| Brand | ATS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AH-1500 |
| Instrument Type | High-Pressure Homogenizer |
| Maximum Design Pressure | 2000 bar |
| Maximum Operating Pressure | 1800 bar |
| Viscosity Limit | < 2000 cP |
| Flow Rate | 25 mL–15 L/h |
| Maximum Feed Particle Size | < 500 µm |
| Maximum Feed Temperature | < 90 °C |
| Dimensions (W×H×L) | 440 × 410 × 800 mm |
| Weight | 110 kg |
| Brand | Aquapro |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TR Series |
| Quotation | Upon Request |
| Purified Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | ≤0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin Level | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| RO Production Rate (25 °C) | 5/10/20 L/h |
| Dispensing Accuracy | ±5 mL (≤500 mL), ±1.5% (>500 mL) |
| Flow Rate | ≤2 L/min |
| Dimensions (H×W×D) | 540×380×480 mm |
| Weight | 40 kg |
| Feed Water Conductivity | <1000 µS/cm |
| Feed Pressure | 1–5 kgf/cm² |
| Feed Temperature | 5–35 °C |
| Chlorine | <1 ppm |
| pH | 6.5–8.5 |
| Hardness (as CaCO₃) | <450 ppm |
| Input Power | 100–240 VAC, 50–60 Hz |
| Max Power Consumption | 221 W |
| Acoustic Noise | <50 dB(A) |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Model | qTOWER3 84G |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 384-well format |
| Maximum Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Configuration | 6-channel excitation/emission system (configurable 1–6 channels) |
| Light Source | RGBW high-intensity long-life LEDs (blue, green, red, white) |
| Detector | High-sensitivity channel-type photomultiplier tube (PMT) |
| Detection Method | 16-channel fiber-optic scanning |
| Sensitivity | Single-copy DNA detection |
| Dynamic Range | 10 orders of magnitude |
| Recommended Reaction Volume | 2–30 µL |
| Linear Temperature Gradient | 24-column gradient |
| Thermal Module | Peltier-based with corrosion-resistant surface |
| Hot Lid Temperature | Up to 110 °C with auto-adjusting pressure (up to 30 kg/plate) |
| Noise Level | ≤45 dB(A) |
| Software | MIQE-compliant analysis suite with unlimited installation and lifetime free updates |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | qTOWER3 G touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Maximum Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.10 °C |
| Excitation Source | Four solid-state RGBW LEDs (blue, green, red, white) |
| Detection System | 8-channel fiber-optic scanning with channel-type photomultiplier tube (PMT) |
| Detection Channels | Configurable 1–6 channels |
| Thermal Gradient | 12-column linear gradient (spanning up to 40 °C) |
| Sample Block Material | Gold-plated pure silver block |
| Lid System | Motorized, pressure-regulated heated lid with auto-height adjustment |
| Software | qPCRsoft v5.x compliant with MIQE guidelines, supporting absolute quantification, relative quantification (ΔΔCt & dual standard curve), melting curve analysis, SNP/allelic discrimination, endpoint analysis, amplification efficiency calculation, and audit-trail-enabled reporting per FDA 21 CFR Part 11 requirements |
| Brand | Yamato |
|---|---|
| Origin | Japan |
| Model | ICF410C |
| Temperature Range | Ambient +5°C to 80°C |
| Temperature Uniformity | ±1.0°C at 37°C |
| Chamber Volume | 89 L |
| Temperature Stability | ±0.1°C at 37°C (JIS/GB compliant) |
| Construction | Interior – SUS304 Stainless Steel |
| Heating System | Ni-Cr Wire Heater (360 W), Air Jacket with Adjustable Fan Speed (including off mode) |
| Safety Features | Dual Over-Temperature Protection (PID-based auto cut-off + independent mechanical over-heat preventer), Leakage Current Circuit Breaker, Self-Diagnostic Circuit (sensor fault, heater open, SSR short), Keypad Lock |
| Controller | PID Digital Microprocessor with Dual 4-Digit LED Display (Green for Actual Temp, Red for Setpoint), Programmable Timer (1 min–999 h 50 min), Deviation Correction Function, Power Failure Recovery |
| Dimensions (W×D×H mm) | 560×606×820 (External) |
| Net Weight | ~45 kg |
| Power Supply | AC 220 V, 50/60 Hz, 2 A |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | SPF601 |
| Spectral Range | 290–400 nm (UVA + UVB) |
| Output Configuration | Six independent 8-mm square irradiation ports |
| Irradiance Control | Individual manual knob per port + optional XPS-300 programmable power supply |
| Maximum Irradiance | Up to 4 MED/min per port |
| Solar Simulation Fidelity | >90% spectral match to CIE Reference Solar Spectrum (ISO 17166:2019/Erythema Action Spectrum) |
| Mechanical Positioning | Integrated precision locking gooseneck arm with UV-stable optical coupling |