| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3.5 |
| Instrument Type | Portable |
| Detection Principle | Multi-sensor array (Metal Oxide Semiconductor, Electrochemical, PID) |
| Sensor Array | 10 distinct MOS sensors |
| Software Platform | WinMuster v5.x |
| Data Analysis Algorithms | PCA, LDA, DFA, K-NN (Euclidean & Mahalanobis), PLS |
| Compliance | Designed for ISO 18562-3 (biocompatibility of gas pathways), ASTM E2147-22 (odor intensity measurement), GLP-compliant audit trail support |
| Operating Environment | 5–40 °C, 20–90% RH (non-condensing) |
| Sample Introduction | Integrated auto-sampling pump with mass-flow-controlled inlet (0.1–1.0 L/min adjustable) |
| Connectivity | USB 2.0, RS-232, optional Ethernet module for remote station integration |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Sampling Kit |
| Compliance | Designed to Support ASTM D6196, ISO 16017-1, USP <621>, EPA Method TO-17 & TO-15 Derivatives |
| Sample Matrices | Gaseous, Aerosol, Liquid (Aqueous/Organic), Solid (Soil/Sediment), Semi-solid, Biological, and Unknown Contaminants |
| Integrated Preparative Functions | Thermal Desorption, Liquid-Liquid Extraction, Headspace Equilibration, Solid-Phase Adsorption, Solvent Elution, Filtration, and Direct GC/MS Injection Compatibility |
| Accessories | Color-Coded PTFE-Sealed Vials, Tenax/Composite/Desorption Cartridges (Blue/Black/Red), Certified Deuterated Internal Standards (D6-Benzene, D8-Toluene, D10-Xylenes, D8-Naphthalene, D10-Anthracene, D10-Pyrene), Eppendorf Varipette 4720 (10 mL) & Biomaster 4830 (5 µL), Swagelok Alu-Plexiglas Fittings |
| Packaging | Ruggedized Portable Case with Modular Trays and Visual Identification System (Color-Coded by Matrix & Method) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Available Upon Request |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-5100 |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Instrument Type | Benchtop Laboratory Analyzer |
| Range | 0–4.5 mg/L as O₂ |
| Repeatability | RSD ≤ 5.0% |
| Accuracy | ±10% of reading |
| Limit of Detection | < 0.07 mg/L |
| Resolution | 1 µL |
| Sample Analysis Time | 3 min 50 s per sample |
| Heating Method | Infrared Rapid Boiling (reaches boiling within 100 s) |
| Reaction Control | User-defined oxidation holding time |
| Fluidic Architecture | Dedicated reagent addition station, titration analysis station, and waste discharge station |
| Dispensing System | Single-arm precision liquid handler for all reagents |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AKFC-92A |
| Pricing | Upon Request |
| Sampling Flow Rate | 20 L/min |
| Maximum Negative Pressure | >3000 Pa |
| Load Capacity | ≥1000 Pa |
| Dust Fraction Measurement | Total Dust & Respirable Dust |
| Timer Range | 0–99 min (adjustable) |
| Continuous Operation Time | >120 min |
| Sound Pressure Level | ≤70 dB(A) |
| Explosion Protection | ibI (150 °C) Intrinsically Safe |
| Operating Temperature | −5 °C to 35 °C |
| Relative Humidity Limit | ≤95% RH |
| Dimensions | 200 × 140 × 80 mm |
| Weight | 1.8 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | AKFC-92G |
| Pricing | Available Upon Request |
| Sampling Flow Rate | 2 L/min |
| Vacuum Pressure | >5000 Pa |
| Load Capacity | >2000 Pa |
| Dust Fraction Collection | Total Dust & Respirable Dust |
| Operating Duration | >10 h |
| Intrinsic Safety Rating | Mine-Use Intrinsically Safe (iI) |
| Acoustic Noise Level | <60 dB(A) |
| Ambient Operating Temperature | 0–35 °C |
| Relative Humidity Limit | <95% RH |
| Dimensions | 120 × 80 × 42 mm |
| Weight | 450 g |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AKS-P8018A |
| Pressure Range | 0–100 MPa |
| Adjustment Resolution | 0.1 kPa |
| Pressure Medium | P816C Hydraulic Oil |
| Pressure Port | Three M20×1.5 Female Quick-Connect Threads |
| Dimensions | 460 × 385 × 178 mm |
| Weight | 13.2 kg |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AL-430 |
| Pricing | Available Upon Request |
| Pump Type | Diaphragm Pump |
| No-Load Flow Rate | 4 L/min |
| Flow Range Options | Dual-Range Mass Flowmeter (0.07–0.7 L/min and 0.4–4 L/min) |
| Total Volume Setting Range | 1–9999 L (LCD Display) |
| Power Supply | 8 × AA Alkaline Batteries (8 h runtime) or External DC 12 V / AC 100 V |
| Telescopic Mast | Extendable to 1.5 m (PAT-Compatible Mounting) |
| Dimensions | 240(W) × 330(H) × 350(D) mm |
| Weight | 8 kg |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ALA Level Alarm Device |
| Price | Upon Request |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | DO300(1.5m) |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Clark-type Polarographic Probe |
| Range | 0–20.00 mg/L |
| Accuracy | ±0.30 mg/L |
| Repeatability | 0.1% |
| Detection Limit | 0.10 mg/L |
| Temperature Compensation | Automatic (0–45 °C) |
| Salinity Compensation | Automatic (0–45 ppt) |
| Barometric Pressure Compensation | Manual (80–105 kPa) |
| Response Time | 30 s (90% at 25 °C) |
| Display | 68 × 53 mm LCD with white backlight and time stamp |
| Data Storage | 500 sets (manual & auto), GLP-compliant |
| IP Rating | IP57 |
| Interface | USB |
| Operating Temperature | −10 to 110 °C |
| Resolution | DO: 0.01/0.1 mg/L |
| Saturation | 0.1/1 % |
| Temp | 0.1 °C |
| Residual Current | ≤0.10 mg/L |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | DO300(5m) |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Clark-type Polarographic Sensor |
| Range | 0–20.00 mg/L |
| Accuracy | ±0.30 mg/L |
| Repeatability | 0.1% |
| Detection Limit | 0.10 mg/L |
| Temperature Compensation | Automatic (0–45 °C) |
| Salinity Compensation | Automatic (0–45 ppt) |
| Barometric Pressure Compensation | Manual (80–105 kPa) |
| Response Time | 30 s (90% at 25 °C) |
| Residual Current Equivalent | 0.10 mg/L |
| Data Storage | 500 sets (manual & auto) |
| Display | 68 × 53 mm LCD with white backlight and time stamp |
| IP Rating | IP57 |
| Interface | USB |
| GLP Compliance | Yes |
| Temperature Range (sensor) | −10 to 110 °C |
| Resolution | DO: 0.01/0.1 mg/L |
| Saturation | 0.1/1 % |
| Temp | 0.1 °C |
| Basic Error (Temp) | ±0.4 °C |
| Brand | Alalis |
|---|---|
| Model | DO410 |
| Origin | Shanghai, China |
| Instrument Type | Laboratory Benchtop Meter |
| Measurement Principle | Polarographic Electrochemical Probe |
| Dissolved Oxygen Range | 0–20.00 mg/L (ppm) |
| Saturation Range | 0.0–200.0 % |
| Temperature Range | −10 to 110 °C |
| Accuracy (DO) | ±0.30 mg/L |
| Accuracy (Temp) | ±0.4 °C |
| Resolution (DO) | 0.01/0.1 mg/L |
| Resolution (Saturation) | 0.1/1 % |
| Resolution (Temp) | 0.1 °C |
| Repeatability | 0.1 % |
| Detection Limit | 0.10 mg/L |
| Response Time | 30 s (90 % at 25 °C) |
| Residual Current Equivalent | 0.10 mg/L |
| Temperature Compensation | Automatic (0–45 °C) |
| Salinity Compensation | Automatic (0–45 ppt) |
| Atmospheric Pressure Compensation | Automatic (80–105 kPa) |
| Data Storage | 500 sets (manual & auto) |
| Display | 90 × 68 mm LCD with white backlight and time stamp |
| IP Rating | IP54 |
| Interface | USB port with included software and cable |
| Power | 9 V AC adapter |
| Electrode | Integrated temperature- and salinity-compensated polarographic probe with replaceable membrane cap and internal electrolyte |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | MP3500 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic Electrochemical Probe |
| DO Range | 0–20.00 mg/L |
| Accuracy (DO) | ±0.30 mg/L |
| Repeatability | 0.1% |
| Detection Limit | 0.01 mg/L |
| DO Temperature Compensation | 0–45 °C |
| DO Salinity Compensation | 0–45 ppt |
| Barometric Pressure Compensation | 80–105 kPa |
| IP Rating | IP57 |
| Data Storage | 1000 sets (GLP-compliant) |
| Display | 68 × 53 mm LCD with white backlight |
| Interface | USB |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | MP6500 |
| Instrument Type | Laboratory Benchtop |
| Measurement Principle | Electrochemical Clark-type Polarographic Sensor |
| DO Range | 0–20.00 mg/L |
| DO Accuracy | ±0.30 mg/L |
| DO Repeatability | 0.1% |
| Detection Limit | 0.10 mg/L |
| Temperature Compensation | 0–45 °C (auto), Salinity Compensation: 0–45 ppt (auto), Barometric Pressure Compensation: 80–105 kPa (manual) |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PD320 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Clark-type Polarographic Probe |
| Dissolved Oxygen Range | 0.0–20.0 mg/L |
| Accuracy (DO) | ±0.30 mg/L |
| Repeatability | 0.1% |
| Detection Limit (DO) | 0.10 mg/L |
| pH Range | −2.00–19.99 pH |
| mV Range | ±1999 mV |
| Temperature Range | −10–110 °C |
| DO Saturation Range | 0.0–200.0 % |
| pH Resolution | 0.01/0.1 pH |
| mV Resolution | 1 mV |
| DO Saturation Resolution | 0.1/1 % |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH |
| mV Accuracy | ±0.1% FS |
| Temperature Accuracy | ±0.4 °C |
| Response Time (DO) | 30 s (90% at 25 °C) |
| Residual Current | 0.10 mg/L |
| IP Rating | IP57 |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PD5200 |
| Instrument Type | Laboratory |
| Measurement Principle | Electrochemical Clark-type Polarographic Probe |
| Dissolved Oxygen Range | 0–20.00 mg/L |
| Accuracy (DO) | ±0.30 mg/L |
| Repeatability | 0.1% |
| Detection Limit (DO) | 0.10 mg/L |
| pH Range | −2.000–19.999 |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10–100 °C |
| Temp Accuracy | ±0.4 °C |
| Response Time (DO) | 30 s (90% at 25 °C) |
| Residual Current | 0.10 mg/L |
| DO Electrode | Membrane-covered polarographic sensor with integrated temperature compensation and salinity/pressure compensation |
| pH Calibration | Up to 5-point auto-calibration with NIST, USA, CH, and custom buffer sets (15 total) |
| Data Storage | 1000 entries (manual/auto), GLP-compliant |
| Connectivity | USB interface |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight and time stamp |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Br |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Ca |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Measurement Accuracy | ±0.01 pX (for monovalent ions) / ±0.02 pX (for divalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX, 0.01 mol/L, 0.01 mg/L, 0.01 ppm |
| pH Range | −2.000–19.999 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | −1999.9 to +1999.9 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Accuracy | ±0.4 °C |
| Data Storage Capacity | 1000 sets |
| Interface | USB |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Brand | Alalis |
|---|---|
| Model | PI5100-CL |
| Type | Benchtop Ion Concentration Meter |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000–19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Protection Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-F |
| Instrument Type | Benchtop Ion Analyzer |
| Ion Measured | Fluoride (F⁻) |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | ≤1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-I |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-K |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Protection Rating | IP54 |
| Compliance | GLP-compliant data management, ASTM D1129, ISO 7888, USP <791>, FDA 21 CFR Part 11-ready audit trail support |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Na |
| Instrument Type | Benchtop Sodium Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | ≤1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management, supports ASTM D1129, ISO 10523, and USP <791> for ion-selective electrode methodology |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ALD Condensate Drain Unit |
| Pricing | Upon Request |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ALG-300 |
| Pricing | Available Upon Request |
| Brand | CTG |
|---|---|
| Origin | UK |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Parameter | Algal Pigments (Chlorophyll-a, Phycocyanin, Phycoerythrin) and Turbidity |
| Sensor Technology | Submersible Fluorescence Probe (TriLux Series) |
| Data Logger | Hawk Handheld Terminal (IP68-rated, Touchscreen, 2 GB Internal Storage) |
| Power Options | Rechargeable or Disposable Batteries |
| Compliance | Designed for Field-Deployable Environmental Monitoring per ISO 10260, ASTM D3921, and EPA Method 445.0 (Chlorophyll-a by Fluorometric Determination) |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | PTR-TOF MS 2500 |
| Detection Principle | Proton Transfer Reaction (H₃O⁺-based soft ionization) |
| Instrument Type | Online Real-Time Analyzer |
| Configuration | Integrated VOC Monitoring System |
| Mass Resolution (m/Δm) | ≥ 6,000 (FWHM at m/z 100) |
| Mass Range | m/z 10–300 |
| Detection Limit | < 10 pptv (for formaldehyde, 1 s integration) |
| Data Acquisition Rate | Up to 10 Hz full-spectrum |
| Vacuum System | Multi-stage differential pumping with turbomolecular pumps |
| Ion Source | RF-driven hollow cathode H₃O⁺ generator |
| Mass Analyzer | Orthogonal acceleration reflectron TOF |
| Software Platform | ALIBEN Control Suite v4.2 (GLP-compliant audit trail, 21 CFR Part 11 ready) |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | PTR-TOF MS 6000 |
| Detection Principle | Proton Transfer Reaction (H₃O⁺-based soft ionization) |
| Instrument Type | Online Real-time Analyzer |
| Configuration | Integrated VOCs Monitoring System |
| Mass Resolution (m/Δm) | ≥ 6,000 (FWHM at m/z 100) |
| Mass Range | m/z 10–500 |
| Detection Limit | < 10 pptv (for common VOCs, 1-s integration) |
| Response Time | < 100 ms |
| Vacuum System | Multi-stage differential pumping with turbomolecular pumps |
| Ion Source | Radiofrequency-guided H₃O⁺ primary ion source |
| Analyzer | Orthogonal acceleration reflectron TOF mass analyzer |
| Data Acquisition Rate | Up to 10 spectra per second |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | PTR-TOF MS 8000 |
| Detection Principle | Proton Transfer Reaction (H₃O⁺-based soft ionization) |
| Instrument Type | Online Real-Time Analyzer |
| Configuration | Integrated VOCs Monitoring System |
| Mass Resolution (m/Δm) | ≥ 8,000 (FWHM at m/z 100) |
| Mass Range | m/z 10–500 |
| Detection Limit | < 10 pptv (for common VOCs, 1-s integration) |
| Data Acquisition Rate | Up to 10 Hz full-spectrum acquisition |
| Vacuum System | Multi-stage differential pumping with turbomolecular pumps |
| Ion Source | RF-driven hollow cathode H₃O⁺ generator |
| Mass Analyzer | Orthogonal acceleration reflectron TOF |
| Software Platform | ALIBEN Acquire v3.2 with real-time spectral deconvolution and compound identification engine |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UVP-TOF MS 2000 LITE |
| Detection Principle | Vacuum Ultraviolet Photoionization (VUV-PI) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Analyzer |
| Configuration | Multi-Component VOC & Inorganic Gas Monitor |
| Detection Range | 0–1 ppbv (extendable to % v/v) |
| Mass Resolution (FWHM) | >2000 |
| Accuracy | RSD <3% |
| Response Time | <1 s |