Environmental Monitoring Instruments
Filter
Showing 2131–2160 of 2616 results
| Brand | Sabio |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 2030 |
| Price | Upon Request |
| Measurement Principle | UV Absorption at 254 nm (Beer–Lambert Law) |
| Range Options | 0–100 / 0–200 / 0–500 ppb or 0–1 / 0–2 ppm |
| Detection Limit | 1 ppb |
| Zero Noise | 0.6 ppb RMS |
| Zero Drift | <1.0 ppb/24 hr, <2.0 ppb/7 days |
| Span Drift | <1% per month |
| Response Time | 20 s (10 s delay) |
| Accuracy | ±1 ppb |
| Linearity | ±1% of full scale |
| Sample Flow Rate | 1 L/min |
| Operating Temperature | 5–45 °C |
| Power Supply | 98–132 VAC / 196–264 VAC, 50/60 Hz |
| Analog Outputs | Four independent, scalable (0.1 V / 1 V / 2 V / 5 V / 10 V) |
| Digital Interfaces | USB, RS-232/RS-485 (DB-9) |
| Display | Color LCD with touchscreen, front-panel keys, external keyboard/mouse support |
| Data Storage | Internal logging with timestamped records |
| Built-in Ozone Generator | 0.05–1.5 ppm @ 5 SLM, ±2% of setpoint or ±3 ppb @ 5 SLM |
| Auto Zero Compensation | Yes |
| Temperature & Pressure Compensation | Yes |
| Dimensions | 15.6 cm H × 36.4 cm W × 31.6 cm D |
| Weight | 9.1 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SabreASC |
| Pricing | Upon Request |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AT-DX100 |
| Instrument Type | Portable |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | 0–70 °C |
| Reagent Storage & Usage Temperature | 0–55 °C |
| Coefficient of Variation (CV) | ≤5% |
| Batch Capacity | 1–10 samples per run |
| Detection Time | ≤5 minutes |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Analyzer |
| Principle | Infrared Spectrophotometry (Fourier-transform-free, Dispersive NIR with Fixed-Wavelength Detection at 2930, 2960, and 3030 cm⁻¹) |
| Measurement Range | 0.002–64,000 mg/L |
| Detection Limit | < 0.04 mg/L |
| Accuracy | ±2% (relative error, certified reference materials) |
| Resolution | 0.002 mg/L |
| Analysis Cycle Time | 30 seconds per sample (including extraction solvent introduction, cell filling, and spectral acquisition) |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AT-H300 |
| Instrument Type | Laboratory |
| Measurement Principle | Infrared Spectrophotometry (Fourier-transform-free, dual-beam fixed-wavelength absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 3030 cm⁻¹) |
| Measurement Range | 0.01–64,000 mg/L |
| Detection Limit | 0.01 mg/L |
| Accuracy | ±0.01 mg/L |
| Resolution | 0.004 mg/L |
| Sample Throughput | 7–10 minutes per sample |
| Compliance | HJ 637–2018, HJ 1051–2019, HJ 1077–2019, JJG 1153–2023 |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AT-Z300 |
| Instrument Type | Laboratory-Based |
| Measurement Principle | Ultraviolet Spectrophotometry (UV-Vis) |
| Measurement Range | 0.002–64,000 mg/L |
| Limit of Detection (LOD) | < 0.01 mg/L |
| Accuracy | ±0.2 mg/L |
| Resolution | < 0.004 mg/L |
| Analysis Time per Sample | 7–12 minutes |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | CCLJP-100A |
| Pricing | Available Upon Request |
| Measurement Principle | Optical Light Scattering (90° Detection) |
| Sampling Flow Rate | 1 L/min |
| Particle Size Range | 0.18–20 µm |
| Particle Counting Range | 0–20,000 particles/cm³ |
| Number of Size Channels | 64 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Oxidation–Spectrophotometric Method |
| Measurement Range | 0–3500 mg/L COD<sub>Cr</sub> (expandable) |
| Repeatability | ±3% RSD |
| Limit of Detection | 5 mg/L COD<sub>Cr</sub> |
| Analysis Cycle Time | 60–360 min per measurement |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | XHAQSP-709E |
| Instrument Type | Online |
| Detection Principle | Multi-sensor Array (Electrochemical, Metal Oxide Semiconductor, Photoionization Detector PID) |
| Sampling Method | Negative-pressure Vacuum Sampling |
| Sample Container | Polyester Gas Sampling Bags (Low Adsorption, Low Permeability, Low VOC Background) |
| Deployment Flexibility | Ambient Air or Integrated Monitor Inlet Sampling |
| Bag Capacity & Quantity | Configurable (Standard Options: 1–6 bags × 0.5–3 L each) |
| Compliance Context | Designed to support GB/T 14675–2023, GB/T 14678–1993, HJ 905–2017, and ISO 16000-6 for odor sample integrity and traceability |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHPM2000E |
| Measurement Principle | Beta-ray attenuation with dynamic heating system |
| Measured Parameter | PM₂.₅ mass concentration |
| Measurement Range | 0–0.1, 0.2, 1, 2, 5, or 10 mg/m³ (user-selectable full-scale ranges) |
| Measurement Cycle | 30 min to 60 min (configurable) |
| Sampling Flow Rate | 16.7 L/min ±2.5% |
| Limit of Detection (24-hr avg) | 5 µg/m³ |
| Compliance | Certified per Chinese EPA requirements for radioactive source management, HJ 653–2013, HJ 93–2013, and GB/T 34672–2017 |
| Regulatory Approvals | CEPAA Environmental Product Certification, CNEMC Calibration & Performance Verification Report, CIPAC Technical Appraisal Certificate for PM₂.₅ Separation Inlet |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ST-T2 |
| Detection Range | 3.6 kg (instrument weight) |
| Operating System | Android (ARM Cortex-A7, RK3288, Quad-core, 1.88 GHz) |
| Display | 7-inch TFT capacitive touchscreen (1024 × 600) |
| Optical System | 4-channel fixed-wavelength cold LED光源 (680±2 nm red, 420±2 nm blue, 510±2 nm green, 590±4 nm orange) |
| Photometric Accuracy | ±0.001 Abs (2 h drift), repeatability ≤0.03% (K₂Cr₂O₇) |
| pH Measurement | 1–14, resolution 0.01, accuracy ±0.1 |
| EC/Soil Salinity | 0.01–1.00%, relative error ±5% |
| Moisture Measurement | 0–100% w/w, error <0.5% |
| Data Connectivity | Wi-Fi, 4G, GPRS, Ethernet, USB |
| Environmental Rating | IP65 |
| Battery | Rechargeable Li-ion, >10 h continuous operation |
| Dimensions | 42 × 31 × 15 cm |
| Net Weight | 3.6 kg |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-TN2 |
| Price | USD 4,200 (FOB) |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-WSYPF |
| Price | USD 820 (FOB) |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | MP523-01 |
| Instrument Type | Benchtop |
| Measurement Range | pH: −2.000–19.999 |
| Ion Concentration | 0.00–14.00 pX (equivalent to 0.01 mg/L–1000 mg/L depending on ion valence and selectivity) |
| Temperature | −10–110 °C |
| Detection Limit | 0.01 mg/L (typical for monovalent ions) |
| Response Time | ≤60 s (for ion concentration stabilization) |
| Accuracy | pH: ±0.002 pH |
| Ion | ±0.5% of reading (monovalent), ±1.0% of reading (divalent) |
| Temperature | ±0.4 °C |
| Temperature Compensation | Automatic, 0–100 °C (pH), 0–60 °C (ion) |
| Data Storage | 900 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture with audit-trail-capable data logging |
| Brand | SANXIN Peri |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | WS200 |
| Quotation | Upon Request |
| Net Weight | ~500 g (portable) |
| Operating Temperature | 0–80 °C (fluoride measurement) |
| Power Supply | 4 × 1.5 V AA batteries or optional external DC adapter |
| Repeatability | pH ≤ ±0.01 pH |
| Response Time | ≤5 s |
| Accuracy | pH ±0.01 pH |
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | YD300 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measurement Principle | Spectrophotometric Method (Colorimetric Determination via Calcium/Magnesium Complex Formation) |
| Measured Parameter | Total Calcium and Magnesium Ion Concentration (as Total Hardness) |
| Measurement Range | 0–10 mmol/L (as CaCO₃ equivalent) |
| Repeatability | ≤ ±5% FS |
| IP Rating | IP67 |
| Display | Backlit LCD with Blue Illumination |
| Temperature Compensation | Automatic, 5–50 °C |
| Temperature Range | 0–60.0 °C (±0.5 °C accuracy) |
| Resolution | 0.01 / 0.1 unit (user-selectable per hardness scale) |
| Units Supported | mmol/L, mg/L (CaCO₃), mg/L (CaO), mmol/L (Boiler), mg/L (Ca), °fH (French), °dH (German), °eH (English) |
| Calibration Solutions | B1, B2, B3 standard kits included |
| Power | Battery-operated (low-voltage indicator) |
| Auto Functions | Auto-calibration, auto-zero, auto-hold, auto-shutdown, real-time temperature compensation |
| Brand | Saprete |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HS-6A |
| Price Range | USD 7,000–10,000 (FOB) |
| Instrument Type | Laboratory Benchtop System |
| Sample Capacity | 6 positions |
| Flow Control | Motor-driven digital mass flow control (not manual rotameter) |
| Acid Addition | Programmable per-sample automated reagent injection |
| Operation Mode | Fully automated sequence-controlled workflow |
| Enclosure | Sealed vapor-tight chamber |
| Heating Method | Integrated water bath with PID temperature regulation |
| Interface | 7-inch capacitive touchscreen HMI |
| Brand | SARAD |
|---|---|
| Origin | Germany |
| Model | RTM 1688-2 |
| Sampling Method | Active sampling |
| Measurement Range | 0–10 MBq/m³ |
| Detection Limit | Not specified (contextually implied as sub-10 Bq/m³ in slow mode) |
| Response Time | 95% in 12 min (fast mode) |
| Flow Rate | 0.30 L/min |
| Detector Type | Integrated semiconductor alpha spectrometer with electrostatic collection chamber |
| Sensitivity | 3 cpm/(Bq/m³) (fast mode) / 7 cpm/(Bq/m³) (slow mode) |
| Chamber Volume | ~250 mL |
| Humidity Independence | Yes, no desiccant required |
| Data Storage | 2047 measurement records |
| Compliance | Designed for ISO 11665 series, ICRP recommendations, and EPA/WHO radon assessment protocols |
| Brand | SARAD |
|---|---|
| Origin | Germany |
| Model | RTM2200 |
| Sampling Method | Active |
| Measurement Range | 0–10,000,000 Bq/m³ |
| Minimum Detectable Concentration | 1 Bq/m³ |
| Response Time | 12 min (Po-214 excluded) / 120 min (Po-214 included) |
| Detector Type | Silicon semiconductor alpha spectrometer with deep ion implantation |
| Sensitivity | 3.2 cpm/(kBq/m³) (Po-214 excluded) / 7 cpm/(kBq/m³) (Po-214 included) |
| Chamber Volume | ~135 mL |
| Built-in Pump Flow Rate | 300–800 mL/min |
| Operating Interface | 240 × 128 pixel graphical touchscreen |
| Data Storage | SD card with GPS tagging (optional) |
| Communication Interfaces | USB, RS232 (supports GSM modem, ZigBee, or Wi-Fi adapter upgrade) |
| Dimensions | 235 × 140 × 255 mm |
| Environmental Sensors (standard) | Air temperature, relative humidity, flow rate, barometric pressure, battery status |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | 16757 |
| Flow Rates | 30, 40, 50, and 125 L/min (4 adjustable settings) |
| Flow Measurement Range | 1–16 m³/h, ±2% accuracy |
| Battery Runtime | ~4.5 hours at 50 L/min |
| Operating Temperature | Ambient |
| Operating Humidity | ≤85% RH (non-condensing) |
| Sampling Principle | Membrane filtration with gelatin or pre-filled Bactair™ agar media |
| Language Options | English, French, German, Italian, Spanish |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | 16746-01--COM |
| Sampling Principle | Gel Membrane Filtration |
| Flow Rate Range | 2.0–8.0 m³/h (adjustable) |
| Flow Measurement Accuracy | ±2% (1–16 m³/h) |
| Sampling Duration | 1–99 minutes (programmable), continuous monitoring mode up to 8 hours |
| Operating Temperature | Ambient |
| Operating Relative Humidity | ≤85% RH |
| Sterilization Compatibility | VHP (Vaporized Hydrogen Peroxide) resistant |
| Filter Pore Size | 0.2 µm |
| Microbial Retention Efficiency | ≥99.9% for bacteria and viruses |
| Maximum Cable Length Between Command Unit and Sampling Head | 30 m |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SCG-N |
| Price Range | USD 14,000–42,000 (FOB) |
| Instrument Type | Soil Moisture / Water Potential Analyzer |
| CO₂ Measurement Principle | NDIR (Non-Dispersive Infrared), Single-Beam Dual-Wavelength |
| Standard Depth Layers | 3 |
| Data Logger | 16-Channel (expandable to 32) |
| Power Supply | Rechargeable Li-ion Battery or Solar Panel |
| Wireless Connectivity | 4G LTE Full-Band Module (backward-compatible with EDGE/GPRS) |
| Compliance | Designed for GLP-aligned field research |
| Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MODEL 9001 |
| Application | Real-time in-situ chlorophyll a monitoring in surface water bodies |
| Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MODEL 9880 |
| Instrument Type | Online Analyzer |
| Biological Sensing Element | Electroactive Bacteria (Exoelectrogens) |
| Repeatability | ±30% |
| Detection Principle | Microbial Fuel Cell (MFC)-Based Current Response to Toxic/Nutrient Perturbations |
| Communication Interfaces | RS485, Modbus TCP, 4–20 mA Output, Optional 3G/4G LTE |
| Display Interface | Chinese-Language Touchscreen HMI |
| Compliance Framework | Designed for ISO 11348-3 and ASTM D5664 alignment in operational context |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BM-6000 |
| Instrument Type | Online Analyzer |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Temperature Control Accuracy | ≤ ±1 °C |
| Batch Capacity | 10 samples per cycle |
| Measurement Time | 5 min (default assay duration) |
| Measurement Principle | Dual-optical-path bioluminescence inhibition assay |
| Compliance Standard | ISO 11348-3:2007 & GB/T 15441–1995 |
| Photometric Range | 0–200% relative light units (RLU) |
| Reproducibility (CV) | ≤10% |
| Pure Water Light Loss | ±3% |
| Sample Injection Precision | ≤2% (syringe-based volumetric delivery) |
| Data Storage | ≥2 years at 1-hour measurement interval |
| Communication Interface | RS-232 / RS-485 (Modbus RTU protocol) |
| Analog Output | 4–20 mA DC (≤300 Ω load) |
| Display | 12.1″ capacitive touchscreen LCD |
| Dimensions (W×D×H) | 560 × 430 × 1600 mm |
| Weight | ~20 kg |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CCZ-20 |
| Pricing | Available Upon Request |
| Compliance | GB/T 3836.18–2017 (Intrinsically Safe Electrical Systems for Explosive Atmospheres), GB/T 20964–2007 (Dust Samplers), Q/HHD 0103–2016 (Enterprise Standard), BMRC Respirable Dust Separation Curve Conformance |
| Protection Rating | IP54 |
| Construction | High-strength ABS engineering plastic housing with anti-humidity, anti-dust, and anti-static treatment |
| Flow Stability | Low pulsation, high load capacity, stable volumetric flow |
| Operational Interface | PVC membrane switch panel |
| Certification | MA (Mine Safety Approval) and Explosion-Proof Verification Certificate |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DP8600 |
| Measurement Principle | Full-Spectrum Absorption Spectrophotometry |
| Wavelength Range | 190–1100 nm |
| Measurable Parameters | COD, Ammonia Nitrogen, Nitrate Nitrogen, Nitrite Nitrogen, Total Nitrogen, Total Phosphorus |
| Sample Holders | Cuvette (standard), 16 mm and 25 mm test tubes |
| Light Sources | Imported Deuterium Lamp (UV), Tungsten-Halogen Lamp (Vis) |
| Detector | Imported Photodiode Array |
| Display | 7-inch TFT color touchscreen (bilingual: English/Chinese) |
| Optical Functions | Photometric Mode, Quantitative Analysis, Standard Curve Construction, Kinetic Scanning, Full-Spectrum Scan |
| Data Storage | USB flash drive support |
| Custom Curve Capability | Yes |
| Optional Accessories | 5 cm and 10 cm sample holders |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | EDXP3600 |
| Price | Upon Request |
| Excitation Source | 50 kV / 200 µA Ag-target micro-focus X-ray tube, end-window configuration, ≤4 W power match |
| Detector | 25 mm² fast Silicon Drift Detector (SDD), 0.3 mil Be window, energy resolution ≤125 eV (Mn Kα), Peltier-cooled |
| MCA | 4096-channel digital pulse processor |
| Elemental Range | Na (11) to U (92) |
| Analysis Modes | Alloy, RoHS, Soil, Water |
| Soil LODs (SiO₂ matrix) | Pb <5 mg/kg, As <3 mg/kg, Cr <15 mg/kg, Cu <10 mg/kg, Zn <2 mg/kg, Ni <5 mg/kg, Mn <10 mg/kg, Hg <1 mg/kg, Cd <3 mg/kg |
| Water LODs (aqueous matrix) | Pb <1 mg/L, As <0.5 mg/L, Cr <2 mg/L, Cu <1 mg/L, Zn <2 mg/L, Ni <1 mg/L, Mn <2 mg/L, Hg <1 mg/L, Cd <1 mg/L |
| Quantification Time | 3–60 s (user-adjustable) |
| Repeatability | RSD <4% (for major elements in homogeneous alloys) |
| Collimation & Filters | 6 interchangeable filters + multiple collimators → 18 automatic combinations |
| Display | 5.5″ high-brightness capacitive touchscreen LCD |
| Processor | Intel quad-core @ 1.33 GHz |
| Memory | 2 GB RAM, 32 GB internal storage (expandable via microSD) |
| Connectivity | Wi-Fi 802.11 b/g/n, Bluetooth 4.0, USB 2.0, GPS module |
| Safety | Beam-on detection sensor, auto X-ray cutoff during air measurement |
| Weight | 1.5 kg (with battery) |
| Operating Environment | –20 °C to +50 °C, RH <90% non-condensing |
| Power | Rechargeable Li-ion, 6700 mAh, >6 h typical operation |
| Data Output | Excel, BMP, PDF reports |
| Compliance | Meets IEC 62471 (LED/X-ray safety), ISO 12885 (XRF safety guidance), and supports GLP/GMP audit trail requirements via timestamped, user-logged data export |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | FD216 |
| Sampling Method | Active Pump-Driven Sampling |
| Measurement Range (Air Radon) | 3–100,000 Bq/m³ |
| Minimum Detectable Activity | 3 Bq/m³ |
| Response Time (Air) | 30 min |
| Detector | ZnS(Ag) Scintillation Screen Coupled with Photomultiplier Tube (PMT) |
| Sensitivity | ≥0.68 cpm/(Bq·m⁻³) |
| Background Count Rate | ≤0.3 cpm |
| Repeatability Error | ≤5% (at 2000 Bq/m³, 65% RH, 25°C) |
| Stability | ≤10% drift over 8 h |
| Power Supply | Rechargeable Li-ion Battery (30 h continuous operation) or AC Adapter |
| Operating Temperature | −10 to +40 °C |
| Relative Humidity | ≤90% at +40 °C |
| Data Storage Capacity | 2000 records |
| Display | LCD |
| Dimensions | 330 × 210 × 170 mm |
| Weight | 5 kg (main unit) |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | MP5300 |
| Pricing | Available Upon Request |