Halogen Analyzer
Filter
Showing all 7 results
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Country of Origin | Imported |
| Model | multi X 2500 |
| Price | Upon Request |
| Brand | Chemo |
|---|---|
| Origin | Hubei, China |
| Model | AOX-S |
| Measurement Principle | Combustion-Coulometric Titration |
| Max Combustion Temperature | 1300 °C |
| Sample Introduction Method | Column Adsorption with N₂ Pressurization |
| Sample Mass Range | 5–1000 mg |
| Detection Range | 0.8–1000 µg/L (as Cl⁻ equivalent) |
| Typical Analysis Time (combustion + titration) | 3–10 min |
| Carrier Gas | O₂ ≥99.6% (optional high-purity O₂ ≥99.999%) |
| Sample Boat | Modified ceramic boat enabling direct sample loading |
| Optional Feature | Automated Sample Introduction Module |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Behr CL10 (AOX/EOX/POX) |
| Measurement Principle | Combustion–Microcoulometric Titration |
| Measurement Range | 0.1–3000 mg/L Cl (as Cl⁻ equivalent) |
| Accuracy | <1% RSD |
| Repeatability | <1% RSD |
| Detection Limit | 0.1 µg Cl absolute |
| Resolution | 0.01 µg Cl |
| Carrier Gases | O₂ (99.95%), Ar (99.95% for EOX) |
| IR Furnace Max Temp | 1000 °C |
| Resistive Downstream Furnace Max Temp | 1000 °C |
| Sample Capacity | AOX—up to 200 mL aqueous |
| Analysis Time | 5–10 min per sample (halogen-content dependent) |
| Titration Current Range | 2–450 µA |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX- Organic Halogen Combustion Furnace |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Sample Throughput | Up to 24 samples per batch (standard configuration) |
| Combustion Temperature Range | Ambient to 1100 °C (programmable, ±2 °C stability) |
| Gas Supply | Dual-gas system (N₂ for adsorption, O₂ for combustion) |
| Tube Material | High-purity quartz combustion tube (OD 15 mm, length 600 mm) |
| Integrated Scrubbing System | Five-stage acid/alkali wash bottles + dual absorption traps |
| Brand | LANTIAN |
|---|---|
| Model | AOX-C |
| Detection Principle | High-Temperature Combustion Coupled with Ion Chromatography |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Combustion Temperature | Up to 1150 °C |
| Sample Introduction | Nitrogen-Pressurized Column Adsorption |
| Sample Mass Range | 5–1000 mg |
| Detection Range | 0.8–1000 µg/L (as Cl⁻ equivalent) |
| Analysis Time (instrumental) | 3–10 min per sample |
| Carrier Gas | O₂ ≥99.6% (recommended ≥99.999%) |
| Accessories Included | Integrated combustion furnace, quartz combustion tube, dual sample boats, quartz push rod, rubber end caps, adsorption column assembly (×2), 1.27 m silicone tubing (OD 15 mm), 5 scrubbing bottles, 2 absorption bottles, 2 absorption tubes, mounting fixtures,纱布,胶布,扎线 |
| Software Option | Real-time instrument control and quantitative data processing module (optional) |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER AOX |
| Measurement Principle | High-Temperature Combustion–Coulometric Titration |
| Measurement Range | 0.0025–1000 µg Cl/L |
| Accuracy | <3% @ 200 ppb Cl |
| Repeatability | <2.5% RSD |
| LOD | 0.0025 µg Cl |
| Resolution | 0.0025 µg Cl |
| Combustion Temperature | Up to 1150 °C |
| Sample Introduction | 5–1000 mg (solid) or 0.1–10 mL (liquid) |
| Analysis Time (per sample) | 3–10 min (excluding pre-treatment) |
| Carrier Gases | O₂ (99.6%), Ar (99.998%) |
| Autosampler | Standard 20-position, expandable to 60-position |
| Software | TEIS 2 Online Control & Data Processing Platform |
| Compliance | ISO 9562:2004, EN ISO 9562, DIN 38409-H17, EPA Method 1650, HJ 1214–2021, GB/T 34845–2017, GB/T 35613–2017, GB/T 41533–2022, GB/T 22904–2008, GB/T 15959 |
| Brand | Zhuochi |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AOX-3-ZC |
| Price | USD 4,200 (approx.) |
| Measurement Principle | Combustion-Coulometric Titration |
| Measurement Range | 5–1000 µg AOX per sample |
| Accuracy | ±1% (relative to certified reference material) |
| Repeatability (RSD) | ≤1% |
| Detection Limit | 0.8–1000 µg/L (sample-dependent, based on 100 mL preconcentration volume) |
| Resolution | 0.01 µg (coulometric current integration) |