| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | TAG 300/500 |
| Detection Method | Closed-Cup (TAG) |
| Operation Mode | Fully Automatic |
| Sample Temperature Range | −35 °C to +130 °C |
| Ignition Source | Ceramic-Coated Electric Igniter |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | SYD-3536D |
| Detection Method | Cleveland Open-Cup (COC) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 400 °C |
| Ignition Method | Active fuel-gas electronic ignition with visible flame |
| Power Supply | AC (220 ± 5%) V, 50 Hz |
| Max. Power Consumption | ≤750 W |
| Temp. Resolution | 0.1 °C |
| Heating Rate | 14–17 °C/min (initial), 5–6 °C/min (final 20 °C before preset flash point) |
| Flame Control | Precision adjustable gas valve |
| Data Transmission | Bluetooth 5.0 |
| Atmospheric Pressure Compensation | Integrated sensor with automatic flash point correction |
| Cloud Data Storage | Encrypted remote sync with audit-ready log history |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SYD-5208 |
| Detection Method | Closed-Cup (Pensky-Martens type) |
| Operation Mode | Fully Automatic |
| Temperature Range | 5°C to 30°C (ambient operating environment) |
| Ignition Method | Electronic spark igniter |
| Applicable Standards | GB/T 5208–2008, ISO 1523:2002, ISO 3679:2004 |
| Flash Point Range | –30°C to +100°C |
| Temperature Resolution | ±0.1°C |
| Cooling System | Integrated compressor-based bath cooling (no external chiller required) |
| Sample Volume | 2 mL (liquid), 4 mL (semi-solid/solid) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ≤300 W |
| Dimensions (L×W×H) | 490 × 520 × 390 mm |
| Net Weight | 25.5 kg |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | A-1190 |
| Price Range | USD 4,200 – 7,000 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Compliant Standards | GB/T 261-2008, GB/T 21615-2008, ASTM D93 |
| Repeatability | ≤2 °C |
| Ignition Method | Electronic spark ignition and adjustable gas flame |
| Temperature Range | 10–40 °C (ambient operating), 0–350 °C (test range) |
| Resolution | 0.1 °C |
| Data Storage | 120 test records onboard |
| Interface | RS-232 & RS-485 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Relative Humidity | <85% RH |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAFLASH |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D6450, ASTM D7094, SH/T 0768 |
| Repeatability | Excellent |
| Ignition Method | Electric Arc Ignition |
| Temperature Range | −25 °C to 420 °C (standard configuration: 0 °C to 200 °C |
| Sample Volume | 1 mL (ASTM D6450), 2 mL (ASTM D7094) |
| Cooling/Heating Technology | Patented PBT (Peltier-Based Thermoregulation) |
| Data Storage Capacity | >100,000 test reports with full audit trail |
| Power Supply | 85–264 V AC or 12 V DC |
| Sample Throughput | Up to 12 samples/hour |
| Temperature Accuracy | ±0.1 °C |
| Integrated Pollution Monitoring | CPT (Contamination Prevention Technology) |
| Optional Modules | EF01-HTM (high-temp module, up to 420 °C), EF02 LT (low-temp module, −40 °C to 120 °C with external chiller) |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAFLASH |
| Detection Method | Closed Cup |
| Operation Mode | Automatic |
| Temperature Range | −40 °C to 200 °C (optional high-temp module up to 420 °C |
| LT module with external cooling | −40 °C to 120 °C) |
| Ignition Source | Electric Arc |
| Repeatability | ±4.1 °C |
| Compliance Standards | ASTM D6450, ASTM D7094, SH/T 0768–2005 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | Eraflash S10 |
| Detection Method | Closed-Cup (ASTM D93 / ISO 2719 / IP 34 / GB/T 261 / SH/T 0768) |
| Temperature Range | −25 °C to 200 °C (optional high-temp module up to 420 °C) |
| Temperature Accuracy | ±0.1 °C |
| Test Duration | 3–5 min per sample (including cup cleaning) |
| Sample Volume | 1 mL or 2 mL |
| Auto-sampler Capacity | 10 positions |
| Data Storage | 100,000 test records |
| Display | 7-inch full-color capacitive touchscreen (Chinese UI) |
| Interfaces | 3× USB, 1× Ethernet, 1× RS232, LIMS-compatible serial protocol |
| Power Supply | 85–263 VAC, 47–63 Hz, 70 W |
| DC Option | 12 V / 4 A |
| Dimensions | 220 × 320 × 280 mm |
| Weight | 8 kg |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | Eraflash X |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | 18 °C to 370 °C |
| Ignition Method | Electric Arc Ignition |
| Repeatability | High |
| Compliant Standards | ASTM D7094, SH/T 0768 |
| Sample Volume | 2 mL |
| Cooling/Heating Technology | Peltier-Based Thermoelectric (PBT) |
| Data Storage Capacity | >100,000 test reports |
| Throughput | Up to 12 samples/hour |
| Temperature Accuracy | ±0.1 °C |
| Power Supply | 85–264 V AC or 12 V DC |
| Pollution Control | CPT Electrode Protection & Self-Cleaning Ignition System |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniFlash FLA |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Compliant Standards | ASTM D6450 (SH/T 0768) & D7094 |
| Temperature Range | 0 to 200 °C |
| Dimensions (W×H×D) | 312 × 402 × 390 mm |
| Weight | 20 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniFlash FLAH |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Compliant Standards | ASTM D6450 (SH/T 0768) & D7094 |
| Temperature Range | 10 to 400°C |
| Dimensions (W×H×D) | 312 × 402 × 390 mm |
| Weight | 20 kg |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FP Vision |
| Detection Method | Closed-Cup (ASTM D6450/D7094) |
| Temperature Range | 0–120 °C (standard), down to –25 °C with external chiller |
| Temp. Stability | ±0.05 °C |
| Sample Volume | 1–2 mL |
| Throughput | Up to 12 samples/hour |
| Interfaces | 4× USB, 2× LAN |
| Power | 100–240 V AC, 50/60 Hz, max. 180 W |
| Dimensions | 253 × 368 × 277 mm |
| Weight | 10.2–11.2 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FP VISION |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D6450 (SH/T 0768) & ASTM D7094 |
| Repeatability | ASTM D6450 ≤ 0.4°C, ASTM D7094 ≤ 0.5°C |
| Reproducibility | ≤ 0.9°C for both methods |
| Ignition Method | Electric Arc |
| Temperature Range | 0–120°C (no external cooling required) |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FPA VISION |
| Detection Method | Closed-Cup (ASTM D93, ISO 2719, IP 34, EN ISO 3679) |
| Compatibility | Fully compatible with MINIFLASH FP VISION and FPH VISION analyzers |
| Sample Capacity | 12 positions |
| Footprint | 0.18 m² |
| Operating Temperature Range | –25 °C to 400 °C |
| Cooling Option | External liquid cooling interface for autosampler chamber |
| Power Supply | Switch-mode power supply (SMPS) |
| Software Platform | VISION Cockpit™ PC software (21 CFR Part 11 compliant audit trail, multi-user role management, networked data synchronization) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FPA VISION |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Power Supply | 100–264 VAC, 45–63 Hz, Max. 50 W |
| Dimensions (W×H×D) | 435 × 425 × 415 mm |
| Height with FP(H) VISION mounted | 530 mm |
| Weight | 15.9 kg (turntable: 2.2 kg |
| fully loaded turntable | 4.2 kg) |
| Cooling | External liquid cooling interface |
| Compliance | CE-marked per EN standards for laboratory instruments |
| Software Platform | VISION Platform with Cockpit™ PC software |
| Interface | Dedicated hardware interface to MINIFLASH FP/H VISION analyzers |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-3536D |
| Detection Method | Cleveland Open-Cup (COC) |
| Operation Mode | Fully Automatic |
| Applicable Standard | GB/T 3536–2008 |
| Repeatability | ≤8 °C (flash point and fire point) |
| Ignition Method | Electronic spark ignition |
| Temperature Range | Ambient to 400 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Display | 8-inch industrial true-color touchscreen (Windows CE OS, bilingual Chinese/English interface) |
| Temperature Sensor | Imported German PT1000 (resolution: 0.1 °C) |
| Microcontroller | Renesas MCU |
| Data Storage | 120 test records onboard |
| Safety Features | Auto-shutdown on overtemperature, flame-quenching lid for fire point, real-time millisecond-level flash detection |
| Environmental Operating Conditions | 10–40 °C, RH ≤80% |
| Power Consumption | ≤500 W |
| Dimensions (lowered/lifted) | 520 × 360 × 310 / 420 mm (L×W×H) |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KS-9A |
| Price | USD 1,150 (FOB) |
| Temperature Range | 79 °C to 400 °C |
| Ignition Source | High-Stability Silicon Nitride Igniter |
| Repeatability | ≤4 °C |
| Applicable Standards | GB/T 3536, ASTM D92 |
| Accuracy | ±2 °C |
| Reproducibility | ≤8 °C |
| Heating Rate | Compliant with GB/T 3536 |
| Resolution | 0.1 °C |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤550 W |
| Dimensions (W×D×H) | 410 × 320 × 165 mm |
| Net Weight | 14.5 kg |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ABL-8 |
| Test Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 21789, IP 170, ISO 13736, ISO 1516, ISO 1523 |
| Temperature Range | −30 °C to +80 °C |
| Ignition System | Dual-mode (Gas Flame & Electric Spark) |
| Repeatability | High |
| Cooling Method | Peltier-based Semiconductor Cooling |
| Display | 5.7-inch Color LCD |
| Data Storage Capacity | 200 Test Records |
| Atmospheric Pressure Compensation | Integrated Barometric Sensor |
| Safety Features | Auto Fire Suppression, Fault Diagnostics, Wind Shield Enclosure |
| Compliance Support | ASTM D3278, ISO/IEC 17025 Traceability Framework, GLP Audit Trail Ready |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ACO-100 |
| Test Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ISO 2592, ASTM D92, IP 36 |
| Ignition Source | Electric or Gas Pilot Flame |
| Temperature Range | Ambient to 400 °C |
| Data Storage Capacity | 200 test records |
| Interface Options | USB, RS-232 |
| Optional Accessories | Thermal Printer, USB Keyboard, USB Flash Drive |
| Security | Password-protected test program |
| Safety Features | Auto-ignition detection, auto-extinguishing system (activated upon flash point confirmation or sustained flame ≥5 s) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | APM-100 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D93, GB/T 261, ISO 2719 |
| Ignition Source | Dual-mode (Gas Flame & Electric Spark) |
| Temperature Range | Ambient to 370 °C |
| Data Storage Capacity | 200 test records |
| Interface | USB (for keyboard, flash drive, and LIMS export) |
| Security | Password-protected test program |
| Safety Features | Integrated thermal cutoff, flame detection interlock, and automatic lid closure |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ASC-8C |
| Test Method | Closed-Cup Equilibrium Method |
| Operating Mode | Fully Automatic |
| Applicable Standards | ISO 3679, ISO 3680, ASTM D3278, ASTM D7236, IP 534 |
| Temperature Range | −30 °C to +100 °C |
| Ignition Source | Dual-mode (electric spark or gas flame) |
| Repeatability | High |
| Atmospheric Pressure Compensation | Integrated barometric sensor |
| Data Storage Capacity | 200 test records |
| Output Options | Thermal printer, USB export, LIMS integration |
| Security | Password-protected user interface |
| Compliance | Designed for GLP-compliant laboratories and routine QC environments |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | ST-1501 |
| Detection Method | Cleveland Open Cup (COC) |
| Operation Mode | Manual |
| Temperature Range | Ambient to 400 °C |
| Ignition Source | Adjustable Gas Flame |
| Repeatability | ≤4 °C |
| Compliant Standard | GB/T 3536-2008 |
| Accuracy | ±2 °C |
| Resolution | 1 °C |
| Heating Power | ≤600 W |
| Dimensions | 300 × 245 × 250 mm |
| Ambient Operating Conditions | 5–45 °C, 10–80% RH |
| Power Supply | 220 V ±10%, 50 Hz |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-151511 |
| Detection Method | Cleveland Open-Cup (COC) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 400 °C |
| Ignition Methods | Intelligent Electric Ignition (standard), Gas Ignition (optional) |
| Repeatability | Compliant with GB/T 3536–2008 and ASTM D92 |
| Applicable Standards | GB/T 3536, GB/T 267, ASTM D92 |
| Accuracy | ±2 °C |
| Resolution | 0.1 °C |
| Display | Color LCD Touchscreen |
| Data Storage | 2000 test records with timestamp |
| Cooling | Integrated high-efficiency forced-air cooling |
| Power Consumption | ≤550 W |
| Dimensions | 430 × 280 × 285 mm |
| Weight | 16.5 kg |
| Environmental Operating Conditions | 5–45 °C, 10–80% RH |
| Power Supply | 220 V ±10%, 50 Hz |