| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem Anna |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 31 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Instrument Type | Discrete Analyzer (Flow-Based Spectrophotometric Analyzer) |
| Model | CleverChem F.U.V. |
| Wavelength Range | 200–850 nm |
| Sample Volume per Test | 10 mL |
| Reagent Positions | N/A (Reagent-free operation for core wine parameters) |
| Flow Cell Pathlength | 0.20 mm |
| Light Source | Deuterium + Tungsten-Halogen UV/Vis Lamp (2000 h lifetime) |
| FTIR Resolution | < 0.4 cm⁻¹ |
| UV-Vis Spectral Resolution | 0.25 nm |
| Detector | 2048-pixel CCD array (200 × 14 µm/pixel) |
| Temperature Control Range | 5–35 °C |
| Dimensions (Analyzer Unit) | 35 × 28 × 26 cm (W×D×H) |
| Weight | 10 kg |
| Compliance | Designed for GLP-compliant wine laboratories |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | FLOWSTAR2020 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 270–1100 nm |
| Sample Volumes/Cup Capacity | 5 mL / 100 cups, 8 mL / 180 cups, 10 mL / 270 cups |
| Reagent Positions | 100, 180, or 270 |
| Flow Cell Path Lengths | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-100 |
| Product Type | Continuous Flow Analyzer (CFA) |
| Air Segmentation Technology | Yes |
| Online Pretreatment Modules | Heating, Digestion, Distillation, Dialysis, Extraction, Deaeration |
| Detection Options | Full-spectrum CCD detector or high-sensitivity dual-beam silicon photodiode detector |
| Flow Cell Pathlength Options | 10 mm – 200 mm |
| Reaction Coil Material | Fused silica (2 mm ID) |
| Sample Introduction | Optional autosampler with automatic needle cleaning, programmable wash solution replacement, carbon fiber or borosilicate glass sampling probes |
| Compliance Standards | GB, HJ, EPA Methods (e.g., EPA 375.4, 450.1, 420.1), ISO 6878, ISO 11908, ISO 15681 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HGCF-200 |
| Price Range | USD 70,000 – 100,000 (FOB China) |
| Instrument Type | Continuous Flow Analyzer (CFA) |
| Detection Principle | Segmented Flow Spectrophotometry with Air Segmentation |
| Optical Detection Options | Full-spectrum CCD detector or high-sensitivity dual-beam silicon photodiode detector |
| Flow Cell Pathlength Options | 10 mm to 200 mm |
| Reaction Coil Material | Fused silica (2 mm inner diameter) |
| Integrated Sample Pretreatment | On-line digestion, distillation (steam distillation/blow-out), dialysis, extraction, heating, mixing, dilution, degassing, and auto-cleaning |
| Compliance Standards | ASTM D3869, ISO 14402, ISO 14403, ISO 23913, ISO 15681-2, HJ 665–667, HJ 670, CJJ/T 141, SL/T 788, NY/T 1121.7, NY/T 1228 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HGFI-10 |
| Product Category | Flow Injection Analyzer |
| Brand | INNYAO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | IC-100 |
| Instrument Type | Discrete Flow Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 200 positions (standard carousel) / 100 positions (optional dual-rack configuration) |
| Reagent Positions | 4 |
| Cuvette Path Length | 10 mm |
| Light Source | Single-beam halogen lamp (6 V / 10 W) |
| Optical System | Fixed-wavelength photometric detection with selectable filters |
| Brand | KPM AMS |
|---|---|
| Origin | USA |
| Model | SmartChem 140 |
| Product Type | Discrete Chemistry Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥50 positions |
| Reagent Positions | ≥20 |
| Cuvette Path Length | 6 mm |
| Light Source | Tungsten-halogen lamp (6 V / 10 W, 2000 h lifetime) |
| Absorbance Range | 0–3.5 OD |
| Resolution | 0.0001 Abs |
| Optical System | Dual-beam with 9-position filter wheel + blind position |
| Detection | Silicon photodiode |
| Analysis Speed | Up to 140 samples/hour |
| Sample Volume | 3–450 µL |
| Reagent Consumption per Test | ~300 µL |
| Sample Tube Dimensions | 16 mm × 100 mm (diameter × height) |
| Automatic Dilution | Yes |
| Standard Preparation | Automated serial dilution from single stock standard |
| Blank Correction | True sample blank subtraction |
| Calibration | Up to 6th-order polynomial regression |
| Data Output | Raw absorbance-time profiles with reprocessing capability |
| Compliance | ISO, AOAC, APHA, USEPA, AFNOR, COFRAC, BATF methods |
| Brand | KPM AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | SmartChem 450 |
| Sample Capacity | 100 positions |
| Reagent Positions | 72 |
| Optical Path Length | 10 mm |
| Wavelength Range | 340–1100 nm |
| Light Source | Tungsten-Halogen and Deuterium (Dual) Photometric Source |
| Detection Resolution | 0.0001 Abs |
| Minimum Reaction Volume | 200 µL |
| Throughput | Up to 450 samples/hour |
| Filtration | 9-position motorized filter wheel |
| Compliance | ISO/IEC 17025, US EPA Methods (e.g., 353.2, 365.4), AOAC, OIV, AFNOR, COFRAC, BATF |
| Brand | KPM-AMS |
|---|---|
| Origin | USA |
| Model | Futura II |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340 nm – 1100 nm |
| Sample Capacity | 240 positions |
| Reagent Positions | 20 |
| Flow Cell Path Length | 10 mm – 5 m |
| Light Source | Photometric Lamp |
| Brand | KPM-AMS |
|---|---|
| Origin | USA |
| Model | Futura III |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–110 nm |
| Sample Capacity | ≥240 positions |
| Reagent Positions | 20 |
| Flow Cell Path Length | 10 mm to 5 m |
| Light Source | Photometric light source |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MKG-J2H |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Continuous Flow Analyzer |
| Wavelength Range | Not applicable (microwave frequency domain, 2.45 GHz) |
| Sample Capacity | 1 stream |
| Reagent Ports | 1 |
| Flow Cell Optical Path Length | 300 mm |
| Radiation Source | 2.45 GHz Magnetron-Based Microwave Generator |
| Microwave Power Output | 0–1600 W, continuously adjustable |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 600 × 400 × 1200 mm |
| Cavity Dimensions (W×D×H) | 450 × 400 × 550 mm |
| Tubing Material | High-purity alumina ceramic or PEEK-lined engineering polymer |
| Internal Tubing Diameter | 60 mm |
| Temperature Monitoring | Integrated Pt100 RTD sensor with closed-loop feedback |
| Control System | Industrial PLC with 7-inch HMI touchscreen interface |
| Safety Compliance | Meets GB 10436-2008 (Chinese national standard for microwave leakage ≤ 5 mW/cm² at 5 cm) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowIR™ |
| Product Type | Continuous Flow Analyzer |
| Spectral Range | 4000–650 cm⁻¹ |
| Detector | DTGS |
| Pressure Range | Ambient to 7 bar (standard), up to 30 bar (high-pressure option) |
| Temperature Range | Ambient to 120 °C |
| Internal Cell Volume | 10 µL or 50 µL |
| Integrated Temperature Sensor | Yes |
| Dimensions (W×D×H) | 137 × 241 × 116 mm |
| Weight | 2.6 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DS Micro Flow Cell |
| Pricing | Upon Request |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iLab-FIA |
| Wavelength Range | 400–1100 nm |
| Flow Cell Path Length | 10 mm |
| Light Source | LED |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RKCF-200 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 81 positions |
| Flow Cell Path Length | 1–5 cm |
| Light Source | LED |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | RKFI-100 |
| Price Range | USD 11,200 – 25,200 (based on exchange rate of ¥1 = USD 0.14) |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1050 nm |
| Sample Capacity | 42 positions / 79 cups |
| Reagent Positions | 12 |
| Flow Cell Path Lengths | 10 mm / 20 mm / 30 mm |
| Light Source | LED |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RC-800 |
| Pricing | Upon Request |
| Instrument Type | Flow Injection Analyzer (FIA) |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Model | IFFM-EA |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 325–1000 nm |
| Cuvette Path Length | 10 mm (standard, fixed) |
| Wavelength Accuracy | ≤ ±2 nm |
| Wavelength Repeatability | 1 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | < 0.1% T (at NaNO₂) |
| Dark Current Drift | 0.2% T / 3 min |
| Light Current Drift | 0.5% T / 3 min |
| Data Acquisition Rate | 1–100 samples/s |
| Gain Settings | 1×, 2×, 4×, 8×, 16× |
| Filter Cutoff Frequency | 10–100 Hz |
| Pump Speed Control | 0–99 digital steps |
| Number of Pump Channels | 10 (5 per pump) |
| Valve Configuration | 16-position auto/manual selector valve |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | IFIS Series |
| Product Type | Flow Injection Sampler |
| Pump Speed Range | 0–99 rpm |
| Maximum Sample Throughput | >600 samples/h |
| Number of Integrated Peristaltic Pumps | Dual |
| Number of Fluid Channels | Up to 10 (5 per pump) |
| Valve Configuration | Dual 16-position auto/manual switching valves (supporting up to 8 independent fluid paths) |
| Programmable Steps | Up to 15 sequences × 10 steps each |
| Control Interface | RS-232/USB |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA100 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 250–1000 nm |
| Sample Capacity | Configurable (via rotary autosampler) |
| Reagent Positions | Unlimited (modular reagent rack support) |
| Flow Cell Path Length | 10 mm |
| Light Source | High-Stability LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA100 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 25–1000 nm |
| Sample Capacity | Configurable (via rotary autosampler) |
| Reagent Positions | Unlimited (modular reagent rack support) |
| Cuvette Path Length | 10 mm |
| Light Source | High-Stability LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA100 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 180 positions / 120 cups |
| Reagent Positions | 17 |
| Flow Cell Path Length | 10–50 mm |
| Light Source | LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA3 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–900 nm |
| Sample Capacity | 120 / 180 / 270 positions |
| Reagent Positions | Unlimited |
| Cuvette Path Length | 10 mm, 30 mm, 50 mm |
| Light Source | High-Pressure Krypton Lamp / LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | AA3 |
| Product Type | Continuous Flow Analyzer |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Instrument Type | Continuous Flow Analyzer (CFA) |
| Detection Principles | Colorimetric Spectrophotometry (NH₄⁺, NO₃⁻, PO₄³⁻, K⁺, Ca²⁺, B, SO₄²⁻, Urea) |
| Sample Throughput | Up to 50 samples/h (per channel) |
| Reagent Consumption | 50 µL – 2 mL per determination |
| Precision (RSD) | NH₃-N: 0.02–0.04% |
| P (available P) | 0.02–0.04% |
| K | 0.03–0.05% |
| Compliance | ASTM D5178, ISO 11261, ISO 13878, EN 15972, AOAC 971.22, USP <731> |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA500 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 250–1000 nm |
| Sample Capacity | 180 positions / 120 cups |
| Reagent Positions | 34 |
| Flow Cell Path Length | 10–50 mm (selectable) |
| Light Source | LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA500 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 250–1000 nm |
| Sample Capacity | 180 positions / 120 cups |
| Reagent Positions | 34 |
| Flow Cell Path Length | 10–50 mm (selectable) |
| Light Source | LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AA500 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 250–880 nm |
| Sample Capacity | 180 positions / 120 cups |
| Reagent Positions | 34 |
| Flow Cell Path Length | 10–50 mm (selectable) |
| Light Source | LED |
| Brand | SEAL |
|---|---|
| Origin | Germany |
| Model | AQ2 |
| Product Type | Discrete Analytical System |
| Sample Volume | 3–500 µL per test |
| Reagent Consumption | 250 µL per test |
| Wavelength Range | 400–900 nm |
| Flow Cell | 20 mm thermostatted quartz cuvette |
| Sample Capacity | 100 positions |
| Reagent Positions | 15 × 45 mL refrigerated vials |
| Reaction Time | Up to 16 min |
| Power Supply | 100–250 V, 50/60 Hz, 450 W |
| Dimensions (W×D×H) | 680 × 550 × 410 mm |
| Weight | 40 kg |