes per sample |
| Data Storage | Internal memory supporting ≥6 months of timestamped records |
| Compliance | USP <643>, EP 2.2.44, ChP 2020 Edition (General Chapter 0682), FDA CGMP Annex 1 (Water Systems), ISO 8573-1 (for pharmaceutical compressed air-associated water), GLP/GMP-ready audit trail capability |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BC-40A Standard |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Analysis Time | ≤6 minutes |
| Sample Temperature Range | 1–90 °C |
| Power Supply | 220 V AC |
| Display | Color Touchscreen |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Differential Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.0 mg/L (customizable up to 1000 mg/L via sensor configuration) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | <4 minutes per sample |
| Display | 640×480 color touchscreen |
| Data Storage | 6-month history (≥10,000 records) |
| Interface | RS232 |
| Compliance | Chinese Pharmacopoeia 2010 Edition, Appendix VIII R |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | UV/Persulfate Oxidation + NDIR (Non-Dispersive Infrared) Detection |
| Measurement Range | 0.001–1.0 mg/L (customizable up to 1000 mg/L via sensor configuration) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Response Time | <4 minutes |
| Sample Temperature Range | 1–95 °C |
| Display | 640×480 color TFT touchscreen |
| Data Storage | 6-month history retention |
| Compliance | Chinese Pharmacopoeia 2010 Edition, Appendix VIII R |
| Interface | RS232 |
| Power Supply | 220 V AC |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | BC-40A |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±5% |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Analysis Time | 4 min |
| Response Time | ≤15 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Temperature Range | 10–40 °C (max. ±5 °C/day drift) |
| Internal Flow Rate | 0.5 mL/min |
| Relative Humidity | ≤85% |
| Zero Drift | ±5% FS/24 h |
| Span Drift | ±5% FS/24 h |
| UV Lamp | Dual-wavelength (185 nm & 254 nm) |
| Pump Tubing | Imported high-stability peristaltic tubing |
| Brand | ALPHA (USA) |
|---|---|
| Origin | USA |
| Model | AIC3Pro |
| Instrument Type | Handheld |
| Flow Mode | Low-flow Gerdien Tube Design |
| Repeatability | ±5% |
| Accuracy | ±20%* |
| Ion Concentration Range | 0–2×10⁶ ions/cm³ or 0–2×10⁸ ions/cm³ (selectable) |
| Resolution | 10 ions/cm³ @ 2×10⁶ range |
| Polarity Modes | Unipolar (Positive/Negative) or Bipolar (with real-time Sum calculation) |
| Polarity Switching Interval (Bipolar) | 7.5 s per polarity |
| Data Logging | Timestamped CSV to removable microSD (up to 32 GB) |
| Display | 128×128 px backlit LCD |
| Battery | 2000 mAh rechargeable Li-ion (UN38.3 certified) |
| Operating Environment | –20 °C to +43 °C, 0–85% RH (non-condensing), wind <15 km/h |
| Humidity Sensor Accuracy | ±2% RH |
| Compliance | FCC Part 15, CE EMC (BS EN 55032:2015/Cor1:2016 |
| BS EN 61000-3-2 | 2019 |
| BS EN 61000-3-3 | 2013+A1:2017 |
| BS EN 55035 | 2017/A11:2020), RoHS (EN 50581:2012) |
| Brand | ALPHA (UK) |
|---|---|
| Origin | United Kingdom |
| Model | DS2000 |
| Sensor Technology | Aluminium Oxide Capacitive |
| Measurement Range | -110°C to +20°C dew point |
| Accuracy | ±2°C over full scale |
| Display | Dual-color 7-segment, 5-digit main + 1-digit auxiliary |
| Operating Temperature | -20°C to +50°C |
| Storage Temperature | -50°C to +70°C |
| Humidity Range | 10–90% RH (non-condensing) |
| Output Options | 4–20 mA / 0–10 V linear retransmission |
| Communication | RS-485 Modbus RTU |
| Compliance | Traceable calibration to NPL and ISO/IEC 17025 accredited standards |
| Gas Compatibility | Fully compatible with SF₆, compressed air, nitrogen, argon, hydrogen, and other inert/dry process gases |
| Units Supported | °C dp, °F dp, ppm(v), g/m³, lb/MMSCF |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1027 |
| Sampling Method | Active (Pump-Driven) |
| Measurement Range | 0.1–999 pCi/L (3.7–37,000 Bq/m³) |
| Minimum Detectable Concentration | 0.1 pCi/L |
| Sensitivity | 2.5 counts per hour per pCi/L (cph/pCi/L) |
| Accuracy | ±25% or ±1 pCi/L (whichever is greater) |
| Display | 3-digit LCD |
| Power Supply | 220 VAC / 9 VDC adapter |
| Dimensions | 200 × 120 × 65 mm |
| Weight | 0.9 kg |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | AIOLOS |
| Gas Channels | 2–4 configurable |
| Inlet Pressure | 3 bar (up to 8 bar, 1 bar for LNG) |
| Outlet Pressure | Ambient (custom higher pressure available) |
| Connection | 1/8″ Swagelok |
| Dilution Ratio | Standard 1:4000, up to 1:10,000 |
| MFC Flow Range | 2–100% FS |
| Flow Accuracy | ±1% of setpoint |
| Repeatability | <0.1% of setpoint |
| Response Time | <5 s |
| Operating Temperature | 10–50 °C |
| Power Supply | 90–260 VAC, 1.5–4 A, 50–60 Hz |
| Dimensions | 42 × 22 × 46 cm (H×W×D) |
| Weight | 10.5–17.5 kg (configuration-dependent) |
| Communication | USB, Windows 7+ compatible |
| Software | Alytech GasMix™ v4.x with audit trail, sequence programming, and external device triggering |
| Compliance | ISO 6145-7 |
| Optional | Heated tubing module, remote automated calibration interface |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | AURA II |
| Evaporation Temperature Range | 40–160 °C |
| Input Pressure Range | 2–50 bar (with safety valve) |
| Output Pressure Range | 1–3 bar |
| Output Flow Rate | 20–200 cc/min |
| Operating Modes | Pressure-controlled or Flow-controlled |
| Integrated In-line Filter | 0.5 µm stainless steel |
| Standard Delivery | 1 m heated flexible transfer line |
| Power Supply | External AC adapter (battery option not specified for AURA II) |
| Accuracy | <1.5% |
| Repeatability | <1% |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | GMRACK |
| Channel Configuration | 2–6 configurable channels |
| Control Interface | Optional integrated touchscreen or external PC control |
| Power Supply | Line-powered (with optional battery for field mobility) |
| Compliance | Designed for ISO/IEC 17025-compliant calibration laboratories and EPA Method TO-14/TO-15 traceable gas standard generation |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | HURRICANE |
| Channel Capacity | 5–16 channels |
| Dilution Principle | Dynamic mass-flow-based dilution with integrated zero-air generator and permeation source support |
| Operating Mode | Portable or benchtop |
| Power | Rechargeable battery (8 h runtime) or AC mains |
| Zero Air Supply | Built-in oil-free air pump (5 L/min, filtered & dried) |
| Max Output Flow | 3000 NmL/min |
| Dilution Accuracy | < ±1.5% of setpoint |
| Reproducibility | < ±1% RSD |
| Compliance | Designed for ISO 6145-7, ISO 16017-1, ASTM D6196, EPA TO-15/TO-17 calibration traceability frameworks |
| Brand | AlyTech |
|---|---|
| Origin | France |
| Model | NEPHOS |
| Liquid Channels | 1 or 2 |
| Liquid Flow Range | 0.5–5 g/h and 0.5–200 g/h |
| Liquid Compatibility | Pure liquids or homogeneous liquid mixtures (e.g., water, organic solvents) |
| Gas Channels | 1–6 |
| Inlet Pressure | 3 bar (max 8 bar) |
| Compatible Gases | High-purity gases, concentrated standards, most corrosive and reactive gases (custom validation required for specialty gases) |
| Max Dilution Ratio | 1:10⁸ |
| Output Flow Accuracy | < ±2% of reading |
| Output Concentration Accuracy | < ±1% |
| Heated Transfer Line | Standard 1 m (custom lengths available) |
| Outlet Pressure | Ambient (higher pressure options on request) |
| Fitting Interfaces | Swagelok 1/8", 1/16", and 1/4" |
| Operating Temperature | 10–50 °C |
| Power Supply | 90–260 VAC, 1.5–4 A, 50–60 Hz |
| Dimensions (H×W×D) | 50 × 47 × 58 cm |
| Weight | 25–40 kg (configuration-dependent) |
| Communication | Ethernet, Windows 10+ PC host |
| Software | AlyTech LiqMix™ v3.x (NIST-traceable MFC & Coriolis calibration |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | NOMAD |
| Channels | 2–4 |
| Form Factor | Compact portable unit |
| Power Supply | Mains-powered (optional external PC interface) |
| Display | Optional integrated touchscreen or remote control via PC |
| Compliance | Designed for traceable gas standard generation in environmental and calibration laboratories |
| Pricing Range | USD $13,500 – $40,500 (FOB Europe, excluding VAT & shipping) |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | PerMix ATMO |
| Temperature Control Range | 40–70 °C (stability ±0.1 °C) |
| Zero Gas Generation | Integrated purified air generator (5 L/min) |
| Output Flow | Up to 3000 Nml/min |
| Power | Rechargeable battery (8 h operation) |
| Accuracy | <1.5% |
| Repeatability | <1% |
| Permeation Channels | 2 |
| Diluent | Purified ambient air |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | Zephyr |
| Configuration | Portable Dual-Channel Dynamic Gas Dilutor |
| Display | Integrated Touchscreen Interface |
| Power Options | AC Mains or Rechargeable Battery (8 h runtime) |
| Diluent Gas | Purified Air (5 L/min built-in compressor) |
| Maximum Output Flow | 3000 NmL/min |
| Accuracy | < ±1.5% of setpoint |
| Repeatability | < ±1.0% |
| Operating Temperature Range | Ambient to 40°C (external environment) |
| Compliance | Designed for ISO 6145-7 (dynamic dilution), ASTM D6166 (calibration gas generation), and GLP-compliant traceable calibration workflows |
| Brand | AMAE |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM-1026 |
| Pricing | Available Upon Request |
| Brand | AMAE |
|---|---|
| Origin | Jiangsu, China |
| Model | AM-1056 |
| Measurement Principle | Alternating Flow Modulated NDIR (Non-Dispersive Infrared) at 4.67 µm |
| Measurand | Carbon Monoxide (CO) in Ambient Air |
| Range | 0–10 / 25 / 50 ppm (field-expandable) |
| LOD | 0.2 ppm (2σ, ≤10 ppm range) or 0.5% F.S. (2σ, >10 ppm range) |
| Accuracy | ±1.0% F.S. |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±0.5 ppm/day or ±1.0% F.S./day |
| Span Drift | ±1.0% F.S./day or ±3.0% F.S./week |
| Response Time (T90) | ≤80 s |
| Sample Flow Rate | ~1 L/min |
| Dimensions | 483 mm × 545 mm × 133 mm (L×W×H) |
| Power Consumption | 50 W |
| Connectivity | Embedded Web Server (Ethernet/Wi-Fi) |
| Calibration | Scheduled Auto-Calibration Support |
| Enclosure | Industrial Rack-Mountable Chassis (19″, 3U) |
| Brand | AMAE (Guoji Instruments) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM-3000 Series |
| Pricing | Available Upon Request |
| Brand | AMAE |
|---|---|
| Origin | Jiangsu, China |
| Model | AM-3100 |
| Detection Principle | Photoionization Detection (PID) with 10.6 eV UV Lamp |
| Measurement Range | 0–10,000 ppb (as isobutylene equivalent) |
| Detection Limit | ≤1 ppb (typical) |
| Response Time (T90) | <30 s |
| Operating Temperature | 0–45 °C |
| Humidity Range | 0–90% RH (non-condensing) |
| Data Storage Capacity | ≥3 years of continuous 1-minute interval data and system logs |
| Power Supply | 220 VAC ±10%, 50 Hz with integrated UPS backup |
| Communication Interfaces | RS485, RS232, Ethernet (Modbus TCP/RTU, HTTP API), optional 4G/LTE module |
| Enclosure Rating | IP54 |
| Dimensions | 482 × 360 × 177 mm (19″ rack-mountable) |
| Compliance | CE, RoHS, GB/T 3836.1–2010 (Explosion-Proof Optional) |