Environmental Monitoring Instruments
Filter
Showing 721–750 of 2621 results
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Country of Origin | Imported |
| Model | DFP |
| Portability | Portable |
| Target Organism | Cyanobacteria (Phytoplankton) |
| Operating Temperature Range | −2 °C to 40 °C |
| Reagent Storage Temperature | −2 °C to 40 °C |
| Measurement Cycle Time | 7 hours |
| Depth Range | 0–100 m |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Product Type | Online Water Toxicity Analyzer |
| Model | Fish Toximeter II |
| Operating Temperature Range | 5–28 °C |
| Test Organism | Zebrafish (Danio rerio) |
| Detection Principle | Real-time Video-Based Behavioral Analysis |
| Compliance Basis | Extended Dynamic Daphnia Test (EDDT)-aligned methodology, aligned with ISO 10706:2000 (Water quality — Guidance on toxicity testing using fish), EU WFD (Water Framework Directive) monitoring principles |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Type | Imported |
| Model | TS |
| Application | Field-deployable chlorophyll a and algal class quantification |
| Measurement Principle | Multi-wavelength excitation fluorescence spectroscopy |
| Detection Depth | Up to 1000 m (optional) |
| Key Parameters | Total chlorophyll a (0–500 µg/L, resolution 0.01 µg/L, LOD 0.05 µg/L), yellow substance (CDOM), green algae, cyanobacteria, diatoms/dinoflagellates, cryptophytes, depth (0–100/200/1000 m), temperature (−2 to 40 °C), transmittance (0–100%), pressure sensor integrated |
| Power | 12 V DC, internal rechargeable battery |
| Housing | Reinforced carbon fiber / V4A stainless steel (6.4 kg standard, 7.2 kg with housing, 5.1 kg titanium option) |
| Dimensions | 450 mm × 140 mm (H × Φ) |
| Memory | 2 GB (≥1000 datasets) |
| Interface | RS485 |
| Maintenance Interval | ≥7 days |
| Optional Accessories | Desktop mount, temperature probe, wiper unit, protective housing, cable reel, auto-start plug, Bluetooth handheld interface, transport case, cables (3/10/20/30/50/100 m) |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Ver. 1.1 |
| Instrument Type | Algal Quality Control System |
| Compliance | Designed for ISO/IEC 17025-aligned QC workflows in environmental laboratories |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | BG00430000 |
| Measurement Parameters | Total chlorophyll a / total algal density |
| Measurement Range | 0–500 µg chl-a/L |
| Resolution | 0.01 µg chl-a/L |
| Detection Limit | 0.05 µg chl-a/L |
| Light Transmission Range | 0–100% |
| Excitation Wavelengths | 370, 470, 525, 570, 590, 610 nm |
| Measurement Time | ≤3 min per sample |
| Sample Volume | 25 mL |
| Operating Temperature | 0–35 °C |
| Storage Temperature | 0–50 °C |
| Dimensions (H×W×D) | 185 × 330 × 350 mm |
| Weight | 7.5 kg |
| Power Supply | 110/240 V AC, 50/60 Hz or 12 V DC |
| Power Consumption | 10 W |
| Protection Rating | IP54 |
| Data Interface | RS232 |
| Software | bbe++ (Windows-based database software) |
| Optional Accessories | Photosynthetic activity module |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0–8 mg/L and 0–20 mg/L (dual-range auto-switching) |
| Repeatability | ±3% of Full Scale (FS) |
| Accuracy | ≤±3% FS |
| Limit of Detection (LOD) | 0.4 mg/L |
| Resolution | 0.01 mg/L |
| Analysis Cycle Time | 60 minutes per sample |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TC |
| Instrument Type | Algal Cell Counter |
| Detection Principle | In Vivo Chlorophyll-a Fluorescence Analysis |
| Measurement Range | 0–20,000 cells/mL |
| Resolution | 1 cell/mL |
| Weight | 2.5 kg |
| Dimensions (H×W×D) | 258 × 243 × 117 mm |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Protection Rating | IP54 (lid closed), IP22 (lid open) |
| Interface | USB |
| Sample Temperature Range | 5–55 °C |
| Ambient Operating Temperature | 5–35 °C |
| Data Storage Capacity | >100,000 measurements |
| Storage Temperature | 5–45 °C |
| Accessories Included | User Manual, 50 µm Filter, Power Adapter, 50-Filter Kit |
| Optional Accessory | 50-Filter Kit |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-Made) |
| Model | bbe NH4—PWR II |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Ammonia-Nitrogen (NH₃-N) |
| Measurement Principle | Salicylate Spectrophotometry |
| Detection Range | 0–0.5 / 2 / 4 / 20 / 100 mg/L NH₃-N (selectable) |
| Accuracy | ≤ ±3% FS or 0.0014 mg/L (whichever is greater) |
| Repeatability | ≤2% |
| Limit of Detection (LOD) | 0.0027 mg/L (at 0–0.5 mg/L range) |
| Zero Drift | ≤1% FS/24 h |
| Span Drift | ≤2% FS/24 h |
| Measurement Cycle Time | 500 s |
| Resolution | 0.0001 mg/L (at 0–0.5 mg/L range) |
| Dimensions (H×L×W) | 1100 × 600 × 310 mm |
| Weight | ~45 kg |
| Sample Requirements | Oil-free, low-suspended solids |
| Temp | 2–40 °C |
| Pressure | 0.0–0.1 bar |
| Flow Rate | 1.5–3.0 L/min |
| Output Interfaces | 4–20 mA analog, RS232/RS485 serial |
| Communication Protocols | MODBUS RTU/TCP (optional), TCP/IP (optional) |
| Calibration | Automatic & manual |
| Maintenance | Modular design with tool-free access |
| Display | Integrated touchscreen HMI |
| Data Integrity Features | Built-in QC check verification, remote status monitoring (optional) |
| Environmental Compliance | Designed for continuous operation in Class I, Division 2 hazardous locations per IEC 60079-0 (general requirements) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | bbe Phenol—PWR II |
| Instrument Type | Online Water Quality Analyzer |
| Analyte | Volatile Phenol |
| Measurement Range | 0–0.1 / 2 / 20 mg/L (selectable) |
| Detection Limit | 0.001 mg/L (at lowest range) |
| Accuracy | ≤ ±3% FS or 0.0008 mg/L (whichever is greater) |
| Repeatability | ≤3% |
| Zero Drift | ≤2% FS/24h |
| Span Drift | ≤2% FS/24h |
| Measurement Cycle Time | 39 minutes |
| Resolution | 0.0001 mg/L (at lowest range) |
| Dimensions (H×L×W) | 1100 × 600 × 310 mm |
| Weight | ~45 kg |
| Sample Requirements | Oil-free and particle-free |
| Temperature | 2–40 °C |
| Pressure | 0.0–0.1 bar |
| Flow Rate | 1.5–3.0 L/min |
| Output Interfaces | 4–20 mA, RS232/RS485 |
| Communication Protocols | MODBUS RTU/TCP (optional), TCP/IP (optional) |
| Calibration | Automatic & manual |
| Cleaning | Fully automated |
| Compliance Features | Built-in QC verification, remote operational status monitoring (optional) |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Type | Laboratory Instrument |
| Model | PhycoLA |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Sample Volume per Batch | 25 mL |
| Biological Target | Cyanobacteria and Algal Taxa |
| Application Domain | Freshwater and Brackish Water Quality Monitoring |
| Brand | bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | bbe Moldaenke GmbH |
| Country of Origin | Imported |
| Model | PS |
| Instrument Type | Online |
| Biological Target | Algae |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Sample Volume per Cycle | 45 mL |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | bbe TN—PWR II |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Total Nitrogen (TN) |
| Measurement Principle | Alkaline Potassium Persulfate Digestion + UV-Vis Spectrophotometry |
| Measurement Range | 0–2.5 / 10 / 50 / 350 mg/L TN (selectable) |
| Accuracy | ≤ ±3% FS or ±0.05 mg/L (whichever is greater) |
| Repeatability | ≤2% RSD |
| Detection Limit | 0.05 mg/L (at lowest range) |
| Zero Drift | ≤3% FS/24 h |
| Span Drift | ≤3% FS/24 h |
| Measurement Cycle Time | 21 minutes |
| Resolution | 0.01 mg/L (at lowest range) |
| Dimensions (H×L×W) | 1190 × 600 × 310 mm |
| Weight | ~45 kg |
| Sample Requirements | Oil-free, low-suspended solids |
| Temp. | 2–40 °C |
| Pressure | 0–0.1 bar |
| Flow Rate | 1.5–3.0 L/min |
| Output Interfaces | 4–20 mA analog output, RS232/RS485 serial communication |
| Protocol Support | MODBUS RTU/TCP (optional), TCP/IP (optional) |
| Key Features | Full-spectrum UV-Vis detection (220 nm, 275 nm, 400 nm, 700 nm), turbidity interference correction, integrated UV-assisted digestion, automatic calibration & cleaning, touchscreen HMI, remote status monitoring & QC verification (optional), power-fail recovery |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | bbe TP—PWR II |
| Instrument Type | Online Water Quality Analyzer |
| Analyte | Total Phosphorus |
| Measurement Principle | Acidic Peroxysulfate Digestion + Ammonium Molybdate Spectrophotometry (λ = 880 nm) |
| Detection Limit | 0.0035 mg/L (at 0–0.5 mg/L range) |
| Accuracy | ≤ ±3% FS or ±0.003 mg/L (whichever is greater) |
| Repeatability | ≤1% |
| Zero Drift | ≤1% FS/24h |
| Span Drift | ≤2% FS/24h |
| Measurement Cycle | 30 minutes |
| Resolution | 0.0001 mg/L (0–0.5 mg/L range) |
| Dimensions (H×L×W) | 1100 × 600 × 310 mm |
| Weight | ~45 kg |
| Sample Requirements | Oil-free, low-suspended solids |
| Temp. | 2–40 °C |
| Pressure | 0.0–0.1 bar |
| Flow Rate | 1.5–3.0 L/min |
| Output Interfaces | 4–20 mA analog, RS232/RS485 serial |
| Communication Protocols | MODBUS RTU/TCP (optional), TCP/IP (optional) |
| UV-Assisted Digestion | Integrated |
| QC Verification & Remote Monitoring | Optional |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Total Nitrogen (TN), Total Phosphorus (TP) |
| Measurement Principle (TN) | Alkaline Potassium Persulfate Digestion + UV-Vis Spectrophotometry |
| Measurement Principle (TP) | Acidic Potassium Persulfate Digestion + Ammonium Molybdate Spectrophotometry |
| Detection Range (TN) | 0–2.5 / 10 / 50 / 350 mg/L |
| Detection Range (TP) | 0–2 / 5 / 10 / 100 mg/L |
| Accuracy (TN) | ≤ ±3% FS or 0.05 mg/L (whichever is greater) |
| Accuracy (TP) | ≤ ±3% FS |
| Repeatability | ≤2% for both TN and TP |
| LOD (TN) | 0.05 mg/L |
| LOD (TP) | 0.0035 mg/L |
| Zero Drift (TN) | ≤3% FS/24h |
| Zero Drift (TP) | ≤1% FS/24h |
| Span Drift (TN) | ≤3% FS/24h |
| Span Drift (TP) | ≤2% FS/24h |
| Measurement Cycle (TN) | 21 min |
| Measurement Cycle (TP) | 30 min |
| Resolution | 0.01 mg/L (at minimum range) |
| Dimensions (H×L×W) | 1190 × 600 × 310 mm |
| Weight | ~45 kg |
| Sample Requirements | Oil-free, low-suspended solids |
| Temp. | 2–40 °C |
| Pressure | 0.0–0.1 bar |
| Flow Rate | 1.5–3.0 L/min |
| Output Interfaces | 4–20 mA analog, RS232/RS485 serial |
| Communication Protocols | MODBUS RTU/TCP (optional), TCP/IP (optional) |
| Key Hardware | Diode Array Spectrometer (UV–Vis, 190–800 nm), Integrated UV-Assisted Digestion Module |
| Calibration | Automatic & Manual |
| Maintenance | Modular Design with Tool-Free Access |
| Display | Touchscreen HMI (Human-Machine Interface) |
| Data Integrity Features | Audit Trail Ready, QC Check & Verification Logging (optional), Remote Status Monitoring (optional) |
| Brand | bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | bbe TP+TN+NH4—PWR II |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Total Phosphorus (TP), Total Nitrogen (TN), Ammonia-Nitrogen (NH₄–N) |
| Measurement Principles | TN – Alkaline Potassium Persulfate Digestion + UV Spectrophotometry |
| Measurement Ranges | TN: 0–2.5 / 10 / 50 / 350 mg/L |
| TP | 0–2 / 5 / 10 / 100 mg/L |
| NH₄–N | 0–0.5 / 2 / 4 / 20 / 100 mg/L |
| Accuracy | TN: ≤ ±3% FS or 0.05 mg/L (whichever greater) |
| TP | ≤ ±3% FS |
| NH₄–N | ≤ ±3% FS or 0.015 mg/L (whichever greater) |
| Repeatability | ≤2% for all parameters |
| Detection Limits | TN: 0.05 mg/L |
| TP | 0.0035 mg/L |
| NH₄–N | 0.0027 mg/L |
| Zero Drift | TN: ≤3% FS/24h |
| TP & NH₄–N | ≤1% FS/24h |
| Span Drift | TN: ≤3% FS/24h |
| TP & NH₄–N | ≤2% FS/24h |
| Measurement Cycle Time | TN: 21 min |
| TP | 30 min |
| NH₄–N | 8.4 min |
| Resolution | TN: 0.01 mg/L (min range) |
| TP | 0.001 mg/L (min range) |
| NH₄–N | 0.0001 mg/L (min range) |
| Dimensions (H×L×W) | 1190 × 600 × 310 mm |
| Weight | ~45 kg |
| Sample Requirements | Oil-free, low-suspended solids |
| Temp | 2–40 °C |
| Pressure | 0.0–0.1 bar |
| Flow Rate | 1.5–3.0 L/min |
| Key Technologies | Diode Array Full-Spectrum Detection (UV–Vis), Turbidity Interference Compensation, UV-Assisted Digestion, Modular Architecture, Touchscreen HMI, Remote Status Monitoring (optional), QC Check & Audit Trail Support (optional), Communication: 4–20 mA, RS232/RS485, MODBUS TCP/IP (optional) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory-Scale Offline TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±5% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% RSD |
| Analysis Time | 4 min |
| Response Time | ≤15 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Operating Temperature | 10–40 °C (±5 °C/day max) |
| Internal Flow Rate | 0.5 mL/min |
| Relative Humidity | ≤85% |
| Zero Drift | ±5% FS |
| Span Drift | ±5% FS |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz, 100 W |
| Dimensions | 44 × 18 × 26 cm |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | BKS-3000 |
| Instrument Type | Flue Gas CEMS |
| Accuracy | ≤±1% FS/24h |
| Repeatability | ≤±1% FS/24h |
| Response Time | ≤10 s |
| Stability (Zero/Scale Drift) | ≤±1% FS/24h (gaseous), negligible drift (particulate) |
| Measured Parameters | SO₂, NOₓ (NO, NO₂, N₂O), CO, CO₂, SO₃, CH₄, O₂, HCl, NH₃, HF, H₂S, H₂O, particulate matter (PM) |
| Detection Methods | Non-Dispersive Infrared (NDIR), Tunable Diode Laser Absorption Spectroscopy (TDLAS), UV Differential Optical Absorption Spectroscopy (UV-DOAS), Electrochemical (O₂), Optical Scattering (PM) |
| Output Interfaces | RS232, RS485, 4–20 mA, Ethernet, 4G/5G cellular |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | KPV-2000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Parameters | Temperature, Pressure, Velocity |
| Temperature Range | 0–500 °C (customizable up to 1100 °C) |
| Pressure Range | −8 to +8 kPa |
| Velocity Range | 5–40 m/s |
| Measurement Methods | Pt100 resistance thermometer (temperature), piezoresistive pressure transducer (pressure), Pitot tube differential pressure method (velocity) |
| Accuracy | ±2% relative error |
| Power Consumption | < 0.04 kVA |
| Output Signal | 4–20 mA analog |
| Environmental Rating | Rated for continuous operation at ambient housing temperatures up to 1100 °C |
| Additional Feature | Integrated automatic purge system |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | KSP-L-1000 (Extractive) |
| Measurement Principle | Laser Light Scattering |
| Safety Rating | Non-Explosive |
| Measurement Range | 0–5–200 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±2% FS |
| Relative Error | ≤±2% FS |
| Zero Drift | ≤±2% FS/24h |
| Span Drift | ≤±2% FS/24h |
| Detection Limit | 0.01 mg/m³ |
| Sampling Flow Rate | Up to 250 L/min |
| Heating Temperature | Full-Path Heated Sampling Line (Typical Setpoint: 120–180°C) |
| Calibration | Automated Zero & Span Calibration |
| Carrier Gas | Integrated Air Pump (Frost-Resistant Design) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-3000 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Analytes | Ethyl Mercaptan, Tetrahydrothiophene (THT), Acrylic Ester |
| Measurement Range | 0–100 ppm |
| Accuracy | ±1 ppm or ±2% of reading (whichever is greater) |
| Zero/ Span Drift | ≤±2% FS/24 h |
| Response Time (T90) | ≤90 s |
| Sampling Method | Extractive |
| Output Interfaces | 4–20 mA, RS-232 / RS-485, USB, Ethernet |
| Enclosure Rating | IP65 |
| Explosion Protection | Ex d IIB T4 Gb |
| Power Supply | 220 V AC |
| Brand | BCC |
|---|---|
| Model | MGA-3000 |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Configuration | Fixed-Mount |
| Detection Range | 0–10 / 50 / 100 / 500 / 1000 ppm to 100% vol (gas-dependent, customizable) |
| Sensitivity | 1 ppb |
| Response Time | T90 ≤ 60 s |
| Repeatability | ≤ ±1 % FS |
| Accuracy | ≤ ±2 % FS |
| Zero Drift | ≤ ±1 % FS / 24 h |
| Detection Limit | 0.1–1 ppm (varies by target gas) |
| Output Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet |
| Enclosure Options | 19″ rack-mount, benchtop, portable |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-3000Ex |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Type | Fixed-Mount Industrial Analyzer |
| Detection Range | 1 ppb to 100% vol |
| Sensitivity | 1 ppb (for select gases) |
| Response Time | T90 ≤ 60 s |
| Repeatability | ≤ ±1% FS |
| Accuracy | ±0.1–2% FS (gas-dependent) |
| Zero/Full-Scale Auto-Calibration | Yes |
| Drift | ≤ ±1% FS / 24 h |
| Output Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet (TCP/IP) |
| Enclosure Options | 19" rack-mount, benchtop |
| Certified Protection | Ex d IIB T4 Gb / Ex tb IIIC T130°C Db (IEC 60079-0, -1, -7, -31) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-3000P (Ammonia-Specific) |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Type | Portable Multicomponent Gas Analyzer |
| Measurement Range | 1 ppb to 100% vol NH₃ (customizable) |
| Sensitivity | 1 ppb (NH₃) |
| Response Time | T₉₀ ≤ 20 s |
| Repeatability | ±1–2% FS |
| Zero/ Span Drift | ≤ ±1% FS / 24 h |
| Power Consumption | < 100 W |
| Output Interfaces | 4–20 mA, RS232 / RS485, USB, Ethernet (TCP/IP) |
| Brand | BCC |
|---|---|
| Model | MGA-3000P |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Type | Portable |
| Detection Range | 0.1 ppm to 100% vol |
| Sensitivity | 0.01 ppm |
| Response Time (T90) | ≤30 s |
| Repeatability | ±1–2% FS |
| Zero/ Span Drift | ≤±1% FS / 24 h |
| Detection Limits | 0.1–1 ppm (gas-dependent) |
| Power Consumption | <100 W |
| Data Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet |
| Sample Handling | Dual-mode (cold-dry and hot-wet) |
| Gas Selectivity | Enhanced via Gas Correlation Filtering (GCF) |
| Simultaneous Channels | Up to 7 gas components |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MGA-6000 |
| Sampling Method | Extractive |
| Power Supply | 220 V AC |
| Explosion Protection | Ex d IIB T4 |
| Ingress Protection | IP65 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Analytes | Ethyl Mercaptan, Tetrahydrothiophene (THT), Acrylic Ester |
| Measurement Range | 0–100 ppm |
| Response Time (T90) | ≤60 s |
| Accuracy | ±1 ppm or ±1% of reading (whichever is greater) |
| Zero/ Span Drift | ≤±1% FS / 24 h |
| Output Interfaces | 4–20 mA, RS-232 / RS-485, USB, Ethernet |
| Brand | BCC |
|---|---|
| Model | MGA-6000 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Detection Range | 0–1 ppm to 0–100% (selectable, multi-range auto-switching) |
| Sensitivity | 1 ppb (gas-dependent) |
| Response Time | T90 ≤ 20 s |
| Repeatability | ≤ ±1% FS |
| Zero/Scale Drift | ≤ ±1% FS / 24 h |
| Operating Temperature Stability | Active thermal control with proprietary temperature management |
| Enclosure Options | 19" rack-mount, benchtop, and portable configurations |
| Data Interfaces | 4–20 mA analog output, RS232 / RS485 serial, USB, Ethernet (TCP/IP) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-6000Ex |
| Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Type | Fixed-mount |
| Detection Range | ppb to 100% vol |
| Sensitivity | 1 ppb |
| Response Time | T90 ≤ 20 s |
| Repeatability | ≤ ±1% FS |
| Accuracy | 0.1–2% FS |
| Drift | ≤ ±1% FS / 24 h |
| Output Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet (TCP/IP) |
| Auto-Calibration | Zero & Span |
| Certified Protection | Ex d IIB T4 Gb / Ex tb IIIC T130°C Db (IEC 60079-0, -1, -7, -31) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-6000P |
| Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Type | Portable |
| Detection Range | ppb to 100% (gas-dependent) |
| Sensitivity | 1 ppb |
| Response Time (T90) | ≤20 s |
| Repeatability | 1–2% FS |
| Drift | ≤±1% / 24 h |
| Power Consumption | <100 W |
| Detection Limits | 1 ppb – 1 ppm (varies by target gas) |
| Data Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet |
| Brand | BCC |
|---|---|
| Model | MGA-8000 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) with Off-Axis ICOS |
| Detection Range | 0–1 / 10 / 50 / 100 / 500 ppm (selectable per gas) |
| Detection Limit | <1 ppb (gas-dependent) |
| Response Time (T90) | ≤20 s |
| Repeatability | ≤±0.1% FS |
| Drift | ≤±1% FS / 24 h |
| Temperature Control Stability | ±0.005 °C |
| Pressure Control Stability | ±0.0002 atm |
| Sample Temperature Range | −10 to +50 °C |
| Output Interfaces | 4–20 mA, RS-232 / RS-485 (Modbus RTU), USB, Ethernet |
| Power Supply | 200–240 VAC, 50/60 Hz |
| Enclosure Options | 19″ rack-mount, benchtop, portable |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA6000 |
| Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Type | Fixed-Installation Multicomponent Gas Analyzer |
| Measurement Target | H₂O vapor in gas streams |
| Detection Range | 0–10 / 50 / 100 / 500 / 1000 ppm up to % level (configurable) |
| Limit of Detection (LOD) | 10 ppb |
| Response Time (T90) | ≤20 s |
| Repeatability | ≤±1% FS |
| Output Interfaces | RS-485, Ethernet (TCP/IP) for DCS integration |
| Data Storage | Embedded SSD with 5-year local retention |
| Design | Modular, maintenance-free architecture |
| Consumables | None |