Environmental Test Chamber
Filter
Showing 661–690 of 2010 results
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,000 (FOB) |
| Brand | OEM / Custom Manufacturer |
|---|---|
| Origin | China (Manufactured in Wuhan) |
| Supplier Type | Authorized Distributor |
| Import Status | Imported Components |
| Price | USD 4,050 (FOB Wuhan) |
| Temperature Range | 110°C / 132°C (saturated steam) |
| Humidity Range | 100% RH (saturation) |
| Pressure Range | 0.5–2.0 kg/cm² (max safety capacity: 3.5 kg/cm²) |
| Test Duration | 0–999 h (adjustable) |
| Temperature Uniformity | ±2.0°C |
| Heating Rate | RT to 132°C in ≤35 min (at control point) |
| Pressurization Rate | 0.0 to 2.0 kg/cm² in ≤40 min (at control point) |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Controller | Microprocessor-based PID with SSR output |
| Compliance | ASTM F1876, IEC 60068-2-66, JIS C 60068-2-66, ISO 16750-4, MIL-STD-883 Method 1008.8, UL 1577, NACE TM0177, CNS 12403 |
| Brand | OEM / Custom Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 14,200 (FOB) |
| Internal Chamber Dimensions | Ø300 × 450 mm (D × H) |
| External Dimensions | 660 × 950 × 600 mm (W × H × D) |
| Internal Material | SUS316 Stainless Steel or Epoxy-Coated Steel |
| Temperature Resolution | 0.1 °C |
| Pressure Control Range | 0–4 kg/cm² (0–392 kPa) |
| Operating Pressure Range | 1.0–2.5 kg/cm² (98–245 kPa) |
| Saturation Steam Temperature Range | Up to 143 °C at 2.5 kg/cm² |
| Pressure Accuracy | ±0.2–1.5 kg/cm² |
| Heating Method | Insulated High-Voltage Nichrome Heater with PID + SSR Control |
| Air Circulation | Natural Convection of Saturated Steam |
| Compliance | ASTM B117, IEC 60068-2-66, JIS C 60068-2-66, MIL-STD-202G, ISO 9001, UL 61010-1, NACE TM0177 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | +105.0°C to +142.9°C |
| Humidity Range | 75–100% RH |
| Temperature Stability | ±0.5°C |
| Humidity Stability | ±3% RH |
| Temperature Uniformity | ±1.0°C |
| Pressure Range | 0.2–2.0 kg/cm²G (Optional: 0.2–4.0 kg/cm²G) |
| Ramp Time | ~120 min (from ambient to 140°C) |
| Internal Chamber Dimensions | Ø45×45 cm or Ø65×60 cm |
| Construction Material | Inner & Outer Chamber – SUS316 Stainless Steel (Body), SUS304 Stainless Steel (Exterior Casing) |
| Power Supply | 1φ 220V 60Hz / 3φ 380V 50Hz, 20A |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 13,500 (FOB) |
| Internal Dimensions (Ø × H) | Φ250×300 mm to Φ650×600 mm |
| External Dimensions (W×H×D) | 500×500×700 mm to 950×900×1100 mm |
| Operating Temperature Range | 105–135 °C (143 °C optional) |
| Relative Humidity Range | 70–100 % RH |
| Steam Pressure Range | 0–2.0 kg/cm² (gauge), up to 3.0 kg/cm² on special order |
| Power Supply | AC 220 V / 380 V, 50/60 Hz |
| Safety Features | Dual overheat protection, door interlock, pressure relief valve, low-water cutoff, automatic steam purge, auto-fill and manual drain functions |
| Compliance | Designed per JESD22-A110, JEDEC Standard for HAST |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | +100°C to +132°C |
| Temp. Uniformity | ±1.5°C |
| Temp. Stability | ±0.5°C |
| Humidity Range | 75–100% RH (Saturated Steam) |
| Humidity Uniformity | ±3.0% RH |
| Humidity Stability | ±1.5% RH |
| Pressure Range | 0–4 kg/cm² (gauge), with operating range 1.0–3.0 kg/cm² |
| Max. Safety Pressure Capacity | 4 kg/cm² (≈490 kPa gauge, equivalent to ~5 atm absolute) |
| Test Duration | 0–999 hours |
| Pressurization Time | ~45 min (0 → 2.00 kg/cm²) |
| Heating Time | ~10 min (+100°C → +132°C, no-load, air temperature average) |
| Circulation Method | Natural convection of saturated steam |
| Control System | Microprocessor-based PID controller with PT-100 RTD sensing, LED time display, analog pressure gauge, and manual water inlet valve with auto-refill capability |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Internal Chamber Dimensions | Φ25×35 cm, Φ30×45 cm, Φ40×55 cm, Φ50×60 cm |
| Temperature Range | 105–132°C, 105–142.9°C, 105–155°C |
| Pressure Range | 0.2–2.0 kg/cm² (gauge), 0.2–3.0 kg/cm² (gauge), 0.2–3.5 kg/cm² (gauge) |
| Humidity Range | 65–100% RH (adjustable) |
| Controller | Dual-language (English/Chinese), USB & RS-232C interfaces, real-time data logging and curve export |
| Resolution | Temperature: 0.1°C, Humidity: 0.1% RH, Pressure: 0.1 kg/cm² |
| Temperature/Humidity Stability (Unsaturated Mode) | ±0.5°C / ±2.5% RH |
| Temperature/Humidity Stability (Saturated Mode) | ±0.5°C / 100% RH |
| Uniformity | ±0.5°C / ±5% RH |
| Bias Terminals | Standard: 8 channels (optional: 8–55 channels), AC/DC 125 V / 1 A |
| Pressurization Time | ~45–55 min depending on configuration |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,000 (FOB) |
| Internal Dimensions (Ø × L) | 30 cm × 50 cm |
| External Dimensions (W × H × D) | 56 cm × 45 cm × 82 cm |
| Operating Pressure Range | Up to 3 atm (gauge) |
| Temperature Range | 100 °C to 130 °C |
| Humidity Range | 85–100% RH (saturated steam environment) |
| Water Supply | Automatic float-controlled stainless steel reservoir |
| Safety Compliance | Meets IEC 60068-2-66, JESD22-A102D, MIL-STD-202 Method 108, and JEDEC JESD22-A110 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Internal Chamber Dimensions | Φ250×450 mm / Φ300×450 mm / Φ400×450 mm |
| Temperature Range | 100–132 °C |
| Humidity Range | 75–100 % RH (saturated steam) |
| Pressure Range | 0–2.5 kg/cm² above ambient atmospheric pressure |
| Circulation Method | Natural convection of saturated steam |
| Temperature Sensor | PT-100 Ω RTD (platinum resistance thermometer) |
| Heating Element | Insulated, high-voltage-rated resistive heater |
| Chamber Material | Stainless steel cylindrical inner chamber with arc-shaped interior walls |
| Sealing Mechanism | Self-tightening elastomeric packing under internal pressure |
| Pre-test Vacuum Function | Integrated vacuum pump with ≤1 µm particulate filtration |
| Safety Protection | Critical-point limit monitoring with fault indication and automatic shutdown |
| Auxiliary Functions | Timed post-test drying cycle |
| Water Management | Automatic water replenishment and controlled pressure release at test completion |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Temperature Range | 105–132 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Stability | ±0.5 °C |
| Humidity Range | 75–100 % RH |
| Humidity Stability | ±2.5 % RH |
| Humidity Uniformity | ±5.0 % RH |
| Pressure Range | 0.05–0.196 MPa (0.5–2.0 kgf/cm²) |
| Ramp Time (Temp) | ≤35 min (25→132 °C) |
| Ramp Time (Pressure) | ≤40 min (0→0.196 MPa) |
| Safety | Overpressure, overtemperature, and vacuum-failure interlocks |
| Compliance | Designed per JESD22-A110, JEDEC Standard, MIL-STD-883 Method 1030, and IEC 60068-2-66 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Temperature Range | 105–132 °C (control point) |
| Temperature Uniformity | ±2.0 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 75–100 % RH (control point) |
| Humidity Fluctuation | ±2.5 % RH |
| Humidity Uniformity | ±5.0 % RH |
| Pressure Range | 0.05–0.196 MPa (0.5–2 kgf/cm²) |
| Ramp Time (Ambient to 132 °C) | ≤35 min |
| Pressure Ramp Time (Ambient to 2 kgf/cm²) | ≤40 min |
| Water Level Auto-Replenishment | Yes |
| Post-Test Drying Function | Electric Heating Dry Mode |
| Compliance | ASTM B809, JESD22-A102, JEDEC JESD22-A110, IEC 60068-2-66 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Industrial Distributor |
| Price | USD 14,200 (FOB) |
| Chamber Volume | 75.4 L (Ø400 mm × L600 mm) |
| External Dimensions | 900 × 700 × 1600 mm (W×D×H) |
| Inner Tank Material | SUS316 Stainless Steel (3 mm thick) |
| Outer Casing | Optional SUS304 or Powder-Coated Steel |
| Insulation | Rock Wool + Rigid Polyurethane Foam (≥80 mm) |
| Steam Generator | Titanium Alloy Heating Element (Corrosion-Resistant) |
| Control System | Delta DOP-107EV Color Touch HMI + PLC-Based PID Algorithm |
| Temperature Sensor | PT-100 Platinum RTD (Class A, ±0.15 °C) |
| Pressure Indication | Analog Bourdon Tube Gauge (0–300 kPa, ±1.6% FS) |
| Humidity Control | Saturated Steam Generation with Auto-Water Refill (No Downtime Required) |
| Compliance | GB/T 10586–1989, GB/T 2423.3–2016 (IEC 60068-2-3), MIL-STD-810G Method 502.5, GJB 150.9A–2009, GB/T 2423.34–2012 (IEC 60068-2-52), MIL-STD-883K Method 1004.2 |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HS-1000B |
| Instrument Type | Upright Chamber |
| Humidity Range | 20–98% RH |
| Temperature Fluctuation | ±0.5°C |
| Humidity Deviation | ±2.0% RH |
| Heating Rate | 1–3°C/min |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HS-408A (Large-Scale High-Low Temperature Environmental Test Chamber) |
| Temperature Deviation | ±2.0°C |
| Heating Time | ≤60 min (from 20°C to 100°C) |
| Cooling Time | ≤40 min (to −20°C) / ≤60 min (to −40°C) / ≤80 min (to −70°C) |
| Temperature Range Options | A: −20°C to +150°C |
| B | −40°C to +150°C |
| C | −70°C to +150°C |
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±2.0°C |
| Temperature Fluctuation | ±0.5°C |
| Heating Rate | 1–3°C/min |
| Cooling Rate | 0.7–1.0°C/min |
| Internal Dimensions (W×D×H) | 600 × 800 × 850 mm |
| Internal Material | SUS#304 Stainless Steel |
| External Material | SUS#304 Stainless Steel + Powder-Coated Finish |
| Insulation | High-Density PU Foam with Vacuum-Sealed Layer |
| Control Resolution | 0.01°C |
| Temperature Control Accuracy | ±0.3°C |
| Power Supply | AC 380V ±10%, 50 Hz, 3-phase 4-wire |
| Communication Interface | RS-232 with PC-compatible control software |
| Safety Protections | Leakage current cutoff, compressor high-pressure/overheat/overcurrent protection, fan overheat protection, fuse overload protection, audible alarm |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HS-CJ-500B |
| Price Range | USD 28,000 – 70,000 (FOB Shanghai) |
| High-Temperature Zone Range | RT+10°C to +200°C |
| Low-Temperature Zone Range | −10°C to −65°C (B-type configuration) |
| Thermal Shock Temperature Range | +60°C to −55°C |
| Temperature Stability | ±0.5°C |
| Temperature Uniformity | ±2.0°C |
| Heating Rate | ≤30 min (RT to +200°C) |
| Cooling Rate | ≤55 min (+25°C to −65°C) |
| Door Switching Time | ≤10 s |
| Temperature Recovery Time | ≤5 min |
| Controller Resolution | 0.1°C (temperature), 0.01°C (display) |
| Power Supply | AC 380 V ±10%, 50 ±0.5 Hz, 3-phase 4-wire + PE |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HS-SC-100 |
| Test Chamber Volume | 1 m³ (1000 × 1000 × 1000 mm W×H×D) |
| External Dimensions | 1480 × 1960 × 1450 mm (W×H×D) |
| Temperature Range | RT+10°C to +60°C (adjustable) |
| Humidity Control | ≤25% RH (displayed on controller) |
| Dust Medium | Dry talc or silica cement powder, particle size ≤75 µm (mesh aperture), metal wire diameter 50 µm |
| Dust Concentration | 2–4 kg/m³ |
| Airflow Velocity | 0–15 m/s (adjustable, nominal test velocity 2 m/s) |
| Settling Dust Rate | 6 g/m²/day |
| Vibration Mode | Intermittent/continuous (0–9999 min adjustable) |
| Blowing Mode | Intermittent/continuous (time programmable) |
| Vacuum Pump Flow Rate | 60–600 L/h |
| Dust Recovery System | Conical stainless steel dust collector with shaker mechanism |
| Chamber Interior | SUS304 stainless steel (1.2 mm thickness) |
| Exterior | SECC steel (1.5 mm thickness), powder-coated |
| Control System | PLC-based programmable logic controller with high-precision microcomputer interface |
| Compliance | GB/T 2423.37–2006, GJB 150.12, GB/T 10485–2007, GB 4208–2017 (IP5X/IP6X) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price Reference | USD 3,100 (approx.) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Reference | USD 3,100 (ex-works, subject to configuration and certification requirements) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Reference | USD 3,100 (FOB) |
| Compliance Standards | GB/T 5170.2–1996, GB/T 10592–1993, GB/T 2423.2–2008 (IEC 60068-2-2), GJB 150.3A–2009, GJB 150.4A–2009, MIL-STD-810G |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Reference | USD 3,100 (excl. tax & freight) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 920 (FOB) |
| Temperature Range | Ambient +20°C to 500°C |
| Interior Material | SUS304 Stainless Steel |
| Exterior Material | 1.2 mm Cold-Rolled A3 Steel with Powder Coating |
| Insulation | Rigid Polyurethane Foam + Glass Fiber |
| Door Insulation | Glass Fiber Mat |
| Heating System | 2 kW Nickel-Chromium Far-Infrared Heaters (Independent Circuit) |
| Control System | Fuji Electric PXR Series PID Controller with SSR Output |
| Sensor | Pt100 Platinum Resistance Thermometer |
| Air Circulation | Forced Horizontal Airflow via High-Temperature Turbine Fan (SUS310S Shaft, Ceramic Bearings) |
| Safety Features | Overtemperature Cut-off, Leakage Current Protection, Real-Time Thermal Runaway Monitoring |
| Compliance | Designed per IEC 60068-2-2 (Test B: Dry Heat), ASTM D3045, and ISO 188 Annex C for thermal aging of polymers |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 920 (approx. based on ¥6500 at 1:7.07 exchange rate) |
| Temperature Range | Ambient +20°C to 500°C |
| Interior Material | SUS304 Stainless Steel |
| Exterior Material | 1.2 mm A3 Cold-Rolled Steel with Powder Coating |
| Insulation | Rigid Polyurethane Foam + Glass Fiber |
| Heating System | PID + Solid-State Relay (SSR) Controlled Resistive Heating |
| Air Circulation | Forced Horizontal Airflow via High-Temperature Turbine Fan |
| Temperature Sensor | Pt100 Platinum Resistance Thermometer |
| Compliance | GB/T 2423.2-2008 (Equivalent to IEC 60068-2-2) |
| Safety Features | Overtemperature Cut-off, Leakage Current Protection, Audible/Visual Alarm |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 920 (FOB) |
| Temperature Range | Ambient +20°C to 500°C |
| Chamber Construction | External SECC steel with powder-coated finish |
| Insulation | Rigid polyurethane foam + glass fiber (walls & door) |
| Air Circulation | Forced horizontal airflow via high-temp resistant centrifugal fan |
| Heating System | PID + SSR controlled far-infrared Ni-Cr alloy heaters (2 kW × 1) |
| Safety | Dual-stage overtemperature protection, automatic load cutoff, thermal fuse |
| Compliance | Designed per GB/T 2423.2-2008 (IEC 60068-2-2:2007 equivalent) |
| Control Interface | Digital PID controller with auto-tuning, real-time temperature display, and deviation alarm |
| Key | Brand: OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 300°C (customizable up to 500°C) |
| Control Accuracy | ±0.5°C |
| Temperature Uniformity | ±1.5°C |
| Interior Material | SUS#304 Stainless Steel |
| Exterior Material | Powder-Coated Cold-Rolled Steel |
| Heating System | 2 kW Nickel-Chromium Far-Infrared Heater |
| Control System | Microprocessor-Based PID Controller with SCR Power Regulation |
| Compliance | GB/T 2423.2 (High-Temperature Environmental Testing for Electrical and Electronic Products) |
| Power Supply | AC 220±5% V / 50 Hz or AC 380±5% V / 50 Hz |
| Internal Dimensions (OK-T-72) | 45×40×40 cm (W×H×D) |
| Internal Dimensions (OK-T-150) | 50×60×50 cm (W×H×D) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT+20°C to 500°C (customizable) |
| Control Accuracy | ±0.5°C |
| Uniformity | ±1.5°C |
| Internal Construction | SUS304 Stainless Steel |
| External Construction | 1.2 mm A3 Steel with Powder-Coated Finish |
| Insulation | Rigid Polyurethane Foam + Glass Fiber |
| Air Circulation | Forced Horizontal Airflow via High-Temperature Turbine Fan |
| Heating System | PID + Solid-State Relay (SSR) Control |
| Safety Protections | Over-Temperature Cut-Off, Leakage Current Protection, Audible/Visual Alarm |
| Compliance | GB/T 2423.2 (Equivalent to IEC 60068-2-2), GLP-Compatible Operation |
| Key Features | Temperature Range: RT +10 °C to 300 °C (customizable up to 500 °C) |
|---|---|
| Internal Dimensions | 500 × 600 × 500 mm (W×H×D) |
| External Dimensions | 700 × 1200 × 700 mm (W×H×D) |
| Temperature Uniformity | ±1.5 °C |
| Control Accuracy | ±0.5 °C |
| Heating System | Dual independent 2 kW nickel-chromium far-infrared heaters |
| Sensor | PT100 platinum resistance thermometer |
| Controller | LED digital or optional high-resolution touchscreen microprocessor controller with programmable timer (0–999 min) |
| Air Circulation | Forced convection via bottom-mounted centrifugal blower with left-side lateral airflow duct |
| Construction | Interior—SUS#304 stainless steel |
| Standard Accessories | Two adjustable stainless steel wire shelves |
| Power Supply | AC 220 V ±5 % / 50 Hz or AC 380 V ±5 % / 50 Hz |
| Total Rated Power | 4 kW (dual heater configuration) |
| Safety Protections | Over-temperature alarm, over-temperature cut-off, earth leakage protection |
| Compliance | Designed and validated per GB/T 2423.2–2022 (“Environmental testing — Part 2: Tests — Test B: Dry heat”) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 920 (FOB) |
| Internal Chamber Material | SUS304 Stainless Steel |
| Insulation | Rigid Polyurethane Foam + Glass Fiber |
| Door Insulation | Glass Fiber Cotton |
| Outer Casing | 1.2 mm Cold-Rolled A3 Steel with Electrostatic Powder Coating |
| Heating System | 2 kW Far-Infrared Ni-Cr Alloy Heater (Independent Circuit) |
| Temperature Control | Fuji Electric PXR Series PID Controller with Auto-Tuning |
| Sensor | Pt100 Platinum Resistance Thermometer |
| Compliance | GB/T 2423.2-2008 (Equivalent to IEC 60068-2-2:2007, ASTM D3574, ISO 188) |
| Safety Features | Over-Temperature Alarm & Cut-Off, Earth Leakage Protection, Real-Time Monitoring |
| Key | Brand: OEM |
|---|---|
| Origin | Imported |
| Construction | SUS304 Inner Chamber, A3 Steel Outer Casing w/ Powder Coating |
| Temperature Range | RT+10°C to 200°C / 300°C |
| Uniformity | ±2°C |
| Temperature Stability | ±0.5°C |
| Air Exchange Rate | 2–100 cycles/hour |
| Exchange Timing | 1 min – 99 h adjustable |
| Power | 4.0–9.0 kW (model-dependent) |
| Internal Dimensions | 450×450×500 mm to 800×1000×1000 mm |
| Insulation | High-Density Glass Fiber Mat |
| Air Circulation | Horizontal Forced Convection w/ Adjustable Baffles |
| Controller | PID + SSR Microprocessor-Based Digital Controller |
| Timer Range | 1–9999 min |
| Safety Protections | Overtemperature, Overcurrent, Leakage, Motor Overheat, Short-Circuit |
| Compliance | ASTM D5423-09 (Type II), ASTM D5374-05, UL 1581, GB/T 2423.2, IEC 60068-2-2, JIS C 0021, VDE 0470 |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 200 °C (standard), up to 300 °C or 500 °C (custom) |
| Control Accuracy | ±0.5 °C |
| Temperature Uniformity | ±1.5 °C |
| Interior Material | SUS304 Stainless Steel |
| Exterior Material | 1.2 mm A3 Cold-Rolled Steel with Powder Coating |
| Insulation | Rigid Polyurethane Foam + Glass Fiber |
| Heating System | 2 kW Far-Infrared Ni-Cr Alloy Heater |
| Controller | Fuji PID Digital Microprocessor Controller with Auto-Tuning |
| Sensor | Pt100 Platinum Resistance Thermometer |
| Safety Features | Over-Temperature Alarm, Over-Temperature Cut-Off, Earth Leakage Protection |
| Compliance | GB/T 2423.2 (High-Temperature Environmental Testing for Electrical and Electronic Products) |
| Power Supply | AC 220 V ±5% / 50 Hz or AC 380 V ±5% / 50 Hz |