Environmental Test Chamber
Filter
Showing 1741–1770 of 2010 results
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling Capacity | Dual-Stage Cascade Refrigeration System |
| Compressor | Imported Semi-Hermetic German Compressor |
| Cooling Method | Water-Cooled (Requires External 10 m³/h Cooling Tower) |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2022, ISO 16750-4, QC/T 17-2019 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Power Supply | 3φ 5 kW / 380 VAC ±10% or 2φ 3 kW / 220 VAC ±10% |
| Inner Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Outer Chamber Material | Powder-Coated Steel or Stainless Steel |
| Insulation | Rigid Polyurethane Foam + Glass Wool |
| Refrigeration | Twin-Circuit Cascade System with French Tecumseh Hermetic Compressors |
| Refrigerant | Environmentally Compliant HFC Blend |
| Controller | Touchscreen HMI with PID Algorithm |
| Safety Protections | Compressor Overheat/Overcurrent/High-Pressure, Dry Heater Burnout Prevention, Chamber Overtemperature, Low-Water-Level Alarm |
| Standard Accessories | Viewing Window with Interior LED Lighting, φ50 mm Cable Port (Left Side), Two Adjustable Sample Racks, Castor Wheels, Integrated Humidification Tank |
| Optional | RS-485/RS-232 Interface, External Data Logger, Internal Glass Observation Door, Glove Port |
| Compliance | Designed to Support ASTM D5229, ISO 11357-5, MIL-STD-810H Method 503.6, IEC 60068-2-14 Test Nb |
| Brand | Generic OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Control System | Touchscreen PID Controller with Schneider Electrical Components |
| Display Resolution | 0.01°C |
| Operation Modes | Constant & Programmable |
| Max Program Capacity | 120 Programs × 99 Steps Each |
| Total Cycles | Up to 999 |
| Power Failure Recovery | Resume from Breakpoint or Abort |
| Real-Time Monitoring | Segment Time, Remaining Time, Cycle Count, Temp Deviation, Heating/Cooling Status, Calendar Timestamp |
| Fault Diagnostics | On-Screen Error Code Indexing |
| Alarm Types | Absolute Limit, Deviation, Sensor Failure |
| Comprehensive Safety Interlocks | Phase Loss/Sequence Imbalance, Fan Overload, Overtemperature (Chamber & Compressor), High-Pressure Cutout, Ground Fault, Emergency Stop |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Controller Options | TEMI880 Color Touchscreen Programmable Controller (English/Chinese) or TEMI300 Membrane Keypad Controller (English Only) |
| Refrigeration System | Twin-Compressor Dual-Circuit Design with Original Tecumseh (France) Hermetic Compressors |
| Internal Construction | SUS304 Stainless Steel Interior |
| External Construction | Cold-Rolled Steel with Epoxy Powder Coating or Optional SUS304 Brushed Finish |
| Insulation | Polyurethane Rigid Foam + Ultra-Fine Glass Fiber Blanket |
| Door Seal | Dual-Layer High-Temperature Silicone Gasket |
| Air Circulation | Wide-Band Forced-Air System with Multi-Blade Centrifugal Blower |
| Cooling Method | Air-Cooled Condensation |
| Temperature Range | −70 °C to +180 °C (Standard Dual-Zone Configuration) |
| Humidity Range | 20–98% RH (Optional Humidity Capability) |
| Compliance | ASTM D5229, ISO 16750-4, MIL-STD-810H Method 503.7, IEC 60068-2-14 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Control System | TEMI880 Color Touchscreen PLC Controller (EN/CN Switchable) or TEMI300 Membrane Keypad Controller (EN Only) |
| Protection Features | Compressor Overheat/Overcurrent/High-Pressure Protection, Dry-Run Prevention for Heater & Humidifier, Chamber Over-Temperature Alarm, Low-Water-Level Detection |
| Standard Accessories | Dual-Layer Tempered Glass Viewing Window, Φ50 mm Test Port (Left Side), Two Adjustable Sample Racks, Fluorescent Interior Lighting, Four Swivel Casters with Brakes, Removable Humidifier Tank, RS485/RS232 Communication Interface, PC-Based Monitoring & Control Software |
| Temperature/Humidity Control | Balanced Temperature & Humidity Control (BTSC) Architecture |
| Operating Ambient | +5°C to +35°C |
| Heating | Nickel-Chromium Alloy Wire Heaters |
| Humidification | Surface Evaporation Type |
| Air Circulation | Centrifugal Blower with Wide-Band Forced-Air Flow (Top-Out/Bottom-In) |
| Condensation Method | Air-Cooled |
| Refrigeration | Original Tecumseh (France) Hermetic Compressor |
| Refrigeration Circuit | Dual-Staged Low-Temperature Loop Design |
| Airflow Uniformity | Multi-Vane Impeller Fan Ensures <±1.5°C Temp Deviation Across Working Volume |
| Exterior Material | Cold-Rolled Steel w/ Epoxy Powder Coating or Optional SUS304 Brushed Stainless Steel |
| Interior Material | SUS304 Stainless Steel |
| Insulation | Rigid Polyurethane Foam (≥100 mm) + Ultra-Fine Glass Fiber Mat |
| Door Seal | Dual-Section High/Low-Temperature Resistant Silicone Gasket |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported (Global Sourcing) |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | −70°C to +180°C |
| Thermal Transition Time | ≤15 s (50 K transfer between chambers) |
| Control System | TEMI880 Color Touchscreen PLC Controller (EN/CN Switchable) |
| Compliance | IEC 60068-2-14, MIL-STD-810H, JIS Z 8701 |
| Refrigeration | Twin-Circuit Cascade System with Original Tecumseh/Tecumseh-derived Hermetic Compressor |
| Insulation | 120 mm Polyurethane Rigid Foam + 80 mm Ultra-Fine Glass Fiber |
| Airflow | Wide-Band Forced Convection (Top-Out/Bottom-In), ≥3.5 m/s Uniform Velocity |
| Humidity Control | Surface Evaporation Type (Optional), RH 10–98% (at 25–85°C) |
| Power Supply | 380 VAC ±10%, 3-Phase, 50/60 Hz |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | −70°C to +180°C |
| Thermal Transition Time | ≤5 min (typical, 150°C ↔ −40°C) |
| Internal Volume | 150 L (standard configuration) |
| Control System | TEMI880 Color Touchscreen Programmable Controller (EN/CN Switchable) or TEMI300 Membrane Keypad Controller (English Only) |
| Compliance | IEC 60068-2-14, MIL-STD-810H Method 503.5, GB/T 2423.22 |
| Key | Temperature Range Options: -20°C to 150°C |
|---|---|
| Humidity Range (optional) | 20–98% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ≤ ±0.5°C |
| Humidity Deviation | +2 / −3% RH |
| Heating Rate | 1.0–3.0°C/min |
| Cooling Rate | 0.7–1.0°C/min |
| Control System | Programmable Touchscreen Controller (English/Chinese UI) |
| Temperature Setpoint Accuracy | ±0.1°C |
| Humidity Setpoint Accuracy | ±1% RH |
| Sensor Type | PT100 Platinum Resistance Thermometer |
| Heating Method | Independent Nickel-Chromium Alloy Heaters |
| Humidification | Stainless Steel Surface Evaporation System |
| Dehumidification | Evaporator Coil Dew-Point Contact Method |
| Exterior Material | Cold-Rolled Carbon Steel with Phosphating & Electrostatic Powder Coating OR SUS304 Brushed Stainless Steel |
| Interior Material | SUS304 Mirror-Finish Stainless Steel |
| Insulation | Polyurethane Rigid Foam + Ultra-Fine Glass Fiber |
| Door Seal | Dual-Layer High/Low-Temperature Resistant Silicone Rubber |
| Power Supply | AC 380V ±10%, 50 ±0.5 Hz, 3-Phase 5-Wire |
| Refrigeration | Twin-Stage Cascade Air-Cooled System with Imported Hermetic Compressors (France) |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Controller Options | TEMI880 Color Touchscreen Programmable Climate Controller (English/Chinese Switchable) or TEMI300 Membrane Keypad Controller (English Only) |
| Temperature Range | −70 °C to +180 °C |
| Humidity Range | 20–98% RH |
| Cooling System | Dual-Stage Cascade Refrigeration with Original Tecumseh (France) Hermetic Compressor |
| Insulation | Rigid Polyurethane Foam (100 mm thick) + Ultra-Fine Glass Fiber |
| Interior Material | SUS304 Stainless Steel |
| Exterior Material | Powder-Coated Cold-Rolled Steel or Optional Brushed SUS304 |
| Airflow | Wide-Band Forced Convection via Multi-Wing Centrifugal Blower |
| Compliance | ASTM D5276, IEC 60068-2-14, MIL-STD-810H Method 503.7 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | -40°C to +150°C / -60°C to +150°C / -70°C to +150°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Uniformity | ±1.5°C |
| Temperature Deviation | ≤2.0°C |
| Ramp Rate | 3–25°C/min (linear, programmable) |
| Load Capacity | 5–50 kg aluminum mass standard |
| Control System | PID-based BTC (Balance Temperature Control) |
| Refrigeration | Dual-stage mechanical cascade system with R404A/R23 refrigerants |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2012, MIL-STD-2164A |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Control System | TEMI880 Color Touchscreen Controller (EN/CN Switchable) or TEMI300 Membrane Keypad Controller (English Only) |
| Protection Features | Compressor Overheat/Overcurrent/High-Pressure Protection |
| Standard Configuration | Dual-Layer Tempered Glass Viewing Window |
| Climate Control Method | Balanced Temperature and Humidity Control (BTSC) |
| Operating Ambient | +5°C to +35°C |
| Heating Element | Nickel-Chromium Alloy Wire Heater |
| Humidification Method | Surface Evaporation Type |
| Air Circulation | Centrifugal Blower with Wide-Spectrum Forced Convection (Top-Out/Bottom-In) |
| Condensation Method | Air-Cooled |
| Refrigeration Unit | Original French Tecumseh Hermetic Compressor |
| Refrigeration Circuit | Dual-Stage Cascade Low-Temperature System |
| Airflow Design | Multi-Vane Impeller for Uniform Distribution |
| Exterior Material | Cold-Rolled Steel with Anti-Rust Treatment & Electrostatic Powder Coating OR Optional SUS304 Brushed Stainless Steel |
| Interior Material | SUS304 Stainless Steel Sheet |
| Insulation | Rigid Polyurethane Foam (≥100 mm Thickness) + Ultra-Fine Glass Fiber Blanket |
| Door Seal | Dual-Layer High-Temp/Low-Temp Resistant Silicone Rubber Gasket |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported (Germany/USA/Japan-sourced Components) |
| Manufacturer Type | Authorized Distributor & Integration Partner |
| Compliance | GB/T 2423.1–2, GB/T 2423.22, GJB 150.3–5, IEC 60068-2-14, SJ/T 10186–10187, QC/T 17, EIA-364-32 |
| Cooling Capacity | Dual-Stage Cascade Refrigeration System with Imported Semi-Hermetic Compressors |
| Cooling Water Requirement | External 10 m³/h Recirculating Cooling Tower (User-Supplied) |
| Temperature Range | –65°C to +180°C (Typical Configuration) |
| Transition Time | ≤15 s (Between Chambers, Two-Zone), ≤30 s (Three-Zone Transfer Mechanism) |
| Internal Volume Options | 50 L to 1000 L |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported (Germany/USA Engineering Standard) |
| Manufacturer Type | Authorized Distributor |
| Cooling System | Dual-Stage Cascade Refrigeration with External Water-Cooled Condenser |
| Temperature Range | -65°C to +180°C (Standard Configuration) |
| Transition Rate | ≥10°C/s (Typical, 5–15°C/s depending on load & chamber size) |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–1989, GJB 150.5–1986, GJB 360.7–1987, GJB 367.2–1987, IEC 60068-2-14 (Test N), SJ/T 10186–1991 & SJ/T 10187–1991 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | -65°C to +150°C |
| Transition Time (Typical) | ≤15 s (between chambers) |
| Compliance | ASTM D648, ISO 11359-2, IEC 60068-2-14, MIL-STD-810H Method 503.5, GB/T 2423.22-2022, GJB 150.5A-2009 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −99.9 °C to +200 °C |
| Humidity Control | Steam Humidification, 0–100 % RH |
| Resolution | 0.1 °C / 0.1 % RH |
| Programmable Memory | 120 programs × 1200 segments |
| Cycle Repetition | Up to 999 cycles |
| Control Interface | Touchscreen HMI with BTHC (Balanced Temperature & Humidity Control) |
| Safety Features | SSR-based PID control, PT-100 dual-sensor monitoring, real-time fault diagnostics, power cutoff on critical anomaly |
| Compliance | Designed for ASTM D573, ISO 188, IEC 60068-2-14, MIL-STD-810G thermal shock protocols |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Cooling System | Dual-Stage Cascade Refrigeration (Water-Cooled) |
| Temperature Range | –70 °C to +180 °C |
| Thermal Transition Time (Typ.) | ≤5 min (–70 °C ↔ +180 °C) |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, GB/T 10592–2008, GJB 150.3A–2009 |
| Configuration Options | Two-Zone (Lift-Basket) or Three-Zone (Separate Hot/Cold/Testing Chambers) |
| Cooling Water Requirement | 10 m³/h Circulating Flow (External Cooling Tower Required) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -20 °C to +80 °C |
| Internal Chamber Dimensions | 40 × 40 × 40 cm (D × W × H) |
| Temperature Resolution | 0.1 °C |
| Temperature Control Accuracy | ±2 °C |
| Refrigeration System | R404A refrigerant |
| Compressor | Imported high-efficiency hermetic scroll compressor |
| Cooling Method | Air-cooled condenser |
| Evaporator | Finned-tube coil type |
| Control System | PID auto-tuning with SSR output |
| Display | LED digital temperature & timer display |
| Safety Protections | Compressor overload protection, earth-leakage circuit breaker |
| Chamber Material | 304 stainless steel interior |
| Optional Features | Dual-sensor temperature control, high-temp active cooling, RS-485/USB communication interface |
| Key Features | Two-zone (hot/cold chambers with basket transfer) or three-zone (hot chamber / cold chamber / test chamber) architecture |
|---|---|
| Temperature Range | Hot Zone up to +200 °C |
| Test Zone | −65 °C to +150 °C |
| Temperature Transition Time | ≤5 min (typical recovery) |
| Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration System | Dual-stage cascade refrigeration with imported semi-hermetic compressors (Germany) |
| Refrigerants | R404A / R23 (ozone-friendly) |
| Insulation | High-density fire-retardant PU foam |
| Interior | Mirror-finish SUS304 stainless steel |
| Exterior | SUS304 or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Cooling Water Requirement | External cooling tower (10 m³/h capacity required) |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–2002, GJB 150.5–86, IEC 60068-2-14, EIA-364-32, QC/T 17–92, SJ/T 10186–91 & 10187–91 |
| Customizable Internal Dimensions | 40×35×30 cm to 70×60×60 cm (W×H×D) |
| Key | Brand: OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500–18,900 (FOB) |
| Temperature Range (Hot Zone) | RT to +200 °C |
| Temperature Range (Cold Zone) | RT to −70 °C |
| Test Zone Range | +60 °C to +150 °C (hot shock) |
| Temp. Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration | Dual-stage cascade system with R404A/R23 refrigerants |
| Construction | Interior—SUS304 mirror-finish stainless steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Key | Temperature Range Options: −70°C to +150°C |
|---|---|
| Humidity Range | 30–98% RH |
| Humidity Deviation | +2 to −3% RH |
| Temperature Fluctuation | ±0.5°C |
| Temperature Uniformity | ≤±2°C |
| Avg. Ramp Rate | 0.7–1.0°C/min |
| Timer Setting Range | 0–9999 h |
| Power Supply | AC 380 V |
| Internal Material | SUS304 Stainless Steel Mirror Finish |
| External Material | A3 Steel with Powder Coating |
| Observation Window | Embedded Heated Tempered Glass with LED Illumination |
| Test Port | Ø50 mm |
| Compliance | Designed to Support ASTM D5229, ISO 16750-4, IEC 60068-2-14, MIL-STD-810H Thermal Shock Protocols |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,500 (FOB) |
| Temperature Range | −70 °C to +180 °C |
| Transition Time (−40 °C ↔ +125 °C) | ≤15 s (air-to-air, standard configuration) |
| Thermal Soak Time | Adjustable from 1 min to 999 h 59 min per segment |
| Cycle Count | 1–999 cycles programmable |
| Control System | PID-based PLC with auto-tuning |
| Communication Interfaces | RS-232, RS-485, USB, Ethernet (LAN) |
| Compliance | ASTM D5229/D5229M, ISO 16750-4, MIL-STD-810H Method 503.5, IEC 60068-2-14 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,500 (FOB) |
| Temperature Range | -65°C to +150°C |
| Transition Time | ≤15 s (between chambers) |
| Internal Volume | Standard 150 L, 250 L, 400 L, or 800 L configurations available |
| Compliance | IEC 60068-2-14, MIL-STD-810H Method 503.5, JIS Z 8702, GB/T 2423.22 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Power Supply | 3-Phase 380 VAC, 16 kW |
| Operating Ambient | 15–35 °C, ≤85% RH |
| Weight | ~450 kg |
| Safety Protections | Dual SSR zero-crossing controllers, compressor high-pressure/overload/overcurrent protection, phase-loss & reverse-phase protection, 16A 3P + 1P 6A circuit breakers, dryers, oil separators, refrigerant sight glass |
| Refrigeration System | Hermetic French Tecumseh compressors, eco-friendly R404A/R23 cascade refrigerant, finned condenser with forced-air cooling, multi-stage finned evaporator with auto-capacity modulation |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Brand | OEM / Custom-Branded |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Temperature Transition Time | ≤15 s |
| Temperature Recovery Time | ≤5 min |
| Control Resolution | ±0.1 °C |
| Refrigeration System | Twin-Circuit Cascade Design with Imported French Tecumseh Compressors |
| Construction | Stainless Steel Interior + Powder-Coated Steel Exterior |
| Cooling Medium | Eco-Friendly R404A/R23 Blend |
| Compliance | ISO 16750-4, JEDEC JESD22-A104, MIL-STD-810H Method 503.5, IEC 60068-2-14 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Brand | OEM / Generic |
|---|---|
| Origin | Imported |
| Distributor Type | Authorized Reseller |
| Price | USD 11,200 (FOB) |
| Temperature Range | -65°C to +180°C |
| Transition Time (Hot ↔ Cold) | ≤15 s |
| Temperature Recovery Time | ≤5 min |
| Control Resolution | ±0.1°C (Temp), ±1 s (Time) |
| Programmable Memory | 10 programs × 99 segments |
| Power Supply | AC 380 V ±10%, 50 Hz ±1 Hz, 3-phase 4-wire |
| Ambient Operating Conditions | 5–30°C, ≤85% RH |
| Construction | Outer Shell – Brushed SUS304 Stainless Steel |
| Standard Accessories | Multi-layer Heated Defrost Viewing Window, 2 Adjustable Sample Racks, 1 × Ø50 mm Cable Port |
| Safety Protections | Independent Over-Temperature Cut-off, Compressor High-Pressure & Overload Protection, Motor Thermal Overload, Phase Failure/Reverse Phase Detection, Dry-Run Prevention for Heating Elements |