Flow Injection Analyzer
Filter
Showing 1–30 of 38 results
| Brand | AMS Alliance |
|---|---|
| Model | FUTURA |
| Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥100 positions |
| Reagent Positions | ≥100 |
| Flow Cell Path Length | 15–50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Analysis Rate | 15–120 samples/hour |
| Sample Volume | 0.5–100 µL |
| Peristaltic Pump | 13 rollers per channel |
| Flow Rate Range | 50–3000 µL/min |
| Linear Absorbance Range | 0–2.5 AU |
| Dimensions | 240 × 650 × 410 mm |
| Weight | 17 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥100 positions |
| Reagent Positions | 1–20 |
| Flow Cell Pathlength | 15–50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | FUTURA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 200 positions / 5 racks |
| Reagent Positions | 104 or 360 |
| Flow Cell Path Length | 50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 104-position turntable autosampler (optional 360-position XYZ autosampler) |
| Reagent Positions | 36 |
| Flow Cell Path Length | 50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Detection Limit | Sub-ppb level |
| Throughput | Up to 120 samples/hour |
| Pump Tubing | 52 channels (2 × 26) |
| Flow Rate Range | 50–3000 µL/min |
| A/D Resolution | 24-bit (1.68 × 10⁷) |
| Dimensions (Main Unit) | 75 × 50 × 42 cm |
| Weight (Main Unit) | 45 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMAs |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Volume | 0.5 mL |
| Reagent Positions | 104 |
| Flow Cell Path Length | 5–50 mm |
| Light Source | Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | SmartChem 200 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Test | 300 µL |
| Sample Positions | 126 |
| Reagent Positions | 200 (including refrigerated slots) |
| Cuvette Path Length | 10 mm |
| Light Source | LED and Halogen Tungsten Lamp (6 V / 10 W, 2000 h lifetime) |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem 450 |
| Sample Capacity | 100 positions (standard configuration) |
| Reagent Positions | 72 (with optional refrigeration) |
| Wavelength Range | 340–880 nm |
| Cuvette Path Length | 6 mm |
| Light Source | 6 V / 10 W halogen lamp |
| Throughput | up to 450 determinations per hour (including ISE module) |
| Absorbance Range | 0.001–4.200 Abs |
| Resolution | 0.0001 Abs |
| Temperature Control | 37 °C ± 0.3 °C |
| Dimensions | 500 × 700 × 1050 mm (H × W × L) |
| Weight | 48 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem 600 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 |
| Cuvette Pathlength | 6 or 10 mm |
| Light Source | LED |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | Smartchem 600 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Cup | 300 µL |
| Sample Capacity | 126 positions |
| Reagent Positions | 600 |
| Cuvette Path Length | 10 mm |
| Light Source | LED and Halogen Lamp |
| [Brand | AMS Alliance |
|---|---|
| Origin | USA |
| Model | Smartchem 600 |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 (with refrigeration) |
| Wavelength Range | 340–1100 nm |
| Cuvette Path Length | 10 mm (6 mm optional) |
| Detection Principle | Dual-beam, dual-wavelength photometry |
| Maximum Throughput | 600 samples/hour |
| Reaction Disc Capacity | 85 reusable cuvettes |
| Temperature Control | 37 °C ± 0.3 °C |
| Linear Absorbance Range | 0.00001–4.2 Abs |
| Resolution | 0.00001 Abs |
| Minimum Reaction Volume | 180 µL |
| Compliance | ISO, AOAC, US EPA, AFNOR, COFRAC, BATF] |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | Smartchem140 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 330–840 nm |
| Sample Capacity | 64 positions |
| Reagent Positions | 24 + 10 |
| Cuvette Path Length | 6 mm |
| Light Source | Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem200 |
| Product Type | Automated Discrete Analyzer |
| Wavelength Range | 420–880 nm |
| Sample Capacity | 126 positions |
| Reagent Positions | 10 (expandable to 28) |
| Cuvette Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Tungsten Lamp (2000 h lifetime) |
| Measurement Speed | Up to 200 tests/hour (per method) |
| Minimum Reaction Volume | 300 µL |
| Absorbance Range | 0.001–2.500 Abs |
| Absorbance Resolution | 0.0001 Abs |
| Thermostat Accuracy | 37 °C ± 0.3 °C |
| Dimensions (H×W×L) | 420 × 650 × 1000 mm |
| Weight | 43 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | Smartchem600 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 12 fixed wavelengths from 340 to 880 nm |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 |
| Cuvette Path Length | 6 mm or 10 mm |
| Light Source | High-stability LED |
| Brand | AMS |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FUTURA Segmented Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 240–720 positions |
| Reagent Positions | 5–30 |
| Flow Cell Path Length | 5–500 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-1000 |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 162 positions |
| Reagent Positions | 3–8 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Instrument Type | Discrete Analyzer (Flow-Based Spectrophotometric Analyzer) |
| Model | CleverChem F.U.V. |
| Wavelength Range | 200–850 nm |
| Sample Volume per Test | 10 mL |
| Reagent Positions | N/A (Reagent-free operation for core wine parameters) |
| Flow Cell Pathlength | 0.20 mm |
| Light Source | Deuterium + Tungsten-Halogen UV/Vis Lamp (2000 h lifetime) |
| FTIR Resolution | < 0.4 cm⁻¹ |
| UV-Vis Spectral Resolution | 0.25 nm |
| Detector | 2048-pixel CCD array (200 × 14 µm/pixel) |
| Temperature Control Range | 5–35 °C |
| Dimensions (Analyzer Unit) | 35 × 28 × 26 cm (W×D×H) |
| Weight | 10 kg |
| Compliance | Designed for GLP-compliant wine laboratories |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-100 |
| Product Type | Continuous Flow Analyzer (CFA) |
| Air Segmentation Technology | Yes |
| Online Pretreatment Modules | Heating, Digestion, Distillation, Dialysis, Extraction, Deaeration |
| Detection Options | Full-spectrum CCD detector or high-sensitivity dual-beam silicon photodiode detector |
| Flow Cell Pathlength Options | 10 mm – 200 mm |
| Reaction Coil Material | Fused silica (2 mm ID) |
| Sample Introduction | Optional autosampler with automatic needle cleaning, programmable wash solution replacement, carbon fiber or borosilicate glass sampling probes |
| Compliance Standards | GB, HJ, EPA Methods (e.g., EPA 375.4, 450.1, 420.1), ISO 6878, ISO 11908, ISO 15681 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HGCF-200 |
| Price Range | USD 70,000 – 100,000 (FOB China) |
| Instrument Type | Continuous Flow Analyzer (CFA) |
| Detection Principle | Segmented Flow Spectrophotometry with Air Segmentation |
| Optical Detection Options | Full-spectrum CCD detector or high-sensitivity dual-beam silicon photodiode detector |
| Flow Cell Pathlength Options | 10 mm to 200 mm |
| Reaction Coil Material | Fused silica (2 mm inner diameter) |
| Integrated Sample Pretreatment | On-line digestion, distillation (steam distillation/blow-out), dialysis, extraction, heating, mixing, dilution, degassing, and auto-cleaning |
| Compliance Standards | ASTM D3869, ISO 14402, ISO 14403, ISO 23913, ISO 15681-2, HJ 665–667, HJ 670, CJJ/T 141, SL/T 788, NY/T 1121.7, NY/T 1228 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HGFI-10 |
| Product Category | Flow Injection Analyzer |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowIR™ |
| Product Type | Continuous Flow Analyzer |
| Spectral Range | 4000–650 cm⁻¹ |
| Detector | DTGS |
| Pressure Range | Ambient to 7 bar (standard), up to 30 bar (high-pressure option) |
| Temperature Range | Ambient to 120 °C |
| Internal Cell Volume | 10 µL or 50 µL |
| Integrated Temperature Sensor | Yes |
| Dimensions (W×D×H) | 137 × 241 × 116 mm |
| Weight | 2.6 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DS Micro Flow Cell |
| Pricing | Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RC-800 |
| Pricing | Upon Request |
| Instrument Type | Flow Injection Analyzer (FIA) |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA100 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 25–1000 nm |
| Sample Capacity | Configurable (via rotary autosampler) |
| Reagent Positions | Unlimited (modular reagent rack support) |
| Cuvette Path Length | 10 mm |
| Light Source | High-Stability LED |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | Flowstar 2020BJ |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Cup Capacity | 100 / 180 / 270 positions (5 mL, 8 mL, or 10 mL per cup) |
| Reagent Positions | 100 / 180 / 270 |
| Flow Cell Pathlength | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | Flowstar 2020FL |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Volumes | 5/8/10 mL per cup |
| Capacity | 100/180/270 positions |
| Reagent Positions | 100/180/270 |
| Flow Cell Path Lengths | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | SYSTEA |
|---|---|
| Origin | Italy |
| Model | EASYCHEM PLUS |
| Product Type | Discrete Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 60 positions (18-sample carousel + auxiliary racks) |
| Reagent Positions | 18 |
| Flow Cell Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Lamp with UV-Visible Spectral Output |
| Detection Principle | Photometric Colorimetry (Static Reaction in Flow-Through Cuvette) |
| Compliance | Designed for ASTM D129, ISO 6878, ISO 15681, USP <621>, EPA Methods 353.2, 365.2, 4500-NH₃ F, 4500-NO₂⁻ B, 4500-P E, and GLP/GMP-aligned workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA 7Plus |
| Product Type | Flow Injection Analyzer |
| Category | Chemical Analysis Instrumentation — General Analytical Instruments — Flow Injection Analyzer |
| Manufacturer Status | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Pricing | Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA E |
| Type | Integrated Flow Injection Analyzer (FIA) System |
| Configuration | Fully Automated, Channel-Independent Modular Design |
| Standard Package | Auto-sampler, Main Unit, Control PC, Thermal Printer |
| Optional Modules | MAC3 Multi-Analyte Configuration Module (17 parameters) |
| Compliance Context | Designed for ASTM D129, ISO 6775, ISO 1192, EPA 300.0, EPA 354.1, USP <643>, and GLP/GMP-aligned data integrity workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | iFIA E |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 10–50 mL per vial / 50–300 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten Lamp |