Environmental Monitoring Instruments
Filter
Showing 121–150 of 2384 results
| Brand | ADOS |
|---|---|
| Origin | Germany |
| Model | MWS 903 |
| Sensor Inputs | 8 (2-wire or 3-wire, e.g., LCTR 903) |
| Power Supply | 24 V DC / 200 mA |
| Operating Temperature | −10 to +40 °C |
| Digital Input | 1 (alarm mute) |
| Digital Outputs | up to 12 alarm relays + 1 fault relay + 1 alarm label relay (all floating changeover contacts, 250 V AC / 4 A max) |
| Analog Output | 4–20 mA |
| Communication Interface | RS232 |
| Main Power Options | 230 V AC / 50 Hz |
| Enclosure Dimensions | 240 × 160 × 90 mm |
| Weight | ~2 kg |
| Ingress Protection | IP54 per DIN 40050 |
| Display | 4-line LCD with real-time value, 30-min average, and error messages |
| Keypad | 6-key menu-driven interface |
| Adjustable Alarm Thresholds | 2 independent setpoints per channel (5–100% of full scale) |
| Brand | ADOS |
|---|---|
| Origin | Germany |
| Model | MWS906 |
| Sensor Inputs | 16 (2-wire or 3-wire, e.g., GTR 196) |
| Power Supply | 24 V DC / 2 A |
| Operating Temperature | -10 to +45 °C |
| Enclosure Rating | IP54 per DIN 40050 |
| Dimensions | 390 × 270 × 160 mm |
| Weight | ~5 kg |
| Input/Output | 1 digital input (alarm reset), up to 48 digital outputs (floating changeover contacts, max. 250 V / 4 A), 1 alarm relay, 1 fault relay, 1 service relay, 1 alarm message relay |
| Analog Output | 4–20 mA |
| Communication | RS232 (for printer or PC connection) |
| Main Power Options | 230 V AC, 50 Hz (60 VA max) |
| Gas Measurement Ranges | O₂: 0–25 % vol |
| CO₂ | 0–4 % vol or 0–2000 ppm |
| CO | 0–300 ppm |
| NO₂ | 0–30 ppm |
| H₂S | 0–100 ppm or 0–10,000 ppm |
| NH₃ | 0–1000 ppm |
| H₂ | 0–100 % LEL or 0–1000 ppm |
| HCl | 0–10 ppm or 0–100 ppm |
| N₂O | 0–1 % vol |
| He | 0–100 % vol |
| SF₆ | 0–1000 ppm |
| O₃ | 0–5 ppm |
| ClO₂ | 0–50 ppm |
| CH₄ | 0–100 % LEL |
| C₂H₂ | 0–100 % LEL |
| C₂H₈O (ethanol) | 0–1000 ppm or 0–100 % LEL |
| C₃H₈ | 0–100 % LEL |
| C₄H₁₀ | 0–100 % LEL |
| C₄H₁₀O (diethyl ether) | 0–100 % LEL |
| C₇H₈ (toluene) | 0–100 % LEL or 0–2000 ppm |
| C₈H₁₀ (xylene) | 0–100 % LEL or 0–2000 ppm |
| LPG | 0–100 % LEL |
| R134a | 0–2000 ppm |
| Brand | ADOS |
|---|---|
| Origin | Germany |
| Model | TOX 592 |
| Instrument Type | Single-Channel Electrochemical Gas Transmitter |
| Measurement Principle | Amperometric Electrochemistry |
| Measurable Gases | CO (0–300 ppm), NH₃ (0–200 ppm), NO₂ (0–30 ppm), SO₂ (0–50 ppm), H₂S (0–20 ppm), O₃ (0–5 ppm) |
| Zero Error | <10 ppm CO |
| Baseline Drift | <2% per year |
| Accuracy | ±3% of full scale |
| Linearity | <2% of full scale |
| Response Time (t₉₀) | <60 s |
| Cross-Sensitivity | <2% with integrated filter |
| Output | 0–4–20 mA (2-wire) or LON® (4-wire, 78 kbps) |
| Supply Voltage | 15–30 V DC (max. load 100–500 Ω) |
| Operating Temperature | –10°C to +40°C (with sensor temperature compensation) |
| Humidity Range | 10–99% RH (non-condensing) |
| Sensor Lifetime | ~2 years |
| Sensor Dimensions | Ø80 mm × H80 mm |
| Weight | 600 g |
| Compliance | VDI 2053 (Germany), EN 45544-1/-2, IEC 60079-29-1 (for hazardous area variants, optional) |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA Acetylene |
| Instrument Type | Portable |
| Detection Range | Configurable from ppb to ppm |
| Resolution | <3 ppb/s |
| Response Time | 1 s |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA Eto |
| Pricing | Upon Request |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA LDS |
| Instrument Type | Portable |
| Sensitivity | CH₄ < 1 ppb/s, C₂H₆ < 500 ppt/s |
| Measurement Principle | Mid-Infrared Laser Absorption Spectroscopy |
| Path Length | 13 m in 60 mL sample cell |
| Detection Targets | CH₄, C₂H₆, H₂O (dry mole fraction reported) |
| Ethane/Methane Ratio Accuracy | ±0.02% (e.g., 4.42% ± 0.02%) |
| Drift (Ultra) | ≤2 ppb or 0.1% of reading across full temperature range |
| Operating Environment | 10–40 °C, 10–95% RH (non-condensing) |
| Data Output Rate | 1–2 Hz standard, up to 10 Hz optional |
| GPS Accuracy | High-precision embedded GNSS with magnetic-mount antenna |
| Power Consumption | 15–25 W depending on configuration |
| Dimensions & Weight | Pico (2.75 kg), Ultra Portable (6.5 kg), Strato (2.0 kg) |
| Data Storage | 32 GB internal (expandable) |
| Communication Interfaces | Wi-Fi, RS-232, USB, analog output (optional) |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Model | MIRA N2O/CO |
| Instrument Type | Portable |
| Measured Gases | N₂O, CO |
| Response Time | 1 s |
| Measurement Accuracy | CO < 1 ppb, N₂O < 1 ppb (2 ppb without zeroing) |
| Measurement Range | 1 ppb – 500 ppm |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA N2O CO₂ |
| Instrument Type | Portable |
| Target Gases | N₂O, CO₂, H₂O (simultaneous) |
| Repeatability | 1 ppb |
| Resolution | 200 ppt/s (N₂O), 200 ppb/s (CO₂) |
| Response Time | 1 s |
| Zero Drift | <1 ppb (N₂O), <1 ppm (CO₂) |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 10–95% RH (non-condensing) |
| Measurement Range | N₂O: <2 ppb – 500 ppm |
| CO₂ | <10 ppm – 10% |
| Data Output Rate | 1–10 Hz |
| Power Consumption | 15–25 W (model-dependent) |
| Dimensions & Weight | Model-specific (Pico: 11.5" × 8" × 3.75", 2.75 kg |
| Ultra Portable | 15" × 12" × 7", 6.5 kg |
| Strato | 7.5" × 7.5" × 3.5", 2 kg) |
| Connectivity | Wi-Fi, USB, RS-232, Analog Output (optional) |
| Internal Storage | 32 GB (expandable) |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA OCS |
| Price | Upon Request |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA Propane |
| Instrument Type | Portable |
| Detection Range | Configurable from ppb to ppm |
| Resolution | <3 ppb/s |
| Response Time | 1 s |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Model | MIRA Ultra |
| Detection Principle | Multi-pass Absorption Cell Coupled with Solid-State Mid-Infrared Laser Spectroscopy |
| Precision | CH₄: <1 ppb/s, N₂O: <200 ppt/s, CO₂: <200 ppb/s |
| Measurement Ranges | CH₄: 10 ppb – 10,000 ppm |
| N₂O | <2 ppb – 500 ppm |
| CO₂ | <10 ppm – 10% |
| H₂O | Full-range humidity compensation |
| Optical Path Length | 15 m in 60 mL cell volume |
| Data Output Rate | 1–10 Hz (configurable) |
| Dimensions | 45.7 × 38.1 × 17.8 cm (W×D×H) |
| Weight | 8.5 kg |
| Power Consumption | 25 W |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 10–95% RH (non-condensing) |
| Internal Battery Life | 6 hours |
| Communication Interfaces | Wi-Fi, USB, RS-232, Analog Output (optional) |
| Onboard Storage | 32 GB (expandable) |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA VOC |
| Pricing | Upon Request |
| Principle | Photoacoustic Spectroscopy (PAS) with Mid-Infrared Laser Absorption |
| Measurement Range | 1 ppb to 500 ppm |
| Resolution | 1 ppb |
| Repeatability | ±2% of reading |
| Sampling Method | Tunable Mid-IR Laser Absorption Spectroscopy |
| Response Time | <1 s (T90) |
| Operating Temperature | 10–40 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model Series | A660 / A670 / A680 |
| Price Range | USD 75,000 – 140,000 |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A660-8800 |
| Pricing | Upon Request |
| Spectral Range | 350–2500 nm |
| Integrated Camera Resolution | 26 MP |
| Payload Weight | <700 g |
| Control Architecture | Custom BRDF Flight Module + Ground Station Software Suite |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Aero LF |
| Price | USD 81,200 (approx.) |
| Weight | 1.0 kg (300 MHz antenna), 1.2 kg (150 MHz antenna), 1.4 kg (75 MHz antenna) |
| Operating Temperature | −20 °C to +60 °C |
| Dynamic Range | 0–168 dB |
| Sampling Rate | up to 1,280,000 samples per second |
| Scan Rate | up to 2,500 scans per second (configuration-dependent) |
| Penetration Depth | 10–12 m (soil-dependent) |
| Data Resolution | 32-bit raw digital output |
| Real-time Terrain Following Capability | Yes (with optional altimeter integration) |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Aero1000 |
| Price | USD 79,500 (FOB Beijing) |
| Dimensions & Weight | Airborne Configuration: 31 × 19 × 15 cm, 1.7 kg |
| Ground Configuration | 52 × 43 × 21 cm, 7.0 kg |
| Operating Temperature | −20 °C to +60 °C |
| Dynamic Range | 0–84 dB |
| Sampling Rate | 25,600 samples/s |
| Depth Penetration | Up to 2 m (soil-dependent) |
| ADC Resolution | 16-bit |
| Trace Sampling Density | 512 samples/trace |
| Real-Time Terrain Following Capability | Yes (with integrated altimeter, 2 cm vertical accuracy at 1 m AGL) |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Aero500 |
| Price | USD 76,500 (FOB Beijing) |
| Dimensions & Weight | Airborne Configuration — 41 × 31 × 16 cm, 2.1 kg |
| Operating Temperature | −20 °C to +60 °C |
| Dynamic Range | 0–84 dB |
| Sampling Rate | 25,600 samples/s |
| Depth Range (Typical) | 4 m @ 100 ns (in homogeneous low-conductivity media, e.g., dry sand or ice) |
| ADC Resolution | 16-bit |
| Trace Density | 512 samples/trace |
| Real-Time Terrain Following Capability | Yes (with integrated altimeter and AGS-2 cm vertical accuracy at 1 m AGL) |
| Brand | Aero |
|---|---|
| Origin | Germany |
| Model | AL2021 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Target | Hydrogen Peroxide (H₂O₂) and Organic Peroxides |
| Linear Range | 100 ppt–3 ppm (gas phase) |
| Detection Limit | 100 ppt (gas) |
| Response Time (10–90%) | 90 s |
| System Delay | ~300 s |
| Dimensions | 50 cm × 49 cm × 13 cm |
| Weight | 20 kg |
| Power Supply | 240 VAC, 60 Hz, 110 W |
| Communication Interface | RS-232 |
| Interference Tolerance | O₃ < 1:3500 |
| NO < 1 | 8000 |
| Automation | Fully microprocessor-controlled with integrated gas-stripping and precision peristaltic pumping |
| Calibration | Auto-calibration via internal H₂O₂ source or liquid standard |
| Brand | AERO |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ARIEL |
| Frequency | 1.413 GHz (L-Band) |
| Bandwidth | 20 MHz |
| Radiometric Accuracy | ±0.7 K at 1 Hz integration time |
| Sampling Rate | Up to 10 Hz |
| Polarization | Dual (H + V) |
| Beamwidth | 37° (Ground & UAV), 22° (Airborne) |
| Radiometric Resolution | 0.02 K |
| Radiometric Precision | ±0.2 K |
| Coordinate System | WGS84 (EPSG:4326) |
| Spatial Resolution (GSD) | 1 m |
| Power Input | 12 V DC |
| Electronics Current Draw | 0.5 A |
| Heater Current | 1 A (Ground/UAV), 4 A (Airborne) |
| Interface | Ethernet, Web-based Configuration UI |
| Data Output Format | Brightness Temperature (TB) in NetCDF/GeoTIFF |
| Optional Processing | TB-to-Soil Moisture Inversion Software |
| Dimensions | 400 × 300 × 250 mm (Ground), Ø410 mm (Airborne) |
| Weight | 6 kg (Ground), 2.8 kg (UAV), 15 kg (Airborne) |
| Platform Compatibility | Fixed-wing aircraft, multirotor & VTOL UAVs, ground vehicles, sleds |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | AZCW |
| Price Range | USD 70,000 – 345,000 |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | D052 |
| Price | USD 71,400 (FOB) |
| Net Weight / Total Weight | 460 g / 2.7 kg |
| Operating Frequencies | 50 kHz / 200 kHz dual-band |
| Depth Measurement Range | 1.0–200 m (50 kHz), 0.5–200 m (200 kHz) |
| Beam Width | 27° (50 kHz) / 7° (200 kHz) |
| Temperature Sensor Resolution | 0.1°C |
| Tilt Sensor | Integrated dual-axis (roll & pitch), ±90° range, 0.1° resolution |
| Data Output Rate | Up to 20 Hz (configurable) |
| Interface | RS-232 / RS-422 / Ethernet (optional) |
| IP Rating | IP68 (submersible to 200 m) |
| Compliance | IEC 60945, EN 62288, ISO 17662-2 |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ECT400 |
| Price | USD 69,500 (FOB Beijing) |
| Net Weight | 275 g (transducer only), 1.6 kg (full system with housing & electronics) |
| Operating Temperature Range | −10 °C to +50 °C |
| Transducer Frequency | 450 kHz |
| Depth Measurement Range | 0.15–100 m (customizable up to 1000 m) |
| Depth Resolution | 1 mm |
| Depth Accuracy | ±0.2% of full scale |
| Temperature Sensor Resolution | 0.1 °C |
| Tilt Sensor Resolution | 0.1° |
| GPS Integration | NMEA 0183/RS232 output with automatic timestamping and georeferencing |
| Response Time (depth) | <50 ms |
| Backscatter Sensitivity | −80 dB to +20 dB dynamic range |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL2021 |
| Detection Target | Trace H₂O₂ in Gaseous and Aqueous Matrices |
| Detection Limit | <100 ppt (gas), <100 ng/L (liquid, ≈3×10⁻⁹ mol/L) |
| Linear Range | 100 ppt–3 ppm (gas), 100 ng/L–3 mg/L (liquid) |
| Response Time (10–90%) | 90 s |
| System Delay | ~300 s |
| Calibration | Auto-calibration via integrated liquid H₂O₂ standard or internal gaseous H₂O₂ source |
| Dimensions | 50 cm × 49 cm × 13 cm |
| Weight | 20 kg |
| Power Supply | 240 VAC, 60 Hz, 110 W |
| Interface | RS-232 |
| Interference Tolerance | O₃ < 1:3500, NO < 1:8000 |
| Sample Handling | Integrated gas stripping, dual-channel configuration, digitally controlled precision peristaltic pump |
| Brand | Aero Laser |
|---|---|
| Origin | Italy |
| Model | AL2021SC |
| Detection Principle | Enzyme-catalyzed fluorometric assay (horseradish peroxidase or catalase-based) |
| Linear Range | 0.1–2000 ppb (gas phase), 150 ng/L–5 mg/L (liquid phase) |
| LOD | <100 ppt (gas), <150 ng/L (liquid), <2×10⁻⁹ mol (liquid) |
| Response Time (10–90%) | 90 s |
| System Delay | ~300 s |
| Noise Level | ≤2% FS |
| Sample Temp. Range | >0 °C to +120 °C |
| Calibration | Auto-zero + semi-automated liquid standard calibration (optional) |
| Interface | Touchscreen GUI + remote operation via Android tablet or PC |
| Connectivity | LAN, RS232 |
| Data Logging | Internal memory + USB export |
| Software | SOL-based graphical data recording & visualization |
| Dimensions | 45 cm × 15 cm × 56 cm (19″ rack-mountable) |
| Weight | 15 kg |
| Power | 110/220 VAC, 110 W |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL4021 |
| Principle | Photometric Detection via Hantzsch Reaction |
| Measurement Range | 0.1 ppb – 3000 ppb (gas phase), 150 ng/L – 5 mg/L (aqueous phase) |
| Resolution | 0.1 ppb |
| Repeatability | <3% |
| Sampling Method | Pump-aspirated |
| Response Time | 90 s (10–90%) |
| Operating Temperature | 0 °C – 120 °C |
| Humidity Range | 15–95% RH |
| Detection Limit | <100 ppt (gas), <150 ng/L (liquid) |
| Calibration Options | Automated gas-phase calibration (integrated permeation tube generator), semi-automated liquid-phase standard injection |
| Data Storage | USB flash drive (8 GB) |
| Interface | RS232 |
| Dimensions (W×H×D) | 45 × 15 × 56 cm |
| Mounting | 19″ rack-compatible |
| Power Supply | 110/220 VAC, 110 W (24 VDC optional) |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL5001 |
| Detection Principle | Vacuum Ultraviolet Fluorescence (VUV) at 150 nm |
| Detection Limit | <2.0 ppb (1 s integration), <0.8 ppb (10 s integration) |
| Response Time (10–90%) | 2 s |
| Linear Range | 0–100 ppm (pulse counting mode) |
| Pump Type | Diaphragm vacuum pump |
| Interface | RS232 |
| Power Supply | 110/220 VAC or 24 VDC |
| Weight | 22 kg |
| Automation | Fully automated measurement and calibration |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL5001 |
| Detection Principle | Vacuum Ultraviolet Fluorescence (VUV-F) at 150 nm |
| Detection Limit | <0.8 ppb (10 s integration) |
| Linear Range | 0–100 ppm (pulse counting mode) |
| Response Time (10–90%) | 2 s |
| Pump Type | Diaphragm Vacuum Pump |
| Interface | RS232 |
| Power Supply | 110/220 VAC or 24 VDC |
| Weight | 22 kg |
| Automation | Fully Automated Zero/Span Calibration |
| Application Scope | Ultra-trace CO monitoring in ambient air, cleanrooms, high-purity specialty gas streams, and remote atmospheric research stations |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MPL-1400U |
| Pricing | Available Upon Request |
| Brand | AERO |
|---|---|
| Platform Type | VTOL UAV (A660 hexacopter or AZCW fixed-wing) |
| Sensor Compatibility | Visible RGB, Snapshot Hyperspectral (V185/X20P), Research-Grade Multispectral (K6), Dual-Camera Thermal IR (Pro Sc), High-Accuracy LiDAR (AZ-LiDAR) |
| Data Output | Radiometrically Calibrated Reflectance & Temperature Cubes, Point Clouds, Canopy Height Models, NDVI/EVI/NDRE/TCI Indices, Biomass & LAI Estimates |
| Compliance | ASTM E2924-22 (Standard Guide for Remote Sensing of Vegetation), ISO 17937:2021 (Spectral Reflectance Measurement of Vegetation), FAO CropWatch Protocols, GLP-aligned Metadata Archiving |
| Software Integration | AERO-PhenoSuite v3.2 (with FDA 21 CFR Part 11–compliant audit trail, ISO/IEC 17025 traceable calibration logs, and USDA-NRCS-compatible georeferencing) |
| Brand | Aerodyne |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CAPS PMex |
| Instrument Principle | Cavity Attenuated Phase Shift Spectroscopy (CAPS) |
| Product Type | Online Continuous Monitor |
| Response Time | <2 s |
| Repeatability | CO, CO₂, CH₄, C₂H₄, HCHO, CHOOH, COS, SO₂, NO, N₂O, NO₂, NH₃, HONO, HNO₃, ¹³C-CO₂, ¹⁸O-CO₂, ¹⁷O-CO₂, HOD, ¹⁵N¹⁴N¹⁶O (δ¹⁵Nα), ¹⁴N¹⁵N¹⁶O (δ¹⁵Nβ) |
| Wavelength Options | 405 nm, 450 nm, 525 nm, 630 nm, 660 nm, 780 nm (up to 4 simultaneously selectable) |
| Linear Range | 0–4000 Mm⁻¹ |
| Sensitivity | 2.5 Mm⁻¹ (1 s), 0.25 Mm⁻¹ (60 s) |
| Sample Flow Rate | 0.85 L/min per cavity |
| Operating Pressure | Ambient |
| Materials in Contact with Sample | Conductive polyurethane, stainless steel, conductive silicone, aluminum |
| Data Output | RS-232, USB, Ethernet |
| Onboard Storage | 5 years of data |
| Dimensions | 61 cm × 43 cm × 31 cm |
| Weight | 15 kg |
| Power | <100 W, 100–250 VAC (50–60 Hz) |