| Brand | ASIDA |
|---|---|
| Model | LZ21 |
| Type | Sodium Ion–Specific Dynamic Conductivity-Based Ionic Contamination Tester for Printed Circuit Boards |
| Measurement Principle | Dynamic Extraction + Conductivity Monitoring per IPC-TM-650 2.3.25.1 & J-STD-001 |
| Operating Temperature | 40 °C ± 0.3 °C |
| Extractant Volume Options | 17 L (standard), 30 L (enlarged) |
| PCB Test Area Range | 1200–8712 cm² |
| Conductivity Resolution | 0.0001 µS/cm² |
| Accuracy | ±5% |
| Power | 1700 W |
| Dimensions (enlarged) | 1401 × 600 × 1000 mm |
| Weight (enlarged) | ~150 kg |
| Compliance | IPC-TM-650, J-STD-001, ISO 9001-aligned test environment control |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ASM IV Series |
| Instrument Type | Portable Dose Rate Meter |
| Measurement Target | Nuclear Radiation |
| Detector Type | Plastic Scintillator |
| Application Scope | Radiological Contamination Incidents |
| Sensitivity | High |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ASP Gas Measurement Probe |
| Pricing | Upon Request |
| Frequency Range | 20 Hz–8 kHz |
|---|---|
| Measurement Range | 30 dB–130 dB(A) |
| Exposure Range | 0–19.99 Pa²·h |
| Time Weighting | Fast (F), Slow (S) |
| Frequency Weighting | A-weighting |
| Measurement Durations | 10 s, 1 min, 5 min, 10 min, 15 min, 30 min, 1 h, 4 h, 8 h, 24 h |
| Microphone | Φ12.7 mm electret condenser sensor |
| Operating Voltage | 2.2–3.3 V DC |
| Battery | 2 × AAA, >24 h operation |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 20–90 % RH |
| IP Rating | IP54 |
| Intrinsic Safety Certification | Exib I Mb |
| Dimensions | 116 × 61 × 25 mm |
| Weight | 160 g |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ASR6 |
| Price Range | USD 280–700 |
| Frequency Range | 20 Hz–12.5 kHz |
| Measurement Range | 70–140 dB |
| Accuracy | ±1.5 dB |
| Measurement Durations | 10 s, 1 min, 5 min, 10 min, 15 min, 30 min, 1 h, 4 h, 8 h, 24 h |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | INFRAGAS109 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Max. Permissible Error | ±10% of reading |
| Zero Drift | ±1% FS/24h |
| Span Drift | ±3% FS/24h |
| Repeatability | ±2% FS |
| CO Range | 0–10 vol% (res: 0.001 vol%) |
| CO₂ Range | 0–20 vol% (res: 0.01 vol%) |
| HC Range | 0–15,000 ppm (res: 1 ppm) |
| O₂ Range | 0–25 vol% (res: 0.01 vol%) |
| True CO Range | 0–15 vol% (res: 0.01 vol%) |
| NOₓ Range (optional) | 0–5,000 ppm (res: 1 ppm) |
| AFR | 7–23 (res: 0.1) |
| λ (Lambda) | 0.5–1.5 (res: 0.01) |
| RPM | 0–9,999 rpm (res: 1 rpm) |
| Oil Temperature | 0–150 °C (res: 0.1 °C) |
| Internal Temp | 0–50 °C (res: 0.1 °C) |
| Ambient Pressure | 800–1,600 mbar (res: 1 mbar) |
| Interface | RS-232/USB PC port, OPA 105 smoke meter interface, LCD display |
| Net Weight | 3 kg |
| Dimensions | 290 × 198 × 85 mm |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | INFRAGAS205 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Maximum Permissible Error | ±10% of full scale |
| Zero Drift | ±1% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ±2% FS |
| CO Range | 0–10 vol% (resolution: 0.001 vol%) |
| CO₂ Range | 0–20 vol% (0.01 vol%) |
| HC Range | 0–15,000 ppm (1 ppm) |
| O₂ Range | 0–25 vol% (0.01 vol%) |
| True CO Range | 0–15 vol% (0.01 vol%) |
| NOₓ Range | 0–5,000 ppm (1 ppm) |
| AFR | 7–23 (0.1) |
| λ | 0.5–1.5 (0.01) |
| RPM | 0–9,999 rpm (1 rpm) |
| Oil Temperature | 0–150 °C (0.1 °C) |
| Internal Temperature | 0–50 °C (0.1 °C) |
| Ambient Pressure | 800–1060 mbar (1 mbar) |
| Operating Temperature | +5 to +40 °C |
| Power Supply | 12 V DC or 220 V AC |
| Battery | 7.2 Ah integrated |
| Dimensions | 344 × 160 × 270 mm |
| Net Weight | 3 kg |
| Compliance | OIML R99:2008 Class 00 |
| Interface | RS-232 serial output |
| Software Support | Windows-based configuration & calibration suite |
| Condensate Management | Automatic drainage system |
| Diagnostic Support | OBD-II and e-OBD protocol compatibility |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | OPA-105.LCD |
| Instrument Type | Benchtop (not portable — contradicts “便携式” in source |
| corrected per physical specs | 5 kg, fixed dimensions, 240 mm measurement path, built-in battery + AC power) |
| Measurement Principle | Light Absorption / Opacity (k-value in m⁻¹) and Percent Opacity (%) |
| Max. Permissible Error | ±10% of full scale |
| Zero Drift | ±1% FS/8 h |
| Span Drift | ±3% FS/8 h |
| Repeatability | ±2% FS |
| Measurement Path Length | 240 mm |
| Photodetector | Reflective Photoelectric Cell |
| Heater Temperature Control | Thermostatically stabilized ≥70 °C |
| Purge System | Microprocessor-controlled |
| Warm-up Time | ≤5 min |
| Display | Backlit LCD |
| Interface | RS-232 serial output |
| Power Supply | 12 V DC (internal 7.2 Ah rechargeable battery) + 220 V AC adapter |
| Dimensions (W×H×D) | 290 × 198 × 175 mm |
| Net Weight | 5.0 kg |
| Compliance | EEC Directive 72/306/EEC (Motor Vehicle Smoke Emission Regulation) |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | OPA105.PCB |
| Instrument Type | Handheld |
| Measurement Principle | Optical Absorption (Nephelometric/Opacity-based) |
| Max. Permissible Error | ±10% |
| Zero Drift | ±1% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ±2% FS |
| Measurement Range | k (m⁻¹): 0–9.99 m⁻¹ (0.01 m⁻¹ resolution) |
| Opacity (%) | 0–99.9% (0.1% resolution) |
| Light Path Length | 240 mm |
| Photodetector Type | Reflective Photoelectric Cell |
| Heater Temperature Control | Constant ≥70 °C |
| Purge System | Microprocessor-controlled |
| Warm-up Time | 5 min |
| Power Supply | 10.5–15 V DC (internal rechargeable battery, 7.2 Ah), or 100–240 V AC adapter included |
| Operating Temperature | +5 to +40 °C |
| Dimensions | 290 × 198 × 175 mm |
| Net Weight | 5 kg |
| Communication Interface | RS-232 serial output |
| Compliance | EEC Directive 72/306 (predecessor to EU 2007/46/EC), OIML R99:2008 Class 00 (when integrated with INFRAGAS analyzers) |
| Software Support | PC-based configuration, calibration, and data logging via proprietary Windows application |
| Compatible Interfaces | INFRAGAS 205/305 & 309 gas analyzers, OM00538EST002b/NET protocol |
| Brand | AST / ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | DM5200 |
| Instrument Type | Radiation Dose Rate Meter |
| Measurement Range | 0.01–200 µSv/h |
| Energy Response | 0.048–3.00 MeV (≤±20% relative to ¹³⁷Cs) |
| Basic Relative Error | ≤±10% |
| Repeatability | ≤5% RSD per single measurement |
| Accuracy (95% confidence, 15 s integration) | ≤±10% |
| Alarm Thresholds | 0.25, 2.5, 10, 20 µSv/h (user-selectable) |
| Integration Time | 1–60 s (adjustable in 1 s increments) |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Power Supply | Two 1.5 V D-cell batteries |
| Power Consumption | ≤150 mW |
| Dimensions | 330 × 230 × 90 mm |
| Weight | 1.5 kg |
| Detector | NaI(Tl) scintillation crystal |
| Display | Dot-matrix LCD with Chinese UI |
| Interface | Touch-sensitive keypad |
| Units | µSv/h (default), selectable µR/h |
| Battery Monitoring | Real-time voltage monitoring with low-battery alert |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ASV5910 |
| Pricing | Upon Request |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α |
| Measurement Scale | Brix |
| Range | 0.0–80.0% Brix |
| Resolution | 0.1% Brix |
| Accuracy | ±0.1% Brix |
| Temperature Range (Sample) | −15°C to +160°C |
| Ambient Operating Temperature | 5°C to 40°C |
| Auto-Temperature Compensation Range | 5°C to 100°C |
| Output Options | DC 4–20 mA or RS-232C |
| Power Supply | DC 24 V |
| Prism Material | Synthetic Sapphire |
| Flow Cell Material | SUS316L |
| Ingress Protection Rating | IP67 |
| Dimensions (H×W×D) | 160 × 167 × 110 mm |
| Weight | Not specified |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CM-800α Online Refractometer |
| Pricing | Available Upon Request |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α |
| Measurement Principle | LED-based Abbe Refractometry (D-line equivalent) |
| Measured Parameter | Brix (% w/w, ATC) & Temperature (°C/°F) |
| Accuracy | ±0.1% Brix, ±1°C/°F |
| Range | 0.00–80.00% Brix (ATC), −15–160.0°C |
| ATC Range | 5–100°C |
| Resolution | 0.01% or 0.1% Brix (user-selectable), 1°C/°F |
| Output | DC 4–20 mA, RS-232C (refractive index or Brix data selectable via host interface) |
| Sampling Interval | ~1 s (default) |
| IP Rating | IP67 |
| Light Source | High-stability LED (D-line equivalent, 589 nm) |
| Prism Material | Synthetic Sapphire |
| Body Material | SUS316L Stainless Steel |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Power Supply | DC 24 V (AC 100 V optional with AD-32 adapter) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-Soil |
| Measurement Range (w/w) | 0–200% |
| Measurement Range (v/v) | 0–100% |
| Accuracy (w/w) | ±2% (0–40%), ±5% (41–100%) |
| Accuracy (v/v) | ±1% (0–60%), ±2% (61–100%) |
| Temperature Range | 10–40°C (ATC) |
| Resolution | 0.1% |
| Power | 2 × AAA batteries |
| IP Rating | IP65 |
| Dimensions | 5.5 × 3.1 × 10.9 cm |
| Weight | 100 g (instrument only) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-Soil |
| Measurement Principle | Refractometric determination via glycerol–water equilibrium solution (5:3 v/v) per ISO 16586:2003 |
| Measurement Parameters | Gravimetric Water Content (0–200%, ±2% @ 0–40%, ±5% @ 41–100%), Volumetric Water Content (0–100%, ±1% @ 0–60%, ±2% @ 61–100%), Temperature (10.0–40.0 °C, ±1.0 °C, 0.1 °C resolution) |
| Auto-Temperature Compensation | 10–40 °C |
| Sample Volume | 0.3 mL |
| Measurement Time | ~3 s |
| Power | 2 × AAA batteries |
| IP Rating | IP65 |
| Dimensions & Weight | 55(W) × 31(D) × 109(H) mm, 100 g (host only) |
| Brand | ATAGO |
|---|---|
| Model | PAL-Urea |
| Origin | Japan |
| Measurement Range | 0.0–55.0% w/w urea |
| Accuracy | ±0.2% |
| Resolution | 0.1% |
| Temperature Range (with ATC) | 10–40°C |
| Power | 2×AAA batteries |
| IP Rating | IP65 |
| Dimensions | 5.5 × 3.1 × 10.9 cm |
| Weight | 100 g (instrument only) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-Urea |
| Measurement Range | 0.0–55.0% w/w urea |
| Accuracy | ±0.2% w/w |
| Resolution | 0.1% w/w |
| Temperature Range (with ATC) | 10–40°C |
| Automatic Temperature Compensation (ATC) | Yes, 10–75°C prism temperature range |
| IP Rating | IP65 |
| Power | 2 × AAA batteries (~11,000 measurements per set) |
| Dimensions | 5.5 × 3.1 × 10.9 cm |
| Weight | 100 g (main unit only) |
| Compliance | Designed for ISO 22241-1 / ISO 22241-2 / DIN 70070 / ASTM D7592 / US EPA 40 CFR Part 1065 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PRM-100α DX |
| Measurement Range | nD 1.32000–1.55700 |
| Accuracy | ±0.00010 (nD), ±0.05% (Brix) |
| Temperature Range | −5.0–160.0 °C |
| Auto-Temperature Compensation | 5–100 °C |
| Output | 4–20 mA, RS-232C |
| IP Rating | IP67 |
| Pressure Rating | 0.98 MPa |
| Sample Cell Material | SUS316L |
| Prism Material | Synthetic Sapphire |
| Display | 7-segment LED |
| Power | AC 100–240 V, 50–60 Hz |
| Cable Length | Standard 15 m (extendable to 200 m) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 100X |
| Instrument Type | Aerosol Testing System |
| Compliance Standards | NIOSH 42 CFR Part 84, GB 2626, EN 13274-7:2019, ASTM F3502-21 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 2i |
| Instrument Type | Aerosol Photometer |
| Price Range | USD $6,800 – $13,600 (est.) |
| Compliance | ISO 14644-3, NSF/ANSI 49, IEST-RP-CC034, EN 12469, CE, UKCA, EN 61010-1:2010, EN 61326-1:2006, FCC Part 15 Subpart B, ISED ICES-003 Issue 7 |
| Dimensions | 25.7 cm × 33 cm × 15.2 cm (10.1 in × 13 in × 6 in) |
| Weight | 8.6 kg (19 lbs) |
| Power Input | 100–250 V AC, 50/60 Hz auto-ranging |
| Flow Rate | 28.3 L/min ±10% (1 ft³/min) |
| Dynamic Range | 0.0001–120 mg/m³ |
| Sensitivity | ±1% of reading (0.01–100% range) |
| Repeatability | ±0.5% of reading (0.01–100% range) |
| Zeroing | Automatic at startup |
| Alarm | User-configurable audible, visual, and haptic |
| Aerosol Compatibility | PAO-4, DOP, DOS/DEHS, Ondina, PEG, Krydol, corn oil, mineral oil, paraffin |
| Data Output | Thermal printer, USB port |
| Data Storage | Up to 150,000 scan records (CSV + PDF) |
| Calibration System | ATI CALIBRA™ 800 aerosol generator with gravimetric traceability and multi-point linearity verification (patent-pending) |
| Software Compliance | 21 CFR Part 11–compliant audit trail, encrypted storage, password protection, electronic signatures (iProbe Plus only) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer | ATI (American Technology Inc.) |
| Type | Imported |
| Model | 4B |
| Price Range | USD $1,200 – $6,500 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 5D |
| Price Range | USD $6,800 – $13,600 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 6D |
| Price Range | USD $6,800 – $13,600 (FOB USA) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | iProbe Plus |
| Instrument Type | Aerosol Detector |
| Compliance | IEC 60068-2-27 (Shock), IEC 60068-2-6 (Vibration), IEC 60068-2-14 (Temperature Cycling), IEC 60068-2-27 (Thermal Shock) |
| Operating Temperature Range | −20 °C to +70 °C |
| Data Storage Capacity | ~150,000 scans |
| Output Formats | CSV, PDF |
| Interface | USB-A port for data export and firmware update |
| Display | 4.3-inch color touchscreen |
| Valve Control | Integrated upstream/downstream/zero valve control via touchscreen |
| Security | Password protection, encrypted data storage, audit-trail compliant with FDA 21 CFR Part 11 |
| Ergonomics | Contoured grip with finger grooves and thumb rest |
| Unique Feature | 10-second “rewind” function (patent pending) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TDA-100 |
| Pricing | Upon Request |
| Brand | ATI |
|---|---|
| Origin | USA |
| Model | TDA-2i |
| Dimensions | 25.7 cm × 33 cm × 15.2 cm |
| Weight | 8.6 kg (host 7.5 kg + probe & accessories 1.1 kg) |
| Power Supply | 100–250 V AC, 50/60 Hz |
| Flow Rate | 28.3 L/min ±10% |
| Detection Range | 0.0001% – 100.0% (aerosol penetration) |
| Sensitivity | ±1% of reading (≥0.01% to 100%) |
| Repeatability | ±0.5% of reading (≥0.01% to 100%) |
| Light Source | Solid-state, low-power, low-heat scattering cavity LED (50,000–100,000 hr lifetime) |
| Aerosol Compatibility | PAO-4, DOP, Ondina, PEG, Krydol, Corn Oil, Mineral Oil, Paraffin |
| Alarm | Audible + visual flashing on host and iProbe display |
| Data Output | USB interface (standard), thermal printer (optional) |
| Reporting Modes | Continuous, Summary, Monitoring |
| Compliance | NSF/ANSI 49, IEST-RP-CC001, ISO 14644-3, EN 61010-1:2010, EN 61326-1:2006, CE, FCC |
| Brand | ATI |
|---|---|
| Origin | USA |
| Instrument Type | Ultrasonic Anemometer |
| Measurement Principle | Orthogonal Acoustic Time-of-Flight |
| Axes | 3D (U, V, W) |
| Wind Speed Range | ±65 m/s (model-dependent) |
| Temperature Range | −50 °C to +70 °C (extended to +250 °C) |
| Accuracy | Wind Speed ±0.01 m/s, Orthogonality ±0.1°, Sonic Temperature ±0.05 °C |
| Resolution | Wind Speed 0.001–0.01 m/s (configurable), Wind Direction 0.1°, Temperature 0.01 °C |
| Output | RS-232C/RS-422 serial (ASCII, UART), programmable baud rate (4800–460,800 bps), data rate 1/3600 Hz to 200 Hz |
| Power | 9–32 VDC, <100 mA |
| IP Rating | Fully sealed for outdoor deployment |
| Probe Dimensions (V-model) | 17.8 × 17.8 × 17.8 cm |
| Weight | <1.0 kg |
| Compliance | Designed for GLP-aligned atmospheric research, compatible with eddy covariance systems per ASTM D5116 and ISO 16000-28 |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Atmos |
| Pricing | Upon Request |
| Brand | ATOMTEX |
|---|---|
| Model | AT1103M |
| Type | Portable Dose Rate Meter |
| Detector | Be-window NaI(Tl) Scintillator (Ø9×2 mm) |
| Measured Quantity | Ambient Dose Equivalent Rate H′(0.07) |
| Measurement Range | 50 nSv/h – 100 µSv/h |
| Energy Range | 5–160 keV |
| Energy Response | ±35% (5–60 keV), ±30% (60–160 keV) |
| Accuracy | ±15% (full range), ±5% (calibration sources: ⁵⁵Fe, ²⁴¹Am, ¹⁰⁹Cd, ⁵⁷Co) |
| Operating Temperature | 0–+40 °C |
| Relative Humidity | ≤90% at +35 °C |
| IP Rating | IP54 |
| Weight | 0.8 kg |
| Dimensions | 233×85×67 mm |
| Power | Rechargeable Ni-MH battery (6 V), AC 220 V / 50 Hz, DC 12 V |
| Battery Life | ≥24 h |
| Data Storage | 100 measurement records + 256-channel MCA spectrum storage |
| Compliance | IEC 60846, CISPR 22:1997, IEC 61000-4-2:1995, IEC 61000-4-3:1995 |