- All
- Favorite
- Popular
- Most rated
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MIT-Fold |
| Pricing | Available Upon Request |
| Measurement Range | 1–60,000 folds |
| Fold Count Log Scale | 0–4.78 (log₁₀) |
| Tension Adjustment Range | 4.9–14.7 N |
| Folding Angle | ±135° ±2° (left/right) |
| Folding Frequency | 175 ±10 cycles/min |
| Fold Head Slit Widths | 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm (standard: 0.50 mm & 0.75 mm supplied |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 330 × 250 × 400 mm |
| Net Weight | ~37 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y310-3 |
| Price Range | USD 14,000 – 72,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Detection Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45°C (5–50°C optional) |
| Humidity Control | 0%RH (dry), 30–90%RH, 100%RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions (W×D×H) | 700×560×370 mm |
| Weight | 100 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GB-KF30010S |
| Price Range | USD 42,000 – 70,000 |
| Filtration Efficiency Range | 0–99.999% |
| Flow Rate Control | 20–100 L/min |
| Pressure Drop Range | 0–1000 Pa |
| Test Particle Sizes | 0.3 µm, 0.5 µm, 5.0 µm |
| Aerosol Sources | DEHS (Di-Ethyl-Hexyl-Sebacate) and 2% NaCl solution |
| Standard Test Area | 100 cm² (customizable per mask geometry) |
| Dimensions | 130 × 75 × 157 cm |
| Weight | 250 kg |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | <1500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZM-100A |
| Instrument Type | Vertical Sterilizer |
| Max Temperature | 135 °C |
| Max Pressure | 0–0.22 MPa (Saturated Steam Pressure) |
| Sterilization Chamber Dimensions | Ø400 mm × 500 mm (H) |
| External Dimensions | Ø500 mm × 560 mm (H) |
| Chamber Volume | 50 L |
| Safety Relief Pressure | 0.23 MPa |
| Back-Pressure Range | 0.14–0.165 MPa |
| Water Replenishment Pressure | ≥0.32 MPa |
| Timer Range | 1–99.59 min |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 4.5 kW ±10% |
| Compliance Standards | GB 150.1–2011, GB/T 10004–2008, GB 4793.4–2001, YY 1007–2010 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GBPI W413 2.0 |
| Quotation | Upon Request |
| Test Principle | Infrared Moisture Detection |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH (dry gas), 30–90% RH, and 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per test cycle |
| Carrier Gas | Ultra-high-purity nitrogen (99.999%), ≥0.1 MPa supply pressure, 5–100 mL/min flow rate |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | N600-L |
| Pricing | Upon Request |
| Testing Principles | Gurley (1.23 kPa ± 0.01 kPa), Schopper (1.00 kPa ± 0.01 kPa or 2.50 kPa ± 0.01 kPa), Bentzen (1.47 kPa ± 0.02 kPa) |
| Standards Compliance | SJ/T 10171–2016, GB/T 458–2008, GB/T 36363–2018 |
| Measurement Range | 0.01–2.5 µm/(Pa·s) |
| Air Flow Rate | 0.01–120 mL/min (customizable ranges available) |
| Resolution | 0.001 µm/(Pa·s) |
| Differential Pressure Range | 0–3 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area Options | 6.42 cm² (50 mm × 50 mm) or 10.0 ± 0.2 cm² (60 mm × 100 mm or 50 mm × 50 mm) |
| Test Duration | 10–6000.0 s |
| Sample Conditioning | 24 h at <40 °C and 10–35% RH |
| Chamber Environmental Monitoring | Integrated temperature & humidity sensors |
| Seal Integrity | ≤1.0 mL/h leakage rate |
| Test Volume Capacity | 1 L |
| Dimensions (L×W×H) | 500 mm × 400 mm × 300 mm |
| Power | 100 W |
| Supply | 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GBPI Y310 2.0 |
| Price | USD 54,500 (FOB Guangzhou) |
| Test Principle | Coulometric Oxygen Sensor Method |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1307, ISO 15105-2, DIN 53380-3, JIS K-7126-B, YBB 00082003 |
| Measurement Range | 0.05–1000 cm³/(m²·24 h) (up to 260,000 cm³/(m²·24 h) with auxiliary mask) |
| Resolution | 0.001 cm³/(m²·24 h) |
| Temperature Control Range | 15–45 °C |
| Temperature Stability | ±0.1 °C |
| Test Area | 50.24 cm² (customizable down to 0.785 cm²) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 independent test chambers |
| Carrier Gas Pressure | ≥0.1 MPa |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power Consumption | 750 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | GB-BF20010M |
| Pressure Settings | 3, 5, 7, 14, 20 kPa |
| Test Area | 28.27 cm² (75 mm × 75 mm specimen) |
| Air Supply | Compressed air, regulated to (20 ± 1) kPa |
| Power | AC 220 V, 50 Hz, 100 W |
| Timer Resolution | ±1 s |
| Clamp Torque | 13.5 N·m |
| Retention Mesh | ≥50% open area, ≤5 mm deflection at 20 kPa |
| Construction | Stainless steel test chamber |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBW-180 |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±1% FS |
| O₂ Detection Range | 0–25% |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–100 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Gas Flow Control Range | 0.01–10 L/min |
| Flow Control Accuracy | ±1.0% FS |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Reactor Volume per Chamber | 3 L |
| Max. Number of Simultaneous Reactors | 18 |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 5 kW |
| Dimensions (L×W×H) | 6950 × 1800 × 650 mm |
| Weight | 1500 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | N500 Gas Permeability Tester |
| Measurement Range | 0.02–50,000 cm³/m²·day·0.1 MPa (expandable to 600,000 cm³/m²·day·0.1 MPa) |
| Measurement Accuracy | ±0.01 cm³/m²·day·0.1 MPa |
| Temperature Range | 5–50 °C |
| Temperature Control Accuracy | ±0.01 °C |
| Humidity Range | 0 %RH (5–100 %RH optional) |
| Humidity Control Accuracy | ±2 %RH |
| Vacuum Precision | 0.1 Pa |
| Test Chamber Vacuum Level | <20 Pa |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Test Gases | O₂, CO₂, N₂ |
| Max Sample Thickness | ≤2 mm |
| Effective Test Area | 50.24 cm² (Φ80 mm) |
| Power Supply | 220 V AC, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBDA-180a |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| Measurement Resolution | ±1.0% FS |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 3 L |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±1% FS |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Range | 0–100 kPa |
| Pressure Accuracy | ±1% FS |
| Gas Supply Pressure | 0.2–0.8 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 5 kW |
| Dimensions (L×W×H) | 6950 × 1800 × 650 mm |
| Weight | 1500 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | W202-1 |
| Application | Multi-purpose WVTR analyzer for films, sheets, and packaging containers |
| Test Range | 0.001–100 g/(m²·24h) |
| Test Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45°C (optional 5–55°C) |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Control Range | 0%RH, 30–95%RH |
| Humidity Control Accuracy | ±1%RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤2 mm |
| Sample Capacity | 2 chambers (independent operation) |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–100 mL/min |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 585 × 485 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V / 50 Hz |
| Compliance | GB/T 21529-2008, YBB 00092003-2015, BS EN ISO 15106-3:2005, ASTM E398-2013, DIN 53122-2 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GB-KF30010KL |
| Filtration Efficiency Range | 0–99.999% |
| Flow Rate Range | 20–100 L/min |
| Pressure Drop Range | 0–1000 Pa |
| Test Particle Sizes | 0.3 µm, 0.5 µm, 5.0 µm |
| Aerosol Sources | DEHS (oil-based) and 2% NaCl (salt-based) |
| Standard Test Area | 100 cm² |
| Power Consumption | <1500 W |
| Dimensions | 130 × 75 × 157 cm |
| Weight | 250 kg |
| Power Supply | AC 220 V, 50 Hz |